Solar Water Heater - Hubbell · PDF fileA solar water heater with 119 gallon ... mark...

download Solar Water Heater - Hubbell · PDF fileA solar water heater with 119 gallon ... mark certifying the entire water heater. The cold water inlet shall be ... operated within the scope

If you can't read please download the document

Transcript of Solar Water Heater - Hubbell · PDF fileA solar water heater with 119 gallon ... mark...

  • A Highly Efficient And Long Lasting Water Heater

    Features Heavy Duty Construction Hydrastonecementliningprovideslonger

    tanklife Copper-silicontappingscannotrustor

    corrode Highimpactcompositejacketcannotrust

    orcorrodeandeliminatesdamageduringtransitandinstallation

    High Efficiency 2"thickpolyurethanefoaminsulation

    meetsorexceedsthelatestrequirementsofANSI/ASHRAE/IESNA

    Built-inheattraplowersoperatingcosts

    Advanced Heating Coil Fullyremovablecoilforsimple

    maintenance Copperfintubedesignprovides

    maximumheattransfer

    A Highly Efficient Water Heater Utilizes Solar Energy

    TheHubbellmodelSLNsolarwaterheateroperatesbytransferringheatfromanexistingsolarcollectorsystemtoyourdomesticpotablewatersystem.TheModelSLNstoragetankisfittedwithacoilthatacceptsheatedsolarcollectorwaterandtransfersthatheattothedomesticwaterinthetank.Thesolarcollectorwaterandpotablewaterremainastwoseparatesystemsthatdonotmix,onlytheheat

    energyistransferred.ThehighlyefficientModelSLNisalonglastingwaterheaterthathasnomovingpartsanddoesnotrequireanyelectricalconnections.WhenyouspecifyandinstallaHubbellModelSLNsolarwaterheater,youwillhaveconfidenceinknowingtheownerwillbeprovidedwithaqualityproductthatisatrouble-freeandlonglastingsourceforhotwater.

    Applications Residential IndustrialFacilities Schools Anysystemwhichutilizessolarcollectors/panels

    Model SLN

    MODEL SLN

    NOGLASSLINING

    NOGLASSLINING

    Solar Water Heater65-119 Gallon Capacity

  • 2

    Model SLNWater Heater SpecificationsTank:Capacities:Orientation:InletSize:OutletSize:DrainSize:ReliefValve

    Opening:Type:

    TankRating:

    HydrastoneCementLinedSteel 65-119GallonsVertical3/4"FemaleNPT3/4"MaleNPT3/4"GHTHoseConnection

    3/4"FemaleNPTT&P,210oF,150psi

    150psiWP,300psiTP

    StandbyHeatLoss: 0.39oF/HrTypical

    CoilConstructionType: RemovableMaterial: CopperFinTubeRating: 150psiWP,300psiTP

    Warranty(Residential):Tank: 7YearsNonPro-RatedCoil: 7YearsNonPro-Rated

    Warranty(Commercial):Tank: 5YearsNonPro-RatedCoil: 5YearsNonPro-Rated

    Jacket: HighImpactColorizedComposite

    Insulation: 2"PolyurethaneFoamColor: WhiteandBlack

    Optional Equipment1. Doublewallheatingcoilwithaleakdetectionport2. 11/2"MaleNPTinletandoutletwaterconnections3. Electricheatingelementforback-upheating,please

    specifywattageandvoltage.4. Integrallyweldedseismicattachmentpoints5. 3"Polyurethanefoaminsulation6. Secondaryheatingcoil(CoilS13only)locatedin

    upperportionoftankforauxiliaryheating.

    Voltage Phase KWRatingsAvailable120 1 1.5, 2

    208,240,277,480 1 3, 4, 4.5, 5, 6208thru600 3 6, 8, 10, 12, 15, 20

    Back-up Electric Heating Element Selection Chart

    Base Storage Coil Coil Coil 1stHour Continuous SolarModel Capacity Model Type Connection Ratings DemandRating FlowRate

    (Gallons) Size(NPT) (Gallons) (Gal/Hr) (GPM)S13 SingleWall 3/4" 162 98 3.5

    SLN65 65S15 SingleWall 3/4" 210 150 8S20 SingleWall 1" 295 235 14D10 DoubleWall 1/2" 120 60 3.5S13 SingleWall 3/4" 175 98 3.5

    SLN80 80S15 SingleWall 3/4" 222 150 8S20 SingleWall 1" 307 235 14D10 DoubleWall 1/2" 132 60 3.5S13 SingleWall 3/4" 211 98 3.5

    SLN120 119S15 SingleWall 3/4" 254 150 8S20 SingleWall 1" 339 235 14D10 DoubleWall 1/2" 164 60 3.5

    Heating Coil Selection Chart with Recovery Ratings

    20

    25

    15

    10

    5

    02 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SolarWaterFlow(GPM)

    PressureDrop(psi) 1

    2

    3

    4

    4" Flange, Single Wall 3/4" In/Out, Hubbell Coil Model No. S13

    6" Flange, Double Wall 1/2" In/Out, Hubbell Coil Model No. D10

    6" Flange, Single Wall 3/4" In/Out, Hubbell Coil Model No. S15

    6" Flange, Single Wall 1" In/Out, Hubbell Coil Model No. S20

    1

    2

    3

    4

    Recoveryratingsbaseduponthesupplyof180oFsolarwatertotheheatingcoiltoheatdomesticpotablewaterfrom58-135oF

    Please note: optional equipment may impact overall dimensions and weight. Please request submittal drawing from factory.

  • 3

    Outline Dimensions

    Side ViewFront View

    18"Withdrawal

    Space

    Tank Cross Section

    Hot Water Outlet

    T&P Relief Valve

    Protective Jacket

    Solar Water Out

    Top View

    Combination Cold Water Inlet And Drain

    Thermostat and Hi-limit for Back-

    up Element

    2" Foam Insulation

    Solar Water In

    Thermistor Clip

    Immersion Thermowell

    Heating Coil

    Step3

    CoilModel:Seecoilselectionchart:S13,S15,S20D10

    Step2

    StorageCapacity: 65-119Gallons

    Example:SLN120S15-4.5S-1

    Step1

    Model:SLNStep4

    KWSelection:1.5-20KWSeechartonpreviouspage

    Step5

    Voltage/Phase/Hz:A = 120-1-60RS = 208-1-60R = 208-3-60S = 240-1-60T = 240-3-60W = 277-1-60T4S=480-1-60T3 = 380-3-50/60T7 = 415-3-50/60T5 = 440-3-60T4 = 480-3-60

    Model Number Designation

    SLN

    Step6

    No.Elements:1 =UpperPosition

    Only(Single)2 =UpperandLower

    Position(Dual)

    Complete this section only when specifying a back-up electric heating element.

    Asolarwaterheaterwith119gallonstoragecapacityanda3/4"singlewallheatexchangercoilwithone4.5KWback-upelectricheatingelementratedat240volt1phase.

    OptiON NOteAnyandalloptionalequipmentforawaterheatermustbecalledoutinthewrittenspecifications.Amodelnumberinandofitselfdoesnotreflectanyoptionalequipmentselected.

    Storage DimensionalData(Inches)Base Capacity Overall Overall Inlet Coil T&PValve Outlet ShippingModel (Gallons) Diameter Height A B C Weight(lbs.)

    SLN65 65 26 48 8 10 40 Top 310SLN80 80 26 58 8 11 51 Top 340SLN120 119 28 69.5 8 11 61 Top 420

    Steel Pressure Vessel

    1/2"Back-up Element

    (optional)

    T&P Relief Valve

    Hot Water Outlet

    45o45o

    AB

    C

    Removable Heat Exchange Coil

    55o

    Immersion Thermowell

    Hydrastone

  • JOBNAME

    REPRESENTATIVE

    ENGINEER

    CONTRACTOR

    The Electric Heater Company P.O. Box 288 Stratford, CT 06615-0288 Phone: 203-378-2659 Fax: [email protected] www.hubbellheaters.com

    ISO 9001:2008 ISO

    Committed to continuous improvement...Continuing research results in product improvement; therefore specifications are subject to

    change without notice. For the most updated information, consult the factory directly.

    MadeintheU.S.A.

    Master Specification: Model SLN

    GENERALProvideaquantityof Solarwaterheater(s)ModelNo. asmanufacturedbyHUBBELLElectricHeaterCo.,Stratford,CT.Theentireunitistobecompletewithalloperatingcontrolsandisreadyforplumbingserviceconnections.Thetankshallbeallweldedsteelcommercialconstructiondesignedfor150psiworkingpressureandcontain

    gallonsofstorage.ThetankistobelinedwithseamlessHydrastonecementtoaminimumthicknessof1/2"on100%ofallinteriortanksurfacesanddoesnotrequireanytypeofanodicprotection.Thetankshallbefabricatedwithnon-ferrouscopper-siliconthreadedtappingsandnon-ferrousinletandoutletpipingformaximumcorrosionresistance.Steeltanktappingsshallnotbeacceptable.Theentiretankistobeinsulatedwithaminimumof2"( OptionalSpecification:3")thick polyurethanefoaminsulationandexceedthelatestASHRAEstandardforstand-byheatloss.Thecompleteheatershallbesuppliedwithahighimpactcolorizedcompositeprotectivejacketwhichcannotrustorcorrodeanddoesnotrequirepainting.TheunitshallbeartheULlistingmarkcertifyingtheentirewaterheater.

    Thecoldwaterinletshallbe3/4"FemaleNPT( OptionalSpecification:11/2"MaleNPT )andincludeanon-corrosivestrata-flowdiffuserwhichpreventsincomingcoldwaterfrommixingtoorapidlywithhotwaterinthetank.A3/4"hoseconnectiondrainissupplied.Thehotwateroutletconnectionshallbe3/4"MaleNPT( OptionalSpecification:11/2"MaleNPT)and shallincludeafactoryinstalledbuilt-inheattraptopreventwaterfromradiatingthroughthepipingduringstand-byperiods.Aseparate3/4"FemaleNPTtappingistobeprovidedforreliefvalveinstallation.AnASMEratedautomaticreseatingcombinationtemperatureandpressuresafetyreliefvalvesetat150psiand210oFshallbefactorysupplied.

    HEATING COILThetankshallbesuppliedwithaheatingcoilwhichtransfersheatfromthesolarpanelsystemtothedomesticwater.Solarpanelwatershallbeinthetubes,anddomesticwaterinthetank.Theheatingcoilshallbeofsinglewall( OptionalSpeci ication:doublewall )copperconstructionformaximumheattransferefficiencyandcoillongevity.The heatingcoilshallbefullyremovablefromthetanktoallowforperiodicinspectionandmaintenancewithouttheneedtomoveorliftthestoragetankfromitsinstalledposition.Amountingclipandimmersionthermowellaresuppliedforinstallationofathermistor(byothers)forsensingthewatertemperatureinthetank.

    OPTION BACK-UPHEATERTheSolarwaterheaterwillbesuppliedwithaback-upheater.Theback-upheatershallbeasingleelectricimmersionheatingelement( OptionalSpecification:119gallonmodelsonly:adualupperandlowerelement)ratedat KW eachanddesignedtooperateat volts phase Hzwithallnecessaryoperatingcontrolsfactorymountedwiredandtested.Theheatingelement(s)shallbecopperorincoloysheathelectricimmersiontypesizedtoobtaintheratedrecovery.Watertemperatureshallbecontrolledthroughanadjustable110-170oFsnapactionsurfacethermostat.Anover-temperaturemanualresetHi-Limitshallbefactoryinstalledtodisconnectallconductorstotheheatingelementintheeventofanover-temperatureconditioninthepressurevessel.

    WARRANTYThewaterheatermanufacturershallwarrantyallelectricalcomponentsagainstdefectsinworkmanshipandmaterialforaperiodofone(1)yearfromdateofstart-up,andthepressurevesselincludingtheheatingcoilforafullseven(7)yearsNonPro-Ratedforresidentialapplicationsandfive(5)yearsforcommercialapplicationsfromdateofstart-up,providedthattheunitisstartedwithinthree(3)monthsofdateofshipmentandinstalledandoperatedwithinthescopeofthetankdesignandoperatingcapability.Eachwaterheatershallbeshippedwithacompletesetofinstallationandoperati