XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation &...

27
VT600 XtraV ac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ∙ Kansas City, MO USA Tel. 800-728-2999 ∙ Fax 816-472-1999 [email protected]

Transcript of XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation &...

Page 1: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

VT600

XtraVac • VT600 (PLC)Vacuum Tumbler

Operation & Parts Manual

A Division of the Inauen Group ∙ Kansas City, MO USATel. 800-728-2999 ∙ Fax 816-472-1999

[email protected]

Page 2: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

Safe Operation Practices General Operation

• Read, understand, and follow all instructions in the manual and on the machine before starting. Keep this manual in a safe place for further reference and ordering replacement parts.

• Only allow trained personnel familiar with the instructions to operate the machine. Be sure to understand all controls and how to stop the machine quickly.

• Do not put your hands near moving parts. • Remove all obstacles, which may interfere with the machine functions. • Clear the work area of items such as electrical wires, gloves, knives, etc. • Be sure that everyone else is clear of your work area before operating the machine. • Do not sit nor stand on the machine. • Be sure turn off the machine after your work is finished. Never leave a running machine

unattended. • Always disconnect and wait until the machine has cooled before doing any maintenance. • Do not wear loose fitting clothes or jewelry as they may get caught in moving parts of the

machine. • Please wear appropriate shoes and clothes to avoid injury caused by moving the machine

or objects falling from the machine. • Never position the machine on an incline more than 30 degrees, it may tip over and hurt

someone seriously.

Your responsibility

This machine should only be operated by personnel who can read, understand and respect warnings and instructions regarding this machine in the owners manual.

XtraVac Packaging Machines VT600 Vacuum Tumbler

1 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 3: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

Content

Chapter 1:Safety precautions

1.1 Precautions of transportation, installation and packing 1.2 Precautions before and after machine starting Chapter 2:Overall description of the machine 2.1、Features of the machine 2.2、Function of the machine 2.3、Product proper for this machine 2.4、Usage life of the machine 2.5、Specification of the machine

Chapter 3:Function description of the push buttons on the panel & Operation sequence description

Chapter 4:Instructions of operation, maintenance and troubleshooting

4.1、Operation sequence 4.2、Maintenance 4.3、Troubleshooting

Chapter 5:Related environment and accessories of the machine

5.1、Accessory 5.2、Airborne noise level 5.3、Operation environment

XtraVac Packaging Machines VT600 Vacuum Tumbler

2 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 4: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

Chapter 1:Safety precautions

1.1 Precautions of transportation, installation and packing:

1.1.1 Preparations before installation

1.1.1.1、Power requirement:

Voltage: Can be set suited to location and needs

Current: 7.7kW

Frequency: 50/60 Hz

Phase: 3ψ

1.1.1.2、Installation requirements:

1.1.1.2.1、Do not install the machine in an environment full of dust or corrosive with acid

and alkali.

1.1.1.2.2、Do not install the machine in an environment with abnormal vibration.

1.1.1.2.3、Do not install the machine in direct sunlight or near vapor. This may affect its

vacuum degree.

1.1.1.2.4、The ground circuit should be independent or parallel.

1.1.1.2.5、Don’t install the machine in a potentially explosive environment

1.1.1.2.6、Installation space includes the requirement of the operator and machine

Length × Width × Height =2M x 2.4M x 2.15M

XtraVac Packaging Machines VT600 Vacuum Tumbler

3 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 5: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

VT600

XtraVac Packaging Machines VT600 Vacuum Tumbler

4 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 6: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

1.1.2、Preparations during transportation:

1.1.2.1、The weight of this machine is 400~500 kg, so that the loading capacity of any

handling device is recommended to be more than 1500 kg. If you are not sure of the

safe loading capacity, please contact the manufacturer for questions about handling

devices.

1.1.2.2、It’s important to check the balance carefully in advance of moving or placement.

1.1.2.3、Lifting or by handling should be carried out by means of qualified operator.

1.1.2.4、During machine handling and positioning, keep clear of the of the machine.

1.1.2.5、Before handling, be sure that there are no people or barriers obstructing the

machine movement. Clear any object prior to movement.

1.1.3、Machine transportation packaging:

1.1.3.1、Packing material: The base is wood.

1.1.3.2、Packing sequence: Put the wood base on the ground. Then, put the machine on it. Fix

the machine foot to the wood base, pack the machine with plastic film and put

vibration-absorbing board around the machine.

1.2 1.2、Precautions before and after machine starting:

1.2.1、Precautions before machine starting

1.2.1.1、Before using this machine, read and understand the contents of this manual and the

control interface entirely.

1.2.1.2、Check that voltage and power connections are appropriate.

1.2.1.3、Confirm that the electric power and rating is sufficient.

1.2.1.4、Check that all the safety related devices are normal, and that the Vacuum Tumbler is

clear of obstructions.

1.2.1.5、Visual check that all mechanical and electric parts are normal, and check that the

XtraVac Packaging Machines VT600 Vacuum Tumbler

5 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 7: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

surrounding environment is clean.

1.2.1.6、Power On Sequence:

1.2.1.6.1、Turn on the factory power.

1.2.1.6.2、Turn on the main switch of the machine.

1.2.2、Precautions after machine starting:

1.2.2.1、Confirm that the display is correct.

1.2.2.2、Confirm that the sound coming from pump running is normal (refer to clause 3.15.2).

1.2.2.3、Wear safety shoes, protective clothes and mask to ensure safety and hygiene of the

operator.

Chapter 2:Overall description of the machine

2.1、Features of the machine:

2.1.1、The machine main body is made of stainless steel for great endurance and easy

washdown.

2.1.2、The machine uses high-powered vacuum pump (imported from Europe) with

water-resistant design.

2.1.3、The machine is fitted with easily-recalled memory functions and a user-friendly

display.

2.1.4、It is designed for large processing operations & food industry factories.

2.1.5、The machine main body is made of stainless steel, water-proof, heat-proof, easy cleaning,

loading entrance is a specialized design.

2.2、Function of the machine:

2.2.1、Repeat tumbling, mixing product with sauce completely, enhancing the tenderness of

product.

XtraVac Packaging Machines VT600 Vacuum Tumbler

6 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 8: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

2.2.2、Bulk marination and pickling Automatically, not by manual.

2.3、 Proper products for this machine:

2.3.1、Fresh meat, seafood, agricultural products, prepared food, pickles, and powdery

products …etc.

2.4、Usage life of the machine:

2.4.1、Except the consumable parts and under normal operation, the machine’s intended usage

life is 10 years.

2.4.2、12 month limited warranty for maintenance, parts, and service after shipping. The date is

calculated from the end of installation.

2.4.3、After the warranty, XtraVac will be happy to assist with any parts or service.

(+1 800-728-2999, [email protected])

2.4.4、Warranty maintenance service doesn’t include consumable parts and vacuum oil.

2.4.5、If there is any abnormal or unsafe situation during the machine warranty period, please

inform XtraVac. We will respond immediately.

2.5、Machine Specifications:

Type VT600 Machine dimension 1480 x 1200 x 1570 mm Maximum Capacity 480L Machine Weight 450kg Vacuum Pump 2hp

XtraVac Packaging Machines VT600 Vacuum Tumbler

7 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 9: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

Chapter 3:Instructions of PLC System Functions

SYS

F4F3F2F1

(Picture 1)

a: Power Switch

b: Unloading

c. Loading

d. PLC Screen

XtraVac Packaging Machines VT600 Vacuum Tumbler

8 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 10: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

3.1、Turning the machine on launches this screen (below). Touching Enter navigates to (picture 3).

(Picture 2)

Online at XtraVac.comE-mail: [email protected]

Enter

TEL:+1 800-728-2999 FAX:+1 800-472-1999

XtraVac Packaging Machines F1F2F3F4

SYS

XtraVac Packaging Machines VT600 Vacuum Tumbler

9 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 11: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

3.2、Touch Enter to navigate to this screen (Picture 3)

Tumbling Rate

VacuumHold

OFFOFFOFF

StartVacuumSwitch

IndexScreen

SurveillanceScreen

Abnormal Screen

HZMINMINMIN

# # # #

12341234

SV

PV

Tumbbling Time

AutomaticOperation ScreenStop F1F2F3F4

SYS

# # # # # # . # ## # # #

1234 12.34

Rest Time

(Picture 3)

3.2.1、A- STOP: When the machine stops running, this screen would read Stop.

When the machine starts running, this screen would read ON. B- Operation Screen: This screen indicates each setting’s current value. And the

current running status of the machine.

C- Automatic/Manual: Switch to manual function or Automatic function D- Tumbling Time: The PV is present value, SV is the setting value. Touch the SV

button to bring up the value keypad if the value is to be changed. (unit: min)

E- Resting Time: The PV is present value, SV is the setting value. Touch the SV

button to bring up the value keypad if the value is to be changed.

XtraVac Packaging Machines VT600 Vacuum Tumbler

10 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 12: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

(unit: min) F-Total Time: The PV is presenting value, SV is the setting value. Touch the SV

button to bring up the value keypad if the value is to be changed. (unit: min)

G-Tumbling Rate: The PV is presenting value, SV is the setting value. Touch the SV

button to bring up the value keypad if the value is to be changed. Maximum 60 Hz

H- Switch to Abnormal screen I- Switch to Surveillance screen

J- Switch to Index screen K- Vacuum Switch: When it is OFF, touch to start the vacuum pump.

L- Vacuum Hold: Touch to hold the vacuum pressure of the drum when total time is achieved.

M-Start: When it reads ON, the vacuum tumbler runs automatically. When it reads OFF, the vacuum tumbler runs in semi function.

XtraVac Packaging Machines VT600 Vacuum Tumbler

11 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 13: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

3.3、Touching the Surveillance Screen launches this screen (Picture 4)

IndexScreen

# # . # #

FrequencySwitching Time

Done

VacuumPressure

Surveillance ScreenStop F1F2F3F4

SYS

BrakeOFF

VacuumHold

PumpOFF

ConverterOFF

Operating

S S

Evacuation Time

# # # #

OperationScreen

AbnormalScreen

(Picture 4)

3.3.1、

A- Stop: When the machine stops running, this screen would read Stop.

When the machine starts running, this screen would read ON.

B- Switch to Surveillance screen

C- Operating: It displays the present progress of vacuum tumbling.

D- Done: After all works are finished, touch it to reset.

E- Vacuum Pressure: When the vacuum pressure is achieved, it will read ON.

F- Brake: When the motor of vacuum tumbler runs, it would read ON.

G- Vacuum Hold: Touch it to hold tha vacuum pressure after the cycle is finished.

It would read ON.

H- Vacuum Pump: When the vacuum pump runs, it will read ON.

I- Converter: It reads ON when Converter is running, and OFF when it is not.

J- Switch to Index screen.

K- Switch to Operation Screen

L- Switch to Abnormal Screen

M- Frequency Switching Time: When the Tumbling time is achieved, it will work.

The vacuum drum will slowly rotate.

XtraVac Packaging Machines VT600 Vacuum Tumbler

12 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 14: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

N- Evacuation Time: touch it could change the evacuation time.

3.4、Touch the Abnormal Screen and will go into this screen (Picture 5)

IndexScreen

OperationScreen

SurveillanceScreen SYS

F4F3F2F1Abnormal Screen

Tumbler Done

Vacuum Motor

(Picture 5)

3.4.1、A-Switch to the Abnormal Screen.

B- Tumbler: If the motor of tumbler is abnormal, it would read abnormal and blink. Then

the machine stops working.

C- Vacuum Motor: If the vacuum pump is abnormal, it would read abnormal and blink.

Then the machine stops working.

D- Done: To solve the machine problems, to touch the Done key to stop the current cycle.

E- Switch to the Index Screen.

F- Switch to the Operation Screen.

G- Switch to Surveillance Screen.

3.4.2、Sequence of trial run:

3.4.2.1、Connect the power. Turn the power switch on.

Caution, remember to ground the machine.

XtraVac Packaging Machines VT600 Vacuum Tumbler

13 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 15: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

3.4.2.2、It will go into the main screen (Picture 2), switch it into the Operation Screen

(Picture 3)

3.4.2.2.1、Trial vacuum pump run: When the Start key (M) is off on the Operation Screen

(Picture 3), touch ON the Vacuum Switch key (K) and the vacuum pump will run.

If the pump sounds smooth, it’s rotating clockwise. If there is abnormal noise, it’s

rotating counterclockwise, turn off the machine immediately. Then, change the

power wires w1、v1. (Page 25-M1)

Precaution: After the trial, turn off the vacuum pump.

XtraVac Packaging Machines VT600 Vacuum Tumbler

14 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 16: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

Chapter 4:Instructions of operation, maintenance and troubleshooting

4.1. Operation sequence

4.1.1、Loading sequence: Make sure to connect the power line and ground line properly.

Pump is properly run, and all pipes are connected. Open the Air tightness cover

(Page19-1), Press the Loading button (Page 19-20-1), the rotating speed can be

adjusted by the Tumbling Rate key (G) on the Operation Screen (Picture 3) for

modification.

4.1.2、Running sequence: Touch the Start Key (M) on the Operation Screen (Picture 3), the

vacuum drum starts working, the rotating speed can be adjusted by the Tumbling Rate

Key (G) on the Operation Screen (Picture 3) for modification.

4.1.3、Unloading sequence: After finishing the rotating of the vacuum drum, it will be

evacuated. (The Vacuum Hold key on the Operation Screen (Picture 4) reads ON, the

vacuum pressure on the vacuum drum remains.)

Touch OFF the Start key of the Operation Screen (Picture 3), it will read OFF and will

be in the SEMI function mode. Open the Air tightness Cover (Page 19-1), press the

Unloading button (Page 19-20-2) for the product unloading.

4.1.4、Adjust the rotating speed: Enter to the Operation Screen (Picture 3) and touch the SV

of the Tumbling Rate; it will present the value keypad for choice of the value. It can

increase or reduce the rotating speed when the vacuum drum is rotating.

4.2、Maintenance

4.2.1、Cleaning of the drum: After running, use water to clean inside the drum and wipe with

dry cloth.

XtraVac Packaging Machines VT600 Vacuum Tumbler

15 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 17: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

4.2.2、Cleaning of the filter: Check the water of the filter if it is filled on schedule. If it is

over two-thirds of the amount, pour out the water. Before taking off the filter, please

press the pressure exhaust button (Page19-5-3) first.

4.2.3、Vacuum oil replacement.

4.2.3.1、Recommended vacuum oil: BP Engergol RC100, Esso Nuto H100, Mobil Rarus 427.

4.2.3.2、Drain the previous oil completely before filling new oil

4.2.3.3、Oil capacity should be kept at least two-thirds of total amount.

4.2.4、Change the oil of the vacuum pump for every 300 hours. Also check the oil level from

oil sight glass every week. Oil capacity should be kept at least two-thirds of total

amount. If the oil is dirty, please replace it immediately.

4.2.4、Detail drawing of the oil pump

1. air release hole

2. oil filling hole

3. oil sight glass

4. oil draining hole

XtraVac Packaging Machines VT600 Vacuum Tumbler

16 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 18: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

Chapter 5:Related environment & machine accessories

5.1、Accessory:

5.1.1、Standard accessory:

5.1.1.1、Vacuum tube:.

5.1.1.2、Sucking tube:

5.2、Noise level:79.4dB(A).

5.3、Storage condition:

5.3.1、Temperature: 0℃~45℃.

5.3.2、Humidity: 20~95%RH.

5.4、Operation environment:

5.4.1、Temperature: 5℃~40℃.

5.4.2、Humidity: 20~95%RH.

5.4.3、Attitude: 0~1000M sea level.

5.4.4、Space requirement:

5.4.4.1、It’s necessary to provide enough space for heat emission, handling and maintenance.

5.4.4.2、The machine should not be installed in a position close to other machines.

XtraVac Packaging Machines VT600 Vacuum Tumbler

17 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 19: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

Time parameters of operating the Vacuum Tumblers

Vacuum Tumblers Suggestion

Vacuum Time

Suggestion

Resting Time

Suggestion

Total Time

VT150L~VT600L 10~15 min 3~6 min 1~5 hr

VT1000L~VT3000L 15~20 min 5~10 min 3-10 hr

Note: The above parameters are just for reference, you may use the best suitable times for each product.

XtraVac Packaging Machines VT600 Vacuum Tumbler

18 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 20: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

XtraVac Packaging Machines VT600 Vacuum Tumbler

19 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 21: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

XtraVac Packaging Machines VT600 Vacuum Tumbler

20 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 22: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

XtraVac Packaging Machines VT600 Vacuum Tumbler

21 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 23: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

VT600

No Description No Description

1 Air tightness cover 19 Vacuum Valve 1-1 Sucking entrance valve 20 Product load in/unload controller

1-2 Cover gasket 20-1 load in button

2 Tub body 20-2 unload button

3 Base 21 PLC

4 Rotator 22 Unloading 4-1 Rotator fixing screw 23 Loading 5 Filter 24 Main switch

5-1 Entrance 25 PLC-1 5-2 Exit 26 PLC-2 5-3 Pressure exhaust button 27 Relay 6 Reduction device motor 28 Fuse 7 Transmission chain 29 Terminal block 2 8 Back cover 30 Over load relay 9 Outer bushing 31 Vacuum gauge

9-1 Fixing handle 32 Terminal block 1 10 Pressure exhaust valve 33 Speed adjusting controller 11 Bushing fixing base 34 Adjusting knob

12 Micro switch 13 Cam

14 Gear wheel

15 Bearing

16 Inner bushing

16-1 O ring

16-2 O ring

17 Air exhaust tube 18 Vacuum Pump

XtraVac Packaging Machines VT600 Vacuum Tumbler

22 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 24: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

STAND

ARD

CH

ECKED

PRO

CESSED

NAM

ED

ATEC

IRC

UU

IT DIAG

RAM

PAGE

E D C B A

E D C B A

Converter

Power supply MSC

FF2 1

Vacuum m

otorTum

bler motor

Brae

Exhaust

PLC

XtraVac Packaging Machines VT600 Vacuum Tumbler

23 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 25: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

STAND

ARD

CH

ECKED

PRO

CESSED

NAM

ED

ATEC

IRC

UU

IT DIAG

RAM

PAGE

E D C B A

E D C B A

PU

manual rotating

manual reversal

Abnormal indicator

Tumbler position sw

itch

Motor broken

Reach of prossure

Slow

Com

mon point

Rototing

Reversal

Slow

Vacuum m

otor

Broke

Exhanst valve

manu / Auto

XtraVac Packaging Machines VT600 Vacuum Tumbler

24 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 26: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

STAND

ARD

CH

ECKED

PRO

CESSED

NAM

ED

ATEC

IRC

UU

IT DIAG

RAM

PAGE

E D C B A

E D C B A

3~ MRST

L1L2L3W V U

T3 T2 T1

RARBRC

FWD

REV

DCM

M11

VFD

-BRS-485 Series m

essage

Rotating

Reversal

Slow

Com

mon point

ConverterAbnorm

al indicator

Motor

XtraVac Packaging Machines VT600 Vacuum Tumbler

25 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]

Page 27: XtraVac VT600 Vacuum Tumbler Manual PLC - … XtraVac • VT600 (PLC) Vacuum Tumbler Operation & Parts Manual A Division of the Inauen Group ˜ Kansas City, MO USA Tel. 800-728-2999

STAND

ARD

CH

ECKED

PRO

CESSED

NAM

ED

ATEC

IRC

UU

IT DIAG

RAM

PAGE

E D C B A

E D C B A

56-7-34019

Power base

Vacuum m

otor

Vacuum

pressure sw

itch

XtraVac Packaging Machines VT600 Vacuum Tumbler

26 419 E. 11th Ave. North Kansas City, MO 64116 USA +1 800-728-2999 • [email protected]