Onyx I-RIP TrainingHP Scitex XL1500
Course Overview
1. General Introduction
2. DTP
3. Onyx PosterShop RIP
4. Media Manager
Module 1 – General Introduction
Onyx I-RIP TrainingHP Scitex XL1500
Software Configuration
DTP Machine SoftwareOnyx I-RIP
Mac/PC RIP Station HP Scitex XL1500
Module 2 – System Configuration
Onyx I-RIP Training
Module Contents
HP Scitex XL1500
Module 3 – DTP
Subject Slide
DTP Work Flow20File Format – Input21File Format – Output22Macintosh Chooser23CMYK Separation Setup in Photoshop24Ink Coverage 25Closing a PS File Using FreeHand26ICC – International Color Consortium28Insert ICC with PhotoShop29
Onyx I-RIP TrainingHP Scitex XL1500
DTP Work Flow
Module 3 – DTP
Mac/PC Workstation: PhotoShop, Quark etc. M
ach
ine
Ap
pli
cati
on
Onyx I-RIP PS, EPS,JPG, PDF
1-bit Tiff
Onyx I-RIP TrainingHP Scitex XL1500
File Format – Input
PS (PostScript):
A programming and page description language supported by most DTP and graphics applications.
EPS (Encapsulated PostScript):
A version of PostScript file format that includes both a low resolution preview and a high resolution PostScript image description.
PDF (Portable Document Format):
Independent file format (not in program, system or computer).
Module 3 – DTP
Onyx I-RIP TrainingHP Scitex XL1500
File Format – Output
1-bit TIFF
A data file that is processed or output sequentially, bit by bit and line by line. This format has been developed especially for HP IID.
Module 3 – DTP
Onyx I-RIP TrainingHP Scitex XL1500
Macintosh Chooser
Laserwriter 8.4.2.3 and above or AdobePS printer
PPD
Onyx Production House CD
Mac Tools directory in E:/Graphics folder on Prefix RIP server.
Module 3 – DTP
Onyx I-RIP TrainingHP Scitex XL1500
CMYK Separation Setup in PhotoShop
Separation type GCR
Black generation Medium
Black ink limit 100%
Total ink limit 300%
Module 3 – DTP
Onyx I-RIP TrainingHP Scitex XL1500
Ink Coverage
1 2 3
4 5 6
7
Module 3 – DTP
Onyx I-RIP TrainingHP Scitex XL1500
Closing a PS File Using FreeHand
1
2
3
Module 3 – DTP
Onyx I-RIP TrainingHP Scitex XL1500
Closing a PS File Using FreeHand (Cont.)
4
5
Module 3 – DTP
Onyx I-RIP TrainingHP Scitex XL1500
ICC – International Color Consortium
International color standards for all devices
CMM – Color Matching Module
Use HP IID Profile Wizard to create ICC profiles
Input and output ICC profiles are set in Print properties during RIP
Module 3 – DTP
Onyx I-RIP TrainingHP Scitex XL1500
Insert ICC with PhotoShop
1
3
2
Module 3 – DTP
Onyx I-RIP Training
Module Contents
HP Scitex XL1500
Module 4 – Onyx I-RIP
Subject Slide
Hardware – Disk Drives31Onyx I-RIP Software32Before Installation33Installation and Configuration35Configuring the Printer38Main Window – Onyx RIP Queue41RIP a File42Opening an Image43Preflight – Printer and Media44Preflight – Previewing and Sizing45Preflight – Tiling46Preflight – Color Correction47
Onyx I-RIP TrainingHP Scitex XL1500
Hardware – Disk Drives
Module 4 – Onyx I-RIP
Removable drive Windows XP Pro server and other programs
C:\ and D:\ (SCSI) 120 GB disk for images
CD drive CD/DVD-ROM reader
Onyx I-RIP TrainingHP Scitex XL1500
Onyx I-RIP Software
Onyx I-RIP Server
Preflight
Media Manager
Step and Repeat
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Before Installation
Production House hardware and software recommended requirements:
Motherboard - 2 USB ports CPU - Intel Pentium IV/AMD Athlon single/dual 3.2 GHz or higher.
A dual processor will increase performance. RAM - Minimum 2 GB per CPU Hard disk - 3 or more SCSI 10000 RPM hard drives of 40 GB
(minimum) each Recommended: 5 SCSI 10000 RPM hard drives of 80-120 GB each
Hard drive space for installation - 100 MB
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Before Installation (Cont.)
Operating system - Windows XP Pro Server 2 Network boards –
• 100 MB BASE-T• 1 GB Ethernet adapter for network connection
It is recommended to use 2 network boards: one for the network connection and another for direct connection to the machine.
Monitor resolution - 1024 × 768 pixels with 16-bit color
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Installation and Configuration
To Install:
1. Make sure you have the Administrator Privilege.
2. Attach the HASP key to the parallel port (or attach the USB key to the USB port).
3. Insert the Onyx I-RIP program CD into the CD drive.
4. Follow the on-screen instructions and click Next.
5. Install the printer.
6. Once completed, restart the computer.
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Installation and Configuration (Cont.)
Choose C:\Onyx Graphics
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Installation and Configuration (Cont.)
Upon completion of the installation procedure, the software will open a list of drivers to install. Choose and installs the HP Scitex XL1500 1bit printer.
In the Onyx I-RIP, you can install several different printers, and work on each one separately with different devices.
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Configuring the Printer
Install the 1-bit printer
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Configuring the Printer (Cont.)
Before printing from the Onyx RIP-Queue, you must first configure each of the installed printers.
To configure your printer:
1. Start Onyx RIP Queue by:
• Selecting Onyx RIP_Queue from the Start menu,
or
• Double clicking the Onyx RIP Queue icon from the Desktop.
The Configure Printer Port dialog appears(when you run the Onyx RIP-Queue for the first time).
2. Select the Print to File port.
3. Configure the media and page size you would like to work with.
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Configuring the Printer (Cont.)
4. Choose Print to File and then configure the output directory.
5. Choose the media.If all media types do not appear initially, they will appear after importing.
1 2
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Main Window – Onyx RIP Queue
Hold
Job
Select the Printer
Preview
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
RIP a File
There are two options to open and RIP a file:
Use the RIP server. From the Hold to the Print area, drag the file. File manipulation is not available in this option.
Open the file with preflight. Manipulate the file, sizing, cropping, color correction etc. Submit the file and the process will start.
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Opening an Image
1. From the File menu on the top left of the Main window select Open.
2. Select the file you want to RIP.
3. Select your printer by clicking from the printer drop-down menu.
4. Select a Quick Set that best represents your workflow.
5. Click Open.
Choose preflight for file editing
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Preflight – Printer and Media
Toolbar
Select a Printer
Select the Media
Select the Mode
Select the Profile
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Preflight – Previewing and Sizing
Size
Orientation
Cropping on Preview
Preview
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Preflight – Tiling
Enables the Printing of Jobs which are larger than the Media.
Default Tile Size
Custom Size
Overlap
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Preflight – Color Correction
Tools which allow alterations in the output color.
Filter
Tools
Saturation
Color Curves
Module 4 – Onyx I-RIP
Onyx I-RIP TrainingHP Scitex XL1500
Preflight – Color Correction (Cont.)
Color Replacement
Module 4 – Onyx Production House RIP
Onyx I-RIP TrainingHP Scitex XL1500
Preflight – Color Correction (Cont.)
Submitting your Work
Number of Copies
Module 4 – Onyx I-RIP
Onyx I-RIP Training
Module Contents
HP Scitex XL1500
Module 5 – Server Configuration
Subject Slide
Printer Configuration53General Settings60Quick Sets Editing61Quick Set Advanced Options63Change Media and Placement71
Onyx I-RIP TrainingHP Scitex XL1500
Printer Configuration
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Printer Configuration (Cont.)
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Printer Configuration (Cont.)
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Printer Configuration (Cont.)
Print To Resolution Specific Folder – every output RIP is sent to its resolution type folder.
Print To Media Specific Folder – every output RIP is sent to its media type folder.
Print To Image Specific Folder – every output RIP is sent to its image name folder.
Rotating alternate tiles – it is possible to rotate automatically only the odd tiles.
Use light ink at 100% color density – This is the amount of light color at 100% dark color.
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Printer Configuration (Cont.)
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Printer Configuration (Cont.)
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Printer Configuration (Cont.)
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
General Settings
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Sets Editing
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Sets Editing (Cont.)
Quick Set Name
Media Configuration
Resolution & Color Management
Advanced Options
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Set Advanced Options
Output
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Set Advanced Options (Cont.)
Tiles
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Set Advanced Options (Cont.)
Marks
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Set Advanced Options (Cont.)
Crop Marks
The Zero-Line Tile Mark option is applied to tiled jobs which have a defined overlap. The crop marks are printed in a crosshair configuration, with each of the 4 segments measuring 1/4”. The inner 1/8” of each segment is white (with neither mark nor image data printed), and the outer 1/8” of each segment is black.
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Set Advanced Options (Cont.)
Postscript File
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Set Advanced Options (Cont.)
Postscript
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Set Advanced Options (Cont.)
Workflow
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Quick Set Advanced Options (Cont.)
Color Correction
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Change Media and Placement
Module 5 – Server Configuration
Onyx I-RIP TrainingHP Scitex XL1500
Printing Modes
Mode Resolution Sqm/hr
Module 6 – HP Scitex XL1500 Application
Onyx I-RIP Training
Module Contents
HP Scitex XL1500
Module 8 – Media Manager
Subject Slide
New Media104Ink Restriction105Calibrating a New Media107Calibration108Linearization111Ink Limit113Add Profiles114Gray Balance115Black Generation116
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu Create new Profile
Edit Profiles
View Media Library
Configure Device
Report and Tools
Calibrate a new media, using a densitometer for the gray level reading.
Import the OML file (media pack, distributed by HP IID).
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu Create new Profile
Edit Profiles
View Media Library
Configure Device
Report and Tools
Calibrate a new media, using a densitometer for the gray level reading.
Import the OML file (media pack, distributed by HP IID).
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Media Manager
Note: First time launching of Media Manager you will need to choose your Densitometer (click Add)
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Media Manager
Choose your Densitometer
Press Next
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Media Manager
Set-up your Densitometer
Press Next
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Media Manager
Set-up your Densitometer
Press Next
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Media Manager
Set-up your Densitometer
Press Finish
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Media Manager
Set-up your Densitometer
Press “Close”
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu- Create Profile
Clone Existing
Create new Profile
Create new Media
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu
Clone Existing
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu
Clone Existing
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu - Create New Media
Create New Media Group
Type Media Group Name
Press Finish
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu - Create New Media
Create New Media
Add Media Name
Press Next
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu - Create New Media
Press Media Options
Check “Use Light Ink at 100% Color Density”
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Quick Menu - Create New Media
Set Correct Values
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Ink Restriction - Simple Mode Tab
Evaluate file and decide on the Dark ink restriction :
Module 8 – Media Manager
Darkinkrestrictions.tif
Restrict Dark Ink by choosing cubes
Press Next (“Set Transition Values”)
Onyx I-RIP TrainingHP Scitex XL1500
Ink Restriction - Advanced Mode Tab
Module 8 – Media Manager
Darkinkrestrictions.tif
Restrict Dark Ink by using the “Set Restrictions” Button
Light Colors should be 70% of Dark colors (E.G. 92X0.7)
Press Next
Onyx I-RIP TrainingHP Scitex XL1500
Ink Restriction - Advaced Mode Tab
Module 8 – Media Manager
Set Transition Values to 7
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Module 8 – Media Manager
Set scale to 180% (Do not use “Copies” as RIP time will be longer and this function is to be done on Press)
Press Print
Note: As the RIP is processing the file a time bar is showing RIP Set Progression to view this use the scroll bar
Press Next
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Print and Read Color Swatch :
Module 8 – Media Manager
If needed Press Back and adjust needed parameters
Press “Print Swatch”
Note: As the RIP is processing the file a time bar is showing RIP Set Progression to view this use the scroll bar
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Read Color Swatch Calibration Data:
Module 8 – Media Manager
Press Setup
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Read Color Swatch Settings :
Module 8 – Media Manager
I-One and File settings
Number of Patches per Ink
Press OK
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Read Color Swatch :
Module 8 – Media Manager
Press Print
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Print and Read Color Swatch :
Module 8 – Media Manager
Press Read Swatch
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Print and Read Color Swatch :
Module 8 – Media Manager
Set the correct settings in Linearization Options
Calibrate I-One on white Spot
Calibrate I-One on Paper
Start to read Patches
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Print and Read Color Swatch :
Module 8 – Media Manager
Calibrate I-One on white Spot
Calibrate I-One on Paper
Start to read Patches
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Read Color Swatch :
Module 8 – Media Manager
Press OK
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Read Color Swatch :
Module 8 – Media Manager
Press Build
In case of values that are misread you will receive the “Invalid Reading (s) Screen choose Auto, Press OK
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Print and Read Color Swatch :
Module 8 – Media Manager
Press Next
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Target Density's :
Module 8 – Media Manager
Choose “Basic Density Curves!”
Press Build Table
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Target Density's :
Module 8 – Media Manager
Press Next
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Print and Build Ink Limit Table :
Module 8 – Media Manager
Press Next
Onyx I-RIP TrainingHP Scitex XL1500
Print Test Image (No Linearization)
Print and Build Ink Limit Table :
Module 8 – Media Manager
Press Next
Press Finish
Onyx I-RIP TrainingHP Scitex XL1500
Ink Restriction (Cont.)
Transition Control
Ink Restrictions
Ink Configuration
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Calibrating a New Media
1. Choose the New Media icon.
2. Set the media a name and mode.
3. Select Color Setup, and choose the 6-color mode.
4. Enter ink restriction values:
i. Click Ink Restrictions.
ii. Select the resolution for which you want to set restrictions.
iii. Select the ink level that you want to restrict.
iv. Click Set Restriction.
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Calibration
Media Configuration Swatch Print Option
Dot Pattern and Resolution(Stochastic)
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Calibration (Cont.)
Device (i1 recommended) Device configuration
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Calibration (Cont.)
Device List Swatch Steps
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Linearization
Print the linearization (recommended 15 steps) file and measure it with a densitometer (EYE 1).
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Linearization (Cont.)
Set the N-factor for each color recommendations.
Measurement Tweak
N-Factor
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Ink Limit
Examine the ink limit swatch and choose the desired value.
Limit between 3-4
Module 8 – Media Manager
Onyx I-RIP TrainingHP Scitex XL1500
Add Profiles
Add New Profile