Manufacturers of Electrical Switchgear
IP41 Sheet Steel Enclosed Products
Pro-Line products are designed to offer high quality, user friendly, practical and cost effective solutions for most indoor applications.
• Fully load rated AC22A 415V.
• BSEN60947-3 Conformity.
• Door interlocked padlockable handles on hinged units.
• Alternative pole configurations and auxiliary contacts available.
• Removable gland plate top & bottom (not on SPN).
Proline Switchfuses O - I
• Alternative configurations, 3 or 4 pole + auxiliary contacts.
• Larger enclosures to suit customers individualrequirements together with IP65, Stainless Steel and GRP.
Load Break Isolators O - I
NominalRating Ie
20A
32A
63A
63A
80A
80A
100A
100A
125A
Poles
TP&N
TP&N
SP&N
TP&N
SP&N
TP&N
SP&N
TP&N
TP&N
Reference
SF20
SF32
SF63SPN
SF63
SF80SPN
SF80
SF100SPN
SF100
SF125
Fuse Type
NSD
NSD
22x58
BAO
22x58
OSD
22x58
OSD
TIS
Cable Connection
6mm
16mm
25mm
M8 lug
25mm
M8 lug
25mm
M8 lug
M8 lug
TerminalWidth
Tunnel
Tunnel
Tunnel
20mm
Tunnel
20mm
Tunnel
20mm
20mm
Style
Hinged Door
Hinged Door
4 screw lid
Hinged Door
4 screw lid
Hinged Door
4 screw lid
Hinged Door
Hinged Door
Enclosure H x W x D
300x180x110
300x180x110
250x115x60
400x230x110
250x115x60
400x230x110
305x135x60
400x230x110
400x230x110
Special
Requirement?
Just Ask!
2
Reference
LB20
LB20G
LB32
LB32G
LB63
LB63G
LB100
LB125
LB160
NominalRating Ie
20A
20A
32A
32A
63A
63A
100A
125A
160A
Poles
TP&N
TP&N
TP&N
TP&N
TP&N
TP&N
TP&N
TP&N
TP&N
Cable Connection
16mm
16mm
16mm
16mm
25mm
25mm
M8 lug
M8 lug
M8 lug
TerminalWidth
Tunnel
Tunnel
Tunnel
Tunnel
Tunnel
Tunnel
20mm
20mm
20mm
Style
Hinged Door
4 screw lid
Hinged Door
4 screw lid
Hinged Door
4 screw lid
Hinged Door
Hinged Door
Hinged Door
Enclosure H x W x D
300x180x110
105x105x60
300x180x110
105x105x60
300x180x110
200x140x115
400x230x110
400x230x110
400x230x110
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
IP55 Sheet Steel Enclosed Double Break Switchfuses
Switchfuse enclosures are selected to provide adequate wiring room for “standard” cables. Larger enclosures to suit customers individual requirements together with IP65, Stainless Steel and GRP enclosures, are also available.
• Fully load rated AC23A 415 to 690V.
• Fitted with general purpose BS88 HRC fuses.
• Double break, fuses isolated on both sides.
• BSEN60947-3 Conformity.
• Door interlocked padlockable handles.
• Removable gland plate top and bottom.
Panel Mounting Double Break Switchfuses
3
Nominal RatingIe 415V
ReferenceTP & N i.e. 3P &
Solid Neutral
ST SWF 6/3+N+F
ST SWF 10/3+N+F
ST SWF 12/3+N+F
ST SWF 16/3+N+F
ST SWF 20/3+N+F
ST SWF 25/3+N+F
ST SWF 30/3+N+F
ST SWF 40/3+N+F
ST SWF 50/3+N+F
ST SWF 63/3+N+F
ST SWF 80/3+N+F
ST SWF 100/3+N+F
ST SWF 125/3+N+F
Reference 4 pole i.e. 3P &
Switched Neutral
ST SWF 6/4+F
ST SWF 10/4+F
ST SWF 12/4+F
ST SWF 16/4+F
ST SWF 20/4+F
ST SWF 25/4+F
ST SWF 30/4+F
ST SWF 40/4+F
ST SWF 50/4+F
ST SWF 63/4+F
ST SWF 80/4+F
ST SWF 100/4+F
ST SWF 125/4+F
Fuse Type
BAO
OSD
CTFP
DD
DD
ED
ED
ED
FF
FF
GF
GH
GH
Cable Connection
M5 lug
M6 lug
M8 lug
M8 lug
M8 lug
M10 lug
M10 lug
M10 lug
M12 lug
M12 lug
M12 lug
M12 lug
M12 lug
TerminalWidth
11mm
14mm
20mm
20mm
20mm
25mm
30mm
30mm
40mm
40mm
40mm
40mm
40mm
Enclosure H x W x D
400x300x200
400x300x200
500x400x200
500x400x200
500x400x200
600x400x250
600x400x250
600x400x250
800x600x300
800x600x300
1000x800x400
1200x800x400
1200x800x400
63A
100A
125A
160A
200A
250A
315A
400A
500A
630A
800A
1000A
1250A
30kW
45kW
55kW
75kW
105kW
132kW
155kW
200kW
355kW
355kW
400kW
500kW
600kW
Panel mounting switches are supplied without fuselinks but complete
with a door interlocking padlockable handle, shaft extension, two
terminal shrouds and phase barriers.
To Order: Remove the ST from the front of the references above and F
from the end. e.g. ST SWF 20/3+N+F becomes SWF 20/3+N.
• Alternative fuse link ratings.
• Spreader terminals and multi cable connection facilities.
• Alternative voltage requirements 1000V AC and DC.
• Auxiliary contacts 1 x N/O, 1 x N/C to retro fit.
• Aluminium, Tufnol or brass gland plates.
• Indicator lamps or additional equipment.
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
IP55 Sheet Steel Enclosed Load Break Isolator
Isolator enclosures are selected to provide adequate wiring room for “standard” cables. Larger enclosures to suit customers individual requirements together with IP65, Stainless Steel and GRP enclosures also available.
• Fully load rated AC23A 415 to 690V.
• BSEN60947-3 Conformity.
• 3+N, 4, 6 and 8 pole.
• Door interlocked padlockable handles.
• Removable gland plate top and bottom.
Panel Mounting Load Break Isolators
4
Nominal Rating Ie 415V
ReferenceTP & N ie 3P &Solid Neutral
ST ISO 2/3+N
ST ISO 3/3+N
ST ISO 6/3+N
ST ISO 10/3+N
ST ISO 12/3+N
ST ISO 16/3+N
ST ISO 20/3+N
ST ISO 25/3+N
ST ISO 30/3+N
ST ISO 40/3+N
ST ISO 50/3+N
ST ISO 63/3+N
ST ISO 80/3+N
ST ISO100/3+N
ST ISO 125/3+N
Reference 4 pole i.e. 3P &
Switched Neutral
ST ISO 2/4
ST ISO 3/4
ST ISO 6/4
ST ISO 10/4
ST ISO 12/4
ST ISO 16/4
ST ISO 20/4
ST ISO 25/4
ST ISO 30/4
ST ISO 40/4
ST ISO 50/4
ST ISO 63/4
ST ISO 80/4
ST ISO 100/4
ST ISO 125/4
Cable Connection
6mm
16mm
35mm
M6 lug
M6 lug
M8 lug
M8 lug
M10 lug
M10 lug
M10 lug
M12 lug
M12 lug
M12 lug
M12 lug
M12 lug
TerminalWidth
Tunnel
Tunnel
Tunnel
14mm
14mm
20mm
20mm
25mm
30mm
30mm
40mm
40mm
40mm
40mm
40mm
Enclosure H x W x D
200x200x120
200x200x120
200x200x120
400x300x200
400x300x200
500x400x200
500x400x200
700x500x250
700x500x250
700x500x250
800x600x300
800x600x300
1000x800x300
1200x800x300
1200x800x300
20A
32A
63A
100A
125A
160A
200A
250A
315A
400A
500A
630A
800A
1000A
1250A
9.5kW
11.5kW
22kW
45kW
55kW
75kW
105kW
132kW
155kW
200kW
355kW
355kW
400kW
500kW
on app
Panel mounting isolators are supplied complete with a door interlocking
padlockable handle, shaft extension and two terminal shrouds.
To Order: remove the ST from the front of the references above.
e.g. ST ISO 20/3+N becomes ISO 20/3+N.
• Spreader terminals and Multi cable connection facilities.
• Alternative voltage requirements 1000V AC and DC.
• Auxiliary contacts 1 x N/O, 1 x N/C to retro fit.
• Aluminium, Tufnol or brass gland plates.
• Indicator lamps or additional equipment.
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
IP41 Sheet Steel Busbar Chambers
Busbar chambers are designed to compliment our extensive range of switchfuses and load break isolators with connection kits to suit for ease of installation. The four fully rated pole system is modular in construction to give varing busbar widths. At 380mm high and 250mm deep the enclosure provides ample room to accomodate large cables and fascilitate installation with all side panels easily removable.
• 4 fully rated poles up to 800A.
• Twin copper bar design for convenient clamping.
• Fully compliant with BSEN 60439-1.
• All side panels removable.
Busbar Connection Clamps and Incoming Kits
• Additional empty enclosures for cable spreading.
• Busbar frames mounted in alternative enclosures IP65, Stainless Steel or GRP.
5
Nominal Rating Ie 415
200A
400A
630A
800A
600mm
BB20/6
BB40/6
BB63/6
BB80/6
900mm
BB20/9
BB40/9
BB63/9
BB80/9
1200mm
BB20/12
BB40/12
BB63/12
BB80/12
1500mm
BB20/15
BB40/15
BB63/15
BB80/15
1800mm
BB20/18
BB40/18
BB63/18
BB80/18
2100mm
BB20/21
BB40/21
BB63/21
BB80/21
Ordering Reference all 4 poleAll busbar chambers are 380 mm high by 210 mm deep by:
References200A | Above
BCE50
BCE/95
BCT1 BCT4
BCT2 BCT5
BCT3
BCSS/1F32
BCSS/2F40
Connection Clamps
Direct cable clamps
For cables 10mm2 to 50mm2
For cables 50mm2 to 95mm2
Cable lug connection
Max lug 50mm2 x 6mm dia
Max lug 75mm2 or 2x50mm2 x 8mm dia
Max lug 240mm2 x 12mm dia
Flexibar Clamps
Max bar width 32mm
Max bar width 40mm
Max Load
160A
200A
160A
250A
800A
630A
800A
A
200
400
630
800
Disconnector Kitreferences
BCCKD/20
BCCKD/40
BCCKD/63
BCCKD/80
Switchfuse Kitreferences
BCCKSF/20
BCCKSF/40
BCCKSF/63
Flexibar Incomer Connection Kits
All kits include appropriate clamps
Kits are designedto be used withSwitchgear Systemsstandard disconnectorsand switchfuses.
If you require a kit for analternative incomer please specify.
BCE/50
BCT1
BCT2
BCT3
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
IP55 Sheet Steel Enclosed Changeover Switches I-O-II
Changeover switch enclosures are selected to provide adequate wiring room for “standard” cables. Larger enclosures to suit customers individual requirements together with IP65, Stainless Steel and GRP enclosures also available.
• Fully load rated AC22A 415 to 690V.
• BSEN60947-3 conformity.
• Complete changeover switching system in.one unit, no bridging bars required.
• Compact design saving up to 60% panel room.
• Door interlocked padlockable handle.
• 5 pin appliance inlets up to 125A.
• Spreader terminals and multi cable connection facilities.
• Auxiliary contacts to retro fit.
• Aluminium, Tufnol or brass gland plates.
• Indicator lamps or additional equipment.
Panel Mounting Changeover Switches
6
Panel mounting switches are supplied complete with a door interlocking
padlockable handle, shaft extension and terminal shrouds.
To order: remove the ST from the front of the references above.
e.g. ST CHO 20/4 becomes CHO 20/4.
Reference 4 pole for TP&N supplies
ST CHO 6/4
ST CHO 10/4
ST CHO 12/4
ST CHO 16/4
ST CHO 20/4
ST CHO 25/4
ST CHO 30/4
ST CHO 40/4
ST CHO 50/4
ST CHO 63/4
ST CHO 80/4
ST CHO 100/4
ST CHO 125/4
Cable Connection
M6 lug
M6 lug
M6 lug
M8 lug
M8 lug
M10 lug
M10 lug
M10 lug
M10 lug
M10 lug
M12 lug
M12 lug
M12 lug
Enclosure H x W x D
500x400x200
500x400x200
500x400x200
500x400x200
600x400x250
700x500x250
700x500x250
800x600x250
800x600x250
1000x600x250
1000x600x300
1200x800x300
1200x800x300
TerminalWidth
15mm
15mm
15mm
20mm
20mm
25mm
30mm
30mm
35mm
35mm
40mm
40mm
40mm
NominalRating Ie
63A
100A
125A
160A
200A
250A
315A
400A
500A
630A
800A
1000A
1250A
IMPORTANT NOTE: Changeover switch should be selected to match the current taken by the load being supplied. In the absence of this information select based on the higher current of the supplies. If using a generator it is unreliable to use its KVA rating to calculate changeover switch size.
Switchgear Systems changeover switches are a one piece construction with three sets of contacts driven from a single shaft.
This makes them ideal for selecting between two supplies to a common output.
or
For use where there is a single supply to be used on eitherof two outputs.
1-2 Transfer switches with no OFF position are available on request.
Secondary Supply
Primary Supply
Common
Secondary Load
Primary Load
Common In
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
IP55 Sheet Steel Enclosed Bypass Switches I-O-II
Bypass switch enclosures are selected to provide adequate wiring room for “standard” cables. Larger enclosures to suit customers individual requirements together with IP65, Stainless Steel and GRP enclosures also available.
• Fully load rated AC22A 415 to 690V.
• BSEN60947-3 conformity.
• Vertical or horizontal designs to suit cabling arrangment.
• Door interlocked padlockable handle.
Layered Bypass Switches
• Spreader terminals and multi cable connection facilities.
• Over current protection devices.
• Aluminium, Tufnol or brass gland plates.7
Horizontal Bypass SwitchesReference 4 pole
ST CHO BY1 6/4
ST CHO BY1 10/4
ST CHO BY1 12/4
ST CHO BY1 16/4
ST CHO BY1 20/4
ST CHO BY1 25/4
ST CHO BY1 30/4
ST CHO BY1 40/4
Cable Connection
M6 lug
M6 lug
M6 lug
M8 lug
M10 lug
M10 lug
M10 lug
M10 lug
Enclosure H x W x D
700x500x200
700x500x200
700x500x200
700x500x200
800x600x250
800x600x250
1000x800x300
1000x800x300
TerminalWidth
15mm
15mm
15mm
20mm
25mm
25mm
30mm
30mm
NominalRating Ie
63A
100A
125A
160A
200A
250A
315A
400A
Reference 4 pole
ST BYCP 25/4
ST BYCP 30/4
ST BYCP 40/4
ST BYCP 50/4
ST BYCP 63/4
ST BYCP 80/4
ST BYCP 100/4
ST BYCP 125/4
Cable Connection
M10 lug
M10 lug
M10 lug
M12 lug
M12 lug
M12 lug
M12 lug
M12 lug
Enclosure H x W x D
800x600x400
1000x600x400
1000x600x400
1400x800x500
1400x800x500
1600x800x600
1600x800x600
1600x800x600
TerminalWidth
25mm
25mm
25mm
30mm
30mm
30mm
40mm
40mm
NominalRating Ie
250A
315A
400A
500A
630A
800A
1000A
1250A
Horizontal bypass switches are designed to easily facilitate all cables from one direction with linking on the other side.
500A and above are in floor standing cabinets with 100mm plinth
800A and above have multi cable connection facilities
Panel Mounting Bypass Switches
Panel mounting switches are supplied complete with a door interlocking padlockable handle, shaft extension and terminal shrouds.
To order: remove the ST from the front of the references above.e.g. ST BY1 10/4 becomes BY1 10/4.
Layered bypass switches are designed to minimize panel width and keep each set of cables separate. As standard they facilitate bypass cabling from one direction and equipment cabling from the other. However a variety of cable directions can be catered for. This layout of switch ideal for larger current ratings.
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
Additional Features
8
IP55 Sheet Steel Enclosed Automatic Transfer Systems
The growing demand for standby power in industrial, commercial and domestic environments has created a need for a flexible solution to Automatic Transfer Switching. The Switchgear Systems Ltd ATS panels listed here provide the standard building blocks from which we can customise an automatic transfer solution to suit your needs.
Mains to Mains ATS PanelsM2M ATS panels are designed for applications where there are two permanently available power supplies or a supply taking two differing routes in a building for emergency backup.
These panels feature:
• A control relay monitoring total power failure, phase failure andvoltage variation of the primary supply 415V (adjustable ± 5 to ± 20 %).
• LED indication on the relay to aid set up.
• AC1 rated mechanically and electrically interlocked contactors.
• External LED status indication of supply healthy.
Panel operation:
• Upon total power or phase failure of the primary supply,changeover is immediate with a 3 second return delay.
• Upon phase failure and voltage variation of the primary supply, there is a delay timerto avoid nuisance tripping (adjustable 0.1 to 10 seconds) with a pre set 3 minute monitoring period before return.
NominalRating Ie
40A
63A
80A
100A
125A
160A
200A
250A
Cable Connection
25mm cage
25mm cage
25mm cage
35mm cage
70mm cage
M10 lug
M10 lug
M12 lug
Reference 2 Pole for
single phase
ATS 4/2 M2M
ATS 6/2 M2M
ATS 8/2 M2M
ATS 10/2 M2M
ATS 12/2 M2M
ATS 16/2 M2M
Enclosure H x W x D
500x400x200
500x400x200
600x400x200
600x400x200
600x400x200
800x600x300
Reference 4 Pole for
three phase
ATS 4/4 M2M
ATS 6/4 M2M
ATS 8/4 M2M
ATS 10/4 M2M
ATS 12/4 M2M
ATS 16/4 M2M
ATS 20/4 M2M
ATS 25/4 M2M
Enclosure H x W x D
600x400x200
600x400x200
700x500x200
700x500x200
800x600x250
1000x600x300
1000x600x300
1200x800x300
Reference suffix abovei.e. ATS 4/4 M2M/PNT
/ISO
/PNT1
/TM01
/SUIND
/FF
Description
ISOLATION - If not available adjacent to the installation, door interlocked padlockable isolation of incoming supplies can be incorporated into M2M and M2G DS705 panels.
2 x Pneumatic changeover delay timers i.e. both supplies will be OFF (adjustable 0-30 sec)
Digital return to primary supply timer (0.1 sec –10hr)
2 x external LED status indication of supply in use
NOTE: FOR DESIGNATED FIRE FIGHTING LIFTS /PNT1 AND /SUIND ARE NEEDED
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Mains to Generator ATS Panels
M2G DS705 ATS panels are designed for applications where the primary mains supply is backed up by a standby generator. The panel supplies a “Generator Start Signal” which is connected through the negative of the generator remote start input.
9
*Note: All panels need a continuous DC supply to power the processor. This is normally taken from the generator battery, hence the control voltage has been selected to match the normal battery voltage. Other voltages can be catered for and alternative built in or stand alone maintainable power sources can be supplied.
These panels feature:
• AC1 rated mechanically and electrically interlocked contactors.
• Micro processor based configurable graphic interface providing:
- Auto, Manual OFF load and Manual ON load modes. - Adjustable under voltage limits for mains fail and return. - Configurable mains fail and return timers. - Adjustable generator warm up and cool down timers. - External LED status indication of supply healthy and in use. - Generator start signal. - Front of panel set up.
• Generator start signal connection.
• Remote generator start signal terminals.
• Remote close down terminals.
Panel operation:
• Auto Mode – Upon detection of mains failure the unit sends a start request to the generator control unit. Once the generator output is within limits the load will be switched to the generator. Upon mains return within limits the unit will switch the load to the mains.
• Manual Off Load Mode – This is used to manually start and run the generator off load formaintenance testing.
• Should the mains supply fail in this mode, then the load is transferred to the generator automatically.
• Manual On Load Mode - This mode is used to manually start and run the generator on load.
*Control Voltage
12V DC
12V DC
12V DC
24V DC
24V DC
24V DC
24V DC
24V DC
NominalRating Ie
40A
63A
80A
100A
125A
160A
200A
250A
Cable Connection
25mm cage
25mm cage
35mm cage
35mm cage
70mm cage
M10 lug
M10 lug
M10 lug
Reference 2 Pole for single phase
ATS 4/2 M2G DS705
ATS 6/2 M2G DS705
ATS 8/2 M2G DS705
ATS 10/2 M2G DS705
ATS 12/2 M2G DS705
ATS 16/2 M2G DS705
Reference 4 Pole for three phase
ATS 4/4 M2G DS705
ATS 6/4 M2G DS705
ATS 8/4 M2G DS705
ATS 10/4 M2G DS705
ATS 12/4 M2G DS705
ATS 16/4 M2G DS705
ATS 20/4 M2G DS705
ATS 25/4 M2G DS705
Enclosure H x W x D
600x400x200
600x400x200
700x500x200
700x500x200
800x600x250
1000x600x300
1000x600x300
1200x600x300
• Switch based panels with manual override.
• MCCB & ACB based panels.
• Over current protection devices.
• Floor standing cabinets.
• Aluminium, Tufnol or brass gland plates.
Built in Suffix /
/12V MPS
/24V MPS
Stand alonereference
160012
160024
Description
12V DC maintainable power supply
24V DC maintainable power supply
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
IP55 Sheet Steel Enclosed MCCBs and RCBOs
IP55 sheet steel enclosed MCCBs and RCBOs have padlockable door interlocked handles, thermomagnetic releases and lug terminations. A complete range of alternative breaking capacities and electronic tripping is available.
• Fully load rated ABB TMAX breakers.
• BSEN60947-2, IEC 60439-1.
• 3 and 4 pole and 4 pole with earth leakage.
• Earth leakage relay features:
- Built-in Toroidal Transformers. - Earth leakage provides variable current
tripping current 0.025 - 25A. - Adjustable time delay 0.02 - 5 sec.
• Spreader terminals and multi cable connection facilities.
• Auxiliaries contacts and other accessories.
• Aluminium, Tufnol or brass gland plates.
10
ReferenceTP & N
ST T1-6/3 16kA
ST T1-10/3 16kA
ST T1-12/3 16kA
ST T1-16/3 16kA
ST T3-20/3 36kA
ST T3-25/3 36kA
ST T4-32/3 36kA
ST T5-40/3 36kA
ST T5-63/3 36kA
Reference 4 pole
ST T1-6/4 16kA
ST T1-10/4 16kA
ST T1-12/4 16kA
ST T1-16/4 16kA
ST T3-20/4 36kA
ST T3-25/4 36kA
ST T4-32/4 36kA
ST T5-40/4 36kA
ST T5-63/4 36kA
Enclosure H x W x D
400x300x200
400x300x200
400x300x200
500x400x200
600x400x200
600x400x200
700x500x250
800x600x250
800x600x250
Reference 4 pole with earth leakage
protection
ST T1-6/4 16kA RCD
ST T1-10/4 16kA RCD
ST T1-12/4 16kA RCD
ST T1-16/4 16kA RCD
ST T3-20/4 36kA RCD
ST T3-25/4 36kA RCD
ST T4 32/4 36kA RCD
ST T5 40/4 36kA RCD
ST T5 63/4 36kA RCD
Enclosure H x W x D
500x400x200
500x400x200
500x400x200
600x400x200
700x500x200
700x500x200
700x500x250
800x600x250
800x600x250
Nominal Rating Ie
63A
100A
125A
160A
200A
250A
320A
400A
630A
Icu Short circuit
breaking
36kA
16kA
16kA
16kA
36kA
36kA
36kA
36kA
36kA
IP41 Sheet Steel Enclosed MCCBsIP41 sheet steel enclosed MCCBs are direct toggle operated have thermomagnetic trip release and cage clamp termination.
Icu Shortcircuit
breaking
36kA
36kA
36kA
36kA
36kA
Nominal Rating Ie
63A
80A
100A
125A
160A
200A
250A
Icu Short circuit
breaking
16kA
16kA
16kA
16kA
16kA
ReferenceTP & N
MC T1-6/3
MC T1-8/3
MC T1-10/3
MC T1-12/3
MC T1-16/3
Reference 4 pole
MC T1-6/4
MC T1-8/4
MC T1-10/4
MC T1-12/4
MC T1-16/4
Enclosure H x W x D
400x230x110
400x230x110
400x230x110
400x230x110
400x230x110
Reference TP&N
MC T3-6/3
MC T3-8/3
MC T3-10/3
MC T3-12/3
MC T3-16/3
MC T3-20/3
MC T3-25/3
Reference4 pole
MC T3-6/4
MC T3-8/4
MC T3-10/4
MC T3-12/4
MC T3-16/4
MC T3-20/4
MC T3-25/4
Enclosure H x W x D
600x300x120
600x300x120
600x300x120
600x300x120
600x300x120
600x300x120
600x300x120
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
Sheet Steel Enclosed 4 pole Contactors
Contactor enclosures are selected to provide adequate wiring room for “standard” cables. Larger enclosures to suit customers individual requirements together with IP65, Stainless Steel and GRP enclosures, are also available.
• 240V coil with fuse protection. • Compact contactor design.
• IEC 60947-4 Rated.
Panel Mounting Double Break Switchfuses
• Contactors with alternative coil voltages, DC ratings, overloads, Isolators and pushbutton controls.
• Earth and Neutral bars of alternative ratings,incoming or outgoing ways and double split links.
11
AC1 Rating
380-440V
25A
40A
60A
80A
100A
135A
155A
200A
260A
AC23Rating
380-440V
5.5kW
11kW
15kW
22kW
30kW
37kW
60kW
75kW
110kW
Reference
ST GMC 2/4
ST GMC 4/4
ST GMC 6/4
ST GMC 8/4
ST GMC 10/4
ST GMC 13/4
ST GMC 15/4
ST GMC 20/4
ST GMC 26/4
IngressProtection
IP41
IP41
IP41
IP55
IP55
IP55
IP55
IP55
IP55
EnclosureHxWxD
300x180x110
300x180x110
300x180x110
300x300x150
300x300x150
400x300x150
500x400x200
600x400x250
600x400x250
Units with alternative coil voltages, DC ratings, overloads, Isolators and pushbutton controls are also available.
Power Rated Earth and Neutral BarsPower rated earth and neutral bars are manufactured on sturdy 60mm din rail for mounting direct to the wall or inside distribution enclosures. Alternative sizes are available.
NominalRating
100A
100A
160A
160A
160A
250A
250A
400A
400A
630A
630A
Outgoing Copper
Bar Dims
25x6x240
25x6x300
25x6x240
25x6x300
25x6x420
25x6x300
25x6x420
40x6x300
40x6x420
40x6x300
40x6x420
OutgoingConnection
6 x M6
8 x M6
6 x M6
8 x M8
12 x M8
8 x M10
12 x M10
8 x M12
12 x M12
8 x M12
12x M12
Incoming Connection
1 x M10
1 x M10
1 x M10
1 x M10
1 x M10
1 x M10
1 x M10
1 x M10
1 x M10
1 x M12
1 x M12
ReferenceNone Splitable
EB6/100
EB8/100
EB6/160
EB8/160
EB12/160
EB8/250
EB12/250
EB8/400
EB12/400
EB8/630
EB12/630
ReferenceSplitable
EMS6/100
EBS8/100
EBS6/160
EBS6/160
EBS12/160
EBS8/250
EBS12/250
EBS8/400
EBS12/400
EBS8/630
EBS12/630
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
Enclosures, Combination and Distribution Units
With the growing demand for combination and distribution units in industrial and commercial environments we have brought together a range of high quality products which we can combine to provide a fast and flexible service.
• The only universal enclosure on the market. Accepts all ranges of industrial sockets.
• A high quality, good looking range of linkable thermoplastic enclosures to EN 60 439-1-3.
• Self extinguishing, double insulated enclosures with high mechanical resistance for aggressive environments.
• A wide range of accessories included for linking and fixing. Metal lock available.
A full range of IP44 caravan, marina and sitedistribution units are also available.
IP65 Acqua Combi Enclosures
12
Description(Smoked cover for modular
devices where fitted)
8 way
9 way sloping front
9 way sloping front
13 way
13 way
6 way
No flap cover
No flap cover
No flap cover
No flap cover
Max no.of sockets
4
2
4
6
0
0
6
8
6
3
Reference with Plain Front
3951
3957
3958
3952
3964
3965
3953
3954
3956
3955
Reference with universal fixing
3961
3962
3966
3963
Dimensions HxWxD
506x230x150
280x220x120
370x220x120
506x330x150
180x330x150
330x180x150
506x230x130
506x330x130
330x330x130
180x330x130
Combination and Distribution Units
• Specialist manufacturers of high quality combination units and
distribution boards to your specification.
• Approved supplier to the Cable TV and Telecoms Industries.
• Units can include:
- A full range of plugs sockets and inlets. - Modular devices including RCD, MCB, RCBO. - Digital and card KWh meters. - Time control devices and other control gear.
• All pre-wired to you specification.
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
IP55 Sheet Steel CT Chambers for Metering
CT chambers can also be supplied assembled with incoming Switchfuses, MCCBs or part of a complete Form 4 distribution panel. Standard unit can also be supplied in GRP enclosures.
• 4x removable busbar links with Insulated CT supports.
• Fuse bank mounted on removable board.
• Full internal sealable shroud (fuse accessible).
• Removable insulated gland plates top and bottom.
Panel Mounting Double Break Switchfuses
• Junction boxes for multi cables per phase.
• Junction boxes for alternative cable sizes.
• Aluminium, Tufnol or letter box brush gland entry.
13
Power terminal enclosures provide a highly flexible solution for large cable management. They can be used as a permanent junction box to terminate or extend large cables or as a generator hook up point for bringing in a temporary supply.
IP55 Sheet Steel Enclosed Power Terminals Power terminal enclosures are selected to provide adequate wiring room for “standard” cables. Larger enclosures to suit customers individual requirements together with IP65, Stainless Steel and GRP enclosures, are also available.
Rated current
400A
630A
800A
Reference 4 pole
STCT 40/4
STCT 63/4
STCT 80/4
EnclosureH x W x D
800x600x300
800x600x300
800x600x300
• 1000V rated power terminals.
• Individual IP2X shrouds.
• Bolt connection for cable lugs.
• Padlockable hinged door enclosure.
• Choice of cable entry.
Lug size
M10
M12
M12
M12
Maximum cable size
95mm2
150mm2
185mm2
240mm2
Minimum cable size
16mm2
70mm2
70mm2
70mm2
Rated current
250A
335A
353A
415A
Reference3 pole
STJB 95/3
STJB 150/3
STJB 185/3
STJB 240/3
Reference 4 pole
STJB 95/4
STJB 150/4
STJB 185/4
STJB 240/4
Reference 5 pole
STJB 95/5
STJB 150/5
STJB 185/5
STJB 240/5
Enclosure H x W x D
600x400x200
700x500x200
800x600x250
800x600x250
Switchgear Systems Ltd. Tel: 01788 577399. Email: [email protected]
Special
Requirement?
Just Ask!
Top Related