Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To...

15
www.T5- Retrofit.com Conserving Resources for the Future… Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1

Transcript of Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To...

Page 1: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

www.T5-Retrofit.comConserving Resources for the Future…

Today.

T5 Lighting Retrofit SolutionsTo replace outdated T12 and T8

Fluorescent lighting

1

Page 2: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

T5 Adapters2

Page 3: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

T5 Retrofit Lighting Advantages

Eliminates replacing and rewiring of ballast FOREVER

Brighter and more natural light that benefits employees, guests, patients, students, and visitors to your business

Reduces your lighting cost up to 79% and save on re-lamping.

T5 bulbs burn at approximately 95% of their lumens for the life of the bulb compared to 50% degradation for T12s and 25% for T8s. No discoloring or dimming over the life of the bulb

The efficiency of T5 adapters extends the life expectancy of the T5 lamps/bulbs

3

Page 4: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

Product warranty - 5 years /60,000 hours (25 year) life expectancy on adapter

T5 allows for de-lamping of fixtures, increasing your savings while producing more natural light

Flexibility; retrofit your whole facility or just one floor/building at a time

The T5 bulbs burn cooler thus reducing your heat load, air conditioning cost, and power usage considerably

Utility rebates and tax incentives are available for T5 retrofits

4

T5 Retrofit Lighting Advantages (Continued)

Page 5: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

Lighting consumes the most energy: Represents between 30% and 55% of your total

power consumption.

5

Page 6: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

Chart: 100 fixtures x 12 cents per kWh x 12 hours a day

T5T5 T8T8 T12T12

BulbsBulbs 2x28 watt2x28 watt 4x32 watt4x32 watt 4x34 watt4x34 watt

Total WattsTotal Watts 5656WattsWatts

128 128 WattsWatts

136136WattsWatts

AnnualAnnualCostCost $1,935.36$1,935.36 $4,423.68$4,423.68 $4,700.16$4,700.16

6

Page 7: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

Retrofit Percentage Savings5 Days a week-10 hrs a day

7

ExistingExisting RetrofitRetrofit %Savings%Savings

T12/34w(4) bulbT12/34w(4) bulb T5(28w) 2bulbsT5(28w) 2bulbs 65%65%

T8/32w (4) bulbT8/32w (4) bulb T5(28w) 2 bulbT5(28w) 2 bulb 56%56%

Actual percentage may vary slightly with days and hours lights are on. The longer they burn, the larger the savings.

Page 8: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

8

T5Adapter for 8 foot retrofit

T5 Adapter with and without

reflector

Page 9: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

The Retro-Fit takes only minutes-removing the existing lamps and ballast -then straight wiring

the tombstones and installing the T5 Adapters and T5 lamps.

9

Pic of open fixture and ballast

Page 10: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

10

Page 11: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

11

2x2foot retrofit kit

Page 12: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

12

Page 13: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

13

Page 14: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

14

Page 15: Www.T5-Retrofit.com Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.

15

Commercial Lighting Retrofit Specialists

770-624-7336Conserving Resources For The Future…Today