We Care for you and your Patients...ICU for bedside procedures Surgical Masks ASTM Level 3 OR Sta˚...

6
Personal Protective Equipment We Care for you and your Patients At VEN Medical, Our customers are in our mind in whatever we do. Facial Masks Isolation Gowns Coveralls Haircover Shoe Cover Gloves

Transcript of We Care for you and your Patients...ICU for bedside procedures Surgical Masks ASTM Level 3 OR Sta˚...

Page 1: We Care for you and your Patients...ICU for bedside procedures Surgical Masks ASTM Level 3 OR Sta˚ in sterile environments: Closeness of ˛t protects against ˝uid transmission or

Personal Protective Equipment

We Care for you and your PatientsAt VEN Medical, Our customers are in our mind in whatever we do.

Facial Masks Isolation Gowns Coveralls Haircover Shoe Cover Gloves

Page 2: We Care for you and your Patients...ICU for bedside procedures Surgical Masks ASTM Level 3 OR Sta˚ in sterile environments: Closeness of ˛t protects against ˝uid transmission or

Choose the right maskThe right mask is an ASTM-rated mask.

Follow the leaders

ASTM International sets the preferred international standard in healthcare for best practices inclusive of testing and requirements

for performance of materials. The FDA, who oversees the sale and marketing of all surgical masks, recommends that manufacturers

demonstrate mask performance in 4 areas:

Protection over preferenceSafety is everyone’s concern but your mask choice is your own. With all of the key facts and safety factors in mind for you can

select an ASTM-rated mask that is right for you and protects the best.

Fluid resistanceIn matters of splatter

When at risk of encountering blood and/or bodily fluid splatter, wear the recommended ASTM Level 3 fluid-resistant mask and get

the best protection for the OR.

Fit The fit is it

even the right mask not worn correctly could put you at risk. Nose and mouth must be coverd completely. Create a seal around the face to

prevent gaps that increase the risk of inhalation exposure

The “4 Fs” of selecting the right mask*Use ASTM standards to support choices around Filtrations and Fluid Resistance

Bells and whistles, Ties and loopsSecurement - loops or ties

Anit-fog film, form and tapesreduce distractions from fogging issues shields

and protective eyeware keep eyes clear ofblood and splash

FeaturesFiltrationFilter it

When your’re around smoke or are interacting with aTB-infected patient, properly protect yourself with a high

filtration mask (N95 Respirator)

Page 3: We Care for you and your Patients...ICU for bedside procedures Surgical Masks ASTM Level 3 OR Sta˚ in sterile environments: Closeness of ˛t protects against ˝uid transmission or

1

2

3

ASTM F2100-11 Levels Char

acte

rist

ics

Resi

stan

ce to

pen

etra

tion

by

synt

hetic

blo

od, m

inim

um

pres

sure

in m

m H

g fo

r pas

s res

ult

m

m H

20/c

m2

(Bre

atha

bilit

y)

Bact

eria

l

Sub-

mic

ron

part

icul

ates

Flam

e sp

read

Level 1: low barrier protection General use for short procedures and exams 80 mm Hg <4.0 ≥95% ≥95% Class1

Level 2: moderate barrier protection For low to moderate levels of aerosols, 120 mm Hg <5.0 ≥98% ≥98% Class1

Level 3: maximum barrier protection 160 mm Hg <5.0 ≥98% ≥98% Class1

Understanding ASTM levels of protection is key

Page 4: We Care for you and your Patients...ICU for bedside procedures Surgical Masks ASTM Level 3 OR Sta˚ in sterile environments: Closeness of ˛t protects against ˝uid transmission or

*

§

“General” or “Basic” implies abdominal

Common procedures where Cardinal Health Clinician’s recommend an ASTM LEVEL 3 MASK

Procedure MasksASTM Level 1

Patient & Sta� isolation:Clean environments, sterile cores,processing departments, ER andICU for bedside procedures

Surgical MasksASTM Level 3

OR Sta� in sterile environments:Closeness of �t protects against�uid transmission or - intended fora high-risk of �uid exposure

N95 RespiratorNIOSH N95

Protection againts residual surgicalsmoke or on patients wuth known or suspected aerosol transmitted diseases-- Tuberculosis | Varicella | Rubeola 2

Level UpThe di�erence in protection between a Level 2 mask and a Level 3 mask is minimal.

When it is solely a matter of micromillimeters, level up your mask selection and get the best protection with an ASTM Level 3 mask.

The risk of exposure to blood and bodily �uid splat-ter in the OR is signi�cant and the protection o�ered in an ASTM Level 1 mask is minimal. (Twicw the protection in aL3/L1)

When the risk is unknown or too great to ignore, Level up your mask selection and get the best pro

**

Page 5: We Care for you and your Patients...ICU for bedside procedures Surgical Masks ASTM Level 3 OR Sta˚ in sterile environments: Closeness of ˛t protects against ˝uid transmission or

AAMI PB70 guidelines

ANSI/AAMI PB70 Barrier performance

Test method Requirement Anticipated

AAMI Level 1 Water resistance: Impact penetration AATCC 42

AATCC 42 Measures the resistance of fabrics to the liquid penetration of water by impact

Water impact < 4.5 g Minimal

AAMI Level 2 Water resistance: Impact penetration AATCC 42

Water resistance:Hydrostatic pressureAATCC 27

AATCC 42 Measures the resistance of fabrics to the liquid penetration of water by impact

AATCC 127 Measures the resistance of fabrics to the liquid penetration of water by impact under constant and increasing hydrostatic pressure

Spray impact < 1.0 g

Hydrostatic Pressure > 20 cm

AAMI Level 3 Water resistance: Impact penetration AATCC 42

Water resistance:Hydrostatic pressureAATCC 27

AATCC 42 Measures the resistance of fabrics to the liquid penetration of water by impact

AATCC 127 Measures the resistance of fabrics to the liquid penetration of water by impact under constant and increasing hydrostatic pressure

Spray impact < 1.0 g

Hydrostatic pressure > 50 cm

Moderate

AAMI Level 4 ASTM F1671, Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System

ASTM F1671 Measures the resistance of materials used in protective clothing to penetration by blood borne pathogens using a surrogate microbe under conditions of continuous liquid contact.

Pass

Association for the Advancement of Medical Instrumentation.Protective Apparel and Drapes Intended for use in Health Care Facilities. ANSI/AAMI PB70:2012. Arlington, VA: AAMI.

Choose the Right Surgical Gown

Infection Control GuideSafety starts well before themoments a clinician entersthe patient’s room. Use thesetting usage key and materialdescriptions as a guide to select gowns and other apparel, soyou can provide the rightoptions for every situation.

AAMI Level guideWe’re your source for AAMI compliant gowns. Choose thelevel you need, based on the green/ orange/ blue/ purple color coding in the following chart

Page 6: We Care for you and your Patients...ICU for bedside procedures Surgical Masks ASTM Level 3 OR Sta˚ in sterile environments: Closeness of ˛t protects against ˝uid transmission or

Get In TouchWe Love to Hear From You

62, 9th Cross, Thirumangal Nagar,Peelamedu, Coimbatore - 641004.

+91 9384606891

VEN Medical India Private Limited