PL12A - Type - C-C1
Transcript of PL12A - Type - C-C1
2925
2675
3580
9180
AA 21530
2500
2600
LIVING ROOM
KITCHEN/DINING
W.C
19.9m²
20.3m²
ST0.7sqm
5
1
9003800
5470
1250
2320
UTL/ST2.5m²
1500
10765
HALL
3855
5470
6170
HOUSE TYPE C
HOUSE TYPE C
obscureglazing
AA
BEDROOM 2BEDROOM 3BEDROOM 1
EN-SUITE BATH5
15
11.8m²7.5 m²13.4m²
HP/ST1.1sqm
23601175
4060
3600
2650
1850
3205
LANDING
10765
6170
HOUSE TYPE C
3520
AtticHatch
Folding attic stairs toprovide access to atticstorage area 3.5m2
2925
2675
3580
9180
HOUSE TYPE C
obscureglazing
obscureglazing
2925
2675
3580
9180
HOUSE TYPE C1
obscureglazing
LIVING ROOM
KITCHEN/DINING
W.C
19.9m²
20.3m²
ST0.7sqm
5
1
900 3800
5470
1250
2320
UTL/ST2.5m²
1500
10765
HALL
3855
5470
HOUSE TYPE C1
BEDROOM 2 BEDROOM 3 BEDROOM 1
EN-SUITEBATH5
15
11.8m² 7.5 m² 13.4m²
ST1.8sqm
2360 1175
4060
3600
2650
1850
3205
LANDING
10765
HOUSE TYPE C1
3520
AtticHatch
Folding attic stairs toprovide access to atticstorage area 3.5m2
HOUSE TYPE C1
obscureglazing
obscureglazing
2925
2675
3580
9180
1800
GroundFloor Level+0.000
First Floor Level+2.925
Attic Storage Level+5.600
Ridge Level+9.180
GROUND FLOOR PLANHouse Type C-C156sq.mOA 112sqm - 1205 sq.ft
FIRST FLOOR PLANHouse Type C-C156sq.m
SIDE ELEVATIONHouse Type C
SIDE ELEVATIONHouse Type C1
HALL
SECTION A-A
BEDROOM 3
ATTIC STORAGEmin 9 sq.m
Indicitive Solar Panel or Photovoltiac panels indicated, Final SolarPanel Position Depends on House Orientation.The solar panelsshown are a provisional option to satisfy renewable energyrequirements of building regs part L.Solar panels may be omitted in favour of alternative renewableenergy source.
GroundFloor Level+0.000
First Floor Level+2.925
Attic Storage Level+5.600
Ridge Level+9.180
REAR ELEVATIONHouse Type C-C1
FRONT ELEVATIONHouse Type C-C1
GroundFloor Level+0.000
First Floor Level+2.925
Attic Storage Level+5.600
Ridge Level+9.180
GroundFloor Level+0.000
First Floor Level+2.925
Attic Storage Level+5.600
Ridge Level+9.180
sub
sub
sub
sub
sub
sub
sub
sub
sub
sub
sub
sub
SW/A1
.011
subsub
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
BUS
BUS
BUS
BUS
STOP
STOP
STOP
STOP
STOP
STOP
REVISIONSDATE DESCRIPTION No.NOTES:
DO NOT SCALE FROMDRAWINGS. WORK TOFIGURED DIMENSIONSONLY. ARCHITECT TOBE NOTIFIED OF ALLDISCREPANCIES.
DRAWING TITLE:
PROJECT TITLE: DATE: DRAWN BY:
SCALE: REVISION:
JOB NO: DRAWING NO:M CROSSAN O ROURKE MANNINGc ARCHITECTS
M C
1 Grantham Street, Dublin 8, D08 A49Y, Ireland.Tel: 01-4788700 Fax: 01-4788711 E-Mail: [email protected]
HOUSE TYPE C/C1Plans, Sections & Elevations
Coosan, AthloneA1:100
CLJan'20
18029 PL12
TYPE C/C1 - 3 BED - SEMI-DETACHED
TYP
E C
/C1
- 3 B
ED
- S
EM
I-DE
TAC
HE
D
HOUSE TYPES2 STOREY
C/C1
BED 3
SEMI-DETACHEDSQM /112 SQF1205C/C1
THIS DRAWING TO BE READ IN CONJUNCTION WITH ARCHITECT'S DRAWINGS,CONSULTANT ENGINEER'S DRAWINGS AND SPECIFICATIONS & LANDSCAPEARCHITECTS DRAWINGSREFER TO ARCHITECT'S SITE PLAN PL02 FOR NORTH ORIENTATION.
LEVELS GIVEN ON HOUSE TYPE DRAWINGS ARE GIVEN TO A LOCAL ABSOLUTEZERO LEVEL. FOR SPECIFIC LEVELS DEPENDING ON INDIVIDUAL UNITLOCATION, REFER TO ARCHITECT'S CONTEXT SECTIONS AND ENGINEER'SDRAWINGS WHERE LEVELS ARE ARE ALL GIVEN IN RELATION TO LANDSURVEYOR'S BENCHMARK BASED ON MALIN HEAD DATUM LEVEL.
ROOF : TO BE FINISHED IN SLATE OR CONCRETE ROOF TILES IN SELECTED COLOUR OR SIMILAR APPROVED.
WALLS : SELECTED CLAY BRICKWORK WHERE INDICATED OTHERWISEPAINTED SAND / CEMENT RENDER OR SELF COLOURED RENDER. EXPRESSED BANDS AROUND EXTERNAL OPES/ EXPRESSED LINTOLS OVER EXTERNAL OPES WHERE INDICATED TO BE RECONSTITUTED STONE (LIGHT CREAMLIMESTONE OR GRANITE EFFECT) OR RENDER
JOINERY : ALL WINDOWS AND DOORS, FRAMES AND LEAVES, TO BEALUMINIUM POWDER-COATED TO APPROVED COLOUR OR uPVC. OBSCURE GLAZING WHERE INDICATED TO SENSITIVE WINDOWS.
RAINWATER GOODS : GUTTERS, DOWNPIPES, AND FIXINGS TO BE uPVC OR ALUMINIUM POWDER COATED TO SELECTED COLOUR TO MATCH ROOF SLATES
G E N E R A L N O T E S
N O T E S O N F I N I S H E S :
SOLAR PANELS: INDICATIVE SOLAR PANEL POSITION, FINAL SOLAR PANEL POSITION DEPENDS ON HOUSE ORIENTATION. THE SOLAR PANELS SHOWN ARE A PROVISIONAL OPTION TO SATISFY RENEWABLE ENERGY REQUIREMENTS OF BUILDING REGS PART L. SOLAR PANELS MAY BE OMITTED IN FAVOUR OF ALTERNATIVE RENEWABLE ENERGY SOURCE.
*
N
KEY PLANScale - 1:2500
30-3-20 General update for planning A