Download - PL12A - Type - C-C1

Transcript
Page 1: PL12A - Type - C-C1

2925

2675

3580

9180

AA 21530

2500

2600

LIVING ROOM

KITCHEN/DINING

W.C

19.9m²

20.3m²

ST0.7sqm

5

1

9003800

5470

1250

2320

UTL/ST2.5m²

1500

10765

HALL

3855

5470

6170

HOUSE TYPE C

HOUSE TYPE C

obscureglazing

AA

BEDROOM 2BEDROOM 3BEDROOM 1

EN-SUITE BATH5

15

11.8m²7.5 m²13.4m²

HP/ST1.1sqm

23601175

4060

3600

2650

1850

3205

LANDING

10765

6170

HOUSE TYPE C

3520

AtticHatch

Folding attic stairs toprovide access to atticstorage area 3.5m2

2925

2675

3580

9180

HOUSE TYPE C

obscureglazing

obscureglazing

2925

2675

3580

9180

HOUSE TYPE C1

obscureglazing

LIVING ROOM

KITCHEN/DINING

W.C

19.9m²

20.3m²

ST0.7sqm

5

1

900 3800

5470

1250

2320

UTL/ST2.5m²

1500

10765

HALL

3855

5470

HOUSE TYPE C1

BEDROOM 2 BEDROOM 3 BEDROOM 1

EN-SUITEBATH5

15

11.8m² 7.5 m² 13.4m²

ST1.8sqm

2360 1175

4060

3600

2650

1850

3205

LANDING

10765

HOUSE TYPE C1

3520

AtticHatch

Folding attic stairs toprovide access to atticstorage area 3.5m2

HOUSE TYPE C1

obscureglazing

obscureglazing

2925

2675

3580

9180

1800

GroundFloor Level+0.000

First Floor Level+2.925

Attic Storage Level+5.600

Ridge Level+9.180

GROUND FLOOR PLANHouse Type C-C156sq.mOA 112sqm - 1205 sq.ft

FIRST FLOOR PLANHouse Type C-C156sq.m

SIDE ELEVATIONHouse Type C

SIDE ELEVATIONHouse Type C1

HALL

SECTION A-A

BEDROOM 3

ATTIC STORAGEmin 9 sq.m

Indicitive Solar Panel or Photovoltiac panels indicated, Final SolarPanel Position Depends on House Orientation.The solar panelsshown are a provisional option to satisfy renewable energyrequirements of building regs part L.Solar panels may be omitted in favour of alternative renewableenergy source.

GroundFloor Level+0.000

First Floor Level+2.925

Attic Storage Level+5.600

Ridge Level+9.180

REAR ELEVATIONHouse Type C-C1

FRONT ELEVATIONHouse Type C-C1

GroundFloor Level+0.000

First Floor Level+2.925

Attic Storage Level+5.600

Ridge Level+9.180

GroundFloor Level+0.000

First Floor Level+2.925

Attic Storage Level+5.600

Ridge Level+9.180

sub

sub

sub

sub

sub

sub

sub

sub

sub

sub

sub

sub

SW/A1

.011

subsub

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

BUS

BUS

BUS

BUS

STOP

STOP

STOP

STOP

STOP

STOP

REVISIONSDATE DESCRIPTION No.NOTES:

DO NOT SCALE FROMDRAWINGS. WORK TOFIGURED DIMENSIONSONLY. ARCHITECT TOBE NOTIFIED OF ALLDISCREPANCIES.

DRAWING TITLE:

PROJECT TITLE: DATE: DRAWN BY:

SCALE: REVISION:

JOB NO: DRAWING NO:M CROSSAN O ROURKE MANNINGc ARCHITECTS

M C

1 Grantham Street, Dublin 8, D08 A49Y, Ireland.Tel: 01-4788700 Fax: 01-4788711 E-Mail: [email protected]

HOUSE TYPE C/C1Plans, Sections & Elevations

Coosan, AthloneA1:100

CLJan'20

18029 PL12

TYPE C/C1 - 3 BED - SEMI-DETACHED

TYP

E C

/C1

- 3 B

ED

- S

EM

I-DE

TAC

HE

D

HOUSE TYPES2 STOREY

C/C1

BED 3

SEMI-DETACHEDSQM /112 SQF1205C/C1

THIS DRAWING TO BE READ IN CONJUNCTION WITH ARCHITECT'S DRAWINGS,CONSULTANT ENGINEER'S DRAWINGS AND SPECIFICATIONS & LANDSCAPEARCHITECTS DRAWINGSREFER TO ARCHITECT'S SITE PLAN PL02 FOR NORTH ORIENTATION.

LEVELS GIVEN ON HOUSE TYPE DRAWINGS ARE GIVEN TO A LOCAL ABSOLUTEZERO LEVEL. FOR SPECIFIC LEVELS DEPENDING ON INDIVIDUAL UNITLOCATION, REFER TO ARCHITECT'S CONTEXT SECTIONS AND ENGINEER'SDRAWINGS WHERE LEVELS ARE ARE ALL GIVEN IN RELATION TO LANDSURVEYOR'S BENCHMARK BASED ON MALIN HEAD DATUM LEVEL.

ROOF : TO BE FINISHED IN SLATE OR CONCRETE ROOF TILES IN SELECTED COLOUR OR SIMILAR APPROVED.

WALLS : SELECTED CLAY BRICKWORK WHERE INDICATED OTHERWISEPAINTED SAND / CEMENT RENDER OR SELF COLOURED RENDER. EXPRESSED BANDS AROUND EXTERNAL OPES/ EXPRESSED LINTOLS OVER EXTERNAL OPES WHERE INDICATED TO BE RECONSTITUTED STONE (LIGHT CREAMLIMESTONE OR GRANITE EFFECT) OR RENDER

JOINERY : ALL WINDOWS AND DOORS, FRAMES AND LEAVES, TO BEALUMINIUM POWDER-COATED TO APPROVED COLOUR OR uPVC. OBSCURE GLAZING WHERE INDICATED TO SENSITIVE WINDOWS.

RAINWATER GOODS : GUTTERS, DOWNPIPES, AND FIXINGS TO BE uPVC OR ALUMINIUM POWDER COATED TO SELECTED COLOUR TO MATCH ROOF SLATES

G E N E R A L N O T E S

N O T E S O N F I N I S H E S :

SOLAR PANELS: INDICATIVE SOLAR PANEL POSITION, FINAL SOLAR PANEL POSITION DEPENDS ON HOUSE ORIENTATION. THE SOLAR PANELS SHOWN ARE A PROVISIONAL OPTION TO SATISFY RENEWABLE ENERGY REQUIREMENTS OF BUILDING REGS PART L. SOLAR PANELS MAY BE OMITTED IN FAVOUR OF ALTERNATIVE RENEWABLE ENERGY SOURCE.

*

N

KEY PLANScale - 1:2500

30-3-20 General update for planning A