25/11/01 3/10
2. Disconnect the Com cable from the Com1 slot in the computers rear side.
3. Connect the JET 110 cable to the Com slot in the computer.
Note: All Scitex XLjet machines are equipped with the JET 110 cable that is not used
for everyday machine operation. The JET 110 cable is only used for testing themachine driver and the driver parameters set loading.
COM 2(Not used)
COM 1
PS/2 sockets
(keyboard and mouse)
RIP SCSI connector
PC AdaptorSCSI connector
PC Adaptor D-type connector
Protection plug
Monitor COM
Power input socket
Output socket for monitor
Network connector
SCSI connector(not used)
JET110
-
8/10/2019 xl1500 tn11
4/10
Loading the Driver Parameters
25/11/01 4/10
4. Using the machine key, open the Scitex XLjet right cover of the driver unit.
5. Connect the other end of the JET 110 cable to the driver as shown in the picture
below.
6. Close the Scitex XLjet application window.
-
8/10/2019 xl1500 tn11
5/10
Loading the Driver Parameters
25/11/01 5/10
7. Locate the YASAKAWA shortcut icon on the desktop and open the software.
Note: In the first screen that appears you will be prompted to choose an online
connection.
-
8/10/2019 xl1500 tn11
6/10
Loading the Driver Parameters
25/11/01 6/10
8. After you choose an online connection a dialog box will appear, containing
information about the type of hardware that has been detected by the software.
Click OK if this information is correct.
9. The main software window will appear.
10. Press the Edit Parameters icon.
-
8/10/2019 xl1500 tn11
7/10
Loading the Driver Parameters
25/11/01 7/10
11. The display of the current parameters set to the specific driver will appear on thescreen.
12. Insert the Scitex XLjet software backup CD into the computer CD drive.
-
8/10/2019 xl1500 tn11
8/10
Loading the Driver Parameters
25/11/01 8/10
13. Press the Import button.
14. Browse the CD (SigmaWin Burning files) and locate the Burning files folder.
15. Choose the relative parameters set.
Note: There are four parameter set files in the Burning files folder. Each file contains
a different set of parameters, according to the specific driver (X, Y, Z, T).
-
8/10/2019 xl1500 tn11
9/10
Loading the Driver Parameters
25/11/01 9/10
16. Check the Select all box to read all the parameters as shown in the picture
below.
17. Press the Write button to load the parameter set to the driver.
-
8/10/2019 xl1500 tn11
10/10
Loading the Driver Parameters
25/11/01 10/10
18. After writing the new values into the driver, reset the system by turning OFF and
ON the relevant driver circuit breaker.
19. After completing the loading procedure, close the SigmaWin application.
20. Disconnect both ends of the JET 110 cable from the driver and the computer.
21. Connect the Com cable to the Com1 connector located in the computers rear
side (see the picture in step 2).
22. Close the Scitex XLjet left and right covers.
23. Open the Scitex XLjet application.
24. The procedure is complete.
On