Download - Solar Water Heater - Hubbell · PDF fileA solar water heater with 119 gallon ... mark certifying the entire water heater. The cold water inlet shall be ... operated within the scope

Transcript
  • A Highly Efficient And Long Lasting Water Heater

    Features Heavy Duty Construction Hydrastonecementliningprovideslonger

    tanklife Copper-silicontappingscannotrustor

    corrode Highimpactcompositejacketcannotrust

    orcorrodeandeliminatesdamageduringtransitandinstallation

    High Efficiency 2"thickpolyurethanefoaminsulation

    meetsorexceedsthelatestrequirementsofANSI/ASHRAE/IESNA

    Built-inheattraplowersoperatingcosts

    Advanced Heating Coil Fullyremovablecoilforsimple

    maintenance Copperfintubedesignprovides

    maximumheattransfer

    A Highly Efficient Water Heater Utilizes Solar Energy

    TheHubbellmodelSLNsolarwaterheateroperatesbytransferringheatfromanexistingsolarcollectorsystemtoyourdomesticpotablewatersystem.TheModelSLNstoragetankisfittedwithacoilthatacceptsheatedsolarcollectorwaterandtransfersthatheattothedomesticwaterinthetank.Thesolarcollectorwaterandpotablewaterremainastwoseparatesystemsthatdonotmix,onlytheheat

    energyistransferred.ThehighlyefficientModelSLNisalonglastingwaterheaterthathasnomovingpartsanddoesnotrequireanyelectricalconnections.WhenyouspecifyandinstallaHubbellModelSLNsolarwaterheater,youwillhaveconfidenceinknowingtheownerwillbeprovidedwithaqualityproductthatisatrouble-freeandlonglastingsourceforhotwater.

    Applications Residential IndustrialFacilities Schools Anysystemwhichutilizessolarcollectors/panels

    Model SLN

    MODEL SLN

    NOGLASSLINING

    NOGLASSLINING

    Solar Water Heater65-119 Gallon Capacity

  • 2

    Model SLNWater Heater SpecificationsTank:Capacities:Orientation:InletSize:OutletSize:DrainSize:ReliefValve

    Opening:Type:

    TankRating:

    HydrastoneCementLinedSteel 65-119GallonsVertical3/4"FemaleNPT3/4"MaleNPT3/4"GHTHoseConnection

    3/4"FemaleNPTT&P,210oF,150psi

    150psiWP,300psiTP

    StandbyHeatLoss: 0.39oF/HrTypical

    CoilConstructionType: RemovableMaterial: CopperFinTubeRating: 150psiWP,300psiTP

    Warranty(Residential):Tank: 7YearsNonPro-RatedCoil: 7YearsNonPro-Rated

    Warranty(Commercial):Tank: 5YearsNonPro-RatedCoil: 5YearsNonPro-Rated

    Jacket: HighImpactColorizedComposite

    Insulation: 2"PolyurethaneFoamColor: WhiteandBlack

    Optional Equipment1. Doublewallheatingcoilwithaleakdetectionport2. 11/2"MaleNPTinletandoutletwaterconnections3. Electricheatingelementforback-upheating,please

    specifywattageandvoltage.4. Integrallyweldedseismicattachmentpoints5. 3"Polyurethanefoaminsulation6. Secondaryheatingcoil(CoilS13only)locatedin

    upperportionoftankforauxiliaryheating.

    Voltage Phase KWRatingsAvailable120 1 1.5, 2

    208,240,277,480 1 3, 4, 4.5, 5, 6208thru600 3 6, 8, 10, 12, 15, 20

    Back-up Electric Heating Element Selection Chart

    Base Storage Coil Coil Coil 1stHour Continuous SolarModel Capacity Model Type Connection Ratings DemandRating FlowRate

    (Gallons) Size(NPT) (Gallons) (Gal/Hr) (GPM)S13 SingleWall 3/4" 162 98 3.5

    SLN65 65S15 SingleWall 3/4" 210 150 8S20 SingleWall 1" 295 235 14D10 DoubleWall 1/2" 120 60 3.5S13 SingleWall 3/4" 175 98 3.5

    SLN80 80S15 SingleWall 3/4" 222 150 8S20 SingleWall 1" 307 235 14D10 DoubleWall 1/2" 132 60 3.5S13 SingleWall 3/4" 211 98 3.5

    SLN120 119S15 SingleWall 3/4" 254 150 8S20 SingleWall 1" 339 235 14D10 DoubleWall 1/2" 164 60 3.5

    Heating Coil Selection Chart with Recovery Ratings

    20

    25

    15

    10

    5

    02 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SolarWaterFlow(GPM)

    PressureDrop(psi) 1

    2

    3

    4

    4" Flange, Single Wall 3/4" In/Out, Hubbell Coil Model No. S13

    6" Flange, Double Wall 1/2" In/Out, Hubbell Coil Model No. D10

    6" Flange, Single Wall 3/4" In/Out, Hubbell Coil Model No. S15

    6" Flange, Single Wall 1" In/Out, Hubbell Coil Model No. S20

    1

    2

    3

    4

    Recoveryratingsbaseduponthesupplyof180oFsolarwatertotheheatingcoiltoheatdomesticpotablewaterfrom58-135oF

    Please note: optional equipment may impact overall dimensions and weight. Please request submittal drawing from factory.

  • 3

    Outline Dimensions

    Side ViewFront View

    18"Withdrawal

    Space

    Tank Cross Section

    Hot Water Outlet

    T&P Relief Valve

    Protective Jacket

    Solar Water Out

    Top View

    Combination Cold Water Inlet And Drain

    Thermostat and Hi-limit for Back-

    up Element

    2" Foam Insulation

    Solar Water In

    Thermistor Clip

    Immersion Thermowell

    Heating Coil

    Step3

    CoilModel:Seecoilselectionchart:S13,S15,S20D10

    Step2

    StorageCapacity: 65-119Gallons

    Example:SLN120S15-4.5S-1

    Step1

    Model:SLNStep4

    KWSelection:1.5-20KWSeechartonpreviouspage

    Step5

    Voltage/Phase/Hz:A = 120-1-60RS = 208-1-60R = 208-3-60S = 240-1-60T = 240-3-60W = 277-1-60T4S=480-1-60T3 = 380-3-50/60T7 = 415-3-50/60T5 = 440-3-60T4 = 480-3-60

    Model Number Designation

    SLN

    Step6

    No.Elements:1 =UpperPosition

    Only(Single)2 =UpperandLower

    Position(Dual)

    Complete this section only when specifying a back-up electric heating element.

    Asolarwaterheaterwith119gallonstoragecapacityanda3/4"singlewallheatexchangercoilwithone4.5KWback-upelectricheatingelementratedat240volt1phase.

    OptiON NOteAnyandalloptionalequipmentforawaterheatermustbecalledoutinthewrittenspecifications.Amodelnumberinandofitselfdoesnotreflectanyoptionalequipmentselected.

    Storage DimensionalData(Inches)Base Capacity Overall Overall Inlet Coil T&PValve Outlet ShippingModel (Gallons) Diameter Height A B C Weight(lbs.)

    SLN65 65 26 48 8 10 40 Top 310SLN80 80 26 58 8 11 51 Top 340SLN120 119 28 69.5 8 11 61 Top 420

    Steel Pressure Vessel

    1/2"Back-up Element

    (optional)

    T&P Relief Valve

    Hot Water Outlet

    45o45o

    AB

    C

    Removable Heat Exchange Coil

    55o

    Immersion Thermowell

    Hydrastone

  • JOBNAME

    REPRESENTATIVE

    ENGINEER

    CONTRACTOR

    The Electric Heater Company P.O. Box 288 Stratford, CT 06615-0288 Phone: 203-378-2659 Fax: [email protected] www.hubbellheaters.com

    ISO 9001:2008 ISO

    Committed to continuous improvement...Continuing research results in product improvement; therefore specifications are subject to

    change without notice. For the most updated information, consult the factory directly.

    MadeintheU.S.A.

    Master Specification: Model SLN

    GENERALProvideaquantityof Solarwaterheater(s)ModelNo. asmanufacturedbyHUBBELLElectricHeaterCo.,Stratford,CT.Theentireunitistobecompletewithalloperatingcontrolsandisreadyforplumbingserviceconnections.Thetankshallbeallweldedsteelcommercialconstructiondesignedfor150psiworkingpressureandcontain

    gallonsofstorage.ThetankistobelinedwithseamlessHydrastonecementtoaminimumthicknessof1/2"on100%ofallinteriortanksurfacesanddoesnotrequireanytypeofanodicprotection.Thetankshallbefabricatedwithnon-ferrouscopper-siliconthreadedtappingsandnon-ferrousinletandoutletpipingformaximumcorrosionresistance.Steeltanktappingsshallnotbeacceptable.Theentiretankistobeinsulatedwithaminimumof2"( OptionalSpecification:3")thick polyurethanefoaminsulationandexceedthelatestASHRAEstandardforstand-byheatloss.Thecompleteheatershallbesuppliedwithahighimpactcolorizedcompositeprotectivejacketwhichcannotrustorcorrodeanddoesnotrequirepainting.TheunitshallbeartheULlistingmarkcertifyingtheentirewaterheater.

    Thecoldwaterinletshallbe3/4"FemaleNPT( OptionalSpecification:11/2"MaleNPT )andincludeanon-corrosivestrata-flowdiffuserwhichpreventsincomingcoldwaterfrommixingtoorapidlywithhotwaterinthetank.A3/4"hoseconnectiondrainissupplied.Thehotwateroutletconnectionshallbe3/4"MaleNPT( OptionalSpecification:11/2"MaleNPT)and shallincludeafactoryinstalledbuilt-inheattraptopreventwaterfromradiatingthroughthepipingduringstand-byperiods.Aseparate3/4"FemaleNPTtappingistobeprovidedforreliefvalveinstallation.AnASMEratedautomaticreseatingcombinationtemperatureandpressuresafetyreliefvalvesetat150psiand210oFshallbefactorysupplied.

    HEATING COILThetankshallbesuppliedwithaheatingcoilwhichtransfersheatfromthesolarpanelsystemtothedomesticwater.Solarpanelwatershallbeinthetubes,anddomesticwaterinthetank.Theheatingcoilshallbeofsinglewall( OptionalSpeci ication:doublewall )copperconstructionformaximumheattransferefficiencyandcoillongevity.The heatingcoilshallbefullyremovablefromthetanktoallowforperiodicinspectionandmaintenancewithouttheneedtomoveorliftthestoragetankfromitsinstalledposition.Amountingclipandimmersionthermowellaresuppliedforinstallationofathermistor(byothers)forsensingthewatertemperatureinthetank.

    OPTION BACK-UPHEATERTheSolarwaterheaterwillbesuppliedwithaback-upheater.Theback-upheatershallbeasingleelectricimmersionheatingelement( OptionalSpecification:119gallonmodelsonly:adualupperandlowerelement)ratedat KW eachanddesignedtooperateat volts phase Hzwithallnecessaryoperatingcontrolsfactorymountedwiredandtested.Theheatingelement(s)shallbecopperorincoloysheathelectricimmersiontypesizedtoobtaintheratedrecovery.Watertemperatureshallbecontrolledthroughanadjustable110-170oFsnapactionsurfacethermostat.Anover-temperaturemanualresetHi-Limitshallbefactoryinstalledtodisconnectallconductorstotheheatingelementintheeventofanover-temperatureconditioninthepressurevessel.

    WARRANTYThewaterheatermanufacturershallwarrantyallelectricalcomponentsagainstdefectsinworkmanshipandmaterialforaperiodofone(1)yearfromdateofstart-up,andthepressurevesselincludingtheheatingcoilforafullseven(7)yearsNonPro-Ratedforresidentialapplicationsandfive(5)yearsforcommercialapplicationsfromdateofstart-up,providedthattheunitisstartedwithinthree(3)monthsofdateofshipmentandinstalledandoperatedwithinthescopeofthetankdesignandoperatingcapability.Eachwaterheatershallbeshippedwithacompletesetofinstallationandoperati