SK1000 Sine Wave Inverter

2
1000W Pure Sine Wave Inverters SK FEATURES True sine wave output (THD < 3%) Power ON-OFF remote control Input & output fully isolation Load control cooling fan  Advanced microproc essor Output frequency 50/60 Hz switch selecta ble Low power saving mode to conserve energy Input polarity reverse / under voltage / over voltage protectio ns Output short circuit / overload / over temperature protections Tri-colo r indicators display input, output level & failure status e-13 / CE / FCC approved North America (GFCI) NEMA 5-15R  Schuko Australia New Zealand  United Kingdom Universal OUTPUT INPUT AC VOLTAGE RATED POWER SURGE POWER WAVEFORM FREQUENCY AC REGULATION STANDARD RECEPTACLES LED INDICATOR NO LOAD CURRENT DRAW VOLTAGE RAN GE EFFICIENCY(Typ.) FUSE REMOTE CONTROL UNIT 100 / 110 / 120VAC 1000W 2000W True sine wave (THD < 3%) 50 / 60 Hz selectable by DIP switch NEMA5-15R / GFCI Input voltage level, output load level and fault status CR6 / CR8 optional SK1000-112  SK1000-124  SK1000-148  SK1000-212 220 / 230 / 240 VAC Schuko / UK / Australia / Universal 0.38A 12VDC 1.20A  0.60A 10.5~15.0VDC POWER FACTORALLOWED  COS -90  O ~ COS +90  O MODEL No.  SK1000-224  SK1000-248 1.43A  0.75A 0.28A DC VOLTAGE STAND- BY CURRENT DRAW  0.25A  0.15A  0.09A  0.08A 0.15A 0.25A 24VDC  48VDC  12VDC  24VDC 48VDC 21.0~30.0VDC  42. 0~ 60 VDC 1 0. 5~ 15. 0VDC 21. 0~ 30. 0VDC 42.0~60VDC 92.0% 89.0%  93. 0% 91. 0%  94.0% 93.0% 20A x 2 40A x 4  20A x 4 PROTECTION ENVIRONMENT SAFETY& EMC OTHERS BAT. LOW SHUTDO WN OVER LOAD OVER VO LT AGE OVER TEMPERATURE OUTPUT SHORT BAT. POLARI TY WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. HUMIDITY SAFETYSTANDARDS ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMS IMMUNITY LVD e-MARK DIMENSION PACKING COOLING APPLICATION 10.5VDC Shut off output voltage, re-power on to recover 15.3VDC Shut off output voltage, recovers automatically after temperature goes down Shut off output voltage, re-power on to recover By fuse open 0 ~ +40 C 20% ~ 90% RH non-condensing -30 C ~ +70 / C -22 F ~ +158 F / 10~95% Meet UL458 I/P ~ O/P: 100M Ohms / 500VDC Compliance to FCC classA ----- ----- ----- 383 x 182 x 88mm (L x W x H) 4.0kgs; 4sets / 20kgs / CARTON Home and Office applianc es, Power tools and Portable equi pments, Vehicle, Yacht and Solar power systems …etc. 30.6VDC ----- Compliance to EN55022 class A Compliance to EN61000-3 -2, 3 Compliance to EN60950-1 Compliance to e-13 * 72/245/EEC, 95/54/EC BAT . LOWALA RM  11VDC 22VDC 44VDC  11VDC 22VDC 44VDC 21.0VDC 42.0VDC 10. 5VDC 21. 0VDC 42. 0VDC Loading controlled cooling fan 61.2VDC  15.3VDC  30. 6VDC 61. 2VDC  % 3 20A x 2 40A x 4  20A x 4 e1 3

Transcript of SK1000 Sine Wave Inverter

Page 1: SK1000 Sine Wave Inverter

7/23/2019 SK1000 Sine Wave Inverter

http://slidepdf.com/reader/full/sk1000-sine-wave-inverter 1/2

1000W Pure Sine Wave Inverters SK 

FEATURES

True sine wave output (THD < 3%)

Power ON-OFF remote control

Input & output fully isolation

Load control cooling fan

 Advanced microprocessor 

Output frequency 50/60 Hz switch selectable

Low power saving mode to conserve energy

Input polarity reverse / under voltage / over voltage protections

Output short circuit / overload / over temperature protections

Tri-color indicators display input, output level & failure status

e-13 / CE / FCC approved

North America (GFCI)NEMA 5-15R   Schuko

Australia

New Zealand   United KingdomUniversal

OUTPUT

INPUT

AC VOLTAGERATED POWER

SURGE POWER

WAVEFORM

FREQUENCY

AC REGULATION

STANDARD RECEPTACLES

LED INDICATOR

NO LOAD CURRENT DRAW

VOLTAGE RAN GE

EFFICIENCY(Typ.)

FUSE

REMOTE CONTROL UNIT

100 / 110 / 120VAC1000W

2000W

True sine wave (THD < 3%)

50 / 60 Hz selectable by DIP switch

NEMA5-15R / GFCI

Input voltage level, output load level and fault status

CR6 / CR8 optional

SK1000-112   SK1000-124   SK1000-148   SK1000-212

220 / 230 / 240 VAC

Schuko / UK / Australia / Universal

0.38A

12VDC

1.20A   0.60A

10.5~15.0VDC

POWER FACTORALLOWED   COS -90  O ~ COS +90

  O

MODEL No.   SK1000-224   SK1000-248

1.43A   0.75A 0.28A

DC VOLTAGE

STAND-BY CURRENT DRAW   0.25A   0.15A   0.09A   0.08A0.15A0.25A

24VDC   48VDC   12VDC   24VDC 48VDC

21.0~30.0VDC   4 2. 0~ 60 VD C 1 0. 5~ 15 .0 VD C 2 1. 0~ 30 .0 VD C 4 2. 0~ 60 VD C

92.0%89.0%   93.0% 91.0%   94.0%93.0%

20A x 240A x 4   20A x 4

PROTECTION

ENVIRONMENT

SAFETY& EMC

OTHERS

BAT. LOW SHUTDO WN

OVER LOAD

OVER VO LTAGE

OVER TEMPERATURE

OUTPUT SHORT

BAT. POLARI TY

WORKING TEMP.

WORKING HUMIDITY

STORAGE TEMP. HUMIDITY

SAFETYSTANDARDS

ISOLATION RESISTANCE

EMI CONDUCTION & RADIATION

EMS IMMUNITY

LVD

e-MARK

DIMENSION

PACKING

COOLING

APPLICATION

10.5VDC

Shut off output voltage, re-power on to recover 

15.3VDC

Shut off output voltage, recovers automatically after temperature goes down

Shut off output voltage, re-power on to recover 

By fuse open

0 ~ +40 C

20% ~ 90% RH non-condensing

- 30 C ~ + 70 / C - 2 2 F ~ + 1 58 F / 1 0 ~9 5 %

Meet UL458

I/P ~ O/P: 100M Ohms / 500VDC

Compliance to FCC classA

-----

-----

-----

383 x 182 x 88mm (L x W x H)

4.0kgs; 4sets / 20kgs / CARTON

Home and Office applianc es, Power tools and Portable equi pments, Vehicle, Yacht and Solar power systems …etc.

30.6VDC

-----

Compliance to EN55022 class A

Compliance to EN61000-3 -2, 3

Compliance to EN60950-1

Compliance to e-13 * 72/245/EEC, 95/54/EC

BAT. LOWALA RM   11VDC 22VDC 44VDC   11VDC 22VDC 44VDC

21.0VDC 42.0VDC 10.5VDC 21.0VDC 42.0VDC

Loading controlled cooling fan

61.2VDC   15.3VDC   30.6VDC 61.2VDC

  %3

20A x 240A x 4   20A x 4

e13

Page 2: SK1000 Sine Wave Inverter

7/23/2019 SK1000 Sine Wave Inverter