DataSheet - Titan Power Plus SU-2

Post on 12-Mar-2015

97 views 14 download

Transcript of DataSheet - Titan Power Plus SU-2

© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.

PRODUCT DATA SHEETTitanPowerPlus SU-2 Flat Plate Collector

SunMaxx Solar, Inc.56 Broome Corporate PkwyConklin, NY 137481.877.786.62991.800.786.0329 faxwww.sunmaxxsolar.com

12-Year Warranty (when installed by a certified installer)SRCC CertifiedSolar Keymark Certified

SealingCasingLateral thermal insulationGlazingDouble-sided adhesive tapeAbsorber material (copper)Thermal insulationRear panel

1

2

3

4

5

6

7

8

Technical SpecificationsDimensions (in) 79.4 x 38.78 x 3.03

(201.6 x 98.5 x 7.7 cm)

Gross Collector Area (ft2) 21.42 (1.99 m2)

Net Aperture Area (ft2) 20.17 (1.874 m2)

Ratio Net/Gross Area 0.94

Dry Weight (lbs.) 74.96 (34 kg)

Fluid Capacity (gal.) 0.26 (1 L)

Minimum Flow Rate (gpm) 0.13 (30 L/hr)

Nominal Flow Rate (gpm) 0.44 (100 L/hr)

Maximum Flow Rate (gpm) 0.79 (180 L/hr)

Recommended Flow Rate (gpm) 0.176 - 0.167 (40 - 140 L/hr)

Max Number of Collectors in Series 10

Tilt Angle (deg) 35 - 90

Maximum Operating Pressure (psi) 87 (6 bars)

Recommended Operating Pressure (psi) 36.3 - 43.5 (2.5 - 3 bars)

Stagnation Temperature 383 °F (195 °C)

MaterialsStainless Steel, grade AISI: 304; 0.7 mm gauge

3.2 mm toughened glass

Mounting Optionsconstruction for sloping roof

integration into sloping roof

on flat roof with stand

facade

© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.

PRODUCT DATA SHEETTitanPowerPlus SU-2 Flat Plate Collector

SunMaxx Solar, Inc.56 Broome Corporate PkwyConklin, NY 137481.877.786.62991.800.786.0329 faxwww.sunmaxxsolar.com

PEAK POWER PER COLLECTOR UNIT (Wpeak)Peak Power (Wpeak) 1501 WThermal Capacity* 4.7 kJ/KFlow rate during test 160 l/hFluid for test Water-Glycol 33.3%

*Specific thermal capacity C of the collector without fluid, determined according to 6.1.6.2 of EN12975-2:2006

INCIDENT ANGLE MODIFIER (IAM)K1, transversal IAM at 50° 0.95

K2, longitudinal IAM at 50° 0.95

PRESSURE DROP (∆p) AT NOMINAL FLOW RATE∆p=1168 Pa (T=20°C)

RELATIVE EFFICIENCY (η)Reference Gross Aperture Absorberη0 0.754 0.801 0.805a1 [WK-1m-2] 3.43 3.64 3.66a2 [WK-2m-2] 0.0106 0.0112 0.0113