Download - SK1000 Sine Wave Inverter

Transcript
Page 1: SK1000 Sine Wave Inverter

7/23/2019 SK1000 Sine Wave Inverter

http://slidepdf.com/reader/full/sk1000-sine-wave-inverter 1/2

1000W Pure Sine Wave Inverters SK 

FEATURES

True sine wave output (THD < 3%)

Power ON-OFF remote control

Input & output fully isolation

Load control cooling fan

 Advanced microprocessor 

Output frequency 50/60 Hz switch selectable

Low power saving mode to conserve energy

Input polarity reverse / under voltage / over voltage protections

Output short circuit / overload / over temperature protections

Tri-color indicators display input, output level & failure status

e-13 / CE / FCC approved

North America (GFCI)NEMA 5-15R   Schuko

Australia

New Zealand   United KingdomUniversal

OUTPUT

INPUT

AC VOLTAGERATED POWER

SURGE POWER

WAVEFORM

FREQUENCY

AC REGULATION

STANDARD RECEPTACLES

LED INDICATOR

NO LOAD CURRENT DRAW

VOLTAGE RAN GE

EFFICIENCY(Typ.)

FUSE

REMOTE CONTROL UNIT

100 / 110 / 120VAC1000W

2000W

True sine wave (THD < 3%)

50 / 60 Hz selectable by DIP switch

NEMA5-15R / GFCI

Input voltage level, output load level and fault status

CR6 / CR8 optional

SK1000-112   SK1000-124   SK1000-148   SK1000-212

220 / 230 / 240 VAC

Schuko / UK / Australia / Universal

0.38A

12VDC

1.20A   0.60A

10.5~15.0VDC

POWER FACTORALLOWED   COS -90  O ~ COS +90

  O

MODEL No.   SK1000-224   SK1000-248

1.43A   0.75A 0.28A

DC VOLTAGE

STAND-BY CURRENT DRAW   0.25A   0.15A   0.09A   0.08A0.15A0.25A

24VDC   48VDC   12VDC   24VDC 48VDC

21.0~30.0VDC   4 2. 0~ 60 VD C 1 0. 5~ 15 .0 VD C 2 1. 0~ 30 .0 VD C 4 2. 0~ 60 VD C

92.0%89.0%   93.0% 91.0%   94.0%93.0%

20A x 240A x 4   20A x 4

PROTECTION

ENVIRONMENT

SAFETY& EMC

OTHERS

BAT. LOW SHUTDO WN

OVER LOAD

OVER VO LTAGE

OVER TEMPERATURE

OUTPUT SHORT

BAT. POLARI TY

WORKING TEMP.

WORKING HUMIDITY

STORAGE TEMP. HUMIDITY

SAFETYSTANDARDS

ISOLATION RESISTANCE

EMI CONDUCTION & RADIATION

EMS IMMUNITY

LVD

e-MARK

DIMENSION

PACKING

COOLING

APPLICATION

10.5VDC

Shut off output voltage, re-power on to recover 

15.3VDC

Shut off output voltage, recovers automatically after temperature goes down

Shut off output voltage, re-power on to recover 

By fuse open

0 ~ +40 C

20% ~ 90% RH non-condensing

- 30 C ~ + 70 / C - 2 2 F ~ + 1 58 F / 1 0 ~9 5 %

Meet UL458

I/P ~ O/P: 100M Ohms / 500VDC

Compliance to FCC classA

-----

-----

-----

383 x 182 x 88mm (L x W x H)

4.0kgs; 4sets / 20kgs / CARTON

Home and Office applianc es, Power tools and Portable equi pments, Vehicle, Yacht and Solar power systems …etc.

30.6VDC

-----

Compliance to EN55022 class A

Compliance to EN61000-3 -2, 3

Compliance to EN60950-1

Compliance to e-13 * 72/245/EEC, 95/54/EC

BAT. LOWALA RM   11VDC 22VDC 44VDC   11VDC 22VDC 44VDC

21.0VDC 42.0VDC 10.5VDC 21.0VDC 42.0VDC

Loading controlled cooling fan

61.2VDC   15.3VDC   30.6VDC 61.2VDC

  %3

20A x 240A x 4   20A x 4

e13

Page 2: SK1000 Sine Wave Inverter

7/23/2019 SK1000 Sine Wave Inverter

http://slidepdf.com/reader/full/sk1000-sine-wave-inverter 2/2