Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.
-
Upload
valerie-mosley -
Category
Documents
-
view
226 -
download
1
Transcript of Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.
![Page 1: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/1.jpg)
WelcomeIQAC at DHVI
![Page 2: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/2.jpg)
CD4 Immunophenotyping for HIV Monitoring
Flow Cytometry
![Page 3: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/3.jpg)
3
Introduction
Absolute CD4 T-lymphocyte counts are used to evaluate the immune status of patients with the human immunodeficiency virus (HIV).
CD4 antigen is the receptor for HIV. The absolute number of CD4 T lymphocytes is closely associated with HIV progression.
![Page 4: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/4.jpg)
4
Flow Cytometry
Laser based high speed electronic cell analyzer
Fluorescent conjugated monoclonal antibodies
Analyze surface (and cytoplasmic) cellular antigens.
Flow rates 500 –700 cells /second
![Page 5: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/5.jpg)
5
Flow Cytometry What Can a Flow Cytometer Tell
Us About a Cell? Its relative size (Forward Scatter-
FSC) Its relative granularity or internal
complexity (Side Scatter-SSC) Its relative fluorescence intensity
(FL1,FL2,FL3, and FL4)
![Page 6: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/6.jpg)
6
Light Scatter Properties
![Page 7: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/7.jpg)
7
Blood Cells
![Page 8: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/8.jpg)
8
Flow Light Scatter Pattern
![Page 9: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/9.jpg)
9
Fluorescence
![Page 10: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/10.jpg)
10
Fluorescence Emission
![Page 11: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/11.jpg)
11
Fluorescence Intensity
![Page 12: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/12.jpg)
12
2-parameter Dot Plot
![Page 13: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/13.jpg)
13
Flow Cytometry System
Fluidics To introduce and focus cells for analysis.
Optics To generate and collect light signals.
Electronics To convert optical signals to digital electronic
signals for computer analysis.
![Page 14: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/14.jpg)
14
Fluidics
![Page 15: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/15.jpg)
15
Injector Tip
FluorescenceFluorescencesignalssignals
Focused laserFocused laserbeambeam
Sheath fluid
Purdue University Cytometry Laboratories
Flow Cell
![Page 16: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/16.jpg)
16
Sample Flow
![Page 17: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/17.jpg)
17
Optics
Excitation optics Laser(s) Lenses to shape and focus the laser beam
Collection optics A collection lens to collect light emitted from
the particle-laser beam interaction A system of optical mirrors and filters to
route specified wavelengths of the collected light to designated optical detectors.
![Page 18: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/18.jpg)
18
Forward Angle Light Scatter
FALS Sensor
Laser
Purdue University Cytometry Laboratories
![Page 19: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/19.jpg)
19
90 Degree Light Scatter
FALS Sensor
90LS Sensor
Laser
Purdue University Cytometry Laboratories
![Page 20: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/20.jpg)
20
Laser
Fluorescence Detectors
Freq
Fluorescence
FALS Sensor
Fluorescence detector(PMT3, PMT4 etc.)
Purdue University Cytometry Laboratories
![Page 21: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/21.jpg)
21
Optical Filters
![Page 22: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/22.jpg)
22
Optics Scheme
![Page 23: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/23.jpg)
23
PMT
PMT
PMT
PMT
DichroicFilters
BandpassFilters
Example Channel Layout for Laser-based Flow Cytometry
Laser
1
2
3
4
Flow cell
original from Purdue University Cytometry Laboratories; modified by R.F. Murphy
Flow Layout
![Page 24: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/24.jpg)
24
Fluidics and Optics Review
Created an illumination region with the excitation optics
Passed the cells precisely through the illumination region using hydrodynamic focusing
Routed the generated light signals to the specific detectors by collection optics
![Page 25: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/25.jpg)
25
Electronics
Converts optical signals to proportional electronic signals (voltage pulses)
Analyzes voltage pulse height, area, or width
Interfaces with the computer for data transfer
![Page 26: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/26.jpg)
26
SIGNAL AND PATTERN GENERATION
PMT 1
LASER
PMT 1
LASER
PMT 1
LASER
VO
LT
AG
E
TIME
![Page 27: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/27.jpg)
27
PMT 1
LASER
FLUORESCENCE INTENSITY PATTERN FROM A CELL POPULATION
Nu
mb
er o
f ev
ents
Relative Fluorescence Intensity
low medium high
![Page 28: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/28.jpg)
28
DETECTION OF THREE FLUORESCENCE INTENSITY PATTERNS FROM CELL SURFACE
PMT 1
LASER
Relative Fluorescence Intensity
Nu
mb
er o
f ev
ents
low medium high
![Page 29: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/29.jpg)
29
Nu
mb
er o
f ev
ents
PMT 1
LASER
Relative Fluorescence Intensity
FLUORESCENT SIGNAL PATTERN COLLECTION
![Page 30: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/30.jpg)
30
SINGLE COLOR HISTOGRAMS
![Page 31: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/31.jpg)
31
Dot Plot
![Page 32: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/32.jpg)
32FL1
FL2
Uncompensated vs. Compensated
![Page 33: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/33.jpg)
33
Emissions Spectra
![Page 34: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/34.jpg)
34
Fluorescence Overlap
![Page 35: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/35.jpg)
35
Fluorescence Compensation
![Page 36: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/36.jpg)
36
FITC Compensation
![Page 37: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/37.jpg)
37
Compensation Examples
![Page 38: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/38.jpg)
38
A spectral image generated by fluoro-chromes G and O
Spectral energy fromfluorochrome G is subtracted from O
FUNDAMENTAL ASPECT OF COLOR COMPENSATIONHOW TO REMOVE GREEN (G) FROM ORANGE (O)
G O
![Page 39: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/39.jpg)
39
THREE PART DIFFERENTIAL ANALYSIS OF WHOLE BLOOD
Lig
ht
Sca
tter
Cell Volume
Lymphocytes
Granulocytes
Monocytes
BECTONDICKINSON
![Page 40: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/40.jpg)
40
BIVARIATE QUADRANTSFOR T-CELL SUBSET MARKERS
FSC
SS
C
A B
FL2
FL
1 + +++
Mandy et al., 2001
![Page 41: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/41.jpg)
41
COMPONENTS OF BIVARIATE QUADRANT DISPLAYDUAL T-CELL MARKERS: A=CD4 and B=CD3
A
BA
B
A
B++
+
+
--
![Page 42: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/42.jpg)
42
BIVARIATE QUADRANT HISTOGRAM FOR CD3 AND CD4 POSITIVE CELLS
++
+
+
-- +
![Page 43: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/43.jpg)
43
TWO COLOR PATTERN
10 1 10 2 10 3 10 4
CD3 -->
101
102
103
104
CD
4 -
->
FL1-CD3
FL2-C
D4 color
CD3-CD4- black
CD3+CD4- blue
CD3-CD4+ cyan
CD3+CD4+green
![Page 44: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/44.jpg)
44
THREE COLOR PATTERN
CD3
CD
4
10 1 10 2 10 3 10 4
CD3 -->
101
102
103
104
CD
4 --
>
CD3
CD
4
CD8C
D8
10 1 10 2 10 3 10 4
CD8 -->
101
102
103
104
CD
4 --
>
10 1 10 2 10 3 10 4
CD3 -->
101
102
103
104
CD
8 --
>
![Page 45: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/45.jpg)
45
10 1 10 2 10 3 10 4
CD56 -->
101
102
103
104
CD
4 --
>
10 1 10 2 10 3 10 4
CD3 -->
101
102
103
104
CD
4 --
>
CD3CD3 CD310 1 10 2 10 3 10 4
CD3 -->
101
102
103
104
CD
56 --
>
10 1 10 2 10 3 10 4
CD3 -->
101
102
103
104
CD
8 --
>
CD5610 1 10 2 10 3 10 4
CD56 -->
101
102
103
104
CD
8 --
>
CD56 CD810 1 10 2 10 3 10 4
CD8 -->
101
102
103
104
CD
4 --
>C
D4
CD
8
CD
56
CD
8
CD
4
CD
4
FOUR COLOR PATTERN
![Page 46: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/46.jpg)
46
FOUR COLOR DUAL LASER IMMUNOPHENOTYPING
Antibodies labeled with fluorescein
Antibodies labeled with phycoerythrin (PE)
Antibodies labeled with PE/CY5 or PerCP
Antibodies labeled with APC, CY5 or CY7
![Page 47: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/47.jpg)
47
CD45 BASED HETEROGENEOUS GATING FOR T-CELL SUBSETS
CD8 FL4C
D4
FL
2
SS
CD45 FL1
CD45-Gating Protocol
HC, NIH & CDC GUIDELINES
Bergeron et al. 2002
![Page 48: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/48.jpg)
48
Topics of Discussion
Testing Platforms Single Dual
Instrumentation Reagents
![Page 49: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/49.jpg)
49
Testing Platforms Single platform instrument Single platform testing can be performed
on flow cytometer using calibration beads. Cost per test is relatively higher.
Dual platform testing relies on a Hematology Analyzer. Hematology cost per test is relatively
inexpensive. Comparison of both platforms.
![Page 50: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/50.jpg)
50
Instrumentation Flow Cytometers
Beckman Coulter FC500, MCL-XL, Elite, Profile, Point Care
Becton Dickinson Canto, FACSCalibur, FACSCan, FACSort,
FACSCount Guava Technologies Inc.
Personal Cell Analyzer System (PCA) Partec - CyFlow Accuri Cytometers
Hematology Analyzers Coulter, Sysmex, Cell Dyn
Pipetters
![Page 51: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/51.jpg)
51
Flow Cytometry Software Beckman Coulter EPICS System II and
Expo 32 Becton Dickinson Simultest, Multitest, and
Cell Quest (Pro) for BD FACS Becton Dickinson FACSCount Guava PCA System Partec FloMax Accuri CFlow Plus TreeStar, Inc. FlowJo Verity Software House - WinList
![Page 52: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/52.jpg)
52
Reagents
There are many manufacturers of monoclonal antibodies. Select IVD reagents to ensure quality and reliability.
Cytometer manufacturers are a good source for flow reagents.
![Page 53: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/53.jpg)
53
Multi-color Antibody Panels 2-color panels (Leucogate
CD45/CD14, CD3/4, CD3/8, CD3/19, CD3/16+56)
3-color panels (CD3/4/8; CD3/4/45, CD3/8/45, CD3/19/45, CD3/16+56/45)
4-color panels (CD3/4/8/45, CD3/19/16+56/45)
![Page 54: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/54.jpg)
54
Instrument Maintenance Daily start-up and shut down Daily calibration Monthly and periodic maintenance Troubleshooting
![Page 55: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/55.jpg)
55
BD FACSCount Procedures Instrument Start Up Preparing and Running Controls Preparing and Running Samples Instrument Cleaning and
Maintenance Troubleshooting
![Page 56: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/56.jpg)
56
BD FACSCount Sample Prep Procedure
Material Whole blood sample collected in anticoagulant. BD FACSCount Reagents BD FACSCount Control Beads BD FACSCount Fixative BD Reverse Pipetter
Procedure Aliquot 50ul whole blood sample to FACSCount
Reagent tubes Incubate for 1 hour at RT Add 50 ul of fixative Run sample on instrument
![Page 57: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/57.jpg)
57
BD FACSCalibur Procedures Instrument Start up FACSComp Calibration Daily Controls Patient Samples Instrument Cleaning and
Maintenance Troubleshooting
![Page 58: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/58.jpg)
58
BD MultiTest Reagent Staining Procedure (Lyse No Wash) Materials
Whole blood collected in anticoagulant. MultiTest Reagent Panel BD FACSLyse Solution BD Falcon 12 x 75mm test tubes
Procedure Add 50ul of blood sample to 10ul of antibody reagent. Incubate for 15 minutes at RT Add 450ul of a working dilution of BD FACSLyse solution. Incubate for 15 minutes at RT Acquire samples on flow cytometer
![Page 59: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/59.jpg)
59
Beckman Coulter Epics / FC500 Procedures Instrument Start up FlowCheck & FlowSet Calibrations Fluorescence Compensation Daily Controls Patient Samples Instrument Cleaning and
Maintenance Troubleshooting
![Page 60: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/60.jpg)
60
Beckman Coulter Cyto-Stat Reagent Staining Procedure (Lyse No Wash)
Materials Whole Blood collected in anticoagulant. Coulter Cyto-Stat Reagent Panel Coulter T-Q Prep 12 x 75mm test tubes
Procedure Add 100ul of blood sample to 10ul of antibody reagent. Incubate for 15 minutes at RT Place tubes in T-Q Prep and start sample processing
run. Acquire samples on flow cytometer.
![Page 61: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/61.jpg)
61
Quality Control and Quality Assurance
Controls Reagents Instruments Proficiency Testing Training and Competency External Quality Assessment
UKNEQAS samples
![Page 62: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/62.jpg)
62
Patient Reporting and Data Management
Patient Confidentiality Reference Ranges Data List Mode Files Data Storage Devices
![Page 63: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/63.jpg)
63
Acknowledgements Beckman Coulter
Reagents & Training Material Becton Dickinson
Reagents & Training Material Health Canada, Francis Mandy, PhD
Training Material (PPT slides) Purdue U. Cytometry Laboratories
Training Material (PPT slides) Roswell Park Cancer Institute Laboratory of
Flow Cytometry, Carleton C. Stewart, Ph.D Training Material (PPT slides)
![Page 64: Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.](https://reader035.fdocuments.net/reader035/viewer/2022062320/56649cda5503460f949a38be/html5/thumbnails/64.jpg)
64
Conclusion
Thank you for your participation.