Cns studies with rodentPACK2 telemetry system

Post on 13-Nov-2014

191 views 4 download

Tags:

description

The rodentPACK2 transmits data via radiotelemetry, offering a well-tolerated, humane alternative to tethered EEG. Direct inputs from the device to cortical and deep brain regions provide a high signal-to-noise ratio, facilitating the detection of EEG events. The EEG analyzer module, within ecgAUTO software, allows scientist to easily: generate FFT power spectrums with user defined frequency bands detect epilepsy seizures differentiate between four sleep stages and calculate global sleep score.

Transcript of Cns studies with rodentPACK2 telemetry system

www.emka.frwww.emka.fr

cliquer pour ajouter un titreEpileptic seizure detection& sleep scoring

EEG telemetrysemi-invasive biopotential, temperature & activity in rodents

www.emka.fr

software for CNS studiesrodentPACK2 EEG telemetry

A

B

C

D

E

sources of EEG/EMG data

epilepsy seizure detection

sleep scoring

rodentPACK2 for EEG telemetry

using third party files and telemetry

www.emka.frwww.emka.fr

smart tools – swift services – sharp

research

www.emka.fr

sources of EEG/EMG data

A

www.emka.fr

emka SOFTWARE ACQUIRE & PROCESS DATA

• recorded by emka iox data acquisition software

• recorded from third party device with analog outputs

• converted from text file

• converted from third party acquisition software

• recorded directly from third party telemetry

www.emka.frwww.emka.fr

smart tools – swift services – sharp

research

www.emka.fr

epileptic seizure detection

B

www.emka.fr

EEG ANALYZER MODULEwithin ecgAUTO software

Automatic software seizure detection is peformed using combined analysis of various parameters

www.emka.fr

EPILEPSY SEIZURE DETECTIONwithin ecgAUTO software

• detection is based on a user defined multicriteria condition involving

1 to 4 parameters and associated thresholds

• among these parameters, some may be derived from FFT computations

• analysis is performed in successive epochs of adjustable length

and overlap percentage

www.emka.fr

EPILEPSY SEIZURE DETECTIONwithin ecgAUTO software

Example of detection settings:

• epochs of n seconds (typically 2 to 10)

• successive epochs overlap by x% (typically 0 to 50%)

• epoch is a candidate if its energy, or power within some frequency range (typically 3Hz to 10hz) exceeds a threshold

• seizure consists of a minimum number of consecutive candidate epochs (typically 2 to 3)

www.emka.fr

EPILEPSY SEIZURE DETECTIONwithin ecgAUTO software

Epochs of 4s, with 50% overlap. Single threshold on total epoch energy.Main data table shows epoch status and detected seizures

www.emka.fr

EPILEPSY SEIZURE DETECTION

www.emka.fr

plot with individual spectrums shown along input EEG trace

EPILEPSY SEIZURE DETECTION

www.emka.fr

EPILEPSY SEIZURE DETECTION

Detected seizures are visible:

• in main results table

• listed in a specific seizure table for review and edition

www.emka.fr

SEIZURE SUMMARY TABLE

Seizure table shows:

• index

• time in file

• duration

• limits on trace

• individual epochs

www.emka.fr

www.emka.fr

SEIZURE SUMMARY TABLE

Seizure table other key features:

• display seizures listed per time, or increasing/decreasing duration

• summary per time frame (number and total duration of all seizures in successive 15mn frames),

• status of criteria used to detect candidate epochs

www.emka.fr

EPILEPSY SEIZURE EDITION

• manual edition of seizures limits is possible

• invalid seizures can be deleted

• undetected seizures can be created

• valid seizures can be exported to text file

www.emka.fr

EPILEPSY SEIZURE EDITIONAutomatically detected limits (in green)

Manual cursor to modify limits (blue & red arrows)

www.emka.fr

EPILEPSY SEIZURE EDITIONManually added seizure shown in yellow on trace and in summary table

www.emka.fr

EPILEPSY SEIZURE INVALIDATIONInvalidated seizure in dotted red on trace, in pink in table

www.emka.fr

EPILEPSY SEIZURE EDITION TRACKING

All manual edition actions:

• shown in summary table and on data traces• are recorded in data file• can be reversed

www.emka.fr

EPILEPSY SEIZURE DATA EXPORT

Seizure text format table with date, time, seizure length

Full epoch per epoch table also available__________ __________ __________ epilepsy table report

cpu-date cpu-time site-time(hS01+)__EPL_epoch#(hS01+)__EPL_lengthS

january 7, 2009 15:49:13.000 00:01:21.991 17 65.59january 7, 2009 15:50:13.000 00:02:21.987 8 29.592january 7, 2009 15:53:09.000 00:05:17.991 41 157.599january 7, 2009 15:54:57.000 00:07:05.984 1 1.594january 7, 2009 15:57:37.000 00:09:45.974 5 17.593january 7, 2009 15:58:13.000 00:10:21.991 8 25.612january 7, 2009 15:59:01.000 00:11:09.988 10 37.591january 7, 2009 16:00:57.000 00:13:05.981 22 85.588january 7, 2009 16:03:13.000 00:15:21.992 32 121.605january 7, 2009 16:04:09.000 00:16:17.988 12 45.591january 7, 2009 16:04:37.000 00:16:45.986 5 17.593january 7, 2009 16:06:41.000 00:18:49.978 3 9.593january 7, 2009 16:07:41.000 00:19:49.975 6 21.592january 7, 2009 16:08:41.000 00:20:49.990 8 29.592january 7, 2009 16:10:17.000 00:22:25.984 3 9.593january 7, 2009 16:10:57.000 00:23:05.982 1 1.594january 7, 2009 16:12:13.000 00:24:21.977 3 9.593__________ __________ __________ __________ ____________________ __________ _____18 end of report text file section

www.emka.frwww.emka.fr

smart tools – swift services – sharp

research

www.emka.fr

sleep scoring

C

www.emka.fr

• power in up to 6 adjustable frequency ranges

• absolute and relative power values

• versatile scheduling of analysis, epoch lengths, overlap factor, windowing

POWER SPECTRUM ANALYSISEEG analyzer module withing ecgAUTO software

www.emka.fr

From top: cortex, hippocampus, muscle, sleep score, active wake, quiet wake, REM sleep, SW sleep

• easily differentiate

between

four sleep stages

• calculate global sleep

scores

• FFT power spectrums

• epileptic seizures detection

• optional video for

confirmation

of sleep score

SLEEP SCORING

www.emka.fr

Spectrum shown for each epoch - Automated and manual scores

SLEEP SCORING

www.emka.fr

SLEEP SCORING MODULE

• define thresholds applicable to any parameter from any input

• software applies logical rules to attribute 1 out of 4 sleep stages to each epoch

• trend graph displays parameters as well as sleep stages

• on the fly, adjust thresholds and see the effect on sleep scoring

• reassign scores, also using up to 15 custom labelled scores

www.emka.frwww.emka.fr

smart tools – swift services – sharp

research

www.emka.fr

www.emka.fr

SPECTRUM DATA EXPORT

Export FFT spectrum from each epoch

Possibility to group frequency data to limit number of data columns.

www.emka.frwww.emka.fr

smart tools – swift services – sharp

research

www.emka.fr

rodentPACK2 telemetry

D

www.emka.fr

TETHER-FREE EEG TELEMETRYrodentPACK2 wireless, low cost, head-mounted EEG for rodents

Acquisition of EEG and other biopotential

signals, as well as activity/ positional data

Applications are varied, e.g. sleep and

epilepsy studies, ECG and EMG recording

www.emka.fr

• head-mounted biopotential telemetry for rodents- transmits data via radiotelemetry

• humane alternative to tethered EEG

• high signal to noise ratio

• replaceable battery for lifetime monitoring

TETHER-FREE EEG TELEMETRYrodentPACK2 wireless, low cost, head-mounted EEG for rodents

www.emka.fr

• 4 biopotential signals (EEG, ECG, EMG)

each sampled at 1 kHz

• 3-axis acceleration, sampled at 50Hz on

each axis

• global acceleration (computed from 3

axes), for activity assessment

• 1 temperature, sampled at 1Hz

TETHER-FREE EEG TELEMETRYrodentPACK2 wireless, low cost, head-mounted EEG for rodents

www.emka.fr

• electrodes implanted in the subject and linked to

a connector permanently glued onto the skull

• transmitter housing amplifiers, transmission electronics

and batteries, to be coupled to the head connector prior to experiment

• receiver to read transmitted data

TETHER-FREE EEG TELEMETRYrodentPACK2 wireless, low cost, head-mounted EEG for rodents

www.emka.fr

FEATURES

Radio transmission range 5m or more

Transmission duration with same batteries: 150 hours

(cost of batteries: 3€ ($4US) / pair)

Group housing multiple animals in same cage

Up to 32 animals in same room with no required shielding

www.emka.fr

ADVANTAGES

Noise free, high quality EEG signal

EEG electrodes are rigidly welded on the head connector which is itself solidly

linked to the transmitter, therefore animal movements trigger no flexible wire

movement and cause no artefact

3-axis acceleration allowing activity and posture assessment

Very low recurring cost

no transmitter refurbishment is ever necessary

batteries cost 3€ per recording

www.emka.fr

MORE ADVANTAGES

Low investment cost

To record simultaneously from 4 rats, your complete hardware investment is less than 13k€ ($18kUS)

Even lower investment cost

By scheduling your recordings, you may further decrease cost.

For example, conducting a study on 16 subjects split in 4 groups of 4, only requires a total hardware investment of 14k€ ($20kUS)

www.emka.fr

DATA TRACESfrom rodentPACK2

5s of data from a rat - cortex, hippocampus, EMG, total acceleration

www.emka.fr

DATA TRACESfrom rodentPACK2

50s of data from a rat - cortex, hippocampus, EMG, total acceleration

www.emka.fr

FREQUENTLY ASKED QUESTIONS

Does the device alter subject behaviour?

After an acclimation of under 24 hours, the rats ignore the device. They do not « touch » it nor do they try to rub it on the cage sides

How long can the implanted electrodes and glued connector stay in place ?

Rats equipped with this types of electrodes and connectors have been routinely used for many years in tethered systems

Rats used for our tests were implanted 12 months ago and are still in good health.

No special precautions were taken during this period to keep the skin-to-glue junction clean or sterile.

www.emka.frwww.emka.fr

smart tools – swift services – sharp

research

www.emka.fr

third party data files

easyMATRIX to read telemetry implant signal

E

www.emka.fr

ANALYZING DATA FROM THIRD-PARTY SYSTEMS

emka TECHNOLOGIES analysis software can process data in the following

formats:

• produced by emka iox acquisition software

• produced by DATAQUEST or PONEMAH software

• available as text files, for example from powerLab or Biopac

• available in format such as EDF, Ishne, others

www.emka.fr

Invasive telemetry acquisition with easyMATRIX

A seamless solution to combine measurements from telemetry implants and the power of emka TECHNOLOGIES software suite

easyMATRIX

www.emka.fr

• reads signal from any type of implant through any receiver

• contains its own ambient pressure transducer

• connects to computer through USB port (no need for an add-on A/D

acquisition card)

• also runs when 2 to 4 receivers read signal from a single implant

• iox2 directly records fully calibrated data

• OpenART not required

easyMATRIX

www.emka.fr

• up to 16 receivers connect to a single easyMATRIX 

• up to 8 analog signals connect to a single easyMATRIX

• perfect synchronization between telemetry implants and analog

signals

•1 easyMATRIX manages 1 to 4 receivers per implant

• up to 4 receivers connect to a single easyMATRIX

• up to 4 easyMATRIX connect to a single computer

easyMATRIX

www.emka.fr

LEGACY & easyMATRIX SYSTEMS

4 animals with 4 receivers/animal

SETUP EXAMPLESETUP EXAMPLE

16 receivers connected to a single easyMATRIX

SETUP EXAMPLE

www.emka.frwww.emka.fr

cliquer pour ajouter un titre

solutions for lifesciences research

@emkaTECH

www.facebook.com/emkatechnologies