Payload: Instrument Control Unit
IL CONTRIBUTO ITALIANO ALLA MISSIONE PLATOPalermo 2-3 Maggio 2011
Rosario [email protected]
ICUR. Cosentino (FGG)
Subsystem EngineeringE. Pace (Uni. Firenze)
ICU HardwareM. Focardi (Uni Firenze)
Subsystem Management
R. Cosentino (INAFFGG)
ICU SoftwareS. Pezzuto (INAFIFSI)
Electronics
Housing
Interface
Data Compression
Application Software
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
Overview
S/C SVM
Memory Unit
Memory and IO Unit
Processor Unit
SpW interface to SVM
Power Supply Unit
ICU
MEUs(4 NDPU)
AEUs FAEU
FDPUs
● 4 MEU (the 16 normal DPU are gathered in 4 group of 4 DPUs)● 2 Fast DPU● 4 Ancillary Electronic Unit● 1 Fast Ancillary Electronic Unit● 1 MEU-PSU
Each unit include 2 router (main and redundant)
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
Overview
S/C SVM
Memory Unit
Memory and IO Unit
Processor Unit
SpW interface to SVM
Power Supply Unit
ICU
MEUs(4 NDPU)
AEUs FAEU
FDPUs
● Handle the communications with spacecraft● Receive and process telecommands for the ICU: the received commands shall be validated prior to their execution● Format and transmit cyclic and sporadic HK telemetry (HKTM)● Format and trasmit the scientific payload telemetry packets (PLTM)● Manage the SpaceWire network• Receive the onboard time (Central Time Reference) from the S/C, handle the time stamping of the data transmitted in HKTM and forward the CTR to the DPUs.• Produce state and diagnosis information (cyclic status, progress event).• receive the spacecraft time code from the S/C and forward it to the DPUs• Schedule the DPU tasks (by the way of commands sent to the DPUs)• Manage the data flow • Manage the mode transitions• Manage the Software parameters• Manage the maintenance of the ICU software• Manage the maintenance of the DPU software• Compress the data using a lossless compression algorithm. A compression factor of at least 2 is required.• Acquire and transmit to the S/C its own voltage and current consumption
Functional characteristics (observation and configuration mode)
Network architecture and management (SpaceWire) Data volume and TM budget Hardware architecture ICU: new design PROCESSOR Module MEM & I/O Board MOTHERBOARD ICU mechanical assembly ICU Budget (mass and power) SW structure Model philosophy Objective of the definition phase ICU Development Plan
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
receive the flux, the centroids and the imagettes (F-DPU: every 2.5 s ; N-DPU: every 25 s);
compress the imagettes: a compression factor 2 and 3 is guaranteed;
detect outliers (flux and centroid) by comparing the data corresponding to the same star and coming from N-groups telescopes (N=8 or N=16 or N=32);
stack the valid flux and centroids; compute the mean and the std dev of the stacked
measurements at a cadence depending of the sample category (50 sec. or 600 sec): F-DPU: K ≤ 20; N-DPU: K ≤ 2 (50 s) or K ≤ 24 (600 s);
bufferize and compress photometric and centroid data: a factor of ~ 2 is guaranteed;
format and transmit to the SVM the scientific packets (PLTM).
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
Send the star catalogue and other configuration parameters to DPU Cross check between data from telescopes of the same LoS (verify the consistency of the list and positions of all the stars). Schedule the DPU tasks Compress full-frames images from DPUs Packetization and trasmission to SVM of all the data sent by DPU which allow to valid on-ground operation:
Far field’ full images List of background window position and background intensities Parameters for candidate and reference stars List and position of reference stars Distortion matrix Selected parameters of all the targets (position, mask, …)
No storage of data (only temporary buffering) periodically or loss of the Los
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
The active ICU is responsible for managing the SpaceWire network: ICU is a remote network manager.
The active ICU configures the routers (routing table, link speed, etc.): the logical addressing will be used (no path addressing).
The active ICU manages (configures / monitors/ controls) its own routers and the MEU routers.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
32 normal telescopes + 2 fast telescope 4 detectors each telescope (4510X4510 CCDs) Data volume = 212 Gb/day (imagettes, photometric data,
centroid data, raw images) Presently the TM rate is 106 Gb/day ICU shall compress data by a factor 2 at least
ICU shall manage an input datarate from NDPU and FDPU of about 12 Mbps and an output datarate to the SVM of about 1.5 Mbps. These data rates can be easily managed by the standard SpW link, running up to 100 Mbps.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
Constraint: o Storing large amount of data (to achieve a compression
factor of 2)o Handle a large number of SpW links
Proposed Hardware characteristics:o a routing unit for an efficient management of the SpW
network and a wide internetworking capabilities, implementing two or three routers
o a processor unit (i.e. a motherboard with power processing capabilities)
o a memory unit for data storage and buffering with one or more SpW links to manage and configure them
o a power supply unit with redundancy.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
ICU box ICU box EIDBEIDB constraints constraints:
Volume: 250 x 240 x 220 mm3,
Mass: 6.8 Kg
3 “stacked” Units:
Processor Unit
Memory & I/O Board
Power Supply Unit
Back panel (or mother board) for signals routing and crossstrapping
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
11 SpW links
2 PSU (M + R);
2 discrete command lines and a main power line (28V) from SVM to ICUPSU A/B.
R 1 _ A
R 2 _ A
W R _ C tr lF P G A
A
R D _ C tr lF P G A
A
M E M _ C tr lF P G A
A
8 G b it S D R A M( 2 5 6 M x 3 2 )
[( 4 + 2 ) x 2 G b i t C u b e s ]
A T 7 9 1 0
A T 7 9 1 0
M E M & I O B o a r d A
R 1 _ B
R 2 _ B
W R _ C tr lF P G A
B
R D _ C tr lF P G A
B
M E M _ C tr lF P G A
B
A T 7 9 1 0
A T 7 9 1 0M E M & I O B o a r d B
R 4 _ A
IN _ 1 _ A
IN _ 5 _ AIN _ 4 _ AIN _ 3 _ AIN _ 2 _ A
IN _ 1 1 _ AIN _ 1 0 _ A
IN _ 6 _ A
IN _ 9 _ A
IN _ 7 _ AIN _ 8 _ A
IN _ 1 _ B
IN _ 5 _ BIN _ 4 _ BIN _ 3 _ BIN _ 2 _ B
IN _ 1 1 _ BIN _ 1 0 _ B
IN _ 6 _ B
IN _ 9 _ B
IN _ 7 _ BIN _ 8 _ B
C & C a n d T C & T M F P G A
A
A T 7 9 1 0
L E O N 2C P U _ AA T 6 9 7 F
B o o t P R O M1 2 8 K B y t e
( 4 x 3 2 K x 8 )
S R A M8 M B y t e + E d a c
( 5 x 2 M x 8 c u b e s )
N O R F la s h E E P R O M6 4 M B y te
( 2 x 1 6 M x 1 6 c u b e s )
8 M B y te x I C U8 M B y te x D P U s3 2 M B yt e x S t a r C a t a l o g u e1 6 M B yt e S p a r e
R 4 _ B
C & C a n d T C & T MF P G A
B
A T 7 9 1 0
L E O N 2C P U _ BA T 6 9 7 FB o o t P R O M
1 2 8 K B y t e( 4 x 3 2 K x 8 )
S R A M8 M B y t e + E d a c
( 5 x 2 M x 8 c u b e s )
N O R F la s h E E P R O M6 4 M B y te
( 2 x 1 6 M x 1 6 c u b e s )
8 M B y te x I C U8 M B y te x D P U s3 2 M B yt e x S t a r C a t a l o g u e1 6 M B yt e S p a r e
P r o c e s s o r B o a r d A
P r o c e s s o r B o a r d B
P r o c e s s o r S u p p l yB o a r d A
C & C _ A _ N C & C _ A _ RE G S E
C & C _ A _ N C & C _ A _ RE G S E
O n / O f fH P C
2 8 VP r im a r y P o w e r
B u s
P r o c e s s o r S u p p l yB o a r d B
O n / O f fH P C
2 8 VP r im a r y P o w e r
B u s
S e c o n d a r y V o lt a g e s B
S e c o n d a r y V o lt a g e s A
AD
C
MU
X
Con
ditio
ning
M o n it o r i n g
AD
C
MU
X
Con
ditio
ning
M o n it o r i n g
P L A T O I C U
S p WI / F
8 G b i t S D R A M( 2 5 6 M x 3 2 )
[( 4 + 2 ) x 2 G b i t C u b e s ]
S p WI / F
S p WI / F
S p WI / F
Contribution from Thales Alenia
Space Italy:
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
The Processor Module board is built around a LEON 2 (AT697F) radiation tolerant single chip microprocessor based on SPARC V8 architecture.
Microprocessor includes on chip an Integer Unit (IU), a Floating Point Unit (FPU), a Memory Controller and a DMA Arbiter.
Fault tolerance is supported using parity on internal/external buses and EDAC on the external data bus.
Several Processor Modules could be implemented for a homogeneous or heterogeneous multiprocessor systems with multitasking capabilities thanks to RTEMS OS, in order to appropriately process and compress digital data.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
128 KByte Boot PROM is provided for the bootstrap & initialization SW.
64 MByte NOR Flash (2X16Mx16 cubes) is provided to store on board the ICU and NDPU Application SW and star catalogue. The memory can be fully patched and dumped during flight by means of telecommands.
8 MByte SRAM (2Mx32 with EDAC) is provided for Application SW execution.
Both FLASH and SRAM are protected by the processor EDAC correcting any single bit error and signaling any double bit error detected.
FLASH memory can be switched off when not accessed for long time in order to improve their data retention performance and to minimise consumption. The FLASH On/Off switch is commanded through a GPIO line of the Processor.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
The Processor Module host a 8x SpaceWire Router ASIC (ATMEL AT7910E) as baseline.Up to 4 SpW links are accessible from outside whilst the remaining 4 SpW links are used for connection and cross strapping with other modules internal to the unit.
The SpW Router ASIC acts also as network terminal node thanks to the two 8 bit wide parallel ports it provides.
4 external SpW links could be used for both Command & Control purposes and/or for transfer of low/medium data rate packets from/to SpW sources (e.g. the satellite central onboard computer). A SpW link is foreseen for EGSE pourposes.
The Router interfaces an ACTEL RTAX2000S FPGA responsible for communication and control procedures, for clock division and distribution and for OnBoard reference Time production and syncronization (by means of Timecode SpW packets from OBC).
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
The Memory Module (MM) is based on SDRAM memories and it can be powered on/off and controlled by the Supervisor module (M or R). Req’s are 8Gb. It consists of three main blocks:
⇒ Power Distribution and On/Off circuitry; ⇒ The Memory Controller FPGA (ACTEL RTAX2000S); ⇒ The SDRAM Memory Array;
The Processor Module handles all the digital I/Fs of the MM and all the operations on the memory array: initialisation, writing, reading, refresh, scrubbing and the local redundancy management.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
The I/O module consist of the following blocks:
⇒2 SpW routers in charge of the SpW I/F with the PLATO DPS, Nom/Red Supervisor module and with the SpW router to the SVM;⇒The Input WRC FPGA and the Output RDC FPGA in charge of managing data packets writing on or reading from the MM;⇒Power Distribution and On/Off circuitry;
The SpW router ASIC receives SpW packets from PLATO DPS via 6+5 SpW links and routes them via its two parallel output ports to the WRC FPGA, which stores them into the Memory Array throungh the MEMC FPGA.
The RDC FPGA retrieves TM packets allocated inside the Memory Array, formats and forward them to the SpW I/F included in the RDC FPGA.
The operations of the SpW routers on the I/O Module can be configured, controlled, monitored by the operational Processor Module via SpW I/F (e.g. routing table programming for logical addressing, speed selection…etc).
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
The Motherboard is the mean through which the Nominal and Redundant Daughterboards are connected and exchange the power and signal lines each other.
Thanks to the use of a motherboard PCB there are no wire connections inside the unit.
All the I/O connectors are directly mounted on the relevant PCB modules.
The Motherboard is equipped with straight connectors and lies on the ICU bottom panel while the Daughterboards are inserted through the top of the unit and plug into the Motherboard through rightangle connectors.
All the Modules are implemented on “extended” double Eurocard PCBs (200 mm x 233 mm).
Mass 300 g.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
The ICU is composed by N nominal + N redundant daughterboard modules perpendicularly plugged onto a motherboard that lays on the unit bottom.
The motherboard is fixed by screws to the unit bottom plate.
Each daughterboard is provided with motherboard connectors on one of the 233mm side and with the external I/O connectors on the opposite side.
The daughterboards are stiffened by a mechanical frame on which the external I/O connector are fixed and that are screwed to the unit upper panels.
The lateral sides of the modules are equipped with cardlock retainers that are used to fix the boards to the unit lateral panels.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
apr11 Mass [g] n. Brd T. Mass [g] Box 1700 1 1700
Power Supply Module 1100 2 2200
Processor Module 550 2 1100
Memory & I/O Module 600 2 1200
Motherboard 300 1 300
Tot. 6500
mar11 Mass [g] n. Brd T. Mass [g] Box 2000 1 2000Power Supply Module 1150 2 2300Processor Module 600 2 1200TC/TM 700 2 1400I/O module 500 2 100064 Gbit 350 2 700motherboard 250 1 250
Tot. 8850
2350 g less
February 2011
April 2011
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
Dimensions
The dimension of a (manufactured) unit composed of:
• 2 Power Supply modules (1N+1R)• 2 Processor modules (1N+1R)• 2 Memory & Input/Output modules (1N+1R)
are:
⇒ 260 x 250 x 251 mm [L x W x H] not considering the mounting feet ⇒ 260 x 278 x 251 mm [L x W x H] including the mounting feet
In March the dimension was:
⇒ 340 x 253 x 251 mm [L x W x H] not considering the mounting feet ⇒ 340 x 278 x 251 mm [L x W x H] including the mounting feet
This data is NOT fully compliant but very close to the PLATO ICU dimensions reported in the EIDB document and in the URD (220 mm x 250 mm x 240 mm).
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
The ICU (Main + Redundant) overall power budgeis 19.8 W x 2 maximum
Max power consumption [W] global mass [g]
Power Supply Module 2.9W 85% min efficiency
Processor Module 6.1W
I/O & Memory Module 10.8W 8Gbit
Motherboard
total max primary power consumption 19.8W
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
There are 4 kinds of SW available to the ICU: Bootstrap SW (BSW) Operating system (OS) Drivers Application SW (ASW)
BSW and drivers provided by the ICU HW manufacturer;
OS depends on the adopted microprocessor; real time OS commercially available, like RTEMS.
Drivers will be developed such that they will be integrated in the OS.
The ASW is under responsibility of IFSI-INAF. The code shall be written in C; some module may
be required to be written in Assembly.
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
PLATO Payload development is based on tests on Qualification Models (QM) Acceptance tests on a Flight models (FM).
Models sequentially built and tested: Breadboards or EBBs see later (industrial plan) Structural and Thermal Model (STM) Engineering Models (EM) (2 models) Qualification Model (QM) Flight Model (FM) Spare Model
Il contributo italiano alla missione PLATO -Palermo 2-3 Maggio 2011
ICU architecture Detailed architecture Software design
▪ Software Requirement Specification ▪ Software Interface Control Document ▪ Interface document
Docs Draft at the DPS meeting on January 2011 Final release on April 2011 October 2011 selection December 2011 PDR
EM partially completed, delivered temporally to ESA and returned to industry at the completion of the test. The test procedures had to be defined and communicated to ICUTEAM as soon as possible.
Jun. ‘12∗Apr. ‘12ICU Bread Boarding
Structural & Thermal ModelJun. ‘13Apr. ’13ICU STM MAIT
Mar. ‘12∗Jan. ‘12Electrical, Mechanical and Software Detailed Design
T0 + 3 02 Jan. ‘12Preliminary Design Review (PDR)
P
Detailed Design Documentation & AnalysisDec. ‘11Oct. ‘11ICU Detailed Design
T0 01 Oct. ‘11ICU Implementation Phase KickOff
Specification Freezing Architecture Detailed DefinitionApr. ‘11Feb. ‘11ICU Definition Phase
Jan. ‘11Nov. ‘10ICU PreDefinition Phase
remarksEndStartActivities/Milestones
1 board per type (or a set of EEE Parts to manufacture a board per type)
m
Mar. ‘14July ‘13ICU Spare Set
T0 + 30 Apr. ‘14Acceptance Review (AR)
A
1 deliverable unit fully equipped, internally redounded, based on QMLQ EEE parts (t.b.c. according to PA Plan), or higher level in case the reliability goal is not met with QMLQ.
Apr. ‘14July ‘13ICU FM MAIT
T0 + 21 July ‘13Qualification Review (QR)
Q
1 deliverable unit fully equipped, internally redounded, based on extended temperature range EEE parts, same type and same manufacturer of FM, Fit, Form & Function compatible with FM.
June. ‘13Oct ‘12ICU QM MAIT
T0 + 12 Oct. ‘12Critical Design Review (CDR)
C
2 deliverable units, internally not redounded, based on extended temperature range EEE parts, Fit & Form compatible with FM
Dic. ‘12Apr. ‘12ICU EM MAIT
remarksEndStartActivities/Milestones
ICU mechanical assembly
All panels are made of surfacetreated aluminium alloy (Alodine) and externally painted in black (except Bottom panel) to improve radiating exchange with the environment.
The thickness of the panels is designed to cope with the heat dissipation needs; in particular the thickness of the lateral panels increases from top to bottom to facilitate the heat sink.