WATERMAIN NOTES: SEWER NOTES: CONTRACTOR TO …

1
DC DC DC ENTRANCE FEATURE DC DC DC DC DC DC 3+000 3+050 3+100 3+150 BLOCK 1 BLOCK 2 BLOCK 3 1.5m ASPHALT SIDEWALK 1.5m ASPHALT SIDEWALK 1.5m ASPHALT SIDEWALK ENTRANCE FEA 1.5m GARBAGE BUILDING DC DC DC DC DC ENTRANCE FEATURE DC DC DC DC DC DC 3+000 3+050 3+100 3+150 BLOCK 1 BLOCK 2 BLOCK 3 1.5m ASPHALT SIDEWALK 1.5m ASPHALT SIDEWALK 1.5m ASPHALT SIDEWALK ENTRANCE FEA 1.5m GARBAGE BUILDING DC DC E10 5 155 173 171 169 167 153 15.0m-200mmØ SAN @ 2.21% 27.0m-200mmØ SAN @ 6.00% 48.0m-200mmØ SAN @ 3.10% 25.4m-200mmØ SAN @ 1.00% 36.2m-200mmØ SAN @ 1.00% 18.9m-200mmØ SAN @ 1.00% 42.4m-250mmØ SAN @ 0.00% .3m-200mmØ SAN @ 6.62% 57.1m-20 8 E20 138 158 132 156 130 154 128 152 126 150 136 13.2m - 375mmØ STM @ 1.10% 31.4m-375mmØ STM @ 3.00% 33.0m-375mmØ STM @ 2.81% 26.3m-1050mmØ STM @ 0.70% 32.5m-1050mmØ STM @ 0.70% 22.7m-1200mmØ STM @ 0.70% 37.6m-300mmØ STM @ 0.00% 51.0m-3 46.5m-250mmØ STM @ 3.20% 27.0m-250mmØ STM @ 1.00% 31.1m-250mmØ STM @ 1.00% 19.3m-250mmØ STM @ 1.00% TEE DMA 11.25° V&VB 11.25° 11.25° V&VB 200mmØ WM-HV 200mmØ WM-HV 200mmØ WM-HV 200mmØ WM-HV CB-2 CB-1 CB-3 CB-4 CB-5 CB-6 CB-7 CB-8 CB-9 CB-10 200mmØ WM-HV V&VB CBMH-1 10.6m-250mmØ STM @ 1.00% 408 CB2 406 CB3 404 21.0m-250mmØ STM @ 1.00% 41.1m-250mmØ STM @ 1.00% 4.3m-250mmØ STM @ 1.00% 3+000 3+050 3+100 3+150 CB4 41 8.2m-525mmØ ST @ 1.00% 11.9m-250mmØ STM @ 0.50% 414 RYT1 8.0m-250mmØ CBLEAD @ 1.00% RYE1 10.3m-250mmØ CBLEAD @ 1.00% RYE2 CBMH1 3.7m-250mmØ CBLEAD @ 1.07% 14.7m-250mmØ CBLEAD @ 1.00% 5.0m-250mmØ STM @ 1.00% 17.3m - 2 RUNS TOTALING 15 STORMTECH SC-740 @ 0.06% 8.5m-250mmØ STM @ 1.00% 2.0m-250mmØ CBLEAD @ 1.00% 2.5m-250mmØ CBLEAD @ 2.77% 83mmØ ICD ORIFICE PLATE TO BE INSTALLED AT SOUTHWEST INLET OF STM MH 404 CAP CAP CAP CAP CAP CAP CAP CAP CAP EXISTING CAP INV. S.=62.40 EXISTING CAP INV.=65.41 RYT2 28.4m-250mmØ CBLEAD @ 1.00% TD2 T/G=65.30 INV.W=64.10 13.7m-200mmØ CBLEAD @ 1.00% TD1 T/G=65.82 INV.SW=64.49 6.9m-200mmØ STM @ 1.00% BLOCK 1 SERVICE TABLE STATION 3+041.38 3+041.39 3+041.88 3+041.89 3+042.38 3+042.39 SERVICE ELEVATION @ CAP 65.46m 65.48m 65.56m 65.58m 65.41m 65.43m SERVICE DESCRIPTION EXISTING 100mmØ STM INVERT PROPOSED 100mmØ STM INVERT @ CAP EXISTING 50mmØ WM OBVERT PROPOSED 50mmØ WM OBVERT @ CAP EXISTING 150mmØ SAN INVERT PROPOSED 150mmØ SAN INVERT @ CAP BLOCK 2 SERVICE TABLE STATION 3+084.41 3+084.91 3+085.41 SERVICE ELEVATION @ CAP 64.07m 64.17m 64.02m SERVICE DESCRIPTION PROPOSED 100mmØ STM INVERT @ CAP PROPOSED 50mmØ WM OBVERT @ CAP PROPOSED 150mmØ SAN INVERT @ CAP BLOCK 3 SERVICE TABLE STATION 3+141.73 3+141.88 3+142.23 3+142.39 3+142.74 3+142.89 SERVICE ELEVATION @ CAP 62.09m 62.10m 62.23m 62.24m 62.02m 62.03m SERVICE DESCRIPTION EXISTING 100mmØ STM INVERT PROPOSED 100mmØ STM INVERT @ CAP EXISTING 50mmØ WM OBVERT PROPOSED 50mmØ WM OBVERT @ CAP EXISTING 150mmØ SAN INVERT PROPOSED 150mmØ SAN INVERT @ CAP CATCHBASIN TABLE CB No. CB2 CB3 CB4 T/G ELEVATION 65.82 66.65 65.44 INVERT 64.42 65.25 64.04 ICD DIA. 94mmØ 83mmØ 108mmØ STM MANHOLE TABLE MANHOLE ID 404 406 408 414 EX. CAP STORMTECH1 INLET STORMTECH1 OUTLET T/G ELEV 65.60 66.96 67.19 67.46 65.52 66.54 66.03 INVERT E=63.96 NW=63.76 N=62.44 SW=63.28 SW=63.49 NW=63.43 NW=64.21 NE=63.90 SW=65.47 NW=65.41 S=62.40 SE=63.38 NE=63.37 REAR YARD CATCHBASIN TABLE RYCB No. CBMH1 RYE1 RYE2 RYT1 RYT2 TD1 TD2 T/G ELEVATION 67.74 67.40 67.50 67.50 67.55 65.82 65.30 INVERT S=66.06 NE=65.77 N=65.99 N=66.10 NE=65.83 S=65.89 NE=65.55 SW=65.55 SW=64.49 W=64.10 ICD. DIA 83mmØ - - - CB-LANDSCAPE M:\2006\106011\CAD\DESIGN - EAST\Condo Walkups\106011-WT-GP.dwg, GP-WT1-A1, Dec 15, 2017 - 2:25pm, kbanks PLANA1.DWG - 841mmx594mm NOTE: THE POSITION OF ALL POLE LINES, CONDUITS, WATERMAINS, SEWERS AND OTHER UNDERGROUND AND OVERGROUND UTILITIES AND STRUCTURES IS NOT NECESSARILY SHOWN ON THE CONTRACT DRAWINGS, AND WHERE SHOWN, THE ACCURACY OF THE POSITION OF SUCH UTILITIES AND STRUCTURES IS NOT GUARANTEED. BEFORE STARTING WORK, DETERMINE THE EXACT LOCATION OF ALL SUCH UTILITIES AND STRUCTURES AND ASSUME ALL LIABILITY FOR DAMAGE TO THEM. PROJECT No. REV DRAWING No. DRAWING NAME LOCATION No. REVISION DATE BY FOR REVIEW ONLY SCALE APPROVED CHECKED DRAWN CHECKED DESIGN Engineers, Planners & Landscape Architects S u i t e 2 0 0 , 2 4 0 M i c h a e l C o w p l a n d D r i v e Ottawa, Ontario, Canada K2M 1P6 T e l e p h o n e ( 6 1 3 ) 2 5 4 - 9 6 4 3 F a c s i m i l e ( 6 1 3 ) 2 5 4 - 5 8 6 7 W e b s i t e w w w . n o v a t e c h - e n g . c o m N.T.S. NORTH KEY PLAN RUE DU VIEUX-SILO STREET OPEN SPACE PRIVÉ DE LA RÉCOLTE PRIVATE FUTURE DEVELOPMENT 106011 REV # 4 MWB DDB SAM DDB DDB 1:250 10 0 1:250 4 8 2 6 PROJECT No. REV DRAWING No. DRAWING NAME No. REVISION DATE BY SCALE APPROVED CHECKED DRAWN CHECKED DESIGN HILLSIDE VISTA WALK-UP CONDOS CITY OF OTTAWA LOCATION CONSTRUCTION NORTH N MOCKINGBIRD CENTRUM HIGHWAY 174 PINTAIL PRESTONE DR RIVER RIDGE TULIP CR CR TR DR BV 10 LINE RD ST JOSEPH BV SITE BENCHMARK LOCATED ON TOP OF FIRE HYDRANT SPINDLE ON NORTHERN LIMITS OF EXISTING POLICE ROAD.(ELEVATION = 59.92m) SITE BENCHMARK 10 LINE RD ST JOSEPH BV TURNER CR 10 LINE RD OLD VIEUX-SILO ST ERIC CZAPNIK WAY N.T.S. NORTH KEY PLAN SITE ERIC CZAPNIK WAY GENERAL PLAN OF SERVICES 106011-GP-WT1 D07-12-16-0133 SEWER NOTES: 1. ALL WORKS SHALL BE PERFORMED IN ACCORDANCE WITH CITY OF OTTAWA STANDARDS AND SPECIFICATIONS F-4070, F-4080, F-4100 AND ANY OTHER APPLICABLE SPECIFICATION. 2. SPECIFICATIONS: ITEM SPEC. No. REFERENCE CATCHBASIN (600x600mm) S1 CITY OF OTTAWA STORM / SANITARY MANHOLE (1200Ø) 701.010 OPSD CB & CBMH FRAME & COVER S19, 400.020 CITY OF OTTAWA, OPSD STORM / SANITARY MH FRAME & COVER S24,S24.1,S25 CITY OF OTTAWA SEWER TRENCH - BEDDING (GRANULAR A) S6,S7 CITY OF OTTAWA COVER (GRANULAR A OR SAND) S6,S7 CITY OF OTTAWA STORM SEWER PVC SDR 35/CONC SANITARY SEWER PVC SDR 35 WITH RUBBER GASKETS CATCHBASIN LEAD PVC SDR 35 MINIMUM 1%, 250mmØ 3. STORM SEWER TYPE AND CLASS AS PER OPSD 807.010. 4. INSULATE ALL STORM AND SANITARY PIPES THAT HAVE LESS THAN 2.0m COVER AS PER CITY OF OTTAWA F-4102. 5. SEWER BEDDING SHALL BE CLASS 'B' AS PER CITY OF OTTAWA STANDARDS S6 AND S7 UNLESS OTHERWISE NOTED. 6. PIPE BEDDING, COVER AND BACKFILL ARE TO BE COMPACTED TO AT LEAST 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY. THE USE OF CLEAR CRUSHED STONE AS A BEDDING LAYER SHALL NOT BE PERMITTED. PIPE BEDDING DEPTH AS PER EXP GEOTECH REPORT DATED DECEMBER 2017. 7. FLEXIBLE CONNECTIONS ARE REQUIRED FOR ALL CONNECTIONS TO MANHOLES AND CONCRETE PIPES. CONTRACTOR TO USE KOR-N-SEAL OR EQUIVALENT. 8. THE OWNER SHALL REQUIRE THAT THE SITE SERVICING CONTRACTOR PERFORM FIELD TESTS FOR QUALITY CONTROL OF ALL SANITARY SEWERS. SPECIFICALLY THE LEAKAGE TESTING SHALL BE COMPLETED IN ACCORDANCE WITH OPSS 410.07.16 AND 407.07.25. THE FIELD TESTS SHALL BE PERFORMED IN THE PRESENCE OF A CERTIFIED PROFESSIONAL ENGINEER WHO SHALL SUBMIT A CERTIFIED COPY OF THE TEST RESULTS. 9. STORM MANHOLES WITH PIPES LESS THAN 900mm DIAMETER TO HAVE 300mm SUMP. 10. ALL CATCHBASINS ARE TO HAVE 600mm SUMPS AND INCLUDE 3m OF SUBDRAIN EXTENDED IN TWO DIRECTIONS AND PARALLEL WITH THE CURB FACE. 11. CONTRACTOR TO TELEVISE (CCTV) ALL PROPOSED SEWERS AS PER OPSS 409 AND CITY OF OTTAWA F-4090 AND DYE TEST SANITARY SEWERS. 12. SEWER TRENCHES TO BE BACKFILLED WITH NATIVE SOIL TO MATCH THE EXISTING SOIL PROFILE, IN ORDER TO MINIMIZE THE DIFFERENTIAL FROST HEAVING OVER THE SERVICES. 13. BEDDING AT THE ROCK/SOIL INTERFACE IS TO BE TRANSITIONED AT 5H:1V MINIMUM. 14. ALL SEWER PIPES INSTALLED TO A GRADIENT OF 0.50% OR LOWER USING A LASER DEVICE AND SHALL BE CHECKED WITH A LEVEL INSTRUMENT PRIOR TO BACKFILLING. 15. CONTRACTOR TO INSTALL CLAY SEALS IN SERVICE TRENCHES WHERE INDICATED. CLAY SEALS PER CITY OF OTTAWA STANDARD S8 AND MUST EXTEND A MINIMUM OF 1.5m. 16. SERVICES ARE TO BE CONSTRUCTED TO 1.0m FROM FACE OF BUILDING AT A MINIMUM SLOPE OF 1.0%. ALL SERVICES TO INCLUDE BACKWATER VALVES AS PER CITY OF OTTAWA SPECIFICATIONS S14 AND S14.1 17. CONTRACTOR TO TELEVISE (CCTV) ALL PROPOSED SEWERS, 200mmØ OR GREATER PRIOR TO BASE COURSE ASPHALT. UPON COMPLETION OF CONTRACT, THE CONTRACTOR IS RESPONSIBLE TO FLUSH AND CLEAN ALL SEWERS & APPURTENANCES. 18. STORMTECH SC-740 (OR APPROVED EQUIVALENT) TO BE INSTALLED AS PER MANUFACTURERS SPECIFICATIONS AND DESIGN. REFER TO STORMWATER MANAGEMENT REPORT FOR FURTHER DETAILS. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR REVIEW. WATERMAIN NOTES: 1. SPECIFICATIONS: ITEM SPEC. No. REFERENCE WATERMAIN TRENCHING W17 CITY OF OTTAWA THERMAL INSULATION IN SHALLOW TRENCHES W22, W23 CITY OF OTTAWA WATERMAIN CROSSING BELOW SEWER W25 CITY OF OTTAWA WATERMAIN CROSSING ABOVE SEWER W25.2 CITY OF OTTAWA WATERMAIN PIPE PVC DR 18(CLASS 150) CITY OF OTTAWA VALVE CHAMBER W11 CITY OF OTTAWA VALVE BOX W24 CITY OF OTTAWA TVS CONNECTION W4 CITY OF OTTAWA 2. SUPPLY AND CONSTRUCT ALL WATERMAINS AND APPURTENANCES IN ACCORDANCE WITH THE CITY OF OTTAWA STANDARDS AND SPECIFICATIONS. EXCAVATION, INSTALLATION, BACKFILL AND RESTORATION OF ALL WATERMAINS BY THE CONTRACTOR. CONNECTIONS AND SHUT-OFFS AT THE MAIN AND CHLORINATION OF THE WATER SYSTEM SHALL BE PERFORMED BY CITY OFFICIALS. NO WORK SHALL COMMENCE UNLESS A CITY WATER WORKS INSPECTOR IS ON SITE. REFER TO CITY OF OTTAWA SPECIFICATIONS F-4411, F-4412, F-4413, F-4414, F-4415, F-4417, F-4418, F-4419, F-4491, F-4492, F-4493, F-4494 AND ANY OTHER APPLICABLE SPECIFICATIONS. 3. WATERMAIN SHALL BE MINIMUM 2.4m DEPTH BELOW GRADE UNLESS OTHERWISE INDICATED. 4. WATERMAIN BEDDING DEPTH TO BE AS PER EXP GEOTECH REPORT DATED DECEMBER 2017. 5. MINIMUM CLEARNCE BETWEEN CROSSING PIPES TO BE 0.25m WHEN WATER CROSSES ABOVE THE PIPE AS PER CITY OF OTTAWA SPECIFICATION W 25.2 AND 0.50m WHEN WATER CROSSES BELOW THE PIPE AS PER CITY OF OTTAWA SPECIFICATION W 25. 6. INSULATE ALL WATERMAIN AT ALL CATCHBASINS AND LEADS AS PER W-23. 7. FIRE HYDRANTS AS PER CITY OF OTTAWA DETAILS W-18 AND W-19. 8. ALL WATERMAIN TO BE INSTALLED WITH THRUST BLOCKS AND RESTRAINING RINGS AS PER F-4492, W25.3, W25.4, W25.5 AND W25.6. NOTE LOCAL SOIL IS A CLAY WITH A BEARING CAPACITY BETWEEN 125 AND 175 kPa. THEREFORE, USE TABLES FOR BEARING CAPACITY OF 100-199 kPa. 9. THRUST BLOCKS TO BE INSTALLED ON ALL CAPS, TEES, CROSSES, HORIZONTAL BENDS, TAPPING VALVES, OTHER FITTINGS THAT STOP FLOW OR CHANGE DIRECTION OF FLOW AND HYDRANTS. 10. RESTRAINING RINGS TO BE INSTALLED ON ALL CAPS, TEES, CROSSES, HORIZONTAL AND VERTICAL BENDS, REDUCERS, SLEEVES, COUPLINGS, CURB-STUBS, AUXILIARY, ISOLATION/LINE/BRANCH VALVES, TAPPING VALVES, HYDRANTS, OTHER FITTINGS THAT STOP FLOW OR CHANGE DIRECTION AND PUSH ON JOINTS WITHIN RESTRAINED LENGTH AS PER CITY OF OTTAWA DETAIL W25.5 AND W25.6. 11. WHERE WATERMAIN DEFLECTION IS REQUIRED, DEFLECT AT A MAXIMUM 1/2 THE MANUFACTURERS RECOMMENDATION, MAXIMUM 1.5 ° PER DEFLECTION. 12. WATER SERVICE IS TO BE CONSTRUCTED TO WITHIN 1.0m OF FOUNDATION WALL AND CAPPED, UNLESS OTHERWISE INDICATED. 13. IN ACCORDANCE WITH THE CITY OF OTTAWA STANDARD W-18, NO DRIVEWAY SHALL BE LOCATED WITHIN 3.0m OF A FIRE HYDRANT. NO OBJECTS INCLUDING VEGETATION SHALL BE PLACED OR PLANTED WITHIN A 3.0m CORRIDOR BETWEEN A FIRE HYDRANT AND THE EDGE OF A ROADWAY OR A 1.5m RADIUS BESIDE OR BEHIND A FIRE HYDRANT. 14. CATHODIC PROTECTION REQUIRED FOR PVC WATERMAIN SYSTEMS AS PER CITY OF OTTAWA W40,W42, AND F-4494. ALL WATERMAIN TO BE INSTALLED COMPLETE WITH TRACER WIRE AS PER CITY OF OTTAWA W-36 AND F-4493. 15. WATERMAIN TESTING REQUIRED AS PER CITY OF OTTAWA SPECIFICATIONS F-4491 INCLUDING THE USE OF CHLORINATION NOZZLE AS PER CITY OF OTTAWA W46. APPROVED REFUSED THIS DAY OF , 20 JEFF MCEWEN, P.ENG., MANAGER DEVELOPMENT REVIEW, SUBURBAN SERVICES PRELIMINARY D.D. BLAIR 100122737 L I C E N S E D P R O F E S S I O N A L E N G I N E E R O I R A T N O F O E C N I V O R P 1. ISSUED FOR CLIENT REVIEW JAN 29/16 DDB FUTURE CENTRUM EXTENSION 2. ISSUED FOR COORDINATION JUL 4/16 DDB 3. ISSUED FOR SITE PLAN APPROVAL AUG 26/16 DDB TO BE ABANDONED AS PER CITY OF OTTAWA DETAIL S11.4 TO BE ABANDONED AS PER CITY OF OTTAWA DETAIL S11.4 TO BE ABANDONED AS PER CITY OF OTTAWA DETAIL S11.4 TO BE ABANDONED AS PER CITY OF OTTAWA DETAIL S11.4 REFER TO 106011-GR-WT FOR ADDITIONAL NOTES RELOCATE EXISTING FIRE HYDRANT LEGEND PROPOSED BARRIER CURB EXISTING CATCHBASIN CB EXISTING HYDRANT HYD 150mmØ EXISTING CATCHBASIN MANHOLE CBMH EXISTING VALVE & VALVE BOX V&VB EXISTING WATERMAIN 750mmØ SAN EXISTING STORM MH & SEWER EXISTING SANITARY MH & SEWER 250mmØ 300mmØ STM WITH DIRECTION OF FLOW WITH DIRECTION OF FLOW EXISTING STREET LIGHT EXISTING CABLE TELEVISION PEDESTAL EXISTING PADMOUNT HYDRO TRANSFORM EXISTING BELL GRADE LEVEL BOX PROPOSED CATCHBASIN DC CB-1 CBMH-1 PROPOSED CATCH BASIN MANHOLE 136 250mmØ 11.25°,22.5° V&VB 100 101 SITE BENCHMARK (59.92m) REFER TO KEY PLAN FOR LOCATION EXISTING TOWNHOUSE SERVICE LOCATIO PROPOSED SANITARY MANHOLE & SEWER WITH DIRECTION OF FLOW PROPOSED STORM MANHOLE & SEWER WITH DIRECTION OF FLOW EXISTING STORM BOX MANHOLE WITH ICD ORIFICE PLATE EXISTING TOWNHOUSE SERVICE LOCATION PROPOSED DEPRESSED CURB PROPOSED WATERMAIN AND DIAMETER PROPOSED VALVE & VALVE BOX PROPOSED STANDPOST PROPOSED WATERMAIN BEND & THRUSTBLOCK PROPOSED SANITARY/STORM/WATERMAIN CAP PROPOSED WATERMAIN TEE EXISTING PAVER PROPOSED WATERMAIN INSULATION (W23) PIPE CROSSING (REFER TO TABLE) 1 PROPOSED FIRE HYDRANT C/W LEAD AND VALVE PROPOSED STORMTECH STORMWATER MANAGEMENT SYSTEM (REFER TO MANUFACTURERS DETAILS IN SWM REPORT) 4. ISSUED FOR SITE PLAN SUBMISSION DEC 15/17 DDB PROPOSED TRENCH DRAIN RYE1 PROPOSED REAR YARD ELBOW RYT1 PROPOSED REAR YARD TEE PROPOSED TACTILE WALKING SURFACE INDICATOR (TWSI) EASEMENT IN FAVOUR OF CONDO #709 PROPOSED INTERLOCK STONE PROPOSED BIKE RACKS SITE PLAN BOUNDARY/PROPERTY LINE PROPOSED RETAINING WALL C/W 1.2m HIGH CHAINLINK FENCE PROPOSED RETAINING WALL C/W DECORATIVE RAILING DECORATIVE RAILING PROPOSED RETAINING WALL

Transcript of WATERMAIN NOTES: SEWER NOTES: CONTRACTOR TO …

Page 1: WATERMAIN NOTES: SEWER NOTES: CONTRACTOR TO …

DC

DCDC

EN

TR

AN

CE

FE

AT

UR

E

DC

DC

DC

D

C

D

C

D

C

3

+

0

0

0

3+050

3

+

1

0

0

3+

150

BLOCK 1BLOCK 2

BLOCK 3

1.5m

A

SP

HA

LT

S

ID

EW

ALK

1.5m ASPHALT SIDEWALK

1.5m

A

SP

HA

LT

S

ID

EW

ALK

E

N

TR

A

N

C

E

F

E

A

T

U

R

E

1.5

m

AS

PH

ALT

SID

EW

ALK

GARBAGE

BUILDING

DC

DC

DC

DCDC

EN

TR

AN

CE

FE

AT

UR

E

DC

DC

DC

D

C

D

C

D

C

3

+

0

0

0

3+050

3

+

1

0

0

3+

150

BLOCK 1BLOCK 2

BLOCK 3

1.5m

A

SP

HA

LT

S

ID

EW

ALK

1.5m ASPHALT SIDEWALK

1.5m

A

SP

HA

LT

S

ID

EW

ALK

E

N

TR

A

N

C

E

F

E

A

T

U

R

E

1.5

m

AS

PH

ALT

SID

EW

ALK

GARBAGE

BUILDING

DC

DC

E10

5

155

173

171

169

1

6

7

153

15.0m

-200m

S

AN

@ 2.21%

27.0m

-200m

S

AN

@

6.00%

48.0m-200mmØ SAN @ 3.10%

25.4

m

-200m

m

Ø S

AN

@

1.0

0%

3

6

.

2

m

-

2

0

0

m

m

Ø

S

A

N

@

1

.

0

0

%

18.9m

-200m

m

Ø

S

A

N

@

1.00%

42.4

m-2

50m

SA

N @

0.0

0%

2

6

.3

m

-

2

0

0

m

m

Ø

S

A

N

@

6

.6

2

%

5

7

.1

m

-

2

0

0

m

m

Ø

S

A

N

@

5

.6

5

%

8

E20

138

158

132

156

130

1

5

4

128

1

5

2

1

2

6

150

136

1

3

.

2

m

-

3

7

5

m

m

Ø

S

T

M

@

1

.

1

0

%

31.4m

-375m

S

TM

@

3.00%

33.0m-375mmØ STM

@ 2.81%

26.3

m

-1050m

m

Ø

ST

M

@

0.7

0%

3

2

.

5

m

-

1

0

5

0

m

m

Ø

S

T

M

@

0

.

7

0

%

22.7m

-1200m

m

Ø

S

T

M

@

0.70%

37.6

m-3

00m

ST

M @

0.0

0%

5

1

.0

m

-

3

7

5

m

m

Ø

S

T

M

@

2

.7

4

%

46.5m-250mmØ STM @ 3.20%

27.0m

-250m

m

Ø

S

TM

@

1.00%

3

1

.

1

m

-

2

5

0

m

m

Ø

S

T

M

@

1

.

0

0

%

19.3m

-250m

m

Ø

S

T

M

@

1.00%

T

E

E

D

M

A

1

1

.2

5

°

V

&

V

B

1

1

.

2

5

°

1

1

.2

5

°

V

&

V

B

200mmØ WM-HV

200m

m

Ø

W

M

-H

V

200m

m

Ø

W

M

-H

V

200m

m

Ø

W

M

-H

V

CB-2

CB-1

CB

-3

CB

-4

C

B

-

5

C

B

-

6

C

B

-7

C

B

-8

C

B

-9

C

B

-10

2

0

0

m

m

Ø

W

M

-

H

V

V

&

V

B

CBMH-1

10.6m-250mmØ STM

@ 1.00%

408

CB2

406

CB

3

4

0

4

21.0m

-250m

S

TM

@

1.00%

41.1

m-2

50m

ST

M @

1.0

0%

4.3m-250mmØ

STM @ 1.00%

3

+

0

0

0

3+050

3

+

1

0

0

3+

150

CB

4

410

8.2m

-525m

m

Ø

S

T

M

@

1.00%

11.9m

-250m

m

Ø

S

TM

@

0.50%

414

RYT1

8.0m-250mmØ

CBLEAD @ 1.00%

RYE1

1

0

.

3

m

-

2

5

0

m

m

Ø

C

B

L

E

A

D

@

1

.

0

0

%

RYE2

CBMH1

3.7m-250mmØ

CBLEAD @ 1.07%

14.7m-250mmØ

CBLEAD @ 1.00%

5.0m

-250m

ST

M @

1.00%

17.3m

- 2 R

UN

S T

OT

ALIN

G 15

ST

OR

MT

EC

H S

C-740 @

0.06%

8

.5

m

-2

5

0

m

m

Ø

S

T

M

@

1

.0

0

%

2.0m-250mmØ

CBLEAD @ 1.00%

2.5m-250mmØ

CBLEAD @ 2.77%

83mmØ ICD

ORIFICE PLATE TO

BE INSTALLED AT

SOUTHWEST INLET

OF STM MH 404

CA

P

CA

P

CA

P

CA

P

CA

P

CA

P

CA

P

CA

P

CA

P

EXISTING CAP

INV. S.=62.40

EXISTING CAP

INV.=65.41

RYT2

28.4m-250mmØ

CBLEAD @ 1.00%

TD2

T/G=65.30

INV.W=64.10

1

3

.

7

m

-

2

0

0

m

m

Ø

C

B

L

E

A

D

@

1

.

0

0

%

TD1

T/G=65.82

INV.SW=64.49

6.9m-200mmØ

STM @ 1.00%

BLOCK 1 SERVICE TABLE

STATION

3+041.38

3+041.39

3+041.88

3+041.89

3+042.38

3+042.39

SERVICE ELEVATION

@ CAP

65.46m

65.48m

65.56m

65.58m

65.41m

65.43m

SERVICE

DESCRIPTION

EXISTING 100mmØ STM INVERT

PROPOSED 100mmØ STM INVERT @ CAP

EXISTING 50mmØ WM OBVERT

PROPOSED 50mmØ WM OBVERT @ CAP

EXISTING 150mmØ SAN INVERT

PROPOSED 150mmØ SAN INVERT @ CAP

BLOCK 2 SERVICE TABLE

STATION

3+084.41

3+084.91

3+085.41

SERVICE ELEVATION

@ CAP

64.07m

64.17m

64.02m

SERVICE

DESCRIPTION

PROPOSED 100mmØ STM INVERT @ CAP

PROPOSED 50mmØ WM OBVERT @ CAP

PROPOSED 150mmØ SAN INVERT @ CAP

BLOCK 3 SERVICE TABLE

STATION

3+141.73

3+141.88

3+142.23

3+142.39

3+142.74

3+142.89

SERVICE ELEVATION

@ CAP

62.09m

62.10m

62.23m

62.24m

62.02m

62.03m

SERVICE

DESCRIPTION

EXISTING 100mmØ STM INVERT

PROPOSED 100mmØ STM INVERT @ CAP

EXISTING 50mmØ WM OBVERT

PROPOSED 50mmØ WM OBVERT @ CAP

EXISTING 150mmØ SAN INVERT

PROPOSED 150mmØ SAN INVERT @ CAP

CATCHBASIN TABLE

CB No.

CB2

CB3

CB4

T/G ELEVATION

65.82

66.65

65.44

INVERT

64.42

65.25

64.04

ICD DIA.

94mmØ

83mmØ

108mmØ

STM MANHOLE TABLE

MANHOLE ID

404

406

408

414

EX. CAP

STORMTECH1 INLET

STORMTECH1 OUTLET

T/G ELEV

65.60

66.96

67.19

67.46

65.52

66.54

66.03

INVERT

E=63.96

NW=63.76

N=62.44

SW=63.28

SW=63.49

NW=63.43

NW=64.21

NE=63.90

SW=65.47

NW=65.41

S=62.40

SE=63.38

NE=63.37

REAR YARD CATCHBASIN TABLE

RYCB No.

CBMH1

RYE1

RYE2

RYT1

RYT2

TD1

TD2

T/G ELEVATION

67.74

67.40

67.50

67.50

67.55

65.82

65.30

INVERT

S=66.06

NE=65.77

N=65.99

N=66.10

NE=65.83

S=65.89

NE=65.55

SW=65.55

SW=64.49

W=64.10

ICD. DIA

83mmØ

-

-

-

CB-LANDSCAPE

M:\2

00

6\1

06

01

1\C

AD

\D

ES

IG

N - E

AS

T\C

on

do

W

alku

ps\1

06

01

1-W

T-G

P.d

wg

, G

P-W

T1

-A

1, D

ec 1

5, 2

01

7 - 2

:2

5p

m, kb

an

ks

PLANA1.DWG - 841mmx594mm

NOTE:

THE POSITION OF ALL POLE LINES, CONDUITS,

WATERMAINS, SEWERS AND OTHER

UNDERGROUND AND OVERGROUND UTILITIES AND

STRUCTURES IS NOT NECESSARILY SHOWN ON

THE CONTRACT DRAWINGS, AND WHERE SHOWN,

THE ACCURACY OF THE POSITION OF SUCH

UTILITIES AND STRUCTURES IS NOT GUARANTEED.

BEFORE STARTING WORK, DETERMINE THE EXACT

LOCATION OF ALL SUCH UTILITIES AND

STRUCTURES AND ASSUME ALL LIABILITY FOR

DAMAGE TO THEM.

PROJECT No.

REV

DRAWING No.

DRAWING NAME

LOCATION

No. REVISION DATEBY

FOR REVIEW ONLY

SCALE

APPROVED

CHECKED

DRAWN

CHECKED

DESIGN

Engineers, Planners & Landscape Architects

Suite 200, 240 Michael Cowpland Drive

Ottawa, Ontario, Canada K2M 1P6

Telephone (613) 254-9643

Facsimile (613) 254-5867

Website www.novatech-eng.com

N.T.S.

NORTH KEY PLAN

R

U

E

D

U

V

I

E

U

X

-

S

I

L

O

S

T

R

E

E

T

OPEN

SPACE

PRIVÉ DE LA RÉCOLTE PRIVATE

FUTURE

DEVELOPMENT

106011

REV # 4

MWB

DDB

SAM

DDB

DDB

1:250

100

1:250

4 82 6

PROJECT No.

REV

DRAWING No.

DRAWING NAME

No. REVISION DATEBY

SCALE

APPROVED

CHECKED

DRAWN

CHECKED

DESIGN

HILLSIDE VISTA WALK-UP CONDOS

CITY OF OTTAWA

LOCATION

CO

NS

TR

UC

TIO

N N

OR

TH

N

M

O

C

K

IN

G

B

IR

D

C

E

N

T

R

U

M

HIGHWAY 174

PINTAIL

P

R

E

S

T

O

N

E

D

R

R

IV

E

R

R

ID

G

E

TU

LIP

CR

CR

TR

D

R

B

V

10 LIN

E R

D

S

T

J

O

S

E

P

H

B

V

SITE BENCHMARK LOCATED ON TOP

OF FIRE HYDRANT SPINDLE ON

NORTHERN LIMITS OF EXISTING

POLICE ROAD.(ELEVATION = 59.92m)

SITE BENCHMARK

10 LIN

E R

D

ST

JOS

EP

H B

V

TURNER

CR

1

0

L

IN

E

R

D

O

L

D

VIE

UX

-S

ILO

ST

ER

IC

C

ZA

PN

IK

WA

Y

N.T.S.

NORTH KEY PLAN

SITE

ERIC CZAPNIK WAY

GENERAL PLAN OF SERVICES

106011-GP-WT1

D07-

12-1

6-01

33

SEWER NOTES:

1. ALL WORKS SHALL BE PERFORMED IN ACCORDANCE WITH CITY OF OTTAWA STANDARDS

AND SPECIFICATIONS F-4070, F-4080, F-4100 AND ANY OTHER APPLICABLE SPECIFICATION.

2. SPECIFICATIONS:

ITEM SPEC. No. REFERENCE

CATCHBASIN (600x600mm) S1 CITY OF OTTAWA

STORM / SANITARY MANHOLE (1200Ø) 701.010 OPSD

CB & CBMH FRAME & COVER S19, 400.020 CITY OF OTTAWA, OPSD

STORM / SANITARY MH FRAME & COVER S24,S24.1,S25 CITY OF OTTAWA

SEWER TRENCH - BEDDING (GRANULAR A) S6,S7 CITY OF OTTAWA

COVER (GRANULAR A OR SAND) S6,S7 CITY OF OTTAWA

STORM SEWER PVC SDR 35/CONC

SANITARY SEWER PVC SDR 35 WITH RUBBER GASKETS

CATCHBASIN LEAD PVC SDR 35 MINIMUM 1%, 250mmØ

3. STORM SEWER TYPE AND CLASS AS PER OPSD 807.010.

4. INSULATE ALL STORM AND SANITARY PIPES THAT HAVE LESS THAN 2.0m COVER AS PER

CITY OF OTTAWA F-4102.

5. SEWER BEDDING SHALL BE CLASS 'B' AS PER CITY OF OTTAWA STANDARDS S6 AND S7

UNLESS OTHERWISE NOTED.

6. PIPE BEDDING, COVER AND BACKFILL ARE TO BE COMPACTED TO AT LEAST 95% OF THE

STANDARD PROCTOR MAXIMUM DRY DENSITY. THE USE OF CLEAR CRUSHED STONE AS A

BEDDING LAYER SHALL NOT BE PERMITTED. PIPE BEDDING DEPTH AS PER EXP GEOTECH

REPORT DATED DECEMBER 2017.

7. FLEXIBLE CONNECTIONS ARE REQUIRED FOR ALL CONNECTIONS TO MANHOLES AND

CONCRETE PIPES. CONTRACTOR TO USE KOR-N-SEAL OR EQUIVALENT.

8. THE OWNER SHALL REQUIRE THAT THE SITE SERVICING CONTRACTOR PERFORM FIELD

TESTS FOR QUALITY CONTROL OF ALL SANITARY SEWERS. SPECIFICALLY THE LEAKAGE

TESTING SHALL BE COMPLETED IN ACCORDANCE WITH OPSS 410.07.16 AND 407.07.25. THE

FIELD TESTS SHALL BE PERFORMED IN THE PRESENCE OF A CERTIFIED PROFESSIONAL

ENGINEER WHO SHALL SUBMIT A CERTIFIED COPY OF THE TEST RESULTS.

9. STORM MANHOLES WITH PIPES LESS THAN 900mm DIAMETER TO HAVE 300mm SUMP.

10. ALL CATCHBASINS ARE TO HAVE 600mm SUMPS AND INCLUDE 3m OF SUBDRAIN EXTENDED

IN TWO DIRECTIONS AND PARALLEL WITH THE CURB FACE.

11. CONTRACTOR TO TELEVISE (CCTV) ALL PROPOSED SEWERS AS PER OPSS 409 AND CITY

OF OTTAWA F-4090 AND DYE TEST SANITARY SEWERS.

12. SEWER TRENCHES TO BE BACKFILLED WITH NATIVE SOIL TO MATCH THE EXISTING SOIL

PROFILE, IN ORDER TO MINIMIZE THE DIFFERENTIAL FROST HEAVING OVER THE

SERVICES.

13. BEDDING AT THE ROCK/SOIL INTERFACE IS TO BE TRANSITIONED AT 5H:1V MINIMUM.

14. ALL SEWER PIPES INSTALLED TO A GRADIENT OF 0.50% OR LOWER USING A LASER DEVICE

AND SHALL BE CHECKED WITH A LEVEL INSTRUMENT PRIOR TO BACKFILLING.

15. CONTRACTOR TO INSTALL CLAY SEALS IN SERVICE TRENCHES WHERE INDICATED. CLAY

SEALS PER CITY OF OTTAWA STANDARD S8 AND MUST EXTEND A MINIMUM OF 1.5m.

16. SERVICES ARE TO BE CONSTRUCTED TO 1.0m FROM FACE OF BUILDING AT A MINIMUM

SLOPE OF 1.0%. ALL SERVICES TO INCLUDE BACKWATER VALVES AS PER CITY OF

OTTAWA SPECIFICATIONS S14 AND S14.1

17. CONTRACTOR TO TELEVISE (CCTV) ALL PROPOSED SEWERS, 200mmØ OR GREATER PRIOR

TO BASE COURSE ASPHALT. UPON COMPLETION OF CONTRACT, THE CONTRACTOR IS

RESPONSIBLE TO FLUSH AND CLEAN ALL SEWERS & APPURTENANCES.

18. STORMTECH SC-740 (OR APPROVED EQUIVALENT) TO BE INSTALLED AS PER

MANUFACTURERS SPECIFICATIONS AND DESIGN. REFER TO STORMWATER MANAGEMENT

REPORT FOR FURTHER DETAILS. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR

REVIEW.

WATERMAIN NOTES:

1. SPECIFICATIONS:

ITEM SPEC. No. REFERENCE

WATERMAIN TRENCHING W17 CITY OF OTTAWA

THERMAL INSULATION IN SHALLOW TRENCHES W22, W23 CITY OF OTTAWA

WATERMAIN CROSSING BELOW SEWER W25 CITY OF OTTAWA

WATERMAIN CROSSING ABOVE SEWER W25.2 CITY OF OTTAWA

WATERMAIN PIPE PVC DR 18(CLASS 150) CITY OF OTTAWA

VALVE CHAMBER W11 CITY OF OTTAWA

VALVE BOX W24 CITY OF OTTAWA

TVS CONNECTION W4 CITY OF OTTAWA

2. SUPPLY AND CONSTRUCT ALL WATERMAINS AND APPURTENANCES IN ACCORDANCE WITH THE

CITY OF OTTAWA STANDARDS AND SPECIFICATIONS. EXCAVATION, INSTALLATION, BACKFILL AND

RESTORATION OF ALL WATERMAINS BY THE CONTRACTOR. CONNECTIONS AND SHUT-OFFS AT

THE MAIN AND CHLORINATION OF THE WATER SYSTEM SHALL BE PERFORMED BY CITY OFFICIALS.

NO WORK SHALL COMMENCE UNLESS A CITY WATER WORKS INSPECTOR IS ON SITE. REFER TO

CITY OF OTTAWA SPECIFICATIONS F-4411, F-4412, F-4413, F-4414, F-4415, F-4417, F-4418, F-4419,

F-4491, F-4492, F-4493, F-4494 AND ANY OTHER APPLICABLE SPECIFICATIONS.

3. WATERMAIN SHALL BE MINIMUM 2.4m DEPTH BELOW GRADE UNLESS OTHERWISE INDICATED.

4. WATERMAIN BEDDING DEPTH TO BE AS PER EXP GEOTECH REPORT DATED DECEMBER 2017.

5. MINIMUM CLEARNCE BETWEEN CROSSING PIPES TO BE 0.25m WHEN WATER CROSSES ABOVE THE

PIPE AS PER CITY OF OTTAWA SPECIFICATION W 25.2 AND 0.50m WHEN WATER CROSSES BELOW

THE PIPE AS PER CITY OF OTTAWA SPECIFICATION W 25.

6. INSULATE ALL WATERMAIN AT ALL CATCHBASINS AND LEADS AS PER W-23.

7. FIRE HYDRANTS AS PER CITY OF OTTAWA DETAILS W-18 AND W-19.

8. ALL WATERMAIN TO BE INSTALLED WITH THRUST BLOCKS AND RESTRAINING RINGS AS PER

F-4492, W25.3, W25.4, W25.5 AND W25.6. NOTE LOCAL SOIL IS A CLAY WITH A BEARING CAPACITY

BETWEEN 125 AND 175 kPa. THEREFORE, USE TABLES FOR BEARING CAPACITY OF 100-199 kPa.

9. THRUST BLOCKS TO BE INSTALLED ON ALL CAPS, TEES, CROSSES, HORIZONTAL BENDS, TAPPING

VALVES, OTHER FITTINGS THAT STOP FLOW OR CHANGE DIRECTION OF FLOW AND HYDRANTS.

10. RESTRAINING RINGS TO BE INSTALLED ON ALL CAPS, TEES, CROSSES, HORIZONTAL AND

VERTICAL BENDS, REDUCERS, SLEEVES, COUPLINGS, CURB-STUBS, AUXILIARY,

ISOLATION/LINE/BRANCH VALVES, TAPPING VALVES, HYDRANTS, OTHER FITTINGS THAT STOP

FLOW OR CHANGE DIRECTION AND PUSH ON JOINTS WITHIN RESTRAINED LENGTH AS PER CITY

OF OTTAWA DETAIL W25.5 AND W25.6.

11. WHERE WATERMAIN DEFLECTION IS REQUIRED, DEFLECT AT A MAXIMUM 1/2 THE

MANUFACTURERS RECOMMENDATION, MAXIMUM 1.5 ° PER DEFLECTION.

12. WATER SERVICE IS TO BE CONSTRUCTED TO WITHIN 1.0m OF FOUNDATION WALL AND CAPPED,

UNLESS OTHERWISE INDICATED.

13. IN ACCORDANCE WITH THE CITY OF OTTAWA STANDARD W-18, NO DRIVEWAY SHALL BE LOCATED

WITHIN 3.0m OF A FIRE HYDRANT. NO OBJECTS INCLUDING VEGETATION SHALL BE PLACED OR

PLANTED WITHIN A 3.0m CORRIDOR BETWEEN A FIRE HYDRANT AND THE EDGE OF A ROADWAY

OR A 1.5m RADIUS BESIDE OR BEHIND A FIRE HYDRANT.

14. CATHODIC PROTECTION REQUIRED FOR PVC WATERMAIN SYSTEMS AS PER CITY OF OTTAWA

W40,W42, AND F-4494. ALL WATERMAIN TO BE INSTALLED COMPLETE WITH TRACER WIRE AS PER

CITY OF OTTAWA W-36 AND F-4493.

15. WATERMAIN TESTING REQUIRED AS PER CITY OF OTTAWA SPECIFICATIONS F-4491 INCLUDING

THE USE OF CHLORINATION NOZZLE AS PER CITY OF OTTAWA W46.

APPROVED REFUSED

THIS DAY OF , 20

JEFF MCEWEN, P.ENG., MANAGER

DEVELOPMENT REVIEW, SUBURBAN SERVICES

PRELIMINARY

D.D. BLAIR

100122737

LIC

E

N

S

E

D

P

R

O

F

E

SSIO

N

A

L

E

N

G

I

N

E

ER

O

I

R

A

T

N

O

FO

E

C

N

I

V

O

R

P

1. ISSUED FOR CLIENT REVIEW JAN 29/16 DDB

FUTURE

CENTRUM

EXTENSION

2. ISSUED FOR COORDINATION JUL 4/16 DDB

3. ISSUED FOR SITE PLAN APPROVAL AUG 26/16 DDB

TO BE ABANDONED AS PER

CITY OF OTTAWA DETAIL

S11.4

TO BE ABANDONED

AS PER CITY OF

OTTAWA DETAIL

S11.4

TO BE ABANDONED

AS PER CITY OF

OTTAWA DETAIL

S11.4

TO BE ABANDONED

AS PER CITY OF

OTTAWA DETAIL

S11.4

REFER TO 106011-GR-WT FOR ADDITIONAL NOTES

RELOCATE EXISTING

FIRE HYDRANT

LEGEND

PROPOSED BARRIER CURB

EXISTING CATCHBASINCB

EXISTING HYDRANT

HYD

150mmØ

EXISTING CATCHBASIN MANHOLECBMH

EXISTING VALVE & VALVE BOX

V&VB

EXISTING WATERMAIN

750mmØ SAN

EXISTING STORM MH & SEWER

EXISTING SANITARY MH & SEWER

250mmØ

300mmØ STM

WITH DIRECTION OF FLOW

WITH DIRECTION OF FLOW

EXISTING STREET LIGHT

EXISTING CABLE TELEVISION PEDESTAL

EXISTING PADMOUNT HYDRO TRANSFORMER

EXISTING BELL GRADE LEVEL BOX

PROPOSED CATCHBASIN

DC

CB-1

CBMH-1PROPOSED CATCH BASIN MANHOLE

136

250mmØ

11.25°,22.5°

V&VB

100

101

SITE BENCHMARK (59.92m)

REFER TO KEY PLAN FOR LOCATION

EXISTING TOWNHOUSE SERVICE LOCATION

PROPOSED SANITARY MANHOLE & SEWER

WITH DIRECTION OF FLOW

PROPOSED STORM MANHOLE & SEWER

WITH DIRECTION OF FLOW

EXISTING STORM BOX MANHOLE

WITH ICD ORIFICE PLATE

EXISTING TOWNHOUSE SERVICE LOCATION

PROPOSED DEPRESSED CURB

PROPOSED WATERMAIN AND DIAMETER

PROPOSED VALVE & VALVE BOX

PROPOSED STANDPOST

PROPOSED WATERMAIN BEND &

THRUSTBLOCK

PROPOSED SANITARY/STORM/WATERMAIN CAP

PROPOSED WATERMAIN TEE

EXISTING PAVER

PROPOSED WATERMAIN INSULATION (W23)

PIPE CROSSING (REFER TO TABLE)1

PROPOSED FIRE HYDRANT

C/W LEAD AND VALVE

PROPOSED STORMTECH STORMWATER

MANAGEMENT SYSTEM (REFER TO

MANUFACTURERS DETAILS IN SWM REPORT)

4. ISSUED FOR SITE PLAN SUBMISSION DEC 15/17 DDB

PROPOSED TRENCH DRAIN

RYE1PROPOSED REAR YARD ELBOW

RYT1PROPOSED REAR YARD TEE

PROPOSED TACTILE WALKING SURFACE INDICATOR (TWSI)

EASEMENT IN

FAVOUR OF

CONDO #709

PROPOSED INTERLOCK STONE

PROPOSED BIKE RACKS

SITE PLAN BOUNDARY/PROPERTY LINE

PROPOSED RETAINING WALL C/W

1.2m HIGH CHAINLINK FENCE

PROPOSED RETAINING WALL C/W

DECORATIVE RAILING

DECORATIVE RAILING

PROPOSED RETAINING WALL