    Electric fuel pump 4.0 barfor Audi

    Vehicle: Audi Product: Electric fuel pump (E2TS)Type Engine Model year Pierburg-No. O.E.-No. *)80 / Avant / Quattro 7.18259.50.0 8 A0 906 091 A

    100 / Avant / Quattro various 8 A0 906 091 G200 / Avant / QuattroA6 / Avant / Quattro see TECDOC-CD

    Coupe / QuattroV8 Quattro

    In case of replacement, the in-tank pumps fitted inthe above mentioned vehicles can be replaced withthe PIERBURG fuel pump Fig. 1.

    Test dataRated voltage: 12 VSystem pressure: 4.0 barDelivery quantity: 110 l/hPower consumption: 9 A at system pressure

    Notes on fitting and removalsee overleaf

    Fig. 1

    ssi 0018 / A GB

    MSI-PG 08.01

    MSI Motor Service International GmbH D-41456 Neuss Phone (02131) 520-0 Fax (02131) 520-663 E-Mail: [email protected] A Company of Kolbenschmidt Pierburg AG -

    Subject to change of illustrations and text.For changes with regard to respective matching and replacements, referto the catalogs,TECDOC-CD or systems basing on TECDOC-data,which are currently in effect.

    *) The listed reference numbers should be listed for comparison only.They may not be used on invoices sent to final users.

    Fuel

    sup

    ply

  • Abb. 2

    Abb.6Abb. 3

    Abb.5

    Abb. 4

    X

    X

    Notes on fitting and removal

    Observe the arrow mark on theflange and the tank (fig. 2).

    Observe the position of theupper part of the ram housing inthe tank (keep the V marking inmind, fig. 3).

    In case of shaped hoses orhoses with angle screwingbetween pump and flange, theposition (X) must be used forreinstallation, see example in fig.4 and fig. 5.Before the removal, rememberor mark that position.

    The Pierburg pump isapproximately 2 mm longerthan the standard pump. As aresult,the holders (arrows, fig. 6)dont lock into position auto-matically during installation.Correct with a screw driver asnecessary.

    Insert and install cable and hoselines so that they are not tenseor twisted when installed.