01_introduction_to_testing_services

25
Introduction to Testing Services

Transcript of 01_introduction_to_testing_services

Page 1: 01_introduction_to_testing_services

Introduction toTesting Services

Page 2: 01_introduction_to_testing_services

© Schlumberger 2003

Schlumberger225 Schlumberger DriveSugar Land, Texas 77478

All rights reserved. No part of this book may be reproduced, stored in a retrieval system, or transcribed in any form or by any means, electronic or mechanical, including photo-copying and recording, without prior written permission of the publisher.

SMP-7086-1

This book contains excerpts from the Schlumberger publicationModern Reservoir Testing (SMP-7055). © Schlumberger 1994

An asterisk (*) is used throughout this document to denote a mark of Schlumberger.

Other trademarks or registered trademarks and their respective owners are listed in “Other Marks.”

Page 3: 01_introduction_to_testing_services

Introduction to Testing Services ■ Contents iii

Contents

Book 1 Introduction to Testing Services

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Productivity well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Descriptive well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Test design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Marks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Book 2 Downhole Testing Services

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Schlumberger Reservoir Completions Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Flopetrol Johnston–Schlumberger downhole tools history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Seal Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Downhole environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Recommended elastomer compounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Typical Downhole Test String Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Packers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

FlexPac system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13FlexPac packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14FlexPac hold-down tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

PosiTest packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Long-stroke PosiTest packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Compression-set PosiTest packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Positrieve packer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

IRIS Pulse-Operated Test System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Benefits of the IRIS system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Flexible command system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25IRIS dual-valve tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Pressure Controlled Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31PCT valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Hold-open module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34PORT Pressure Operated Reference Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Formation Protector Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Hydrostatic reference tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Single-shot hydrostatic overpressure reverse valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Single-shot hydrostatic overpressure reverse valve (internal/external) . . . . . . . . . . . . . . . . . 44Multiple-opening, internally operated reversing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Multicycle circulating valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Multicycle circulating valve with lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Pump-through flapper safety valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Page 4: 01_introduction_to_testing_services

iv

Tubing fill/test valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Tubing test valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Single-ball safety valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Pipe tester valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Pump-through safety valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62Slip joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Slip joint and TCP gun correlation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Depth control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Jar tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Safety joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Dual-Action Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Fullbore Annular Sample Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

DST String Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7710k IRIS string with DataLatch recorder and TCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7710k IRIS string for shoot and pull . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79IRIS big-bore string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8010k PCT string with DataLatch recorder and TCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8215k PCT HPHT string with TCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8417.5k extreme HPHT string with single-shot tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8617.5k ultra HPHT string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8715k slimhole PCT string with TCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Tapered string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8810k PERFPAC string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

Book 3A Safety Systems

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Riser Sealing Mandrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3SenTREE 3 Test Tree System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

SenTREE 3 components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Valve assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Latch assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Retainer valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Spanner joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Subsea Control Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Disconnect times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Standard system features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Deep-sea hydraulic system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Deep-sea electrohydraulic system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Drift-off analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Subsea pressure and temperature carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Lubricator Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31E-Z Valve Retrievable Well Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Book 3B Well Testing Services

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Surface testing equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Standard set of equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Equipment layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Page 5: 01_introduction_to_testing_services

Introduction to Testing Services ■ Contents v

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Classified zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Zone 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Zone 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Zone 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Clean zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Safety standards for equipment layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4H2S service requirements and safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Operation guidance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Equipment safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Heat radiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Advanced Well Test Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15General standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Well test design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Equipment safety barriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Surface safety systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Emergency shutdown system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Surface safety valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2921⁄8-in. lightweight flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3121⁄4-in. flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3331⁄8- and 31⁄16-in. flowheads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3561⁄8-in. flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Data Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Sand-Handling Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Dual-pot sand filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Sand separator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Cyclonic desander . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Choke Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Heater types and applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Hydrate prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Viscosity reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Emulsion breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Steam-heat exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Indirect-fired heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Plate-steam exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Test Separator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Separator vessel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Type N test separator (48 in. × 12.5 ft, 1440 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Horizontal test separator (42 in. × 10 ft, 1440 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Type G test separator (42 in. × 15 ft, 720 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Vertical gas separator (2200 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

Oil and Gas Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Oil manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Gas manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Surge tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

Page 6: 01_introduction_to_testing_services

vi

Atmospheric gauge tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Transfer Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Centrifugal transfer pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Screw-type transfer pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Gear-type transfer pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

Oil Burners and Booms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101Benefits and features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102EverGreen burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Green Dragon high-efficiency burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105Mud burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Burner boom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110Standard burner boom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Heavy-duty burner boom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

Book 4 Data Acquisition Services

Laboratory and Acquisition Cabin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Environmental parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Laboratory area description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Gauge Metrology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Static parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Dynamic parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Transient response during temperature variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Transient response during pressure variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Dynamic response during pressure and temperature shock . . . . . . . . . . . . . . . . . . . . . . . 12

Multiphase Flowmeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Operating envelope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Surface testing acquisition network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21SMART system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23STAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Absolute pressure sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

STPS-A pressure transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25STPS-C/D pressure transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Differential pressure sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Temperature sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Flowmeter pulse sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Enhanced liquid measurement flowmeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Universal Pressure Platform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Gauge requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Reliability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Data quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Flexibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

UPP versatility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33UNIGAGE recorder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Page 7: 01_introduction_to_testing_services

Introduction to Testing Services ■ Contents vii

UNIGAGE CQG pressure gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Single-point measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Benefits and features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

UNIGAGE quartz pressure gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Benefits and features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

UNIGAGE H-Sapphire pressure gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Unique construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Test performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

UNIGAGE Sapphire pressure gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Monolithic recorder and sensor section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Test performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

UPP setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Memory guard feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Complete history log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Communication through battery feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Reporting and data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Gauge calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53DataLatch System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

DST gauge adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

DGA with downhole LINC wireline adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66LINC downhole coupler assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67LINC running tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Downhole Shut-In Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Multislickline downhole shut-in tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Explosive-free shut-in tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Book 5 Well Test Interpretation

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Fundamentals of Transient Well Test Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Diffusivity equation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Sidebar: Modeling radial flow to a well . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Wellbore storage and skin effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Type curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Changing wellbore storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Control of Downhole Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Downhole shut-in techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Downhole flow rate measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Wellsite Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Interpretation Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Interpretation methodology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Data processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Flow regime identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Sidebar: Derivative computation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Use of type curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Page 8: 01_introduction_to_testing_services

viii

Use of numerical simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Three stages of modeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Model identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Parameter estimation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Results verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Use of downhole flow rate measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Description of the problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Model identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Parameter estimation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Model and parameter verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Gas well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Specialized Test Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Layered reservoir testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Selective inflow performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Transient layered testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Interpretation of layered reservoir testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

Horizontal wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Multiple-well testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

Interference testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Pulse testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

Vertical interference testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Measurements while perforating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Impulse testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Closed-chamber DST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Water injection wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Pumping wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99Permanent monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

Pressure Transient and System Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103Appendix: Type Curve Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

Book 6 Large-Bore Subsea Services

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Conventional Christmas tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Horizontal Christmas tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2SenTREE* 7 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

SenTREE 7 Basic String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Modular configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Flowhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Lubricator valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Bleedoff valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Retainer valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Helical latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Flapper valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Ball valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Page 9: 01_introduction_to_testing_services

Introduction to Testing Services ■ Contents ix

Accessories and Project-Specific Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Saver and crossover sub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Packoff sub and space-out sub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Spacer sub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Ported slick joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Fishing Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Post-shear retrieval tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Post-unlatch retrieval tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Commander* Control Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Commander hydraulic control system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Commander telemetry control and monitoring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Emergency shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Design and philosophy requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Operational philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Shutdown philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Valve position indication philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Subsea accumulator module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Subsea control module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Subsea spanner joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Subsea umbilical cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Subsea-controlled functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Surface control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Page 10: 01_introduction_to_testing_services

Introduction

Introduction to Testing Services ■ Introduction 1

This first book in the Schlumberger Testing Services set introduces productivity and descriptivewell testing and summarizes test types and design principles. These techniques are the ground-work for the other books on downhole testing services, safety systems and well testing services,and data acquisition services. This book also includes marks lists and nomenclature for the set.

Well testingTests on oil and gas wells are performed at various stages of well construction, completion andproduction. The test objectives at each stage range from simple identification of produced fluidsand determination of reservoir deliverability to the characterization of complex reservoir fea-tures. Most well tests can be grouped as productivity testing or descriptive testing.

Productivity well tests are conducted to■ identify produced fluids and determine their respective volume ratios■ measure reservoir pressure and temperature■ obtain samples suitable for pressure-volume-temperature (PVT) analysis■ determine well deliverability■ evaluate completion efficiency■ characterize well damage■ evaluate workover or stimulation treatment.

Descriptive tests seek to■ evaluate reservoir parameters■ characterize reservoir heterogenities■ assess reservoir extent and geometry■ determine hydraulic communication between wells.

Whatever the objectives, well test data are essential for the analysis, prediction and improve-ment of reservoir performance. These in turn are vital to optimizing reservoir development andefficient asset management.

Well testing technology is evolving rapidly. Integration with data from other reservoir-relateddisciplines, constant evolution of interactive software for transient analysis, improvements indownhole sensors and better control of the downhole environment have all significantly increasedthe importance and capabilities of well testing.

Productivity well testingProductivity well testing, the simplest form of testing, provides identification of productivefluids, collection of representative samples and determination of reservoir deliverability.Formation fluid samples are used for PVT analysis, which reveals how hydrocarbon phases coex-ist at different pressures and temperatures. PVT analysis also provides the fluid physicalproperties required for well test analysis and fluid flow simulation. Reservoir deliverability is akey concern for commercial exploitation.

Page 11: 01_introduction_to_testing_services

2

Estimating a reservoir’s productivity requires relating flow rates to drawdown pressures. This can be achieved by flowing the well at several flow rates using different choke sizes (Fig. 1a)while measuring the stabilized bottomhole pressure and temperature for each correspondingchoke (Fig. 1b).

The plot of flow data versus drawdown pressure is known as the inflow performance relation-ship (IPR). For monophasic oil conditions, the IPR is a straight line and its intersection with thevertical axis yields the static reservoir pressure. The inverse of the slope represents the produc-tivity index of the well. The IPR is governed by properties of the rock-fluid system and near-wellbore conditions.

Figure 1. Relationship between flow rates (q) and drawdown pressures (p).

Wellheadflow rate

(a)

Bottomholepressure

Time

(b)

p1

p0

p4

q1

q2

q3

q4

p3

p2

Page 12: 01_introduction_to_testing_services

Introduction to Testing Services ■ Introduction 3

Examples of IPR curves for low (A) and high (B) productivity are shown in Fig. 2. The steeperline corresponds to poor productivity, which could be caused either by poor formation flow prop-erties (low mobility-thickness product) or by damage caused while drilling or completing the well(high skin factor). For gas wells, IPR curves exhibit a certain curvature (C) caused by extra pres-sure drops resulting from inertial and turbulent flow effects in the vicinity of the wellbore andchanges of gas properties with pressure. Oil wells that flow below the bubblepoint also displaysimilar curvature, but this is due to changes in relative permeability created by variations in satu-ration distributions.

Descriptive well testingEstimation of the formation’s flow capacity, characterization of wellbore damage, and evaluationof a workover or stimulation treatment all require a transient test because a stabilized test isunable to provide unique values for mobility-thickness and skin effect. Transient tests are per-formed by introducing abrupt changes in surface production rates and recording the associatedchanges in bottomhole pressure. The pressure disturbance penetrates much farther than in thenear-wellbore region, to such an extent that pressure transient tests have evolved into one of themost powerful reservoir characterization tools. This form of testing is often called descriptive orreservoir testing.

Production changes during a transient well test induce pressure disturbances in the wellboreand surrounding rock. These pressure disturbances extend into the formation and are affected invarious ways by rock features. For example, a pressure disturbance will have difficulty entering atight reservoir zone but will pass unhindered through an area of high permeability. It may dimin-ish or even vanish upon entering a gas cap. Therefore, a record of the wellbore pressure responseover time produces a curve for which the shape is defined by the reservoir’s unique characteristics.

Figure 2. Typical inflow performance curves.

C

BA

Flow rate at surface conditions (B/D)

Sandface pressure (psia)

0 20,000 40,000 60,000 80,000

4200

3800

3400

3000

2600

Page 13: 01_introduction_to_testing_services

4

Unlocking the information contained in pressure transient curves is the fundamental objective ofwell test interpretation. To achieve this objective, analysts display pressure transient data inthree different coordinate systems:■ log-log (for model recognition of reservoir response)■ semilog (for parameter computation)■ Cartesian (for model and parameter verification).

Typical pressure responses that might be observed with different formation characteristics areshown in Fig. 3. Each plot consists of two curves presented as log-log graphs. The top curve rep-resents the pressure changes associated with an abrupt production rate perturbation, and thebottom curve (termed the derivative curve) indicates the rate of pressure change with respect totime. Its sensitivity to transient features resulting from well and reservoir geometries (which aretoo subtle to recognize in the pressure change response) makes the derivative curve the singlemost effective interpretation tool. However, it is always viewed together with the pressure changecurve to quantify skin effects that are not recognized in the derivative response alone.

Figure 3. Pressure transient log-log plots.

Homogeneous reservoir

Double-porosity reservoir

Impermeable boundary

Elapsed time (hr)

Pressure – pressure derivative (psi)

Page 14: 01_introduction_to_testing_services

Introduction to Testing Services ■ Introduction 5

Pressure transient curve analysis probably provides more information about reservoir charac-teristics than any other technique. Horizontal and vertical permeability, formation pressure, welldamage, fracture length, storativity ratio and interporosity flow coefficient are just a few of thecharacteristics that can be determined. In addition, pressure transient curves can indicate thereservoir’s areal extent and boundary geometry. Figure 4 shows the features of outer boundaryeffects and the effects of damage removal.

The shape of the pressure transient curve, however, is also affected by the reservoir’s produc-tion history. Each change in production rate generates a new pressure transient that passes intothe reservoir and merges with the previous pressure effects. The observed pressures at the well-bore are a result of the superposition of all these pressure changes.

Different types of well tests can be achieved by altering production rates. Whereas a builduptest is performed by closing a valve (shut-in) on a producing well, a drawdown test is performedby putting a well into production. Other well tests, such as multirate, multiwell, isochronal andinjection well falloff, are also possible.

Mathematical models are used to simulate the reservoir’s response to production ratechanges. The observed and simulated reservoir responses are compared during well test inter-pretation to verify the accuracy of the model. For example, by altering model parameters such as permeability or the distance from the well to a fault, a good match can be reached betweenthe real and modeled data. The model parameters are then regarded as a good representation ofthose of the actual reservoir.

Today’s computer-generated models provide much greater flexibility and improve the accuracyof the match between real and simulated data. It is now possible to compare an almost unlimitednumber of reservoir models with the observed data.

Figure 4. Outer boundary effects and effects of damage removal in pressure response curves.

101

100

10–1

10–2

10–3 10–2 10–1 100 101 102

Elapsed time (hr)

Pressure – pressure derivative (psi)

Before acid buildup

After acid buildup

Page 15: 01_introduction_to_testing_services

6

Test designDesign and implementation of a well testing program can no longer be conducted under standardor traditional rule-of-thumb guidelines. Increasingly sophisticated reservoir development andmanagement practices, stringent safety requirements, environmental concerns and a greaterneed for cost efficiency require that the entire testing sequence, from program design to dataevaluation, be conducted intelligently. Proper test design, correct handling of surface effluents,high-performance gauges, flexible downhole tools and perforating systems, wellsite validationand comprehensive interpretation are key to successful well testing.

The importance of clearly defined objectives and careful planning cannot be overstated.Design of a well test includes development of a dynamic measurement sequence and selection ofhardware that can acquire data at the wellsite in a cost-effective manner. Test design is bestaccomplished in a software environment where interpreted openhole logs, production optimiza-tion analysis, well perforation and completion design, and reservoir test interpretation modulesare simultaneously accessible to the analyst.

The first step in test design involves dividing the reservoir into vertical zones using openholelogs and geological data. The types of well or reservoir data that should be collected during thetest are then specified. The data to be collected determine the type of well test to be run (Table 1).

Page 16: 01_introduction_to_testing_services

Introduction to Testing Services ■ Introduction 7

Table 1. Summary of Different Test Types

Test Type Measurement Conditions Distinguishing Design

Flowing Shut-in Pulse Slug Characteristics Consideration

Closed-chamber test † ‡ ‡ Downhole shut-in Chamber and cushion lengths; valve open/shut sequence

Constant-pressure ‡ ‡ Requires transient flow Flow rate sensitivityflow test rate measurement

Drillstem test † ‡ Downhole shut-in; Flowing and shut-in sequence/ openhole or cased hole duration

Formation test ‡ ‡ Test conducted on Tool module sizing/selection; borehole wall; formation pressure sensitivityfluid sampling

Horizontal well test ‡ ‡ Testing hardware usually Minimize wellbore storage effects; located in vertical part requires long-duration testof hole

Impulse test ‡ ‡ Transients initiated by Trade-off between impulse short-rate impulse duration and pressure sensitivity

Multilayer transient test ‡ ‡ Multirate test; pressure Flow rate/pressure sensitivity; test and rate measured at sequence; measurement depthsseveral depths

Multiwell interference test ‡ ‡ † Transient induced in Test duration; pressure sensitivityactive well, measured in observation well

Pumped-well test ‡ Downhole pressure Downhole pressure sensor versus measured or computed surface acoustic devicefrom liquid-level soundings

Stabilized-flow test ‡ Includes isochronal, flow- Time to reach stabilizationafter-flow, inflow perfor-mance, production logs

Step-rate test ‡ Flow test to determine Flowing pressure range must injection well parting include parting pressurepressure

Testing while perforating ‡ ‡ ‡ Testing hardware and Underbalance determinationperforation guns on the same string

Transient rate and ‡ ‡ Downhole measurement Flow rate/pressure sensitivitypressure test of pressure, flow rate,

temperature and (usually) density

Vertical interference test † ‡ † Transient induced at one Test duration; pressure sensitivitydepth and measured at another

† = Under certain conditions‡ = Commonly conducted

Page 17: 01_introduction_to_testing_services

8

Once the type of test is determined, the sequence changes in surface flow rate that shouldoccur during the test are calculated. The changes in flow rate and their duration should be real-istic and practical so they generate the expected interpretation patterns in the test data. This isbest achieved by selecting an appropriate reservoir model and simulating the entire testsequence in advance (Figs. 5 and 6). Test sequence simulation allows exploring the entire rangeof possible pressure and flow rate measurements. Simulation also helps identify the types of sensors capable of measuring the expected ranges. Diagnostic plots of simulated data should beexamined to determine when essential features will appear, such as the end of wellbore storageeffects, duration of infinite-acting radial flow and start of total system response in fissured systems. The plots can also help anticipate the emergence of external boundary effects, includ-ing sealed or partially sealed faults and constant-pressure boundaries.

The next step is to generate sensitivity plots to determine the effects of reservoir parameterson the duration of different flow regimes.

The final step of the test design process is to select the instrumentation and equipment fordata acquisition. Surface and downhole equipment should be versatile to support safe, flexibleoperations. Key factors to consider include■ controlling the downhole environment to minimize wellbore storage■ using combined perforating and testing techniques to minimize rig time■ running ultra-high-precision gauges when test objectives call for a detailed reservoir description■ choosing reliable downhole recorders to ensure that the expected data will be retrieved when

pulling the tools out of hole■ selecting surface equipment to safely handle expected rates and pressures■ disposing of produced fluids in an environmentally acceptable manner.

Whatever the test design, it is important to ensure that all data are acquired with the utmostprecision. To do this, it is necessary to have a good understanding of the available hardwareoptions and any prospective impact on data quality.

Page 18: 01_introduction_to_testing_services

Introduction to Testing Services ■ Introduction 9

Figure 5. Simulated pressure response.

Elapsed time (hr)

Pressure (psia)

0 1 2 3 4

10,000

8000

6000

4000

Figure 6. Test design flow identification plot.

Elapsed time (hr)

Pressure – pressure derivative (psi)

106

105

104

103

102

101

10–4 10–2 100 102 104

Limits

Radial flow

Double-porosity behavior

Wellborestorage

PressureDerivative

Page 19: 01_introduction_to_testing_services

Introduction to Testing Services ■ Marks 11

Marks

Marks of Schlumberger

Mark Spelled-Out Version or Description

Commander control systems for subsea well control

CQG Crystal Quartz Gauge

DataLatch electrical wireline downhole recorder/transmitter

EverGreen minimal environmental impact well effluent burner

E-Z Tree retrievable well control tree

E-Z Valve retrievable well control valve

Green Dragon high-efficiency burner

HPR Hostile Environment Pressure Recorder

HSD High Shot Density gun system

IRIS Intelligent Remote Implementation System

LINC Latched Inductive Coupling tool

MFE Multiflow Evaluator tool

NODAL production system analysis

PCT Pressure Controlled Tester

PERFPAC sand control method

PhaseTester portable multiphase periodic well testing equipment

PORT Pressure Operated Reference Tool

PosiTest retrievable compression packer

Positrieve retrievable compression packer with hold-down section

QUANTUM gravel-pack packer family

RFT Repeat Formation Tester

Sandec sand-flow detection equipment

Sapphire pressure gauge

SenTREE subsea well control systems

SMART Schlumberger Modular Acquisition Recording Terminal

UNIGAGE pressure gauge system

Vx multiphase well testing technology

Page 20: 01_introduction_to_testing_services

12

Other Marks

Mark Company

Aflas® Registered trademark of Asahi Glass Co., Ltd.

Barton® Registered trademark of Barton Instrument Systems, LLC

Daniel® Registered trademark of Daniel Industries, Inc.

Floco® Registered trademark of Barton Instrument Systems, LLC

HASTELLOY® Registered trademark of Haynes International, Inc.

HP® Registered trademark of Hewlett-Packard Company

Kimray® Registered trademark of Kimray, Inc.

Lee Jeva® Registered trademark of Lee Company

Quartzdyne® Registered trademark of Quartzdyne Inc.

Ranarex® Registered trademark of EG&G Chandler Engineering Company

Rotron™ Trademark of Ametek, Inc.

Transaqua® Registered trademark of Castrol Limited

Unix® Registered trademark of The Open Group

Viton® Registered trademark of DuPont Dow Elastomers L.L.C.

Windows® Registered trademark of Microsoft Corporation

Windows NT® Registered trademark of Microsoft Corporation

Page 21: 01_introduction_to_testing_services

Introduction to Testing Services ■ Nomenclature 13

Nomenclature

A area

Ag gas cross-sectional area

a location of discontinuity in a composite reservoir

a pumping well hydrodynamic constant

aD dimensionless location of discontinuity in thecomposite reservoir

ADC analog-to-digital converter

ANSI American National Standards Institute

AOF absolute open flow

API American Petroleum Institute

ASCII American Standard Code for InformationInterchange

ASIC application-specific integrated circuit

ASME American Society of Mechanical Engineers

ASTM American Society for Testing and Materials

B formation volume factor

BHA bottomhole assembly

BHP bottomhole pressure

BOP blowout preventer

BOST Battery-Operated Shut-In Tool

BOV bleedoff valve

BWPD barrels of water per day

C concentration

C performance coefficient

C wellbore storage coefficient

CD dimensionless wellbore storage coefficient

CDf dimensionless fracture storage coefficient

Cd drag coefficient

ct total compressibility

CaBr calcium bromide

CCL casing collar log

CEC Commission for Environmental Cooperation

CENELEC Comité Européen de NormalisationElectrotechnique

CO2 carbon dioxide

CT coiled tubing

CTC convolution type curve

CTS cable telemetry system

CTU cumulative tool usage

CV circulating valve

D non-Darcy coefficient

dc casing diameter

dt tubing diameter

DAC digital-to-analog converter

DAV Dual-Action Valve

DGA DST gauge adapter

DHSIT downhole shut-in tool

dm droplet diameter

DNV Det Norske Veritas

DST drillstem test

DWLA DST LINC wireline adapter

DWT deadweight tester

EEPROM electrically erasable (user) programmableread-only memory

EFST explosive-free shut-in tool

ELMF enhanced liquid measurement flowmeter

EMC electromagnetic compatability

EN European standards

EOP extreme overbalanced perforating

Page 22: 01_introduction_to_testing_services

14

ERS Easy Record Software

ESD emergency shutdown

ESFA EFST actuator

EZGC subsea pressure and temperature carrier

EZTH latch assembly of SenTREE 3 system

EZTM SenTREE 3 system

EZTV valve assembly of SenTREE 3 system

EZV E-Z Valve

F number of flow steps

FCD dimensionless fracture conductivity

fg gas void fraction

FASC Fullbore Annular Sample Chamber

FCP flowhead control panel

FHH data header flowline tool

FLXH FlexPac hydraulic hold-down

FLXP FlexPac retrievable packer

FPM Formation Protection Module

GFI ground fault interruption

GLR gas/liquid ratio

GOR gas/oil ratio

GR gamma ray

GUI graphical user interface

GVF gas volume fraction

H2S hydrogen sulfide

h height or thickness

hb bottom nonopen interval length

hD dimensionless reservoir thickness

hL height of liquid level

hLF height of gas column

hp perforation interval

ht reservoir thickness excluding gas cap

hw well open interval length

hwd penetration ratio (hw/rw)

HAZOP Hazard and Operability

HCl hydrochloric acid

HF hydrofluoric acid

HOOP hold-open

HP high pressure

HPHT high pressure, high temperature

HPU hydraulic power unit

HSE health, safety and environment

ID inside diameter

IEC International Electrotechnical Commission

IRDV IRIS dual-valve tool

IPR inflow performance ratio

ISO International Standards Organization

k permeability

kf fracture permeability

kh horizontal permeability

kro relative permeability to oil

krw relative permeability to water

kv vertical permeability

kx directional permeability

ky directional permeability

kz directional permeability

kh permeability-thickness product (flow capacity)

khave average permeability-thickness product

L length

L number of layers

Lp horizontal well perforated interval

LCD liquid crystal display

LDCA DLWA/LINC downhole coupler assembly

LP low pressure

LRT layered reservoir testing

LRT LINC running tool

LRTC LINC running tool cartridge

LRTL LINC running tool latch

LSCI LINC surface computer interface

LUBV lubricator valve

M number of flow steps preceding the transient

Page 23: 01_introduction_to_testing_services

Introduction to Testing Services ■ Nomenclature 15

M mobility ratio

m(p) gas pseudopressure function

max maximum

MCCV multicycle circulating valve

MCS master control station

MCVL multicycle circulating valve with lock

min minimum

MIRV multiple-opening, internally operatedreversing valve

MQD mean quadratic deviation

MSDST multislickline downhole shut-in tool

MWPT measurements-while-perforating tool

n inertial effect exponent

NACE National Association of CorrosionEngineers

NACE NACE specifications for oilfield equipmentMR-01-75 material requirements

NAS National Aerospace Standard

NEC National Electrical Code

NPD Norwegian Petroleum Directorate

NPT National Pipe Thread

OD outside diameter

p pressure

p* extrapolated pressure at infiniteshut-in time

pa applied pressure

pc casing head pressure

pc computed pressure

pD dimensionless pressure

pDD drawdown pressure

pi initial pressure

pmax maximum pressure

pR reservoir pressure

pwbD dimensionless wellbore pressure

pwbf wellbore flowing pressure

pwD dimensionless wellbore pressure

pwDC convolved dimensionless wellbore pressure

pwf wellbore flowing pressure at a constantflow rate

pwi initial wellbore pressure

pws bottomhole shut-in pressure

p0 arbitrary reference pressure

PC personal computer

PCTV PCT valve

PFSV pump-through flapper safety valve

PIPK Positrieve packer

PowerLINC power-latched inductive coupling

PSPC compression-set PosiTest packer

PSPK PosiTest cased hole packer

PTSV pump-through safety valve

PTV pipe tester valve

PVT pressure-volume-temperature

Q capacity

Qo oil capacity

q flow rate

qD dimensionless flow rate

qg flow rate of gas

qin flow rate into a closed chamber

qout flow rate out of a closed chamber

qr constant surface flow rate

qs sandface flow rate

qt total flow rate

qwbf wellbore flow rate

r radial distance

rD dimensionless radial distance

reD dimensionless reservoir outer radius

reH dimensionless inner radius of horizontalflow region

reV dimensionless outer radius of verticalflow region

rf radial distance to the fluid front

rtD dimensionless radial distance to the fluid front

rw wellbore radius

Page 24: 01_introduction_to_testing_services

16

RA radioactive

Re Reynolds number

RETV retainer valve in SenTREE 3 system

RIH running in hole

RSM riser sealing mandrel

S saturation

s skin factor

s′ pseudoskin factor

S.A. Stub Acme

SAM subsea accumulator module

S.A.T. Safety Analysis Table

SBSA SMART Basic Services Acquisition

SBSV single-ball safety valve

SCM subsea control module

SCPU SMART Central Processing Unit

SCSSV surface-controlled subsurface safetyvalve

SCTT subsea completion and test tree

SCU surface control unit

SFRCT sandface rate-convolution type function

SHORT single-shot hydrostatic overpressurereverse tool

SHRT hydrostatic reference tool

SHRV single-shot hydrostatic overpressurereverse tool

SHRV-T single-shot hydrostatic overpressurereverse valve (internal/external)

SIP selective inflow performance

SJB safety joint

SLPJ slip joint

Sn sensor output

SORTIE single-shot hydrostatic overpressurereverse valve (internal/external)

SPV shear pin valve

SRC Schlumberger Reservoir CompletionsCenter

SRO surface readout

SSJ subsea spanner joint

SSV surface safety valve

STAF surface testing acquisition front end

STAN surface testing acquisition network

SXAR explosive automatic gun release sub

T temperature

T time starting with the first flow rate

t time

ta gas pseudotime function

tD dimensionless time

tDf dimensionless time for fractured well

ti interval time

tp production time before shut-in

t0 starting time

t0 time corresponding to the arbitraryreference pressure p0

TCP tubing-conveyed perforating

TFTV tubing fill/test valve

THRT tubing hanger running tool

TTP through-tubing perforation

TTV tubing test valve

UPP universal pressure platform

UPS uninterruptible power supply

V volume

Vc critical velocity

Vs settling velocity

w width

wD dimensionless width

WCQR UNIGAGE CQG sensor

WP working pressure

WT working temperature

xD dimensionless distance

xe reservoir length

xw distance from a boundary to the well

yD dimensionless distance

ye reservoir length

Page 25: 01_introduction_to_testing_services

Introduction to Testing Services ■ Introduction 17

yw distance from a boundary to the well

Z gas compressibility factor

z gas deviation factor

zw distance from a boundary to the well

ZnBr zinc bromide

α characteristic front constant in a two-bank model system

α fault barrier parameter

γ total compressibility ratio in a two-bank model system

γ pressure gradient

γL pressure gradient of liquid

γg pressure gradient of gas

Δ difference

Δp change in pressure

Δp/Δq rate-normalized pressure

Δq change in rate

Δt elapsed time

Δti elapsed time interval

η diffusivity constant (k/φctμ)

θ angle between two intersecting boundaries

κ permeability ratio (k1h1/[k1h1 + k2h2])

λ interporosity pseudosteady-state flow parameter

μ viscosity

μg gas viscosity

μl liquid viscosity

μo oil viscosity

μw water viscosity

ρg gas density

ρl liquid density

τ superposition time

φ porosity

ω storativity ratio