Post on 29-Jan-2021
schneider-electric.com
Catalog | March 2020
Interface, miniature and power electromechanical relays
Zelio Electromechanical Relays
http://www.schneider-electric.com
Discover HarmonyAdvanced operator interface and industrial relaysHarmony operator interface and industrial relays enhance operational efficiency and equipment availability across industrial and building applications. Harmony includes intelligent connected products and edge terminals that visualize, gather and process data, enabling informed operator decisions
Explore our offer - Harmony Push Buttons and Switches - Harmony HMI Operator Terminals, IPC and EdgeBox - Harmony Signaling Devices - Harmony Electrical Relays - Harmony Safety
Harmony
https://www.se.com/ww/en/work/products/master-ranges/harmonyhttps://www.se.com/ww/en/work/products/master-ranges/harmony#Harmony Push Buttons and Switcheshttps://www.se.com/ww/en/work/products/master-ranges/harmony#Harmony HMI Operator Terminals, IPC and EdgeBoxhttps://www.se.com/ww/en/work/products/master-ranges/harmony#Harmony Signaling Deviceshttps://www.se.com/ww/en/work/products/master-ranges/harmony#Harmony Electrical Relayshttps://www.se.com/ww/en/work/products/master-ranges/harmony#Harmony Safety
Find your catalog
> With just 3 clicks, you can reach the Industrial Automation and Control catalogs, in both English and French > Download Digi-Cat with this link
Select your training
> Find the right Training for your needs on our Global website > Locate the training center with the selector tool, using this link
Quick access to product information
Get technical information about your product
• Updated quarterly• Embeds product selectors and configurators,
360° images, training centers,• Optimized search by commercial reference
Each commercial reference presented in a catalog contains a hyperlink. Click on it to obtain the technical information of the product:
– Characteristics, Dimensions and drawings, Mounting and clearance, Connections and schemas, Performance curves
– Product image, Instruction sheet, User guide, Product certifications, End of life manual
https://www.youtube.com/embed/9Nv2zUuX69g?autoplay=1https://digicat.se.com/https://www.schneider-electric.com/en/work/services/training/http://www.schneider-electric.com/b2b/en/services/training/technical-training.jsp
1
General contents
General presentation and selection guide
Plug-in relays and relays with clamp fixing
Product reference index . . . . . . . . . . . . . . .
2
1
3
4
5
6
7
8
9
10
2
1
4
5
6
7
8
9
10
1/0
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
1/1
Contents
Zelio Electromechanical Relaysb General presentation
v RSL relays for compactness ................................................................. page 1/2
v RXG relays for reliability ....................................................................... page 1/2
v RXM relays for automation control ....................................................... page 1/3
Selection guide of Plug-in relays and relays with clamp fixing . . . . . . . page 1/4
General presentation and selection guide
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
1/2
Zelio Relay - Electromechanical Relays Used to multiply the number of input and output contacts, or for logic processing control
Zelio Relays offer interface, miniature, universal, and power electromenchanical relays, from 1 CO to 4 CO contacts, up to 30 A. The electromechanical relays help to reduce the size of enclosures and at the same time increase machine reliability.
RSL relays for compactnessFlexible offer> Available as a single-referenced complete product (relay and socket) or
customer-assembled product
> Wide choice of sockets ranging from 12 to 230 V a> Standard and low level contact types
Enhanced performance> Sockets with integrated reverse polarity protection circuit> Relays for high breaking capacity or low-level current application requirements> Power-on and Relay status LED indicator
Simple installation and cabling> Locking/unlocking lever for removing and replacing the relay in the socket> Simple DIN rail mounting and commoning link accessory> Choice of screw connector or spring terminal connection for sockets
RXG relays for reliabilityComplete offerRXG relays offer a broad range of coil voltages, from 6 V to 110 V c and 24 V to 230 V a. The relays are available with/without lockable test button, LED, and clear cover.
Easy to mount and use These are the latest relays with a single-step lockable test button. The Faston pin terminal mounts quickly and securely. The slim 16 mm/0 .629 in . socket for 2 CO saves panel space.
General presentation Zelio Electromechanical RelaysRSL slim and RXG interface relays
LED indicator for RSL relay status
Zelio Relay RXG Latest interface relay with easy testing function
RSL relays are compact modular relays conforming to IEC/EN 61810-1, UL508, CSA C22.2 No. 14, and EAC international standards.
Single-step lockable test button
Spring terminalScrew connector
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
1/3
RXG relays for reliability (continued)Expandable relays RXG relays can be expanded with protection modules such as diode, diode with LED, varistor with LED, and RC circuit.
RXM relays for automation controlEasy to select > Wider choice of contacts (2, 3, and 4 CO)> Broad range of control circuit voltages and different socket types> Configurator available in Apple App and Android Play Store
Convenient to use> One-step lockable test button> Mechanical indicator for contact status> “Power On” LED for readiness
Simple to install> Push and stay spring clamp socket wiring (no screwdriver required) provides up
to 65% time saving> Sockets for both DIN rail and panel mounting, time-saving bus jumper> Direct mounting with DIN rail or flange adapter
Designed to perform> Eco-design with RoHS and REACH> Flexible add-on protection modules> Spring clamp socket with 20 kg/44 lb wire pull-out force and reliable retention
force on cables
General presentation (continued)
Zelio Electromechanical RelaysRXG interface and RXM miniature relays
Zelio Relay RXM Miniature in size and powerful in performance
Push and stay spring clamp terminal: insert without tool
LED indicator for relay status
RXM relays industrial relays bring features for easy and improved control of simple and complex automation systems.
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
1/4 1/51/4
Zelio Electromechanical relaysPlug-in relays and relays with clamp fixing
Selection guide 3
Type of product Plug-in relays Plug-in relaysSlim interface relays Interface relays
Number and type of contacts/conventional thermal current (Ith on NO contact)
1 CO / 6 A 1 CO / 16 A1 CO / 12 A2 CO / 8 A
1 CO / 10 A 2 CO / 5 A
Control circuit voltage a - 24…240 V 24…230 Vc 12…60 V 6…110 V 6…110 V
Pin type Flat (PCB type, reinforced) Flat (PCB type) Flat (Faston type)Operational voltage Up to 400 V a/300 V c Up to 400 V a/300 V c Up to 250 V a/cDurability (operating cycles per hour)
Electrical, resistive load 60,000 100,000 100,000Mechanical, no-load 10,000,000 30,000,000 10,000,000 for AC coil
10,000,000 for DC coilFunctions LED No Yes (with protection modules) Yes (depending on version)
Mechanical indicator No No Yes (depending on version)Lockable test button No No Yes (depending on version)Contact type Standard and low level Standard Standard
Type references RSL1pB4pD (1) RSBppppppp (1) RXGpppp (1)Pages 2/3 2/5 2/9
Type of associated sockets Sockets with LED and protection circuit Sockets without LED Sockets
Contact terminal arrangements Separate Separate Separate
Connection Screw connector Spring terminals Screw connector Push-in terminals Screw connector Push-in terminals
Accessories Protection modules No No Yes Yes Yes YesTimer module No No No No No NoMaintaining clamps No No Yes Yes (plastic, integrated) Yes (plastic, integrated) Yes (plastic, integrated)Socket identification legend Yes Yes Yes Yes Yes YesMounting adapters for DIN rail No No No No No NoMounting adapters with fixing lugs No No No No No NoBus jumper Yes, 20-pole Yes, 20-pole Yes Yes, 2-pole Yes Yes, 2-pole
Conventional thermal current (Ith) 6 A 6 A 12 A (2 terminals) × 10 A (2)
12 A 10 A 10 A for 1 CO 5 A for 2 CO 10 A 5 A
Type references RSLZVpp RSLZRpp RSZE1S35M RSZE1S48M RSZE05P RSZE08P RGZE1S35M RGZE1S48M RGZE05P RGZE08PPages 2/3 2/5 2/10(1) Pre-assembled interface relays RSL1PVpp and RSL1PRpp (standard type relay + socket), RSB (relay + socket + clamp + protection module + label), and
RXG (relay + socket + protection module) are also available .(2) When using relay RSB1A160pp with socket RSZE1S48M, terminals must be linked .
https://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RGZE1S35Mhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE05Phttps://www.schneider-electric.com/en/product/RSZE08Phttps://www.schneider-electric.com/en/product/RGZE05Phttps://www.schneider-electric.com/en/product/RGZE08P
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
1/71/6
Type of product Plug-in relays Plug-in relays Relays with clamp fixingMiniature relays Power relays Universal relays Power relays
Number and type of contacts/conventional thermal current (Ith on NO contact)
2 CO / 12 A3 CO / 10 A4 CO / 6 A4 CO / 3 A (low level)
1 CO / 15 A2 CO / 15 A3 CO / 15 A4 CO / 15 A
2 CO / 10 A3 CO / 10 A
2 CO / 10 A3 CO / 10 A
2 NO / 30 A (4)2 CO / 30 A (4)
Control circuit voltage a 24…240 V 24…230 V
c 12…220 V 12…110 V 12…220 V 12…110 V 12…24 V
Pin type Flat (Faston type) Flat (Faston type) Cylindrical Flat (Faston type) Flat (Faston type)
Operational voltage Up to 250 V a/c Up to 250 V a/c Up to 250 V a/c100,000
Up to 250 V a/c
Durability (operating cycles per hour)
Electrical, resistive load 100,000 100,000 (3) 100,000Mechanical, no-load 10,000,000 10,000,000 5,000,000 5,000,000
Functions LED Yes (depending on version) Yes (depending on version) Yes (depending on version) –Mechanical indicator Yes Yes Yes –Lockable test button Yes Yes YesContact type Low level (depending on version) Standard Low level (depending on version) Standard –
Type references RXMpppppp (1) RPMpppp RUMppppp RPFppppPages 2/13 2/23 2/19 2/27
Type of associated sockets Sockets without LED Sockets without LED Sockets without LED
Contact terminal arrangements Mixed Separate Mixed Mixed Separate –
Connection Screw connector Screw clamp terminals
Screw connector Push-in terminals Screw clamp terminals Screw connector –
Accessories Protection modules Yes Yes Yes Yes Yes –Timer module No No No Yes (for 3- and 4-pole) Yes –Maintaining clamps Yes Yes Yes (plastic, integrated) Yes (on socket RPZF1) Yes –
Socket identification legend Yes No Yes Yes Yes Yes –Mounting adapters for DIN rail Yes Yes Yes Yes No –Mounting adapters with fixing lugs Yes Yes Yes Yes No –Bus jumper No Yes, 2-pole (Ith = 5 A) Yes, 2-pole No No Yes, 2-pole (Ith = 5 A) –
Conventional thermal current (Ith) 10 A 10 A 12 A for 2 CO (2)6 A for 4 CO
12 A for 2 CO 6 A for 4 CO
16 A 12 A –
Type references RXZE2M114M RXZE2M114 RXZE2SpppM RXZE14P RPZFp RUZCpM RUZSCpM RUZSF3M –
Pages 2/15 2/24 2/19 –(1) Pre-assembled miniature relays RXM (relay + socket + clamp + label) are also available . (2) Except for sockets RXZE2S11pM: 10 A .
(3) 100,000 for RPM1 and RPM2; 60,000 for RPM3 and RPM4 .(4) 30 A when mounted with 13 mm (0 .51 in .) gap between two relays and 25 A when mounted side by side without a gap .
Zelio Electromechanical RelaysPlug-in relays and relays with clamp fixing
Selection guide (Continued) 3
https://www.schneider-electric.com/en/product/RXZE14Phttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2M114https://www.schneider-electric.com/en/product/RUZSF3Mhttps://www.schneider-electric.com/en/product/RPZF1
2/0
Contents
RSL slim interface relays b Presentation
v Presentation of the range ......................................................................... page 2/2
v Relay description ..................................................................................... page 2/2
v Socket description ................................................................................... page 2/2
b References
v Pre-assembled slim interface relays ........................................................ page 2/3
v Slim interface relays for customer assembly ............................................ page 2/3
v Accessories for sockets ........................................................................... page 2/3
RSB interface relays b Presentation v Presentation of the range ......................................................................... page 2/4 v Socket description ................................................................................... page 2/4
b References ............................................................................................. page 2/5
v Pre-assembled interface relays ............................................................... page 2/5
v Interface relays for customer assembly ................................................... page 2/6
v Sockets with separate contact terminal arrangement and connector connection ........................................................................ page 2/6
v Protection modules .................................................................................. page 2/6
v Accessories ............................................................................................. page 2/5
RXG interface relays b Presentation
v Presentation of the range ......................................................................... page 2/8
v Relay description ..................................................................................... page 2/8
v Socket description ................................................................................... page 2/8
b References ............................................................................................. page 2/9
v Pre-assembled interface relays ............................................................... page 2/9
v Interface relays for customer assembly ................................................... page 2/9
v Sockets with separate contact terminals, screw connector connection,and built-in clamp ......................................page 2/11
v Protection modules .................................................................................page 2/11
v Accessories ............................................................................................page 2/11
RXM miniature relays b Presentation
v Presentation of the range ....................................................................... page 2/12
v Relay description ................................................................................... page 2/12
v Socket description ................................................................................. page 2/12
b References ........................................................................................... page 2/13
v Pre-assembled interface relays ............................................................. page 2/13
v Miniature relays for customer assembly ................................................. page 2/14
v Sockets .................................................................................................. page 2/15
v Protection modules ................................................................................ page 2/15
v Timing relays ......................................................................................... page 2/15
v Accessories ........................................................................................... page 2/15
Plug-in relays and relays with clamp fixing
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2/1
Contents (continued) Plug-in relays and relays with clamp fixing
RUM universal relays b Presentation
v Presentation of the range ....................................................................... page 2/18
v Relay description ................................................................................... page 2/18
v Socket description ................................................................................. page 2/18
b References ........................................................................................... page 2/19
v Universal relays for customer assembly ................................................ page 2/19
v Sockets .................................................................................................. page 2/20
v Protection modules ................................................................................ page 2/20
v Timer module ......................................................................................... page 2/20
v Timing relays ......................................................................................... page 2/20
v Accessories ........................................................................................... page 2/21
RPM power relays b Presentation
v Presentation of the range ....................................................................... page 2/22
v Relay description ................................................................................... page 2/22
v Socket description ................................................................................. page 2/22
b References ........................................................................................... page 2/23
v Power relays for customer assembly ..................................................... page 2/23
v Sockets .................................................................................................. page 2/24
v Protection modules ................................................................................ page 2/24
v Timer module ......................................................................................... page 2/24
v Accessories ........................................................................................... page 2/25
RPF power relays b Presentation ......................................................................................... page 2/26
b References ........................................................................................... page 2/27
Technical presentation b Relays ................................................................................................... page 2/28
b Protection modules ............................................................................. page 2/29
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2/22/2
Presentation Zelio Electromechanical RelaysPlug-in relaysRSL slim interface relays
Presentation of the rangeRSL slim interface relays offer the advantages of compact size and modular design. Their slim width (6 mm/0 .236 in .) saves space when mounting on a DIN rail at the back of an enclosure.
RSL relays are available as: b Pre-assembled offer: a single reference comprising a standard relay mounted on
its socket. v The socket includes a protection circuit (against reverse polarity and surge) and
an LED indicator as standard. v 2 types of connector are available for wire connection: screw connectors or spring
terminals. v This pre-assembled solution covers a wide range of operating voltages from 12 to
230 V. b Customer assembly offer: v The relay (standard or low level) and the socket are selected, as required,
according to the operating voltage of the application. v For maintenance, an RSL slim relay can be replaced without disconnecting the
socket wiring.
Relay descriptionRSL slim interface relays, pre-assembled
1 6 A standard relay with 1 CO contact2 Lever for retaining or easy withdrawal of the relay from its socket 3 Sockets: wire connection by screw connectors or spring terminals4 Built-in protection circuit and LED indicator on all sockets
RSL slim interface relay
1 5 flat (PCB type) standard pins
Socket descriptionSockets for RSL slim interface relays
1 5 female contacts for the relay pins2 Retaining lever with marker label3 Wire connection by screw connectors or spring terminals4 Built-in protection circuit and LED indicator5 Locating slot for mounting on DIN rail
1
2
3
4
1
1
24
5
3
2
1
3
4
5
6
7
8
9
10
2/32/3
Pre-assembled slim interface relaysStandard relays mounted on socket equipped with LED and protection circuit1 CO contact - Thermal current (Ith) 6AOperating voltage V
Control circuit voltageV
Socket typeScrew connector Spring terminalUnit reference Weight
kg/lbUnit reference Weight
kg/lb
c/a 12 c 12 RSL1PVJU (RSL1AB4JD + RSLZVA1)
0.031/0 .068 RSL1PRJU (RSL1AB4JD + RSLZRA1)
0.029/0 .064
c/a 24 c 24 RSL1PVBU (RSL1AB4BD + RSLZVA1)
0.031/0 .068 RSL1PRBU (RSL1AB4BD + RSLZRA1)
0.029/0 .064
c/a 48 c 48 RSL1PVEU (RSL1AB4ED + RSLZVA2)
0.031/0 .068 RSL1PREU (RSL1AB4ED + RSLZRA2)
0.029/0 .064
c/a 110 c 60 RSL1PVFU (RSL1AB4ND + RSLZVA3)
0.031/0 .068 RSL1PRFU (RSL1AB4ND + RSLZRA3)
0.029/0 .064
c/a 230 c 60 RSL1PVPU (RSL1AB4ND + RSLZVA4)
0.031/0 .068 RSL1PRPU (RSL1AB4ND + RSLZRA4)
0.029/0 .064
Slim interface relays for customer assemblyRelays with flat (PCB type) standard pins1 CO contact - Thermal current (Ith) 6A
Standard Low levelControl circuit voltageV
Unit reference Weightkg/lb
Unit reference Weightkg/lb
c 12 RSL1AB4JD 0.006/0 .013 RSL1GB4JD 0.006/0 .013
c 24 RSL1AB4BD 0.006/0 .013 RSL1GB4BD 0.006/0 .013
c 48 RSL1AB4ED 0.006/0 .013 RSL1GB4ED 0.006/0 .013
c 60 RSL1AB4ND 0.006/0 .013 RSL1GB4ND 0.006/0 .013
Sockets equipped with LED and protection circuitSold in lots of 10Operating voltageV
For use with relays
Socket typeScrew connector Spring terminalUnit reference Weight
kg/lbUnit reference Weight
kg/lb
c/a 12 and c/a 24 RSL1pB4JDRSL1pB4BD
RSLZVA1 0.025/0 .055 RSLZRA1 0.023/0 .051
c/a 48 and c/a 60 RSL1pB4EDRSL1pB4ND
RSLZVA2 0.025/0 .055 RSLZRA2 0.023/0 .051
c/a 110 RSL1pB4ND RSLZVA3 0.025/0 .055 RSLZRA3 0.023/0 .051
c/a 230 RSL1pB4ND RSLZVA4 0.025/0 .055 RSLZRA4 0.023/0 .051
Socket accessoriesDescription For use with Reference Weight
kg/lbClip-in legends(2 sheets of 64 legends)
All sockets RSLZ5 0.001/0 .002
Bus jumper (10 x 20-pole jumper)
All sockets RSLZ2 0.003/0 .007
Partition plate(10 partition plates)
All sockets RSLZ3 0.001/0 .002
RSL1AB4ND
PF12
0931
RSL1PVBU
PF12
0937
RSLZVAp
PF09
0209
RSLZRAp
PF09
0210
RSL1PRPU
PF12
0938
References Zelio Electromechanical RelaysPlug-in relaysRSL slim interface relays
PF12
1806
RSLZ2
PF12
1804
RSLZ3
https://www.schneider-electric.com/en/product/RSL1AB4JDhttps://www.schneider-electric.com/en/product/RSL1AB4BDhttps://www.schneider-electric.com/en/product/RSL1AB4EDhttps://www.schneider-electric.com/en/product/RSL1AB4NDhttps://www.schneider-electric.com/en/product/RSL1AB4NDhttps://www.schneider-electric.com/en/product/RSL1GB4JDhttps://www.schneider-electric.com/en/product/RSL1GB4BDhttps://www.schneider-electric.com/en/product/RSL1GB4EDhttps://www.schneider-electric.com/en/product/RSL1GB4NDhttps://www.schneider-electric.com/en/product/RSL1PRJUhttps://www.schneider-electric.com/en/product/RSL1PRBUhttps://www.schneider-electric.com/en/product/RSL1PREUhttps://www.schneider-electric.com/en/product/RSL1PRFUhttps://www.schneider-electric.com/en/product/RSL1PRPUhttps://www.schneider-electric.com/en/product/RSLZRA1https://www.schneider-electric.com/en/product/RSLZRA1https://www.schneider-electric.com/en/product/RSLZRA2https://www.schneider-electric.com/en/product/RSLZRA3https://www.schneider-electric.com/en/product/RSLZRA4https://www.schneider-electric.com/en/product/RSLZRA1https://www.schneider-electric.com/en/product/RSLZRA2https://www.schneider-electric.com/en/product/RSLZRA3https://www.schneider-electric.com/en/product/RSLZRA4https://www.schneider-electric.com/en/product/RSLZ5https://www.schneider-electric.com/en/product/RSLZ2https://www.schneider-electric.com/en/product/RSLZ3https://www.schneider-electric.com/en/product/RSL1AB4JDhttps://www.schneider-electric.com/en/product/RSL1AB4BDhttps://www.schneider-electric.com/en/product/RSL1AB4EDhttps://www.schneider-electric.com/en/product/RSL1AB4NDhttps://www.schneider-electric.com/en/product/RSL1AB4NDhttps://www.schneider-electric.com/en/product/RSL1AB4JDhttps://www.schneider-electric.com/en/product/RSL1AB4BDhttps://www.schneider-electric.com/en/product/RSL1AB4EDhttps://www.schneider-electric.com/en/product/RSL1AB4NDhttps://www.schneider-electric.com/en/product/RSL1AB4NDhttps://www.schneider-electric.com/en/product/RSL1PVJUhttps://www.schneider-electric.com/en/product/RSL1PVBUhttps://www.schneider-electric.com/en/product/RSL1PVEUhttps://www.schneider-electric.com/en/product/RSL1PVFUhttps://www.schneider-electric.com/en/product/RSL1PVPUhttps://www.schneider-electric.com/en/product/RSL1PVBUhttps://www.schneider-electric.com/en/product/RSL1PRPUhttps://www.schneider-electric.com/en/product/RSLZVA1https://www.schneider-electric.com/en/product/RSLZVA1https://www.schneider-electric.com/en/product/RSLZVA2https://www.schneider-electric.com/en/product/RSLZVA3https://www.schneider-electric.com/en/product/RSLZVA4https://www.schneider-electric.com/en/product/RSLZVA1https://www.schneider-electric.com/en/product/RSLZVA2https://www.schneider-electric.com/en/product/RSLZVA3https://www.schneider-electric.com/en/product/RSLZVA4https://www.schneider-electric.com/en/product/RSLZ2https://www.schneider-electric.com/en/product/RSLZ3
2/4
Presentation of the rangeThe RSB interface relay range comprises: 1 12 A relays with 1 CO contact , 16 A relays with 1 CO contact, and 8 A relays with 2
CO contacts2 Sockets with separate contact terminals3 Protection modules (diode, diode + LED, RC circuit, or varistor + LED) common to
all sockets4 A plastic maintaining clamp for all sockets5 Clip-in legend for all sockets
These relays are available in both pre-assembled (single reference) and customer assembled offers.
Socket descriptionSockets with separate contact terminals (1)
1 a Connection by connector b Connection by push-in terminal2 5 or 8 female contacts for the relay pins3 Hole for panel mounting4 Location for protection modules5 a Locking components for plastic maintaining clamp b Built-in plastic maintaining clamp for locking components6 Locating slot for mounting on DIN rail7 Test point8 Push button to release wire9 Location for bus jumpers
(1) The inputs and outputs are separate from the relay supply .
Zelio Electromechanical RelaysPlug-in relaysRSB interface relays
Presentation
5
4
1
2
3
2
5b
6 9
Inputs
1b
Outputs
Relay supply
1a
2
35a
6
4
478
Inputs
Outputs
Relay supply
1
2
3
4
5
6
7
8
9
10
2/5
Pre-assembled interface relaysRelays mounted on sockets with protection module (LED version) and integrated clamp (sold in lots of 30)Control circuit voltageV
Number and types of contact - Thermal current (Ith)1 CO - 12 A 1 CO - 16 A 2 CO- 8 AUnit Reference Weight
kg/lbUnit Reference Weight
kg/lbUnit Reference Weight
kg/lb
12 c RSB1A120JDPV(RSB1A120JD + RSZE1S35M + RSZR215 + RZM031RB + RSZL300)
0.050/ 0 .110
RSB2A080JDPV(RSB2A080JD + RSZE1S48M + RSZR215 + RZM031RB + RSZL300)
0.057/ 0 .126
24 c RSB1A120BDPV(RSB1A120BD + RSZE1S35M + RSZR215 + RZM031RB + RSZL300)
0.050/ 0 .110
RSB1A160BDPV(RSB1A160BD + RSZE1S48M + RSZR215 + RZM031RB + RSZL300)
0.057/ 0 .126
RSB2A080BDPV(RSB2A080BD + RSZE1S48M + RSZR215 + RZM031RB + RSZL300)
0.057/ 0 .126
24 a RSB1A120B7PV(RSB1A120B7 + RSZE1S35M + RSZR215 + RZM021RB + RSZL300)
0.050/ 0 .110
RSB2A080B7PV(RSB2A080B7 + RSZE1S48M + RSZR215 + RZM021RB + RSZL300)
0.057/ 0 .126
120 a RSB1A120F7PV(RSB1A120F7 + RSZE1S35M + RSZR215 + RZM021FP + RSZL300)
0.050/ 0 .110
RSB2A080F7PV(RSB2A080F7 + RSZE1S48M + RSZR215 + RZM021FP + RSZL300)
0.057/ 0 .126
220 a RSB2A080M7PV (RSB2A080M7 + RSZE1S48M + RSZR215 + RZM021FP + RSZL300)
0.057/ 0 .126
230 a RSB1A120P7PV(RSB1A120P7 + RSZE1S35M + RSZR215 + RZM021FP + RSZL300)
0.050/ 0 .110
RSB1A160P7PV(RSB1A160P7 + RSZE1S48M + RSZR215 + RZM021FP + RSZL300)
0.057/ 0 .126
RSB2A080P7PV(RSB2A080P7 + RSZE1S48M + RSZR215 + RZM021FP + RSZL300)
0.057/ 0 .126
Zelio Electromechanical RelaysPlug-in relaysRSB interface relays
ReferencesR
S_53
2_C
PMFS
1808
5B
RSB2A080F7PV
1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RSB2A080JDPVhttps://www.schneider-electric.com/en/product/RSB2A080BDPVhttps://www.schneider-electric.com/en/product/RSB2A080B7PVhttps://www.schneider-electric.com/en/product/RSB2A080F7PVhttps://www.schneider-electric.com/en/product/RSB2A080M7PVhttps://www.schneider-electric.com/en/product/RSB2A080P7PVhttps://www.schneider-electric.com/en/product/RSB2A080JDhttps://www.schneider-electric.com/en/product/RSB2A080BDhttps://www.schneider-electric.com/en/product/RSB2A080B7https://www.schneider-electric.com/en/product/RSB2A080F7https://www.schneider-electric.com/en/product/RSB2A080M7https://www.schneider-electric.com/en/product/RSB2A080P7https://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM021RBhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSB1A120JDPVhttps://www.schneider-electric.com/en/product/RSB1A120BDPVhttps://www.schneider-electric.com/en/product/RSB1A160BDPVhttps://www.schneider-electric.com/en/product/RSB1A120B7PVhttps://www.schneider-electric.com/en/product/RSB1A120F7PVhttps://www.schneider-electric.com/en/product/RSB1A120P7PVhttps://www.schneider-electric.com/en/product/RSB1A160P7PVhttps://www.schneider-electric.com/en/product/RSB2A080F7PVhttps://www.schneider-electric.com/en/product/RSB1A120JDhttps://www.schneider-electric.com/en/product/RSB1A120BDhttps://www.schneider-electric.com/en/product/RSB1A160BDhttps://www.schneider-electric.com/en/product/RSB1A120B7https://www.schneider-electric.com/en/product/RSB1A120F7https://www.schneider-electric.com/en/product/RSB1A120P7https://www.schneider-electric.com/en/product/RSB1A160P7https://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM021RBhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300
2/6
Zelio Electromechanical RelaysPlug-in relaysRSB interface relays
References (continued)
Interface relays for customer assemblyRSB interface relays for standard applications (sold in lots of 10)Control circuit voltageV
Number and type of contacts - Thermal current (Ith)1 CO - 12 A 1 CO - 16 A 2 CO - 8 AUnit reference
Unit reference
Unit reference
Weightkg/lb
c 6 RSB1A120RD RSB1A160RD RSB2A080RD 0.014/0 .031
c 12 RSB1A120JD RSB1A160JD RSB2A080JD 0.014/0 .031
c 24 RSB1A120BD RSB1A160BD RSB2A080BD 0.014/0 .031
c 48 RSB1A120ED RSB1A160ED RSB2A080ED 0.014/0 .031
c 60 RSB1A120ND RSB1A160ND RSB2A080ND 0.014/0 .031
c 110 RSB1A120FD RSB1A160FD RSB2A080FD 0.014/0 .031
a 24 RSB1A120B7 RSB1A160B7 RSB2A080B7 0.014/0 .031
a 48 RSB1A120E7 RSB1A160E7 RSB2A080E7 0.014/0 .031
a 120 RSB1A120F7 RSB1A160F7 RSB2A080F7 0.014/0 .031
a 220 RSB1A120M7 RSB1A160M7 RSB2A080M7 0.014/0 .031
a 230 RSB1A120P7 RSB1A160P7 RSB2A080P7 0.014/0 .031
a 240 RSB1A120U7 RSB1A160U7 RSB2A080U7 0.014/0 .031
Sockets with separate contact terminal arrangement and screw connector connectionRated insulation voltage
Thermal current (Ith)
Relay type Sold in lots of
Unit reference
Weightkg/lb
a 250 V 12 A RSB1A120pp 10 RSZE1S35M 0.060/0 .132
10 A (1) RSB1A160pp (2)RSB2A080pp
10 RSZE1S48M 0.050/0 .110
Sockets with separate contact terminal arrangement, push in terminals, and built-in clampRated insulation voltage
Thermal current (Ith)
Relay type Sold in lots of
Unit reference
Weightkg/lb
a 250 V 12 A RSB1Appppp 10 RSZE05P 0.037/0 .082
10 A RSB2Appppp 10 RSZE08P 0.042/0 .093
Protection modulesDescription For
use withVoltageV
Sold in lots of
Unit reference
Weightkg/lb
Diode All sockets c 6…230 10 RZM040W 0.003/0 .007
RC circuit All sockets a 24…60 10 RZM041BN7 0.010/0 .022
a 110…240 10 RZM041FU7 0.010/0 .022
Diode + green LED All sockets c 6…24 10 RZM031RB 0.004/0 .009
c 24…60 10 RZM031BN 0.004/0 .009
c 110…230 10 RZM031FPD 0.004/0 .009
Varistor + green LED All sockets c or a 6…24 10 RZM021RB 0.005/0 .011
c or a 24…60 10 RZM021BN 0.005/0 .011
c or a 110…230 10 RZM021FP 0.005/0 .011
(1) RSZE1S48M is a two terminal socket each carrying 10 A .(2) If RSZE1S48M /RSZE08P socket terminals are linked, relay RSB1A160pp can be used up to 16 A . See “Wiring diagrams” on
www .schneider-electric .com .Note: Starting from 2020, Zelio Relays range name will change to Harmony Relays. As the timeline for each range is different,
there will be both Zelio and Harmony range during the transition period .
PF15
3636
A
RSB1A120JD + RZM031RB + RSZE1S35M
PF15
3646
A
RSB1A160JD + RSZE1S48M
XBK_
CP1
9314
D
RSZE05P
1
2
3
4
5
6
7
8
9
10
http://www.schneider-electric.comhttps://www.schneider-electric.com/en/product/RSB2A080RDhttps://www.schneider-electric.com/en/product/RSB2A080JDhttps://www.schneider-electric.com/en/product/RSB2A080BDhttps://www.schneider-electric.com/en/product/RSB2A080EDhttps://www.schneider-electric.com/en/product/RSB2A080NDhttps://www.schneider-electric.com/en/product/RSB2A080FDhttps://www.schneider-electric.com/en/product/RSB2A080B7https://www.schneider-electric.com/en/product/RSB2A080E7https://www.schneider-electric.com/en/product/RSB2A080F7https://www.schneider-electric.com/en/product/RSB2A080M7https://www.schneider-electric.com/en/product/RSB2A080P7https://www.schneider-electric.com/en/product/RSB2A080U7https://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RZM041BN7https://www.schneider-electric.com/en/product/RZM041FU7https://www.schneider-electric.com/en/product/RZM031FPDhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM031BNhttps://www.schneider-electric.com/en/product/RZM021RBhttps://www.schneider-electric.com/en/product/RZM021BNhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RSZE05Phttps://www.schneider-electric.com/en/product/RSZE08Phttps://www.schneider-electric.com/en/product/RZM040Whttps://www.schneider-electric.com/en/product/RSB1A120RDhttps://www.schneider-electric.com/en/product/RSB1A160RDhttps://www.schneider-electric.com/en/product/RSB1A120JDhttps://www.schneider-electric.com/en/product/RSB1A160JDhttps://www.schneider-electric.com/en/product/RSB1A120BDhttps://www.schneider-electric.com/en/product/RSB1A160BDhttps://www.schneider-electric.com/en/product/RSB1A120EDhttps://www.schneider-electric.com/en/product/RSB1A160EDhttps://www.schneider-electric.com/en/product/RSB1A120NDhttps://www.schneider-electric.com/en/product/RSB1A160NDhttps://www.schneider-electric.com/en/product/RSB1A120FDhttps://www.schneider-electric.com/en/product/RSB1A160FDhttps://www.schneider-electric.com/en/product/RSB1A120B7https://www.schneider-electric.com/en/product/RSB1A160B7https://www.schneider-electric.com/en/product/RSB1A120E7https://www.schneider-electric.com/en/product/RSB1A160E7https://www.schneider-electric.com/en/product/RSB1A120F7https://www.schneider-electric.com/en/product/RSB1A160F7https://www.schneider-electric.com/en/product/RSB1A120M7https://www.schneider-electric.com/en/product/RSB1A160M7https://www.schneider-electric.com/en/product/RSB1A120P7https://www.schneider-electric.com/en/product/RSB1A160P7https://www.schneider-electric.com/en/product/RSB1A120U7https://www.schneider-electric.com/en/product/RSB1A160U7https://www.schneider-electric.com/en/product/RSB1A120JDhttps://www.schneider-electric.com/en/product/RSB1A160JDhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RSZE08Phttps://www.schneider-electric.com/en/product/RSZE05P
2/7
AccessoriesDescription For
use withSold in lots of
Unit reference
Weightkg/lb
Plastic maintaining clamp All sockets 10 RSZR215 0.002/0 .004
Legend All sockets 10 RSZL300 0.001/0 .002
Bus jumper(10 x 8-pole jumper)
For inputs (A1, A2)of RSZE screw sockets (RSZE1S35M, RSZE1S48M)
10 RGZS08 0.006/0 .013
Bus jumper(10 x 2-pole jumper)
For input (A2) of RSZE push-in sockets (RSZE05P, RSZE08P)
10 RSZS02 0.002/0.004
RSZR215
RGZS08
XBK
_CP1
9466
RS_
532_
CPS
CT1
7003
-68-
Q
Zelio Electromechanical RelaysPlug-in relaysRSB interface relays
References (continued)
RSZS02
XBK_
CP1
9318
1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RGZS08https://www.schneider-electric.com/en/product/RSZS02https://www.schneider-electric.com/en/product/RSZE1S35Mhttps://www.schneider-electric.com/en/product/RSZE1S48Mhttps://www.schneider-electric.com/en/product/RSZE05Phttps://www.schneider-electric.com/en/product/RSZE08Phttps://www.schneider-electric.com/en/product/RSZR215https://www.schneider-electric.com/en/product/RGZS08https://www.schneider-electric.com/en/product/RSZS02
2/8
Presentation of the rangeRXG relays are interface plug-in relays with Faston pins for better reliability and robust installation. They are used in PLC applications.
The RXG interface relay range comprises: 1 10 A relays with 1 CO contact and 5 A relays with 2 CO contacts2 Sockets with separate contact terminals, built-in plastic maintaining clamp3 Protection modules (diode, diode + LED, RC circuit, or varistor + LED) common to
all RXG sockets4 Clip-in legends for all RXG sockets
These relays are available in both pre-assembled (single reference) and customer assembled offers.
Relay description1 Spring-return pushbutton for testing the contacts (green: c, red: a) 2 Mechanical “relay status” indicator3 Removable lock-down door enabling forced maintaining of the contacts for test
sequences or maintenance purposes 4 LED (depending on version) indicating the relay status5 Removable legend for relay identification6 5 or 8 Faston type pins7 Standard cover-type relay with pushbutton, mechanical indicator, and LED
options8 Clear cover-type relay
Socket descriptionSockets with separate contact terminals (1)
1 a Connection by connector b Connection by push-in terminal2 5 or 8 female contacts for the relay pins3 Hole for panel mounting4 Location for protection modules5 Built-in plastic maintaining clamp for locking components6 Locating slot for mounting on DIN rail7 Test point8 Push button to release wire9 Location for bus jumpers
(1) The inputs and outputs are separate from the relay supply .
Zelio Electromechanical RelaysPlug-in relaysRXG interface relays
Presentation
4
1
2
3
1
27 3 4
5
8
6
8
4
1b
9
7
Relay supply
Inputs
1a
2
2
3
5
5
6
6
4
Inputs
Outputs
Outputs
Relay supply
1
2
3
4
5
6
7
8
9
10
2/9
Zelio Electromechanical RelaysPlug-in relaysRXG interface relays
References
Pre-assembled interface relaysRelays with lockable test button and LED, mounted on sockets with protection module and integrated clampControl circuit voltageV
Sold in lots of
Number and type of contacts - Thermal current (Ith)
1 CO - 10 A 2 CO - 5 AUnit reference Weight
kg/lbUnit reference Weight
kg/lb24 c 30 RXG12BDPV
(RXG12BD + RGZE1S35M + RZM031RB)
0.059/0 .130 RXG22BDPV(RXG22BD + RGZE1S48M + RZM031RB)
0.066/0 .145
24 a 30 RXG12B7PV(RXG12B7 + RGZE1S35M + RZM021RB)
0.059/0 .130 RXG22B7PV(RXG22B7 + RGZE1S48M + RZM021RB)
0.067/0 .148
230 a 30 RXG12P7PV(RXG12P7 + RGZE1S35M + RZM021FP)
0.059/0 .130 RXG22P7PV(RXG22P7 + RGZE1S48M + RZM021FP)
0.067/0 .148
Relays with LED, mounted on sockets with protection module, and integrated clamp and LED24 c 30 RXG13BDPV
(RXG13BD + RGZE1S35M + RZM031RB)
0.058/0 .129 RXG23BDPV(RXG23BD + RGZE1S48M + RZM031RB)
0.066/0 .145
230 a 30 RXG13P7PV(RXG13P7 + RGZE1S35M + RZM021FP)
0.059/0 .130 RXG23P7PV(RXG23P7 + RGZE1S48M + RZM021FP)
0.067/0 .148
Relays with lockable test button and without LED, mounted on sockets with protection module, and integrated clamp and LED
24 c 30 RXG21BDPV(RXG21BD + RGZE1S48M + RZM031RB)
0.067/0 .148
24 a 30 RXG21B7PV(RXG21B7 + RGZE1S48M + RZM021RB)
0.067/0 .148
230 a 30 RXG21P7PV(RXG21P7 + RGZE1S48M + RZM021FP)
0.067/0 .148
Interface relays for customer assemblyStandard cover relays with lockable test button
6 c 10 RXG11RD RXG21RD 0.020/0 .044
12 c 10 RXG11JD RXG21JD 0.020/0 .044
24 c 10 RXG11BD RXG21BD 0.020/0 .044
48 c 10 RXG11ED RXG21ED 0.020/0 .044
60 c 10 RXG11ND RXG21ND 0.020/0 .044
110 c 10 RXG11FD RXG21FD 0.020/0 .044
24 a 10 RXG11B7 RXG21B7 0.020/0 .044
48 a 10 RXG11E7 RXG21E7 0.020/0 .044
120 a 10 RXG11F7 RXG21F7 0.020/0 .044
220 a 10 RXG11M7 RXG21M7 0.020/0 .044
230 a 10 RXG11P7 RXG21P7 0.020/0 .044
PF13
2501
RXG11RD
RS_
532_
CPM
FS18
068C
RXG22BDPV
1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RXG22BDPVhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RXG22B7PVhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RXG22P7PVhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RXG23BDPVhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RXG23P7PVhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RXG21BDPVhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RXG21B7PVhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RXG21P7PVhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM021RBhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM021RBhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RXG22BDhttps://www.schneider-electric.com/en/product/RXG22B7https://www.schneider-electric.com/en/product/RXG22P7https://www.schneider-electric.com/en/product/RXG23BDhttps://www.schneider-electric.com/en/product/RXG23P7https://www.schneider-electric.com/en/product/RXG21BDhttps://www.schneider-electric.com/en/product/RXG21B7https://www.schneider-electric.com/en/product/RXG21P7https://www.schneider-electric.com/en/product/RXG21RDhttps://www.schneider-electric.com/en/product/RXG21JDhttps://www.schneider-electric.com/en/product/RXG21BDhttps://www.schneider-electric.com/en/product/RXG21EDhttps://www.schneider-electric.com/en/product/RXG21NDhttps://www.schneider-electric.com/en/product/RXG21FDhttps://www.schneider-electric.com/en/product/RXG21B7https://www.schneider-electric.com/en/product/RXG21E7https://www.schneider-electric.com/en/product/RXG21F7https://www.schneider-electric.com/en/product/RXG21M7https://www.schneider-electric.com/en/product/RXG21P7https://www.schneider-electric.com/en/product/RGZE1S35Mhttps://www.schneider-electric.com/en/product/RXG12B7PVhttps://www.schneider-electric.com/en/product/RGZE1S35Mhttps://www.schneider-electric.com/en/product/RXG12P7PVhttps://www.schneider-electric.com/en/product/RGZE1S35Mhttps://www.schneider-electric.com/en/product/RXG13BDPVhttps://www.schneider-electric.com/en/product/RGZE1S35Mhttps://www.schneider-electric.com/en/product/RXG13P7PVhttps://www.schneider-electric.com/en/product/RGZE1S35Mhttps://www.schneider-electric.com/en/product/RXG22BDPVhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM021RBhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RXG12BDhttps://www.schneider-electric.com/en/product/RXG12B7https://www.schneider-electric.com/en/product/RXG12P7https://www.schneider-electric.com/en/product/RXG13BDhttps://www.schneider-electric.com/en/product/RXG13P7https://www.schneider-electric.com/en/product/RXG11RDhttps://www.schneider-electric.com/en/product/RXG11JDhttps://www.schneider-electric.com/en/product/RXG11BDhttps://www.schneider-electric.com/en/product/RXG11EDhttps://www.schneider-electric.com/en/product/RXG11NDhttps://www.schneider-electric.com/en/product/RXG11FDhttps://www.schneider-electric.com/en/product/RXG11B7https://www.schneider-electric.com/en/product/RXG11E7https://www.schneider-electric.com/en/product/RXG11F7https://www.schneider-electric.com/en/product/RXG11M7https://www.schneider-electric.com/en/product/RXG11P7https://www.schneider-electric.com/en/product/RXG11RD
2/10
Zelio Electromechanical RelaysPlug-in relaysRXG interface relays
References (continued)
Interface relays for customer assemblyStandard cover relays with lockable test button and LEDControl circuit voltageV
Sold in lots of
Number and type of contacts - Thermal current (Ith)
1 CO - 10 A 2 CO - 5 AUnit reference Unit reference Weight
kg/lb6 c 10 RXG12RD RXG22RD 0.020/0 .044
12 c 10 RXG12JD RXG22JD 0.020/0 .044
24 c 10 RXG12BD RXG22BD 0.020/0 .044
48 c 10 RXG12ED RXG22ED 0.020/0 .044
60 c 10 RXG12ND RXG22ND 0.020/0 .044
110 c 10 RXG12FD RXG22FD 0.020/0 .044
24 a 10 RXG12B7 RXG22B7 0.020/0 .044
48 a 10 RXG12E7 RXG22E7 0.020/0 .044
120 a 10 RXG12F7 RXG22F7 0.020/0 .044
220 a 10 RXG12M7 RXG22M7 0.020/0 .044
230 a 10 RXG12P7 RXG22P7 0.020/0 .044
Standard cover relays with LED6 c 10 RXG13RD RXG23RD 0.020/0 .044
12 c 10 RXG13JD RXG23JD 0.020/0 .044
24 c 10 RXG13BD RXG23BD 0.020/0 .044
48 c 10 RXG13ED RXG23ED 0.020/0 .044
60 c 10 RXG13ND RXG23ND 0.020/0 .044
110 c 10 RXG13FD RXG23FD 0.020/0 .044
24 a 10 RXG13B7 RXG23B7 0.020/0 .044
48 a 10 RXG13E7 RXG23E7 0.020/0 .044
120 a 10 RXG13F7 RXG23F7 0.020/0 .044
220 a 10 RXG13M7 RXG23M7 0.020/0 .044
230 a 10 RXG13P7 RXG23P7 0.020/0 .044
Clear cover relays6 c 10 RXG15RD RXG25RD 0.019/0 .042
12 c 10 RXG15JD RXG25JD 0.019/0 .042
24 c 10 RXG15BD RXG25BD 0.019/0 .042
48 c 10 RXG15ED RXG25ED 0.019/0 .042
60 c 10 RXG15ND RXG25ND 0.019/0 .042
110 c 10 RXG15FD RXG25FD 0.019/0 .042
24 a 10 RXG15B7 RXG25B7 0.018/0 .040
48 a 10 RXG15E7 RXG25E7 0.018/0 .040
120 a 10 RXG15F7 RXG25F7 0.018/0 .040
220 a 10 RXG15M7 RXG25M7 0.018/0 .040
230 a 10 RXG15P7 RXG25P7 0.018/0 .040
PF13
2505
RXG13RD
PF13
2507
RXG15RD
PF13
2510
RXG22B7
1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RXG22RDhttps://www.schneider-electric.com/en/product/RXG22JDhttps://www.schneider-electric.com/en/product/RXG22BDhttps://www.schneider-electric.com/en/product/RXG22EDhttps://www.schneider-electric.com/en/product/RXG22NDhttps://www.schneider-electric.com/en/product/RXG22FDhttps://www.schneider-electric.com/en/product/RXG22B7https://www.schneider-electric.com/en/product/RXG22E7https://www.schneider-electric.com/en/product/RXG22F7https://www.schneider-electric.com/en/product/RXG22M7https://www.schneider-electric.com/en/product/RXG22P7https://www.schneider-electric.com/en/product/RXG23RDhttps://www.schneider-electric.com/en/product/RXG23JDhttps://www.schneider-electric.com/en/product/RXG23BDhttps://www.schneider-electric.com/en/product/RXG23EDhttps://www.schneider-electric.com/en/product/RXG23NDhttps://www.schneider-electric.com/en/product/RXG23FDhttps://www.schneider-electric.com/en/product/RXG23B7https://www.schneider-electric.com/en/product/RXG23E7https://www.schneider-electric.com/en/product/RXG23F7https://www.schneider-electric.com/en/product/RXG23M7https://www.schneider-electric.com/en/product/RXG23P7https://www.schneider-electric.com/en/product/RXG25RDhttps://www.schneider-electric.com/en/product/RXG25JDhttps://www.schneider-electric.com/en/product/RXG25BDhttps://www.schneider-electric.com/en/product/RXG25EDhttps://www.schneider-electric.com/en/product/RXG25NDhttps://www.schneider-electric.com/en/product/RXG25FDhttps://www.schneider-electric.com/en/product/RXG25B7https://www.schneider-electric.com/en/product/RXG25E7https://www.schneider-electric.com/en/product/RXG25F7https://www.schneider-electric.com/en/product/RXG25M7https://www.schneider-electric.com/en/product/RXG25P7https://www.schneider-electric.com/en/product/RXG12RDhttps://www.schneider-electric.com/en/product/RXG12JDhttps://www.schneider-electric.com/en/product/RXG12BDhttps://www.schneider-electric.com/en/product/RXG12EDhttps://www.schneider-electric.com/en/product/RXG12NDhttps://www.schneider-electric.com/en/product/RXG12FDhttps://www.schneider-electric.com/en/product/RXG12B7https://www.schneider-electric.com/en/product/RXG12E7https://www.schneider-electric.com/en/product/RXG12F7https://www.schneider-electric.com/en/product/RXG12M7https://www.schneider-electric.com/en/product/RXG12P7https://www.schneider-electric.com/en/product/RXG13RDhttps://www.schneider-electric.com/en/product/RXG13JDhttps://www.schneider-electric.com/en/product/RXG13BDhttps://www.schneider-electric.com/en/product/RXG13EDhttps://www.schneider-electric.com/en/product/RXG13NDhttps://www.schneider-electric.com/en/product/RXG13FDhttps://www.schneider-electric.com/en/product/RXG13B7https://www.schneider-electric.com/en/product/RXG13E7https://www.schneider-electric.com/en/product/RXG13F7https://www.schneider-electric.com/en/product/RXG13M7https://www.schneider-electric.com/en/product/RXG13P7https://www.schneider-electric.com/en/product/RXG15RDhttps://www.schneider-electric.com/en/product/RXG15JDhttps://www.schneider-electric.com/en/product/RXG15BDhttps://www.schneider-electric.com/en/product/RXG15EDhttps://www.schneider-electric.com/en/product/RXG15NDhttps://www.schneider-electric.com/en/product/RXG15FDhttps://www.schneider-electric.com/en/product/RXG15B7https://www.schneider-electric.com/en/product/RXG15E7https://www.schneider-electric.com/en/product/RXG15F7https://www.schneider-electric.com/en/product/RXG15M7https://www.schneider-electric.com/en/product/RXG15P7https://www.schneider-electric.com/en/product/RXG13RDhttps://www.schneider-electric.com/en/product/RXG15RDhttps://www.schneider-electric.com/en/product/RXG22B7
2/11
Sockets with separate contact terminals arrangement, screw connector connection, and built-in clampDescription Thermal
current (Ith)Relay type Sold in
lots ofUnit reference
Weightkg/lb
1 CO socket with 1 pole 10 A RXG1ppp 10 RGZE1S35M 0.034/0 .075
2 CO socket with 2 poles 5 A RXG2ppp 10 RGZE1S48M 0.042/0 .093
Sockets with separate contact terminal arrangement, push-in terminals, and built-in clampDescription Thermal
current (Ith)Relay type Sold in
lots ofUnit reference
Weightkg/lb
1 CO socket with 1 pole 10 A RXG1ppp 10 RGZE05P 0.039/0 .086
2 CO socket with 2 poles 5 A RXG2ppp 10 RGZE08P 0.042/0 .093
Protection modulesDescription For
use withVoltageV
Sold in lots of
Unit reference
Weightkg/lb
Diode All sockets c 6…230 10 RZM040W 0.003/0 .007
RC circuit All sockets a 24…60 10 RZM041BN7 0.010/0 .022
a 110…240 10 RZM041FU7 0.010/0 .022
Diode + green LED All sockets c 6…24 10 RZM031RB 0.004/0 .009
c 24…60 10 RZM031BN 0.004/0 .009
c 110…230 10 RZM031FPD 0.004/0 .009
Varistor + green LED All sockets c or a 6…24 10 RZM021RB 0.005/0 .011
c or a 24…60 10 RZM021BN 0.005/0 .011
c or a 110…230 10 RZM021FP 0.005/0 .011
AccessoriesDescription For
use withSold in lots of
Unit reference
Weightkg/lb
Plastic maintaining clamp All sockets 10 RGZR215 0.002/0 .004
Legend All sockets 10 RSZL300 0.001/0 .002
Legend All relays 10 RGZL520 0.001/0 .002
Bus jumper (10 x 8-pole jumper)
For inputs (A1, A2)of RGZE screw sockets(RGZE1S35M, RGZE1S48M)
10 RGZS08 0.006/0 .013
Bus jumper (10 x 2-pole jumper)
For input (A2) of RGZE push-in sockets (RGZE05P, RGZE08P)
10 RSZS02 0.002/0 .004
Note: Starting from 2020, Zelio Relays range name will change to Harmony Relays. As the timeline for each range is different, there will be both Zelio and Harmony range during the transition period .
Zelio Electromechanical RelaysPlug-in relaysRXG interface relays
References (continued)PF
1325
17
RGZE1S48M
PF13
2522
RZM031RB
PF13
2519
RSZL300
PF13
2518
XBK_
CP1
9318
A
RGZR215
RSZS02
RS_
532_
CPS
CT1
7003
RGZS08
XBK_
CP1
9316
B
RGZE05P
1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RGZE1S35Mhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RZM041BN7https://www.schneider-electric.com/en/product/RZM041FU7https://www.schneider-electric.com/en/product/RZM031FPDhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RZM031BNhttps://www.schneider-electric.com/en/product/RZM021RBhttps://www.schneider-electric.com/en/product/RZM021BNhttps://www.schneider-electric.com/en/product/RZM021FPhttps://www.schneider-electric.com/en/product/RGZE05Phttps://www.schneider-electric.com/en/product/RGZE08Phttps://www.schneider-electric.com/en/product/RZM040Whttps://www.schneider-electric.com/en/product/RGZR215https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RGZL520https://www.schneider-electric.com/en/product/RGZS08https://www.schneider-electric.com/en/product/RSZS02https://www.schneider-electric.com/en/product/RGZE1S35Mhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RGZE1S48Mhttps://www.schneider-electric.com/en/product/RZM031RBhttps://www.schneider-electric.com/en/product/RGZE05Phttps://www.schneider-electric.com/en/product/RGZE08Phttps://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RGZR215https://www.schneider-electric.com/en/product/RGZE05Phttps://www.schneider-electric.com/en/product/RSZS02https://www.schneider-electric.com/en/product/RGZS08
2/12
Zelio Electromechanical RelaysPlug-in relaysRXM miniature relays
Presentation
Presentation of the rangeThe RXM miniature relay range comprises: 1 12 A relays with 2 CO contacts, 10 A relays with 3 CO contacts, 6 A relays with
4 CO contacts, and 3 A “low level” relays with 4 CO contacts (all these relays have the same dimensions)
2 Sockets with mixed or separate contact terminals3 Protection modules (diode, RC circuit, or varistor) common to all sockets4 Metal maintaining clamp for all sockets5 Plastic maintaining clamp for all sockets6 2-pole bus jumper that can be used on sockets with separate contact terminals in
order to simplify cabling when creating an equipotential link between the coil terminals
7 Clip-in legends for all sockets except RXZE2M114 and RXZE2S114S
These relays are available in both pre-assembled (single reference) and customer assembled offers.
Relay description 1 Spring-return pushbutton for testing the contacts (green: c, red: a) 2 Mechanical “relay status” indicator3 Removable lock-down door enabling forced maintaining of the contacts for test
sequences or maintenance purposes 4 LED (depending on version) indicating the relay status5 Removable legend for relay identification6 4 notches for rail mounting adapter or panel mounting adapter with mounting lugs7 8, 11, or 14 Faston type pins8 Area by which the product can be easily gripped9 Mounting adapter enabling direct mounting of the relay on a panel10 Mounting adapter enabling direct mounting of the relay on a DIN rail
12
7
3
4
56
8
7
2
1
4
5
3
or6
9
9
10
1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RXZE2S114Shttps://www.schneider-electric.com/en/product/RXZE2M114
2/13
Zelio Electromechanical RelaysPlug-in relaysRXM miniature relays
Presentation (continued)
Socket description Sockets with mixed contact terminals (1)
1 Connection by screw clamp terminals or screw connector2 14 female contacts for the relay pins3 Location for protection modules4 Locking components for plastic and metal maintaining clamps5 Locating slot for mounting on DIN rail with compression spring or mounting clip6 2 or 4 holes for panel mounting
Sockets with separate contact terminals (2)1 a Connection by connector b Connection by push in terminal2 8, 11, or 14 female contacts for the relay pins3 a Locking components for plastic and metal maintaining clamps b Built-in plastic maintaining clamp for locking components4 Location for protection modules5 Locating slot for mounting on DIN rail with compression spring or mounting clip6 2 holes for panel mounting7 Test point8 Push button to release wire9 Location for bus jumpers
(1) The inputs are mixed with the relay supply, with the outputs being located on the opposite side of the socket .
(2) The inputs and outputs are separate from the relay supply .
Sockets with mixed contact terminals
1bInputs
2
5
9
Outputs
Relay supply
87
43b
Sockets with separate contact terminals
Sockets with separate contact terminals
1a5
2
43a
6 9
Outputs
Inputs
Relay supply
1
2
3
4
5
Outputs
Inputs
Relay supply
6
1
2
3
4
5
6
7
8
9
10
2/14
Zelio Electromechanical RelaysPlug-in relaysRXM miniature relays
References
Pre-assembled interface relays Relays without LED, mounted on sockets with clamp and socket legend (sold in lots of 30)ControlcircuitvoltageV
Type of socket
Number and type of contacts - Thermal current (Ith)
2 CO - 12 A 4 CO - 6 AUnit reference Weight
kg/lbUnit reference Weight
kg/lb
24 c Mixed terminal socket
– – RXM4AB1BDPVM(RXM4AB1BD + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
24 a – – RXM4AB1B7PVM(RXM4AB1B7 + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
230 a – – RXM4AB1P7PVM(RXM4AB1P7 + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
24 c Separate terminal socket
– – RXM4AB1BDPVS(RXM4AB1BD + RXZE2S114M + RXZR335 + RXZL520)
0.113/ 0 .249
24 a – – RXM4AB1B7PVS(RXM4AB1B7 + RXZE2S114M + RXZR335 + RXZL520)
0.113/ 0 .249
230 a – – RXM4AB1P7PVS(RXM4AB1P7 + RXZE2S114M + RXZR335 + RXZL520)
0.113/ 0 .249
Relays with LED, mounted on sockets with clamp and socket legend (sold in lots of 30)24 c Mixed
terminal socket
RXM2AB2BDPVM(RXM2AB2BD + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
RXM4AB2BDPVM(RXM4AB2BD + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
24 a RXM2AB2B7PVM(RXM2AB2B7 + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
RXM4AB2B7PVM(RXM4AB2B7 + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
230 a RXM2AB2P7PVM(RXM2AB2P7 + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
RXM4AB2P7PVM(RXM4AB2P7 + RXZE2M114M + RXZR335 + RXZL520)
0.099/ 0 .218
24 c Separate terminal socket
RXM2AB2BDPVS(RXM2AB2BD + RXZE2S108M + RXZR335 + RXZL520)
0.101/ 0 .223
RXM4AB2BDPVS(RXM4AB2BD + RXZE2S114M + RXZR335 + RXZL520)
0.113/ 0 .249
24 a RXM2AB2B7PVS(RXM2AB2B7 + RXZE2S108M + RXZR335 + RXZL520)
0.101/ 0 .223
RXM4AB2B7PVS(RXM4AB2B7 + RXZE2S114M + RXZR335 + RXZL520)
0.113/ 0 .249
230 a RXM2AB2P7PVS(RXM2AB2P7 + RXZE2S108M + RXZR335 + RXZL520)
0.101/ 0 .223
RXM4AB2P7PVS(RXM4AB2P7 + RXZE2S114M + RXZR335 + RXZL520)
0.113/ 0 .249
RS_
532_
CPM
FS18
079C
RXM4AB1BDPVS
1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RXM4AB1BDPVMhttps://www.schneider-electric.com/en/product/RXM4AB1B7PVMhttps://www.schneider-electric.com/en/product/RXM4AB1P7PVMhttps://www.schneider-electric.com/en/product/RXM4AB1BDPVShttps://www.schneider-electric.com/en/product/RXM4AB1B7PVShttps://www.schneider-electric.com/en/product/RXM4AB1P7PVShttps://www.schneider-electric.com/en/product/RXM4AB2BDPVMhttps://www.schneider-electric.com/en/product/RXM4AB2B7PVMhttps://www.schneider-electric.com/en/product/RXM4AB2P7PVMhttps://www.schneider-electric.com/en/product/RXM4AB2BDPVShttps://www.schneider-electric.com/en/product/RXM4AB2B7PVShttps://www.schneider-electric.com/en/product/RXM4AB2P7PVShttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2S114Mhttps://www.schneider-electric.com/en/product/RXZE2S114Mhttps://www.schneider-electric.com/en/product/RXZE2S114Mhttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2S114Mhttps://www.schneider-electric.com/en/product/RXZE2S114Mhttps://www.schneider-electric.com/en/product/RXZE2S114Mhttps://www.schneider-electric.com/en/product/RXM4AB1BDhttps://www.schneider-electric.com/en/product/RXM4AB1B7https://www.schneider-electric.com/en/product/RXM4AB1P7https://www.schneider-electric.com/en/product/RXM4AB1BDhttps://www.schneider-electric.com/en/product/RXM4AB1B7https://www.schneider-electric.com/en/product/RXM4AB1P7https://www.schneider-electric.com/en/product/RXM4AB2BDhttps://www.schneider-electric.com/en/product/RXM4AB2B7https://www.schneider-electric.com/en/product/RXM4AB2P7https://www.schneider-electric.com/en/product/RXM4AB2BDhttps://www.schneider-electric.com/en/product/RXM4AB2B7https://www.schneider-electric.com/en/product/RXM4AB2P7https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXM2AB2BDPVMhttps://www.schneider-electric.com/en/product/RXM2AB2B7PVMhttps://www.schneider-electric.com/en/product/RXM2AB2P7PVMhttps://www.schneider-electric.com/en/product/RXM2AB2BDPVShttps://www.schneider-electric.com/en/product/RXM2AB2B7PVShttps://www.schneider-electric.com/en/product/RXM2AB2P7PVShttps://www.schneider-electric.com/en/product/RXM4AB1BDPVShttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2S108Mhttps://www.schneider-electric.com/en/product/RXZE2S108Mhttps://www.schneider-electric.com/en/product/RXZE2S108Mhttps://www.schneider-electric.com/en/product/RXM2AB2BDhttps://www.schneider-electric.com/en/product/RXM2AB2B7https://www.schneider-electric.com/en/product/RXM2AB2P7https://www.schneider-electric.com/en/product/RXM2AB2BDhttps://www.schneider-electric.com/en/product/RXM2AB2B7https://www.schneider-electric.com/en/product/RXM2AB2P7https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZL520
2/15
Zelio Electromechanical RelaysPlug-in relaysRXM miniature relays
References (continued)
Miniature relays for customer assemblyRXM miniature relays without LED (sold in lots of 10) Control circuit voltageV
Number and type of contacts - Thermal current (Ith)2 CO - 12 A 3 CO - 10 A 4 CO - 6 AUnit reference
Weightkg/lb
Unit reference
Weightkg/lb
Unit reference
Weightkg/lb
c 12 RXM2AB1JD 0.037/0 .082 RXM4AB1JD 0.037/0 .082c 24 RXM2AB1BD 0.037/0 .082 RXM4AB1BD 0.037/0 .082c 48 RXM2AB1ED 0.037/0 .082 RXM4AB1ED 0.037/0 .082c 110 RXM2AB1FD
0.037/0 .082 RXM3AB1JD 0.037/0 .082 RXM3AB1BD 0.037/0 .082 RXM3AB1ED 0.037/0 .082 RXM3AB1FD 0.037/0 .082 RXM4AB1FD 0.037/0 .082
c 220 – – – – RXM4AB1MD 0.037/0 .082a 24 RXM2AB1B7 0.037/0 .082 RXM4AB1B7 0.037/0 .082a 48 RXM2AB1E7 0.037/0 .082 RXM4AB1E7 0.037/0 .082a 120 RXM2AB1F7 0.037/0 .082 RXM4AB1F7 0.037/0 .082a 230 RXM2AB1P7
0.037/0 .082 RXM3AB1B7 0.037/0 .082 RXM3AB1E7 0.037/0 .082 RXM3AB1F7 0.037/0 .082 RXM3AB1P7 0.037/0 .082 RXM4AB1P7 0.037/0 .082
a 240 – – – – RXM4AB1U7 0.037/0 .082
RXM miniature relays with LED (sold in lots of 10)c 12 RXM2AB2JD 0.037/0 .082 RXM4AB2JD 0.037/0 .082c 24 RXM2AB2BD 0.037/0 .082 RXM4AB2BD 0.037/0 .082c 48 RXM2AB2ED 0.037/0 .082 RXM4AB2ED 0.037/0 .082c 110 RXM2AB2FD
0.037/0 .082 RXM3AB2JD 0.037/0 .082 RXM3AB2BD 0.037/0 .082 RXM3AB2ED 0.037/0 .082 RXM3AB2FD 0.037/0 .082 RXM4AB2FD 0.037/0 .082
c 125 – – – – RXM4AB2GD 0.037/0 .082a 24 RXM2AB2B7 0.037/0 .082 RXM4AB2B7 0.037/0 .082a 48 RXM2AB2E7 0.037/0 .082 RXM4AB2E7 0.037/0 .082a 120 RXM2AB2F7 0.037/0 .082 RXM4AB2F7 0.037/0 .082a 230 RXM2AB2P7
0.037/0 .082 RXM3AB2B7 0.037/0 .082 RXM3AB2E7 0.037/0 .082 RXM3AB2F7 0.037/0 .082 RXM3AB2P7 0.037/0 .082 RXM4AB2P7 0.037/0 .082
RXM miniature relays with low level contacts, without LED (sold in lots of 10) Control circuit voltageV
Number and type of contacts Thermal current (Ith)4 CO - 3 AUnit reference
Weightkg/lb
c 12 RXM4GB1JD 0.037/0 .082
c 24 RXM4GB1BD 0.037/0 .082
c 48 RXM4GB1ED 0.037/0 .082
c 110 RXM4GB1FD 0.037/0 .082
a 24 RXM4GB1B7 0.037/0 .082
a 48 RXM4GB1E7 0.037/0 .082
a 120 RXM4GB1F7 0.037/0 .082
a 230 RXM4GB1P7 0.037/0 .082
RXM miniature relays with low level contacts, with LED (sold in lots of 10) c 12 RXM4GB2JD 0.037/0 .082
c 24 RXM4GB2BD 0.037/0 .082
c 48 RXM4GB2ED 0.037/0 .082
c 60 RXM4GB2ND 0.037/0 .082
c 110 RXM4GB2FD 0.037/0 .082
c 125 RXM4GB2GD 0.037/0 .082
c 220 RXM4GB2MD 0.037/0 .082
a 24 RXM4GB2B7 0.037/0 .082
a 48 RXM4GB2E7 0.037/0 .082
a 120 RXM4GB2F7 0.037/0 .082
a 230 RXM4GB2P7 0.037/0 .082
a 240 RXM4GB2U7 0.037/0 .082
RXM4GB1BD
PF15
3502
A
RXM4GB1P7
PF15
3500
A
RXM4GB2BD
PF15
3504
APF
1535
06A
RXM4GB2F7
RXM2AB1F7
PF10
6011
RXM2AB1BD
PF15
3500
PF15
3506
RXM2AB2F7
RXM2AB2ED
PF15
3504
1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RXM4AB1JDhttps://www.schneider-electric.com/en/product/RXM4AB1BDhttps://www.schneider-electric.com/en/product/RXM4AB1EDhttps://www.schneider-electric.com/en/product/RXM4AB1FDhttps://www.schneider-electric.com/en/product/RXM4AB1MDhttps://www.schneider-electric.com/en/product/RXM4AB1B7https://www.schneider-electric.com/en/product/RXM4AB1E7https://www.schneider-electric.com/en/product/RXM4AB1F7https://www.schneider-electric.com/en/product/RXM4AB1P7https://www.schneider-electric.com/en/product/RXM4AB1U7https://www.schneider-electric.com/en/product/RXM4AB2JDhttps://www.schneider-electric.com/en/product/RXM4AB2BDhttps://www.schneider-electric.com/en/product/RXM4AB2EDhttps://www.schneider-electric.com/en/product/RXM4AB2FDhttps://www.schneider-electric.com/en/product/RXM4AB2GDhttps://www.schneider-electric.com/en/product/RXM4AB2B7https://www.schneider-electric.com/en/product/RXM4AB2E7https://www.schneider-electric.com/en/product/RXM4AB2F7https://www.schneider-electric.com/en/product/RXM4AB2P7https://www.schneider-electric.com/en/product/RXM4GB1JDhttps://www.schneider-electric.com/en/product/RXM4GB1BDhttps://www.schneider-electric.com/en/product/RXM4GB1EDhttps://www.schneider-electric.com/en/product/RXM4GB1FDhttps://www.schneider-electric.com/en/product/RXM4GB1B7https://www.schneider-electric.com/en/product/RXM4GB1E7https://www.schneider-electric.com/en/product/RXM4GB1F7https://www.schneider-electric.com/en/product/RXM4GB1P7https://www.schneider-electric.com/en/product/RXM4GB2JDhttps://www.schneider-electric.com/en/product/RXM4GB2BDhttps://www.schneider-electric.com/en/product/RXM4GB2EDhttps://www.schneider-electric.com/en/product/RXM4GB2NDhttps://www.schneider-electric.com/en/product/RXM4GB2FDhttps://www.schneider-electric.com/en/product/RXM4GB2GDhttps://www.schneider-electric.com/en/product/RXM4GB2MDhttps://www.schneider-electric.com/en/product/RXM4GB2B7https://www.schneider-electric.com/en/product/RXM4GB2E7https://www.schneider-electric.com/en/product/RXM4GB2F7https://www.schneider-electric.com/en/product/RXM4GB2P7https://www.schneider-electric.com/en/product/RXM4GB2U7https://www.schneider-electric.com/en/product/RXM2AB1JDhttps://www.schneider-electric.com/en/product/RXM3AB1JDhttps://www.schneider-electric.com/en/product/RXM2AB1BDhttps://www.schneider-electric.com/en/product/RXM3AB1BDhttps://www.schneider-electric.com/en/product/RXM2AB1EDhttps://www.schneider-electric.com/en/product/RXM3AB1EDhttps://www.schneider-electric.com/en/product/RXM2AB1FDhttps://www.schneider-electric.com/en/product/RXM3AB1FDhttps://www.schneider-electric.com/en/product/RXM2AB1B7https://www.schneider-electric.com/en/product/RXM3AB1B7https://www.schneider-electric.com/en/product/RXM2AB1E7https://www.schneider-electric.com/en/product/RXM3AB1E7https://www.schneider-electric.com/en/product/RXM2AB1F7https://www.schneider-electric.com/en/product/RXM3AB1F7https://www.schneider-electric.com/en/product/RXM2AB1P7https://www.schneider-electric.com/en/product/RXM3AB1P7https://www.schneider-electric.com/en/product/RXM2AB2JDhttps://www.schneider-electric.com/en/product/RXM3AB2JDhttps://www.schneider-electric.com/en/product/RXM2AB2BDhttps://www.schneider-electric.com/en/product/RXM3AB2BDhttps://www.schneider-electric.com/en/product/RXM2AB2EDhttps://www.schneider-electric.com/en/product/RXM3AB2EDhttps://www.schneider-electric.com/en/product/RXM2AB2FDhttps://www.schneider-electric.com/en/product/RXM3AB2FDhttps://www.schneider-electric.com/en/product/RXM2AB2B7https://www.schneider-electric.com/en/product/RXM3AB2B7https://www.schneider-electric.com/en/product/RXM2AB2E7https://www.schneider-electric.com/en/product/RXM3AB2E7https://www.schneider-electric.com/en/product/RXM2AB2F7https://www.schneider-electric.com/en/product/RXM3AB2F7https://www.schneider-electric.com/en/product/RXM2AB2P7https://www.schneider-electric.com/en/product/RXM3AB2P7https://www.schneider-electric.com/en/product/RXM4GB1BDhttps://www.schneider-electric.com/en/product/RXM4GB1P7https://www.schneider-electric.com/en/product/RXM4GB2BDhttps://www.schneider-electric.com/en/product/RXM4GB2F7https://www.schneider-electric.com/en/product/RXM2AB1F7https://www.schneider-electric.com/en/product/RXM2AB1BDhttps://www.schneider-electric.com/en/product/RXM2AB2F7https://www.schneider-electric.com/en/product/RXM2AB2ED
2/16
References (continued) Zelio Electromechanical RelaysPlug-in relaysRXM miniature relays
RXM041pp7
PF10
6018
SocketsContact terminal arrangement
Connection Relay type Sold in lots of
Unit reference
Weightkg/lb
Mixed Screw clamp terminals RXM2ppppp (3)RXM4ppppp
10 RXZE2M114 (1) 0.048/0 .106
Screw connector RXM2ppppp (3)RXM4ppppp
10 RXZE2M114M (1) 0.056/0 .124
Separate Spring clamp terminals RXM2ppppp (3) RXM4ppppp
10 RXZE2S114S (2) 0.070/0 .154
Screw connector RXM2ppppp 10 RXZE2S108M (2) 0.058/0 .128
RXM3ppppp 10 RXZE2S111M (1) 0.066/0 .146
RXM4ppppp 10 RXZE2S114M (1) 0.070/0 .154
Separate Spring clamp push-in terminals
RXM2ppppp RXM4ppppp
10 RXZE14P 0.080/0 .176
Protection modulesDescription Voltage
VFor use with
Sold in lots of
Unit reference
Weightkg/lb
Diode c 6...250 All sockets 10 RXM040W 0.003/0 .007
RC circuit a 24...60 All sockets 10 RXM041BN7 0.010/0 .022
a 110...240 All sockets 10 RXM041FU7 0.010/0 .022
Varistor a/c 6...24 All sockets 10 RXM021RB 0.030/0 .066
a/c 24...60 All sockets 10 RXM021BN 0.030/0 .066
a/c 110...240 All sockets 10 RXM021FP 0.030/0 .066
Timing relaysDescription For
use withUnit reference
Weightkg/lb
2 or 4 timed CO contacts (function A) RXZEpppppp sockets REXL2pp (4) –
REXL4pp (4) –
(1) Thermal current (Ith): 10 A .(2) Thermal current (Ith): 12 A .(3) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current should not exceed 10 A .(4) Please refer to “Zelio Time timing relays” catalog .(5) Test button becomes inaccessible .Note: Starting from 2020, Zelio Relays range name will change to Harmony Relays. As the timeline for each range is different,
there will be both Zelio and Harmony range during the transition period .
RXZE2S108M + Relay RXM4AB1F7
PF15
3537
A1
2
3
4
5
6
7
8
9
10
https://www.schneider-electric.com/en/product/RXZE2M114Mhttps://www.schneider-electric.com/en/product/RXZE2S114Shttps://www.schneider-electric.com/en/product/RXZE2S108Mhttps://www.schneider-electric.com/en/product/RXZE2S111Mhttps://www.schneider-electric.com/en/product/RXZE2S114Mhttps://www.schneider-electric.com/en/product/RXZE2M114https://www.schneider-electric.com/en/product/RXM041BN7https://www.schneider-electric.com/en/product/RXM041FU7https://www.schneider-electric.com/en/product/RXM021RBhttps://www.schneider-electric.com/en/product/RXM021BNhttps://www.schneider-electric.com/en/product/RXM021FPhttps://www.schneider-electric.com/en/product/RXZE14Phttps://www.schneider-electric.com/en/product/RXM040Whttps://www.schneider-electric.com/en/product/RXZE2S108Mhttps://www.schneider-electric.com/en/product/RXM4AB1F7
2/17
References (continued) Zelio Electromechanical RelaysPlug-in relaysRXM miniature relays
RE_
529_
CPF
JR18
001B
RXZS2
PF15
3530
A
RXZE2DA
PF15
3531
RXZ400
PF15
3528
A
RXZL520
PF15
3533
A
RXZL300
XBK_
CP1
9322
0A
AccessoriesDescription For
use withSold in lots of
Unit reference
Weightkg/lb
Metal maintaining clamp All sockets 10 RXZ400 0.001/0.002
Plastic maintaining clamp All sockets except push-in socket RXZE14P
10 RXZR335 0.005/0.011
RXZE14P 10 RXZR315 0.004/0.009
2-pole bus jumper (Ith: 5 A) All screw sockets with separate contacts (RXZE2Spppp)
10 RXZS2 0.005/0.011
Bus jumper(10 x 2-pole jumper)
For input (A2) of RXZE push in sockets (RXZE14P)
10 RSZS02 0.002/0.004
Mounting adapter for 5 rails (5) All relays 10 RXZE2DA 0.004/0.009
Mounting adapter with panel mounting lugs All relays 10 RXZE2FA 0.002/0.004
Clip-in legends All relays (sheet of 108 legends)
10 RXZL520 0.080/0.176
RXZE14P 10 RXZL300 0.004/0.009
All sockets except RXZE2M114 and RXZE2S114S
10 RXZL420 0.001/0.002
RXZE2S114S socket 10 RSZL300 0.001/0.002
(1) Thermal current (Ith): 10 A.(2) Thermal current (Ith): 12 A.(3) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current should not exceed 10 A.(4) Please refer to “Zelio Time timing relays” catalog.(5) Test button becomes inaccessible.
REXL4pp
XBK_
CP1
9321
9A
RXZR315
XBK_
CP1
9318
A
RSZS02
https://www.schneider-electric.com/en/product/RXZR335https://www.schneider-electric.com/en/product/RXZR315https://www.schneider-electric.com/en/product/RXZE2DAhttps://www.schneider-electric.com/en/product/RXZE2FAhttps://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZL300https://www.schneider-electric.com/en/product/RXZL420https://www.schneider-electric.com/en/product/RSZL300https://www.schneider-electric.com/en/product/RSZS02https://www.schneider-electric.com/en/product/RXZS2https://www.schneider-electric.com/en/product/RXZE2S114Shttps://www.schneider-electric.com/en/product/RXZE2S114Shttps://www.schneider-electric.com/en/product/RXZE2M114https://www.schneider-electric.com/en/product/RXZE2DAhttps://www.schneider-electric.com/en/product/RXZL520https://www.schneider-electric.com/en/product/RXZL300https://www.schneider-electric.com/en/product/RXZE14Phttps://www.schneider-electric.com/en/product/RXZE14Phttps://www.schneider-electric.com/en/product/RXZE14Phttps://www.schneider-electric.com/en/product/RXZE14Phttps://www.schneider-electric.com/en/product/RXZR315https://www.schneider-electric.com/en/product/RXZ400https://www.schneider-electric.com/en/product/RSZS02https://www.schneider-electric.com/en/product/RXZS2https://www.schneider-electric.com/en/product/RXZ400
2/18
Presentation of the rangeThe RUM universal relay range comprises: 1 10 A relays with 2 and 3 CO contacts, and cylindrical or flat (Faston type) pins (all
these relays have the same dimensions)2 Sockets with mixed or separate contact terminals3 Protection modules (diode, RC circuit, or varistor) or 1 timer module, common to
all RUM sockets4 Metal maintaining clamp for all RUM sockets5 2-pole bus jumper that can be used on sockets with separate contact terminals in
order to simplify cabling when creating an equipotential link between the coil terminals
6 Clip-in legends for the sockets
Relay description1 Spring-return pushbutton for testing the contacts (green: c, red: a) 2 Mechanical “relay status” indicator3 Removable lock-down door enabling forced maintaining of the contacts for test
sequences or maintenance purposes (1)4 LED (depending on version) indicating the relay status5 Removable legend for relay identification6 Area by which the product can be easily gripped7 8 or 11 cylindrical pins 8 8 or 11 flat (Faston type) pins
Socket descriptionSockets with separate contact terminals (3)
1 Connection by screw connector 2 a 8 or 11 female contacts for the relay cylindrical pins
b 11 female contacts for the relay flat pins3 Location for protection modules or the timer module4 Locking component for metal maintaining clamp5 Locating slot for mounting on DIN rail with mounting clip6 2 holes for panel mounting7 Location for bus jumpers (see dimensions for mounting on sockets on
www.schneider-electric.com)
(1) During operation, this lock-down door must always be in the closed position .(2) The inputs are mixed with the relay supply, with the outputs being located on the opposite
side of the socket .(3) The inputs and outputs are separate from the relay supply .
Zelio Electromechanical RelaysPlug-in relaysRUM universal relays
Presentation
1234
5
6
1
2b
3
4
5 7
Inputs
Outputs
Relay supply5
6
5
2
1
3
4
16
2a3
4
5 7
Inputs
Relay supply5