Post on 01-Aug-2020
DATE:CLIENT:
DESCRIPTION:
SCHAWK JOB#:SKU#:
DIMENSIONS:PRINTER SPEC:
RELEASE: V-9 LANGUAGE(S): ENGLISHINTERNAL: R-X
18211 NE 68th Street, E120 Redmond, WA 98052 T: 425-881-5454
BAN#:81552932 Rev. 09/16Contour Next LINK 2.4 QRG Canada
September 23, 2016Ascensia Diabetes CareContour Next LINK 2.4 QRG Canada English9203589755 Parent BAN# 8155891416.5” (H) x 8” (W)10000752618 REV -
FONTS: Arial, Helvetica, Helvetica Neue, Zapf Dingbats, Skinny Mini, Mini Micra, Myriad ProCOLORS: Cyan Magenta Yellow Black 281 Process Build: 100C 79M 10Y 42K
NOTE: THIS COLOR PROOF INDICATES COLOR BREAK ONLY AND MAY NOT ACCURATELY REFLECT ACTUAL PRODUCTION COLOR.Regional Master Template No: M-QRG-0347-R0002Global / EU Master Template No: M-QRG-0304-R0003
Alt#1 - 04/15/14 Copy ChangesAlt#2 - 12/01/15 Copy ChangesAlt#3 - 12/10/15 Copy ChangesAlt#4 - 12/18/15 Copy ChangesAlt#5 - 07/08/16 Copy ChangesAlt#6 - 08/17/16 Copy ChangesAlt#7 - 09/08/16 Copy Changes
Alt#8 - 09/15/16 Copy ChangesAlt#9 - 09/23/16 Copy Changes
are in search mode.
Auto ConnectBefore using AutoConnect, be sure no other nearby Medtronic devices are in search mode.
Cancel Continue
Use the arrow buttons to scroll to Continue.
Press the Select button .
MenuInsulin SettingsSensor SettingsEvent MarkersRemindersUtilities
UtilitiesSelf TestCarb UnitManage SettingsSensor DemoDevice Options
Device OptionsManage DevicesConnect Device
Active Insulin 1.5 UBolus Basal
mmol/L
BG
Search
New DeviceSee User Guide to connect new device. Select Search below when ready.
Confi rm Device SNBGJ133333F found: SN:BGJ133333F
Cancel Confi rm
Connect DeviceManual ConnectAuto Connect
5.2 mmol/LActive Insulin 1.5 UBolus Basal
BG
12:00PM
12:00PM
CONNECT TO PUMPCONNECT TO PUMP
?OKOK
SkipSkip
?OKOK
Go BackGo Back
Connect to a MiniMed Pump?
Select “ConnectDevice” on your Pump.
CONNECT TO PUMP CONNECT TO PUMP
CancelCancel
Searching...
Turn the page over to complete setup. �
®
QUICK REFERENCE GUIDE
5.2 mmolL Before Meal
Before Meal
12:00PM l 10/13
12:00PM l 10/13
BolusBolusReminderReminderNotesNotes
Uses only CONTOUR®NEXT Blood Glucose Test Strips
CONNECT TO PUMPCONNECT TO PUMP
5.2
mm
olL
Bef
ore
Mea
l B
efor
e M
eal
12:0
0P
M l
10
/13
12:0
0P
M l
10
/13
Bolu
sBo
lus
Rem
inde
rRe
min
der
Note
sNo
tes
Initial Setup of Meter and Connection to MiniMed® 630G Pump
1 Remove the USB cap to reveal the USB connector.
Charging Meter
2 To begin setup, hold down the top Menu button for several seconds until the meter turns on.
Unplug Meter From Charging Source Before Beginning Setup
Connect to Pump
3 Scroll down to select your language.
Press OK.
5 Connect to a MiniMed Pump? Press OK.
6 Press OK.
7 Put the meter down and pick up your pump.
Press any button to turn the screen on, then press the Menu button .
Use the down arrow to scroll to Utilities.
Press the Select button .
8 In the Utilities menu, use the down arrow to scroll to Device Options.
Press the Select button .
9 In the Device Options menu, scroll to Connect Device.
Press the Select button .
10 Place the meter and pump next to each other.
Select Auto Connect on your pump.
11 Read the pump screen, using the down arrow to scroll to the next page.
12 Place the meter and pump next to each other.
Select Search on the pump.
SearchSearch
CancelCancel
CONNECT TO PUMPCONNECT TO PUMP
Select “Search” on your Pump and meter.
The search may take up to 2 minutes.
13 Check to see if Device SN (serial number) on the pump matches the Device SN on the meter.
If they match, scroll to Confirm on the pump.
Press the Select button .
CONNECT TO PUMP CONNECT TO PUMP Use Pump to confirm Device SN:BGJ133333F
14 Turn the pump over.
Make sure that the SN on the back of the pump matches the pump serial number now on the meter screen.
Press Next.?
NextNext
DeleteDelete
MiniMed Pump connected:AA12345678
15 Select Always and press OK on next screen.
AlwaysAlways
Ask MeAsk Me
NeverNever
Automatically send results to the Pump?
SEND OPTIONSSEND OPTIONS
16 Select the Date Format.Month/Day/YearMonth/Day/Year
Day.Month.YearDay.Month.Year
SELECTSELECT
DATE FORMATDATE FORMAT ?
17 Press OK.
Note: If time and date are incorrect, you must change them on the pump.
OKOKDate / Time is set by Pump.
DATE / TIMEDATE / TIME?
18 Press Accept to select AutoLog is Off.
AutoLog allows you to mark a test result as Fasting, Before Meal, or After Meal. See your user guide to learn more.
AcceptAccept
Turn OnTurn On
AutoLog is Off.AUTOLOGAUTOLOG
?
Wireless Blood Glucose Monitoring System
?
Manual ConnectManual Connect
Auto ConnectAuto Connect
CONNECT TO PUMPCONNECT TO PUMP
4 Press OK if the correct language is displayed. Press NO if the incorrect language is displayed.
*Wall charger may not be included in all meter kits. Contact Customer Service for information on obtaining a wall charger.
If pump screen goes blank, press any button to turn it back on.
When the pump links to the meter, the SN on the meter screen will change to a different serial number. This number is the pump SN.
PUMP CONNECTEDPUMP CONNECTED
®®
Select Auto Connect on your meter.
Select Search on the meter.
10:30PM | 10/13/11
EnglishDeutschEspañol
LANGUAGELANGUAGE
OKOK
81552932
R
ev.
09/1
6Display Screen
The CONTOUR®NEXT LINK 2.4 meter has a permanent rechargeable battery.
Charge your meter with the wall charger * or by plugging the USB connector into a computer. Be sure the computer is turned on.
Your meter will briefly display “Do Not Test–Charging” and the test strip port light will flash. You cannot do a blood glucose test while the battery is charging.
When charging is finished, the test strip port light will turn off. Unplug your CONTOUR NEXT LINK 2.4 meter to test.
USB Connector
Selection/Scrolling Buttons
Test Strip Port
Display Screen
Test Strip Port
Light
Top Menu
Button
Protective USB Cap
Meter Pump
Menu
Select
Right
Up
Back
Notification Light
Left
Down
NOTE: Check the units of measure of your meter. See your meter user guide for complete instructions.
p, e ton
the n.
From Charging Beginning SeSetutupp
ng is finished, the test strip port light willug your CONTOUR NEXT LINK 2.4
81552932_CntrNextLINK2_4_QRG_EN_FpBp_v9 1 09/23/16 9:27 AM
WARNING:• The lancing device is intended for self-testing by a single patient. It must not be used on more than one person
due to the risk of infection.
• Use a new lancet each time you test because it is no longer sterile after use.
• All parts of the kit are considered biohazardous and can potentially transmit infectious diseases, even after you
have performed cleaning and disinfection.
• Always wash your hands well with soap and water before and after testing, handling the meter, lancing device,
or test strips.
For complete instructions on cleaning and disinfecting your meter, please see your meter user guide.
Press Send or Don't Send.
BG
9.3 mmol/L
Calibrate SensorBolus
Done
The lancing device graphics are for illustration purposes only. Your lancing device may look different. Refer to your lancing device insert for detailed instructions on preparing the lancing device.
9.3 mmolL
SentSent
10:30PM l 11/1310:30PM l 11/13
9.3 mmolL
YOUR RESULTSYOUR RESULTS
BolusBolus
Reminder Reminder
NotesNotes
9.3 mmol/L
Calibrate SensorBolus
Done
cing device.
2 Remove the lancing device endcap.
Insert the lancet firmly into the lancing device until it comes to a full stop.
1 Insert the test strip and wait for the APPLY BLOOD message.
3 Replace the endcap. Rotate the endcap dial to adjust the puncture depth.
4 Obtain your blood drop.
5 Touch the tip of the test strip to the drop of blood. If the first blood drop is not enough, the meter will beep twice and display STRIP UNDERFILLED. You have about 30 seconds to apply more blood to the same strip.
7 Select Bolus to send a bolus to your pump. Select Reminder to set a reminder for your next test. Select Notes to add more information to the result.
9 Remove the test strip and the meter will turn off in 3 minutes. Or hold down the Menu button to turn off the meter.
8 Pick up your pump.
Press and hold the Back
button to get to the home screen. Your blood sugar result should display on the pump screen.
Obtain Blood Drop
Testing Blood Drop
Bolus, Reminder and Notes
Turn Meter Off
Confirm That Result Was Sent to Pump
See your CONTOUR®NEXT LINK 2.4 user guide, lancing device insert and MiniMed pump user guide for full instructions.
6 If Always was selected in Send Options during Setup, results will be sent directly to your pump. If Ask Me was selected in Send Options during Setup, you can choose to send your result to your pump after each blood sugar test.
Testing Your Blood
Sending Results to Your MiniMed Pump
20 Accept or Change your Target range.
The Target range is your goal for your blood sugar test results.
?AcceptAccept
ChangeChange
TARGETTARGET
3.9 - 10.03.9 - 10.021 Your system setup is now
complete and ready to run a blood sugar test.
Go to Step 1 below.
Setup is complete.Insert strip to start a test.
?
SendSend
Don't SendDon't Send
19 Accept or Change High and Low Alerts.
The meter alerts you with a sound when your blood sugar level is above or below your set levels.
AcceptAccept
ChangeChange
?HIGH AND LOW ALERTSHIGH AND LOW ALERTS
High: 13.9 High: 13.9 mmol/Lmmol/L
Low: 3.9 Low: 3.9 mmol/Lmmol/L
NOTE: If AutoLog is ON, you are asked to mark your result as Fasting, Before Meal, or After Meal before your result displays. If your result is above your High Alert setting or below your Low Alert setting, you will see your result without having to make an AutoLog selection.
NOTE: Alerts can only be set outside your selected Target Range(s). Targets can only be set inside your selected Alert level(s). For additional information, you may contact Customer Service. See contact information for Customer Service below.
CAUTION: Always check the display on your pump to ensure that the glucose result shown agrees with the glucose result shown on the meter.
For more information, go to www.diabetes.ascensia.com or contact Customer Service at: 1-800-268-7200
For In Vitro Diagnostic Use
Ascensia, the Ascensia Diabetes Care logo, Clinilog, Contour, Glucofacts, and the No Coding logo are trademarks and/or registered trademarks of Ascensia Diabetes Care Holdings AG.
TM see www.ascensiadiabetes.ca/en/tm-mcwww.diabetes.ascensia.com
Bolus Wizard, CareLink, Guardian, MiniMed, and Paradigm are trademarks and/or registered trademarks of Medtronic MiniMed, Inc.
© 2016 Ascensia Diabetes Care Holdings AG. All rights reserved.
For information on patents, and related licenses, see:
www.patents.ascensia.comAscensia Diabetes Care Holdings AGPeter Merian-Strasse 904052 Basel, Switzerland
Manufactured for:
Lancing Device CONTOUR®NEXT
Test Strip
Lancet
CONTOUR®NEXT LINK 2.4 Blood Glucose Meter
Materials for Testing
81552932_CntrNextLINK2_4_QRG_EN_FpBp_v9 09/23/16 9:27 AM