ZoneTouch V2 Zone Control System User...

20
ZoneTouch V2 Zone Control System User Manual www.polyaire.com.au ©2014 Polyaire Pty Ltd

Transcript of ZoneTouch V2 Zone Control System User...

Page 1: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZoneTouch V2 Zone Control System

User Manual

www.polyaire.com.au

©2014 Polyaire Pty Ltd

Page 2: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual II

Page 3: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

1) Features 2

2) Wall Controller Layout (Touch Screen) 3

3) Manual Group Control 4 3.1 Group On/Off/Turbo 4 3.2 Adjusting airflow for a group 5

4) Automated Group Control 5 4.1 Set Program 6 4.2 Select Program for a Group 7

5) User Settings 8 5.1 Time/Date setup 8 5.2 Owner’s Name 9 5.3 Turbo Group 9 5.4 Temperature Display 10 5.5 Touch Tone 10

6) Information Sheets 11

7) Troubleshooting Guide 14

8) Specifications 15

TABLE OF CONTENTS

LiabilityPlease read the instructions before installing this Zonemaster Zoning Control System. Polyaire Pty Ltd does not accept any responsibility for loss or damage that may occur as a result of the incorrect installation of this Zonemaster Control System.

Page 4: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 2

1) Features • Userfriendlylargetouchscreeninterface • Intuitiveuserinterface • Controlairflowtoindividualzones1 and groups2

• ColourLCDforclearerdisplay • Personalizedsystemsettingsandlabelling • Wallmountedwithuptotwotouchscreensavailableinasystem • 5-1-1ProgrammableOn/Offtimeprograms • Oneselectableturbo3 group to cool/heat a particular area quicker • Halfyear,OneyearandTwoyearservicereminderstocalltechnicianforcleaning andservicingACsystem4. • Allzonesautomaticallyresumetheiroriginalon/offstateoncepowerisrestored afterpoweroutage. 1. A zone is the area where air supply is controlled by one motorized damper

2. A group is a few zones grouped together which have the group name and are controlled (turning on and off,oradjustingopeningpercentage)atthesametime.Agroupwillhaveatleastonezoneandnomore than four zones.

3. Turbo function will give the selectedgroupafull-openingwhileallothergroups’(dampers)opening positions are reduced by 50% of their open percentage value. This will bring a large volume of extra air into the designated area and cool or heat the area quicker.

4. AC system is the ducted air conditioner which has ZoneTouch V2 as its zone control system.

Page 5: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 3

2) Wall Controller Layout (Touch Screen) The home screen of the system willnormallydisplaygroups’status,dampers’open percentagewithadjustingbuttons,date,time,roomtemperature,touchtonestatus andZoneTouchlogoasshowninFigure1.

NOTE: • The touch screen will go to the sleep mode after 90 seconds of inactivity. In sleep mode, the screen is blank. Touching any area of the screen will activate the system. • To clean the touch screen, use a dry, soft cloth and very gently wipe the screen. If necessary, dampen the cloth with distilled water or with an equal ratio of distilled water to white vinegar.

Home Screen (Figure 1)

Page 6: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 4

3) Manual Group control 3.1 GroupOn/Off/Turbo a) Onthehomescreen,touchagroupbutton(Figure2)tochangetheon/off groupstatusandthedampersofthegroupwillopenorcloseaccordingly.

b) Thegroupstatuscanbesetto‘TURBO’activewhenthegroupisspecified asaturbogroup(referto5.3)andthegreyturboindicatorwillturnblueto indicatetheTURBOfunctionisactive.Figure3showsthegroupstatus sequence alternated by touching the group button.

c) Upto6groupbuttonsareshowninonescreenandtouch< or > to bring up previousornextpage.

Figure 2

Figure 3

Page 7: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 5

4) Automated Group Control Automatedon/offcontrolforeachgroupisanimportantfeatureoftheZoneTouchV2 system.Thissystemhasthreeprogramscenarios,oneforweekdays(Mondayto Friday),oneforSaturdayandoneforSundayrespectively. Eachprogramscenariohas4programmableeventsperday:ontime1,offtime1,on time2andofftime2.Eachprogrameventcanbeenabledanddisabledandthetime canbeadjustedasdesired.Allfoureventsaredisabledinthefactorydefaultwith settingsaslistedinthetablebelow.Userscancreateupto4programsusingthe scenariosanddifferenteventtimeslots.

NOTE: A group can have up to a maximum of 4 zones. Your installer would have already set up your zones and groups.

3.2 Adjustingairflowforagroup • Thedamperopeningpercentageforeverygroupcanbeadjustedtocontrol theamountofairflowateveryoutletbetween10%and100%ofthebalanced value(setupbyInstaller)at10%increments. • Touch or buttons on the home screen to increase or decrease the percentage opening for the corresponding group. • TheairflowwillbeunadjustableiftheTurbofunctionisactive.Pressing andwillnotchangetheopeningpercentage.

NOTE: The Turbo function cannot be programmed. It is activated manually from the touch screen as needed.

On time 1 Off time 1 On time 2 Off time 2

Monday to Friday 6.30AM 8.00AM 5.30PM 10.00PM

Saturday 7.30AM 12.30PM 6.00PM 11.30PM

Sunday 7.30AM 12.30PM 6.00PM 11.30PM

Page 8: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

4.1 Set Program Uptofourprograms can be created. Touchingbuttonwillgobackto the home screen from programming setting pages.

a) Touch Program buttons (e.g. )on‘programming’screen(Figure4) toenterthescreen(Figure5)toselectscenariosandadjusttheeventtimes.

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 6

Touch the button on the home screen toenter‘Programming’screen(Figure4).

Figure 4.

Figure 6.

b) TouchadayoptionradiobuttontoselectMonday-Friday,Saturdayor Sundayprogramtomodify.Touchthetimeswitchradiobuttonontheright toenable/disableON/OFFtime. c) Touchthehour,minuteorAM/PM fieldonthescreentohighlightit, and then the and buttons willappearonthescreen(Figure6). Touchorbuttonstoadjust the time. NOTE: Afteraneditfieldis highlighted,touchingthatfieldagain will quit from the editable status and the and will disappear.

Figure 5

Page 9: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 7

Figure 7.

4.2 Select Program for a Group Enterthe‘Assignment’screen(Figure 7) by touching on programmingscreen(Figure4). Assignmentscreenshowsthelistof the current program of each group. Touchingbuttonwillgobackto thehomescreenfromAssignment page.

Figure 8.

Figure 9.

Figure 10.

Touchtheprogramfieldofagroupto showallprogramoptions(Figure8). Touchingaprogramoptionwillassign theprogramtothegroup(Figure9). Eachgroupcanbeassignedwithone program from program1 to program4 (‘P1’to‘P4’),andthegroupwillnot haveaprogramif‘No’isselected.Ifa program has been assigned to a group, theprogramindicatorwillappearon thegroup(Figure10)ifanyofthefour eventsintheprogramisenabled.

NOTE: Programs cannot be assigned to a group with turbo status. Record programs and groups to ‘Table 5: Programs’ on Page 13

Page 10: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 8

a) Touch on the home screen (Figure1)enter“Settings”screen (Figure11) b) Touch to enter ‘user settings’screen(Figure12) InUserSetting,youcansetupdate andtime,owner’sname,Turbogroup, temperature display and touch tone. Touchingbuttonwillgobackto thehomescreenfromUsersetting pages.

Figure 11.

Figure 12.

5) User Settings

Figure 13.

Figure 14.

5.1 Time/Date setup a) Touch on the‘User Settings’screen(Figure12)toenter the time/date setup screen (Figure13). b) Hour,Minute,AM/PM,day,month andyearfieldswillbeshownonthe screen.Touchthefieldwhichneed tobemodified,thentouchor buttontochangethevalue (Figure14).

c) Touch buttontosavethe changesandgobacktoUser Setting page.

Page 11: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

5.2 Owner’s Name Themaximumlengthofthenameis16 letters. Goto‘UserSettings’screen(Figure12). Touch‘OwnersName’tochangethe owner’snamebyusingthekeyboardshown onthescreen(Figure15).Touchto switchbetweenlowercaseanduppercase andtouchtoconfirmthenameor touch or to cancel the change.

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 9

Figure 15.

5.3 Turbo Group Touch ‘TurboGroup’tospecifyagroupasaTurboGroup.Turbofunctionwillgive theselectedgroupafull-openingwhileallothergroups’(dampers)openingpositions arereducedby50%oftheiropenpercentagevalue.Thiswillbringalargevolumeof extraairintothedesignatedareaandcoolorheattheareaquicker.Typicallythis may be a family room, dining room or home theatre (or in commercial application a meeting, lunch or board room). Touch the‘TurboGroup’fieldonthe‘User Settings’screen(Figure12),todisplaythe listofavailablegroupname(Figure16). Choose the desired group name as the turbogroup.Thegreyturboindicatorwill appearonthegroupbuttonafterit’schosen as Turbo group. NOTE:Tomakethespecifiedgroupstart to work in turbo mode, the group status needs to be turned to ‘turbo’ on the home screen (3.1).

Figure 16.

Page 12: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 10

5.4 Temperature Display Touch the radio button of to enable or disable the temperature displayonthetouchscreen.Belowimagesshowtheenabledstatus(Figure17)and disabledstatus(Figure18)oftemperaturedisplay.

5.5 Touch Tone The touch tone feature allowstoeitherenableordisablethetonewhenthescreenis touched.Itisdisabledasdefaultandwilldisplayamutelogoonthescreen. Touchtheradiobuttonoftoswitchthetouchtoneonoroff.

Figure 17. Figure 18.

Page 13: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 11

6) Information Sheets Theseshouldbefilledoutbytheinstaller

Total Groups Bypass Damper Installed

Supply Air Sensor Installed

Yes/No Yes/No

Group Group Name Zones Included Turbo Function

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

G

Table 1: System Configuration

Table 2: Grouping

Page 14: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 12

Installer Contact Number Date

Zone Balance Percentage

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

Zone 9

Zone A

Zone B

Zone C

Zone D

Zone E

Zone F

Zone G

Table 4: Installer Details

Table 3: Balance

Page 15: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 13

Table 5: Programs

PROGRAM 1 On time 1 Off time 1 On time 2 Off time 2

Monday-Friday

Saturday

Sunday

Groups

PROGRAM 2 On time 1 Off time 1 On time 2 Off time 2

Monday-Friday

Saturday

Sunday

Groups

PROGRAM 3 On time 1 Off time 1 On time 2 Off time 2

Monday-Friday

Saturday

Sunday

Groups

PROGRAM 4 On time 1 Off time 1 On time 2 Off time 2

Monday-Friday

Saturday

Sunday

Groups

Page 16: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 14

7) Troubleshooting GuidePROBLEM SUGGESTED ACTION

Dampers have no response when turned on or off

• Checkifthe‘SafetyisActivated’errorisdisplayed.Highlimit(Heating) orLowlimit(Cooling)mayhavereached.Checktheair-conditionerto seeifitisoperatingnormally.ZoneTouchV2systemwillresumeto operationalafterthesupplyairtemperatureiswithinsafetyrange.• *CheckifSupplyairsensorispluggedinthemainboardandHighLimit &LowLimitisenabled.Ifthesensorisnotpluggedin,plugthe sensorandthesystemwillbeoperationalafteraminute.Ifthesensor isnotrequired,disableHighlimitandLowlimitfromtouchpadand systemwillreturntooperationalinaminute.• *CheckifLEDsonthemainmodulelightupforrelevantzoneswhen thezonedampersarebeingturnedOn/Off.IfGreen/RedLEDsarenot activatedfortherespectivezone,themainmodulemaybefaulty,replaceit.• *Checkif the cable from touchpad to the main control module is faulty. Ifitisafaultycable,thenthecablemighthavetobereplaced.

Some zones cannot be turned off

• Checkif‘Spillisactivated’isdisplayedontheLCDscreen.• Checkif‘Spill’statusisdisplayedfortheGroupstatusinthehome screen.Openingotherzoneswillrectifytheerror• *Ifallzonesareturnedonbutthetotalopeningpercentagedoesn’t meettherequiredspillpercentage,thentheSPILLwarningmessage willbedisplayed.Increasingtheopeningpercentageofafewzones willresolvetheissue.• *Checkspillset-point.

No display on the LCD • *Checkifthecableispluggedinproperly.Unplugthecableand reconnect it.• *Checkifthereispowertotheunit.

LCD Display Corrupted

• ResetLCDbyholdingRESETbuttonatthebottomoftheTouchpadfor 2s.• *Iferrorisstillnotresolved,resettouchpadbyunpluggingthecable frombehindandthenreconnectitafteracoupleminutes.Ifthe corrupteddisplayremains,poweroff/onthemainboard.Otherwise, replace the touchpad.

Some zones are not operational

• *CheckGroupingandfindoutiftherightzoneshavebeenassignedto therightgroupsandhavebeenturnedON/OFFinZoningsection.• *Checkifthetotalgroupnumberandzonenumberarecorrect.• *CheckiftheLEDsonthemainmodulelightupfortherelevantzones whenthezonedampersareturnedOn/Off.Ifthereisnoresponse, theremightbeafaultycableandthecablewouldhavetobereplaced. Ifthezoneisstillnon-functionalthentheremightbeafaultydamper motor.

*: Thesechecksintheguideshouldbecarriedoutbyqualifiedpersonnel. If you have any doubt regarding the above please contact your installer.

Page 17: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 15

8) Specifications

Electrical Requirements Powersupply: 24VAC±10% Linefrequency: 50Hz

Components Power Consumption Touchpad: 0.5VA MainControlModule: 5VA

Environmental Requirements Operatingtemperature: 0°Cto60°C Altitude: 0to2000meters Operatingrelativehumidity: 10%to80% Avoidstaticelectricityhazards Avoidelectromagneticradiationsources Avoiddustcontamination Avoidhighlycorrosiveenvironments

Zone Output Outputvoltage: 24VAC,50Hz Current: 200mA(1dampermotor)

Transformer InputVoltage: 240VAC,50Hz OutputVoltage: 24VAC,50Hz Wattage: 40W

Supply Air Sensor: NTCtype,10kΩat25°C

Battery: 3.6V,3xAAAM RechargeableforMainModule

Fuse: Dimension5x20mm, Fast-Acting2A,250V

Page 18: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 16

Page 19: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 17

Page 20: ZoneTouch V2 Zone Control System User Manualductair.com.au/wp-content/uploads/2016/09/ZoneTouchV2_UserManual2014... · ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1

ZMZT2_USER_V1.0

POLYAIRE PTY LTD11-13WHITEROADGEPPSCROSS

SOUTHAUSTRALIA,5094TEL:(08)83498466FAX:(08)83498446

www.polyaire.com.au