XHnotion Frl catalogue 2017
-
Upload
xhnotion-pneumatic -
Category
Sales
-
view
99 -
download
0
Transcript of XHnotion Frl catalogue 2017
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-2
C
1. D series is equivalent to Festo air preparation.
2. Increase the service life of pneumatic components and system by mixing the sizes for FRL unit, you can enjoy optimum flow rates with smaller sizes and lower costs.
3. Compatible with pressure switches, soft start valve and safety pressure relief valve.
Features
How to Order
D 200 D01
Model
D Type
Type
C: Three combinationor Two combinationFR: Filter&RegulatorR: Air regulatorL: Air LubricatorF: Air filter
Body Size
100200400600
Two combination101201401601
Port Size
M5: M5X0.801: G1/8"02: G1/4"03: G3/8"04: G1/2"06: G3/4"08: 1"
Drain Type
Blank: Manual drainD: Auto-drain
Symbol
Symbol
D Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-3
DC100-600 Series
Symbol
Type DC100-M5,01 DC200-01,02,03 DC400-03,04,06 DC600-06,08
Port Size M5•1/8" 1/8"•1/4"•3/8" 3/8"•1/2"•3/4" 3/4"•1"
Gauge Thread (G) M5 1/8" 1/4"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85 0.15-1.2
Max.Flow Rate (L/min) 500 1700 3500 11500
Ambient Temperture (℃ ) -10-60
Filter Precision 5um or 40um
Structure Overflow Type
Guard cup - • • •
Type DC101-M5,01 DC210-01,02,03 DC410-03,04,06 DC601-06,08
Port Size M5•1/8" 1/8"•1/4"•3/8" 3/8"•1/2"•3/4" 3/4"•1"
Gauge Thread (G) M5 1/8" 1/4"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85 0.15-1.2
Max.Flow Rate (L/min) 500 1700 3500 11500
Ambient Temperture (℃ ) -10-60
Filter Precision 5um or 40um
Structure Overflow type
Guard cup - • • •
DC101-601 Series
Symbol
DR100-600 Series
Symbol
Type DR100-M5,01 DR200-01,02,03 DR400-03,04,06 DR600-06,08
Port Size M5•1/8" 1/8"•1/4"•3/8" 3/8"•1/2"•3/4" 3/4"•1"
Gauge Thread (G) M5 1/8" 1/4"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85 0.15-1.2
Max.Flow Rate (L/min) 500 1700 3500 11500
Ambient Temperture (℃ ) -10-60
D Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-4
Type DL100-M5,01 DL200-01,02,03 DL400-03,04,06 DL600-06,08
Port Size M5•1/8" 1/8"•1/4"•3/8" 3/8"•1/2"•3/4" 3/4"•1"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85 0.15-1.2
Max.Flow Rate (L/min) 500 1700 3500 11500
Ambient Temperture (℃ ) -10-60
Structure Overflow Type
Guard Cup - • • •
DL100-600 Series
Symbol
DFR100-600 Series
Symbol
Type DFR100-M5,01 DFR200-01,02,03
DFR400-03,04,06 DFR600-06,08
Port Size M5•1/8" 1/8"•1/4"•3/8" 3/8"•1/2"•3/4" 3/4"•1"
Gauge Thread (G) M5 1/8" 1/4"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85 0.15-1.2
Max.Flow Rate (L/min) 500 1700 3500 11500
Ambient Temperture (℃ ) -10-60
Filter Precision 5um or 40um
Structure Overflow Type
Guard cup - • • •
DF100-600 Series
Symbol
Type DF100-M5,01 DF200-01,02,03 DF400-03,04,06 DF600-06,08
Port Size M5•1/8" 1/8"•1/4"•3/8" 3/8"•1/2"•3/4" 3/4"•1"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85 0.15-1.2
Max.Flow Rate (L/min) 500 1700 3500 11500
Ambient Temperture (℃ ) -10-60
Filter Precision 5um or 40um
Structure Overflow Type
Guard cup - • • •
D Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-5
Type DFR100-M5,01 DFR200-01,02,03
DFR400-03,04,06 DFR600-06,08
Port Size M5•1/8" 1/8"•1/4"•3/8" 3/8"•1/2"•3/4" 3/4"•1"
Gauge Thread (G) M5 1/8" 1/4"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85 0.15-1.2
Max.Flow Rate (L/min) 500 1700 3500 11500
Ambient Temperture (℃ ) -10-60
Filter Precision 5um or 40um
Structure Overflow Type
Guard cup - • • •
DRB Series
Type DRB200-01,02,03 DRB400-03,04,06
Port Size 1/8"•1/4"•3/8" 3/8"•1/2"•3/4"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85
Max.Flow Rate (L/min) 1700 3500
Ambient Temperture (℃ ) -10-60
Symbol
DZ Series Symbol
Type DZ200-01,02,03 DZ400-03,04,06 DZ600-06,08
Port Size 1/8"•1/4"•3/8" 3/8"•1/1"•3/4" 3/4"•1"
Fluid Compressed Air
Operating Pressure Range (MPa) 0.15-0.85
Ambient Temperture (℃ ) -5-60
Acting Type Manual
Valve Type 2 Way 3 Position
Operating Angle 90°
Exhaust Port Size 1/8" 3/8" 1/2"
Suitable FRL Type DC200-01,02,03 DC400-03,04,06 DC600-06,08
FeaturesThe regulator for an integrated installation, can provide a variety of different pressure gas source, the front and rear sides of each one has a output connection.
Features1. This valve can be used as manual 3/2 valve.2. When the machinery is maintained and serviced, the valve for remaining pressure shall be used to eliminate the remaining pressuren when the air source is cut off.
D Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-6
FeaturesHigh Pressure Regulator: Compressed air can be adjusted from 4MPa to 3MPa and kept steady-going.
High Pressure Filter: It is suitable to filter the solid and fluent impurity the compressed air blew the 4MPa.
How to Order
Model
Regulator
High pressure
Q
Port size:
02: G1/4"03: G3/8"04: G1/2"06: G3/4"08: G1"
H 04
Type
TY: RegulatorSL: filterFR: filter Regulator
High pressure Regulator Type QTYH-02 QTYH-03 QTYH-04 QTYH-06 QTYH-08
Port size (G) 1/4" 3/8" 1/2" 3/4" 1"
Fluid Compressed Air
Operating Pressure Range (Mpa) 0.05-3
Max. Working Pressure (Mpa) 4
Ambient Temperature (°C) -10―70
Symbol
High pressure Filter Type QSLH-02 QSLH-03 QSLH-04 QSLH-06 QSLH-08
Port Size (G) 1/4" 3/8" 1/2" 3/4" 1"
Fluid Compressed Air
Operating Pressure Range (Mpa) 0.05-3
Max. Working Pressure (Mpa) 4
Filter Precision 5um or 40um
Ambient Temperature (°C) -10―70
Symbol
High pressure Filter Regluator Type QFRH-02 QFRH-03 QFRH-04 QFRH-06 QFRH-08
Port Size (G) 1/4" 3/8" 1/2" 3/4" 1"
Fluid Compressed Air
Operating Pressure Range (Mpa) 0.05-3
Max. Working Pressure (Mpa) 4
Ambient Temperature (°C) ‐10―70
Symbol
Q Series
TY
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-7
HM Series
Provided with a controlled air escape which is able to achieve highly accurate pressure adjustment. High stability with low load losses and big flow rate. Downstream overpressure quickly eliminated.
How to Order
Model HMRP2000-01 HMRP2000-02 HMR2000-01 HMR2000-02
Operating Fluid Filtered Compressed Air
Port Size G1/8" G1/4" G1/8" G1/4"
Gauge Port Size G1/8"
*Filter Precision 25u
Regulating Pressure Range 0.05~0.8MPa
Highest Working Pressure 1.6Mpa
Ambient Fluid Temperature 5-50℃
Flow Rate 450L/min
Weight 160g
R
Series P: Always RelievingBlank: Relieving
HM
Port size:
01: G1/8"02: G1/4"
P 2000
Type
R: Regulator
01
Size
Direct Acting Precision Micro RegulatorOverall Dimension Drawing
*5/50um availlable in addition
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-8
Feature:
Symbol
•Compact and light weight.
•Flow rate is 20% higher than that of traditional ones(Max. Flow Rate:1 L/min).
•Exhaust rate is 5 times than that of traditional ones.
•Precise pressure setting.
•Easy for mounting, capable of mounting individually, together with modular filter combination and mounting on panel.
•Piloted exhaust and main exhaust are separated.
How to Order
Precision Regulator
IR 02
Precision Regulator
Type IR3000-02,03,04 IR3010-02,03,04 IR3020-02,03,04
Port Size (G) 02: G1/4", 03: G3/8", 04: G1/2"
Fluid Compressed Air
Pressure Range (Mpa) 0.05-0.2 0.05-0.4 0.05-0.8
Ambient Temperature (°C) -10-60
Sensitivity 0.2%
Repeated Precision ±5%
Rated Flow (L/min) 1100
Port size:
02: G1/4" 03: G3/8" 04: G1/2"
Settled pressure
3000 3010 3020
3000
IR Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-9
C
1. A series is equvalent of SMC FRL.
2. The series carry FRL, Air filter, Air regulator and Air lubricator.
Features
How to Order
A 2000 D01
Model
A XHAHNA
Type
C: Three combinationor Two combinationW: Filter&RegulatorR: Air regulatorL: Air LubricatorF: Air filter
Body Size
100020002500300040005000
Two combination10102010301040105010
Port Size
M5: M5X0.801: G1/8"02: G1/4"03: G3/8"04: G1/2"06: G3/4"10: 1"
Drain Type
Blank: Semi-automaticD: Automatic
Symbol
G
Gauge installation
Blank: The old General Circular GaugeE: Embedded Square GaugeG: The new General Circular Gauge
A Series
3. Modular design allows for space saving and easy installation.
4. Compatible with pressure switches, soft start valve and safety pressure relief valve.
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-10
*5,50 um available in addition
*Under the circumstance that the supply pressure is 0.7MPa(7.1kgf/cm²) and set pressure is 0.5MPa(5.1kgf/cm) BSPT and NPT port size are available
AC1000-5000 Series
Ensured Pressure Resistance 1.5MPa(15kgf/cm²)
Highest Working Pressure 1.0MPa(10kgf/cm²)
Ambient and Fluid Temperature 5-60 Celsius Degree
*Filter Precision 25um
Recommended Oil Use Turbine No.1 Oil ISOCG32
Container Material Polycarbonate
Protective Cover 1000-2000(Not Available) 2500-5000(Available)
Pressure Regulating Range0.05-0.7MPa(0.5-7kgf/cm²)
0.05-0.85MPa(0.5-8.5kgf/cm²)
Valve Type With Overflow
Model
Assembly Specification
BracketFilter Regulator Lubricator Flow Rate*
(L/min)SCFM*
Cubic Feet /min Port Size Weight(Kg)
AC1000-M5 AF1000 AR1000 AL1000 90 3.2 M5 0.26 Y10L
AC2000-01AF2000 AR2000 AL2000 500 17.7
1/8"0.74 Y20L
AC2000-02 1/4"
AC2500-02AF3000 AR2500 AL3000 1500 53
1/4"1.04 Y30L
AC2500--03 3/8"
AC3000-02AF3000 AR3000 AL3000 2000 71
1/4"1.18 Y30L
AC3000-03 3/8"
AC4000-03AF4000 AR 000 AL4000 4000 141
3/8"2.14 Y40L
AC4000-04 1/2"
AC4000-06 AF 4000-06 AR4000-06 AL4000-06 4500 159 3/4" 2.47 Y50L
AC5000-06AF 5000 AR 5000 AL 5000 5000 177
3/4"3.82 Y60L
AC5000-10 1"
Symbol
A Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-11
*Under the circumstance that the supply pressure is 0.7MPa(7.1kgf/cm²) and set pressure is 0.5MPa(5.1kgf/cm) BSPT and NPT port size are available
AC1010-5010 Series Symbol
ModelAssembly Specification
BracketFilter Lubricator Flow Rate*
(L/min)SCFM*
Cubic Feet /min Port Size Weight(Kg)
AC1010-M5 AW1000 AL 1000 90 3.2 M5 0.22 Y10T
AC2010-01AW2000 AL 2000 500 17.7
1/8"0.66 Y20T
AC2010-02 1/4"AC3010-02
AW3000 AL3000 1700 601/4"
0.98 Y30TAC3010--03 3/8"
AC4010-03AW4000 AL4000 3000 106
3/8"1.93 Y40T
AC4010-04 1/2"
AC4010-06 AW4000-06 AL4000-06 3000 106 3/4" 1.99 Y50T
AC5010-06AW5000 AL5000 4000 141
3/4"3.20 Y60T
AC5010-10 1
AF1000-5000 Series Symbol
Model
Specification
Bracket Drain Function Auto Drain ModelFlow Rate* (L/min)
SCFM* Cubic Feet /min Port Size Bowl Capacity
(cm³) Weight(Kg)
AF1000-M5 110 3.9 M5 4 0.07 -
Manual Drain
-
AF2000-01750 26.5
1/8"15 0.19 B240
AF2000-01D
AF2000-02 1/4" AF2000-02D
AF3000-021500 53
1/4"20 0.29 B340
a.AirShutoff Drain
b.Manual Drain
AF3000-02D
AF3000--03 3/8" AF3000--03D
AF4000-034000 141
3/8"45 0.55 B440
AF4000-03D
AF4000-04 1/2" AF4000-04D
AF4000-06 6000 212 3/4" 45 0.58 B540 AF4000-06D
AF5000-067000 247 3/4"
130 1.08 B640AF5000-06D
AF5000-10 1 AF5000-10D
A Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-12
AR1000-5000 Series Symbol
ModelSpecification
BracketFlow Rate* (L/min)
Pressure Gauge Size (G) Port Size Weight(Kg)
AR1000-M5 110 1/16" M5 0.08 B120
AR2000-01550 1/8"
1/8"0.27 B220
AR2000-02 1/4"
AR2500-022000 1/8"
1/4"0.27 B220
AR2500-03 3/8"
AR3000-022500 1/8"
1/4"0.41 B320
AR3000--03 3/8"
AR4000-036000 1/4"
3/8"0.84
B420
AR4000-04 1/2"
AR4000-06 6000 1/4" 3/4" 0.94
AR5000-068000 1/4“
3/4"1.19
AR5000-10 1
AL1000-5000 Series Symbol
Model
Specification
BracketMinimal Flow of Oil Drop(L/min)
Flow Rate* (L/min)
SCFM* Cubic Feet /min Port Size Bowl Capacity
(cm³) Weight(Kg)
AL1000-M5 4 95 3.4 M5 7 0.07 -
AL2000-0115 800 28.3
1/8"25 0.22 B240
AL2000-02 1/4"
AL3000-02 301700 60
1/4"50 0.30 B340
AL3000--03 40 3/8"
AL4000-03 405000 177
3/8"130 0.56 B440
AL4000-04 50 1/2"
AL4000-06 50 6300 222 3/4" 130 0.58 B540
AL5000-06190 7000 247
3/4"130 1.08 B640
AL5000-10 1
A SeriesA Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-13
AW1000-5000 Series
Specification
Model
Specification
Bracket Drain Function Auto Drain ModelFlow Rate* (L/min)
SCFM* Cubic Feet /
minPort Size
Pressure Gauge size
(G)Weight(Kg)
AW1000-M5 110 3.5 M5 1/16 0.09 B120
Manual Drain
-
AW2000-01550 19.4
1/8"1/8 0.36 B220
AW2000-01D
AW2000-02 1/4" AW2000-02D
AW3000-022000 70.6
1/4"1/8 0.56 B320
a.Air Shutoff Drain
b.Manual Drain
AW3000-02D
AW3000--03 3/8" AW3000--03D
AW4000-034000 141
3/8"1/4 1.15
B420
AW4000-03D
AW4000-04 1/2" AW4000-04D
AW4000-06 4500 159 3/4" 1/4 1.21 AW4000-06D
AW5000-065500 194
3/4"1/4 1.70
AW5000-06D
AW5000-10 1 AW5000-10D
Symbol
A Series
ZDFS Auto Discharger Range of Application This product is installed at the bottom of water cup for auto dischargers, air filters and air filter regulators and can auto discharge the condense water gathered in the water cup.
FeatureAuto draimer Manual DrainAir Shutoff DrainThe water cup is provide with metal protective cover
Technical RequirementWorking medium: compressed airAmbient and media temperature:5-60 celsius degree.Operaating Pressure:0.15-1.00MPa
Point for Attention When using , the drainer should be installed vertically the drain port facing duwn.
A Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-14
Symbol
HVHS Venting Safety Lock-out Valve
A
P R
It is easy to be maintained because it can realse the pressure of the hypo-pressure side when it is working. It can ensure the safty of the maintenance man because of the lockup function.
Advantage
HAD402 Series Symbol Purpose
This product often applies to auto remove the seeper at the lower places of piping, frozen type air drying machine, oil separtator, air storage tanks and the bottom of various air filters. It can be installed in the places inconvenient for manual discharge of sewage, such as higher, lower and narrow places, especially there is large consumption of air or frequent water drains. It can prevent the compressed air being re-polluted by condense water resulting from neglect of manual drain.
Model HAD402-02 HAD402-03 HAD402-04
Ensured Pressure Resistance 1.5MPa
Operating Pressure 0.15-1.00MPa
Ambient and Fluid Temperature 5-60 Celsius Degree
Port Size G1/4" G3/8" G1/2"
Drain Port Size R1/8
Drain Status Normal Open Type
Working Medium Compressed air
Auto draimer Manual DrainAir Shutoff DrainThe water cup is provide with metal protective cover
Point for Attention When using , the drainer should be installed vertically the drain port facing down.
Features
A Series
Model Port Size Vent Size
HVHS2000-01-X1 G1/8" G1/8"
HVHS2000-02-X1 G1/4" G1/8"
HVHS3000-02-X1 G1/4" G1/4"
HVHS3000-03-X1 G3/8" G1/4"
HVHS4000-03-X1 G3/8" G3/8"
HVHS4000-04-X1 G1/2" G3/8"
HVHS5000-10-X1 G1" G3/8"
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-15
HACE2000-5000 Series
Features
Symbol
HACE2010-5010 Series
Symbol
HARE2000-5000 Series
Symbol
HAWE2000-5000 Series
Symbol
This product has been improved in installation of pressure gauge and overflow structure, making the products more convenient, more sensitive overflow. Push in fittings at the filter bottom can connect one tube to drain water to other place in order to protect environment.
HAE Series
Model Port Size Vent Size
HVHS2000-01-X1 G1/8" G1/8"
HVHS2000-02-X1 G1/4" G1/8"
HVHS3000-02-X1 G1/4" G1/4"
HVHS3000-03-X1 G3/8" G1/4"
HVHS4000-03-X1 G3/8" G3/8"
HVHS4000-04-X1 G1/2" G3/8"
HVHS5000-10-X1 G1" G3/8"
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-16
Large Flow Series
HAF Series
HAR Series
HAL Series
Model HAF800-14 HAF900-20 HAF1200-30
Operating Fluid Air
Port Size G1-1/2" G2" G3"
*Filter Precision 25u
Ensured Pressure Resistance 1.5MPa
Ambient Fluid Temperature 5-60℃
Rating Flow 12000L/min 20000L/min
Guard Cup • • •
Model HAR825-14 HAR925-20 HAR1225-30
Operating Fluid Air
Port Size G1-1/2" G2" G3"
Ensured Pressure Resistance 1.5MPa
Ambient Fluid Temperature 5-60℃
Rating Flow 12000L/min 20000L/min
Adjustable Pressure Range 0.05~0.85Mpa
Guard Cup • • •
Model HAL800-14 HAL900-20 HAL1200-30
Operating Fluid Air
Port Size G1-1/2" G2" G3"
Ensured Pressure Resistance 1.5MPa
Ambient Fluid Temperature 5-60℃
Min. Flow of Oil Drop 650L/min 1800L/min
Guard Cup • • •
Symbol
Symbol
Symbol
*5/50um availlable in addition
FeatureLarge flow, remove quickly compressed air's oil, water, solids and other pollutants, to move the function of the downstream dryer, extending the service life of precision filter.
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-17
Model HAF800-14 HAF900-20 HAF1200-30
Operating Fluid Air
Port Size G1-1/2" G2" G3"
*Filter Precision 25u
Ensured Pressure Resistance 1.5MPa
Ambient Fluid Temperature 5-60℃
Rating Flow 12000L/min 20000L/min
Guard Cup • • •
Model HAR825-14 HAR925-20 HAR1225-30
Operating Fluid Air
Port Size G1-1/2" G2" G3"
Ensured Pressure Resistance 1.5MPa
Ambient Fluid Temperature 5-60℃
Rating Flow 12000L/min 20000L/min
Adjustable Pressure Range 0.05~0.85Mpa
Guard Cup • • •
Model HAL800-14 HAL900-20 HAL1200-30
Operating Fluid Air
Port Size G1-1/2" G2" G3"
Ensured Pressure Resistance 1.5MPa
Ambient Fluid Temperature 5-60℃
Min. Flow of Oil Drop 650L/min 1800L/min
Guard Cup • • •
How to Order
350
Series Body Size
350: G1/2" 550: G1" 650: G1-1/2"
AFF
Port Size
04: G1/2"10: G1"14: G1-1/2"
Drain Type
A: Auto drain
04 D
A/B Series
Main Line Filter
Model AFF350-04 AFF550-10 AFF650-14
Operating Fluid Filtered Compressed Air
Port Size G1/2" G1" G1-1/2"
*Filter Precision 3u(Removai 95%)
Working Pressure 0.05Mpa~1.6Mpa
Ambient Fluid Temperature -5-60℃
Flow Rate 1500L/min 3700L/min 6000L/min
Element Life At Pressure Differential of 0.1MpaSymbol
AFF Series
*5/50um availlable in addition
This is a differential balanced valve automatically opens the air port fully when the downstream pressure is about 50% of the upstream pressure. Without a pilot, the upstream air flows downstream through the regulation needle. When an external or pneumatic solenoid signal is generated, the valve opens the main ports to creat full flow. It doesn't relieve the downstream circuit.
Slow Start Valve
Symbol
Model HAV2000 HAV3000 HAV4000 HAV5000
Port Size (G) 1/4" 3/8" 1/2" 3/4"
Operating Pressure Range (Mpa) 0.3~1.0Mpa
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-18
20--Type bracket
40-Type bracket
L-Type Bracket
Pressure Gauge
Model
B120
B220
B320
B420
Used for AR, AW series
Used for AF, AL seriesModel
B240
B340
B440
B540
B640
L-Type Bracket Spacer with L-type bracket
B110L Y10L
B210L Y20L
B310L Y30L
B410L Y40L
B510L Y50L
B610L Y60L
Used for AC series
Assembling Accessories
T-Type Spacer Used for AC series
Model Port Size G
Y21-01 G1/8"
Y21-02 G1/4"
Y31-01 G1/8"
Y31-02 G1/4"
Y41-02 G1/4"
Y41-03 G3/8"
Y61-03 G3/8"
Y61-04 G1/2"
PG-01
PG-02
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-19
Pressure Gauge
Features Symbol
1. Various combinations available
2. Port sizes: M5 to 1"
3. Modular design allows for space saving and easy installation
4. Compatible with pressure switches, soft start valve and safety pressure relief valve.
How to Order
C
Model
A Series
B Series
Type
C: Three combinationFC: Two combinationFR: Filter&RegulatorR: Air regulatorL: Air LubricatorF: Air filter
A
Port Size
1500: PT1/8"2000: PT1/4"2000: PT1/4"3000: PT3/8"4000: PT1/2"
Drain Type
M: Manual DrainA: AutomaticBlank: Pressure Differential Drain
2000 M L
Pressure Regulating Range
Blank: Standard(0.85MPa)L: Low Presuure(04MPa)
A/B Series
A/B Series
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-20
AR、BR Series Model AR1500 AR2000 BR2000 BR3000 BR4000
Operating Fluid Air
Port Size G1/8" G1/4" G1/4" G3/8" G1/2"
Pressure Regulating Range
0.05-0.85MPa(7-12psi)
Ensured Pressure Resistance 1.5MPa(213psi)
Operating Temperature 5-60℃
Weight 200g 230g
AC、BC Series
Symbol
Model AC1500 AC2000 BC2000 BC3000 BC4000
Operating Fluid Air
Port Size G1/8" G1/4" G1/4" G3/8" G1/2"
*Filter Precision 40u
Pressure Regulating Range 0.05-0.85MPa(7-12psi)
Ensured Pressure Resistance 1.5MPa(213psi)
Operating Temperature 5-60℃
Recommended Oil Use ISO VG 32 or Same Grade Oil
Weight 700g 900g
Composed Elements
Filter AF1500 AF2000 BF2000 BF3000 BF4000
Regulator AR1500 AR2000 BR2000 BR3000 BR4000
Lubricator AL1500 AL2000 BL2000 BL3000 BL4000
Guard Cup • • - - -
AFC、BFC Series
Symbol
Model AFC1500 AFC2000 BFC2000 BFC3000 BFC4000
Operating Fluid Air
Port Size G1/8" G1/4" G1/4" G3/8" G1/2"
*Filter Precision 40u
Pressure Regulating Range 0.05-0.85MPa(7-12psi)
Ensured Pressure Resistance 1.5MPa(213psi)
Operating Temperature 5-60℃
Recommended Oil Use ISO VG 32 or Same Grade Oil
Weight 500g 700g
Composed
ElementsFilter AFR1500 AFR2000 BFR2000 BFR3000 BFR4000
Regulator AL1500 AL2000 BL2000 BL3000 BL4000
Guard Cup • • - - -
A/B Series
Symbol
*5/50um availlable in addition
*5/50um availlable in addition
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
3
FRL Unit
7-21
AL、BL Series
Symbol
Model AL1500 AL2000 BL2000 BL3000 BL4000
Operating Fluid Air
Port Size G1/8" G1/4" G1/4" G3/8" G1/2"
Ensured Pressure Resistance 1.5MPa(213Psi)
Operating Temperature 5-60℃
Recommended Oil Use ISO VG 32 or Same Grade Oil
Weight 170g 250g
Guard Cup • • - - -
Model AC1500 AC2000 BC2000 BC3000 BC4000
Operating Fluid Air
Port Size G1/8" G1/4" G1/4" G3/8" G1/2"
*Filter Precision 40u
Pressure Regulating Range 0.05-0.85MPa(7-12psi)
Ensured Pressure Resistance 1.5MPa(213psi)
Operating Temperature 5-60℃
Recommended Oil Use ISO VG 32 or Same Grade Oil
Weight 700g 900g
Composed Elements
Filter AF1500 AF2000 BF2000 BF3000 BF4000
Regulator AR1500 AR2000 BR2000 BR3000 BR4000
Lubricator AL1500 AL2000 BL2000 BL3000 BL4000
Guard Cup • • - - -
A/B Series
AFR、BFR Series
Symbol
AF、BF Series
Symbol
Model AFR1500 AFR2000 BFR2000 BFR3000 BFR4000
Operating Fluid Air
Port Size G1/8" G1/4" G1/4" G3/8" G1/2"
*Filter Precision 40u
Pressure Regulating Range
0.05-0.85MPa(7-12psi)
Ensured Pressure Resistance 1.5MPa(213psi)
Operating Temperature 5-60℃
Weight 260g 400g
Guard Cup • • - - -
Model AF1500 AF2000 BF2000 BF3000 BF4000
Operating Fluid Air
Port Size G1/8" G1/4" G1/4" G3/8" G1/2"
*Filter Precision 40u
Ensured Pressure Resistance 1.5MPa(213Psi)
Operating Temperature 5-60℃
Weight 140g 330g
Guard Cup • • - - -
*5/50um availlable in addition
*5/50um availlable in addition
+86 574 82823826 Fax +86 574 82823826 [email protected] Web: www.xhnotion.com
FRL Unit
7-22
398 1000-5000 Series 399 1010-5010 Series 396 1000-5000 Series
395 1000-5000 Series 394 1000-5000 Series 394 1000-5000 Series
Model 39 Series
Working Medium Filtered and Compressed Air
Pressure Regulating Range 0.05~0.85 Mpa
Ambient Temperature 5-60 ℃
Filter 5um, 40um
1. 39 series is equivalent to Herion Air Preparation.
2. Port sizes: M5 to 1"
3. Modular design allows for space saving and easy installation
4. Compatible with pressure switches, soft start valve and safety pressure relief valve.
39 Series
Features
39 Series