VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts...

15
141 140 Top features and comfort VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system uses the latest technology to achieve the highest level of features and comfort at the lowest energy cost. The reliability, flexibility, ease of installation and the high number of possible configurations are to some of the numerous advantages that the VRF System offers you.

Transcript of VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts...

Page 1: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

141140

Top features and comfort

VR

F

Ra

ng

e

Outdoor unit

Cassette

DuctsCompact products

Ducts

Floor-ceiling

Large Ceiling

Wall Mounted

Wall Ceiling

The variable refrigerant f low system uses the

latest technology to achieve the highest level of

features and comfort at the lowest energy cost .

The rel iabil i ty, f lexibi l i ty, ease of instal lat ion

and the high number of possible conf igurations

are to some of the numerous advantages that

the VRF System offers you.

140-141 ING 5/5/06 08:57 Página 2

Page 2: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

143142

Up to 16 indoor units for one outdoor unit 28 kW

Heig

ht

diffe

ren

ce :

50

m m

ax.

Actu

al p

ipe leng

th : 1

00m

max.

Heig

ht

diffe

ren

ce :

15

m m

ax.

.Equivalent pipe length: 120m maximum.

.Total pipe length: 200m maximum.

Heat Pump

Heat Recovery

Transmission line

Cooling

Heating

* AOG90TPBMF

High COP 20% higgercompared to outdoor

units of equivalentclass

Cooling COP

Heating COP

Tem

pera

ture

High-power mode

Energy saving mode

Time

15% energy saving

15% quicker

Tem

pera

ture

Power Consumption

Time

High-power mode

Energy saving mode

High

low High

Req

uired

cap

acity

Operating capacity

Comp.1

Comp.2

Comp.3

Power accumulation technology

Wide performance range

The outdoor unit can operate within a range of outside temperatures

from -15ºC to 52ºC in cooling mode, and from 15ºC to 21ºC in heat-

ing mode.

*Heat pump series

High COP

The new refrigerant dual flow control system using dual control

technology and the optimum balance of the multi compressor sys-

tem provide the highest efficiency, reaching COP levels greater

than outdoor units of an equivalent class.

Multi compressor system

The compressor capacity is obtained via the

optimum balance of three compressors that

are individually adjusted. This technology is

extremely efficient and allows the coolant flow

to be precisely adjusted.

Selectable Operation Mode

The high power or energy-saving operation can be

selected at wil l and these have the effect of

changing the air diffusion temperature by 2ºC.

The energy save mode allows consumption to be

reduced by 15% and the high power mode

increases the capacity by an equal amount.

VR

F

te

ch

no

lo

gy

VRF S-Series

Design Flexibi l i ty

The VRF system allows installation of up to 16

indoor units for each outdoor unit (up to 13

units on the 8 HP), with a connected power of

up to 130% of the outdoor unit's capacity.

Easy to install

All the outdoor and indoor units connect to a

single, non-polar twin-strand transmission line,

avoiding errors and simplifying installation.

Extended cooling distances

The distance between the fur thest indoor unit and the out-

door unit can reach 100 m and with a height difference of

50 m. The system allows the total length of refrigerant

pipes of 200 m.

142-143 ING 5/5/06 12:25 Página 2

Page 3: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

A O Y 9 0 T PA M F

145144

AOY90 TPAMBF

AOY90 TPAMF AOY90 TPBMF AOY72 TPBMF

R407C R407C R407C

3 PH, 380 - 415V, 50 Hz 3 PH, 380 - 415V, 50 Hz 3 PH, 380 - 415V, 50 Hz

28 28 22,4

31,5 31,5 25,2

9,4 9 7,2

10 8,5 7,6

3,0 3,1 3,1

3,2 3,7 3,3

Plate fin coil Plate fin coil Plate fin coil

730 730 730

360 360 360

9800 9800 9800

Propeller x 2 Propeller x 2 Propeller x 2

150 x 2 150 x 2 150 x 2

1,5/3,4/5,0 1,5/3,4/4,9 1,5/2,5/4,8

Internal protector (OCR)/HPRV Internal protector (OCR)/HPRV Internal protector (OCR)/HPRV

1380 x 1300 x 650 1380 x 1300 x 650 1380 x 1300 x 650

1535 x 1400 x 770 1535 x 1400 x 770 1535 x 1400 x 770

306 285 278

343 321 314

57 55 54

R407C R407C R407C

10 12 10

Ø 12,7 Ø 12,7 Ø 12,7

Ø 19,05 - -

Ø 28,58 Ø 28,58 Ø 28,58

100 100 100

50 50 50

-5 to 52 -15 to 52 -5 to 52

-15 to 21 -15 to 21 -15 to 21

M o d e l s

VR

F S

-S

er

ies

AOY90 TPAMF AOY90 TPBMF AOY72 TPBMF

3DGF7010 3DGF7030 3DGF7040

6.023 5.450 4.922

Code

Price ref.

MODEL

Refrigerant

Power Requeriment

Capacity Cooling kW

Heating kW

Power consumption Cooling kW

Heating kW

Energy Efficiency Ratio (E.E.R.) Cooling

Heating

Heat exchanger

Fan speed High r.p.m.

Low r.p.m.

Air flow High m3/h

Fan Type x Qty.

Fan motor output W

Compressor Motor output kW

Protection kW

Dimensions (Height x Width x Depth) Net mm

Gross mm

Weight Net kg

Gross kg

Noise level 380V dB (A)

Refrigerant Type

Charge kg

Pipes Size Liquid mm

Discharge Gas mm

Suction Gas mm

Maximum length m

Maximum height m

Operating range Cooling °C

Heating °C

H i g h r e l i a b i l i t y :In the event of compressor failure, the remaining compressors can con-

tinue operating.

F r e e o f e l e c t r o n i c d i s t u r b a n c e s : Given that the VRF system does not use Inverter technology, there is

no interference with electronic units.

E a s y t o i n s t a l l : Its compact size and the possibility of making cooling connections in

any direction simplify installation.

Te c h n i c a l s p e c i f i c a t i o n s

3 compressors

No harmon ic d is tu rbances

Easy ins ta l la t ion

Ou

tdo

or

un

its

V

RF

S-S

er

ies

Comp. 1

Comp. 2

Comp. 3

Harmful effects

Officeautomation

Factoryautomation

Power distributionfacilities.

144-145 ING 5/5/06 09:11 Página 144

Page 4: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

147

A U Y 2 0 - 2 5 - 3 5 - 4 0 - 5 0

146

AUY20 AUY25 AUY35 AUY40 AUY50

2,15 2,8 3,6 4 5

1849 2408 3096 3440 4300

2,45 3,1 4,1 4,5 5,45

2107 2666 3526 3870 4687

220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

28 28 52 52 50

0,13 0,13 0,23 0,23 0,22

0,15 0,15 0,27 0,27 0,26

530 530 580 580 640

480 480 520 520 540

410 410 460 460 470

38 38 41 41 44

35 35 37 37 38

31 31 34 34 35

570 570 570 570 570

570 570 570 570 570

230 230 230 230 230

18 18 18 18 18

1/4” 1/4” 1/4” 1/4” 1/4”

3/8” 3/8” 1/2” 1/2” 5/8”

Flare Flare Flare Flare Flare

R407C R407C R407C R407C R407C

18 to 30 18 to 30 18 to 30 18 to 30 18 to 30

16 to 30 16 to 30 16 to 30 16 to 30 16 to 30

AUY20-50

Electrical componentsbox (inside)

Wide openingto facilitate access

Filter that can bedetached and

cleaned

2-way 3-way

4-way

Fan.

2 ~ 4 way a i r f low sys tem.

Easy Main tenance .

- Low sound level thanks to its variable fan.- Compact design that adapts to the 600x600 mm

panels.- Condensate pump with elevation up to 400 mm.

AUY20 AUY25 AUY35 AUY40 AUY50

3DGF7300 3DGF7310 3DGF7320 3DGF7330 3DGF7340

AUY 7LFBAF AUY 9LFBAF AUY 12LFBAF AUY 14LFBAF AUY 18LFBAF

823 838 859 907 941

Unit Code

Logistic reference

Price ref.

M o d e l s

In

do

or

VR

F

MODEL

Cooling capacity kW

kcal/h

Heating capacity kW

kcal/h

Power supply V/nº/Hz

Power consumption W

Current A

Maximum current A

Air flow High m3/h

Medium m3/h

Low m3/h

Noise Level High db (A)

Medium db (A)

Low db (A)

Dimensions Width mm

Depth mm

Height mm

Weight kg

Pipe size Liquid Inches

Gas Inches

Pipe connection method

Refrigerant

Operating range Cooling ºC

Heating ºC

A c c e s s i b i l i t y :It has a large opening that facilitates access to the filter, electrical

components and the fan, simplifying maintenance tasks.

G r e a t e r c o m f o r t : The automatic positioning of the output angle, the selection of the

number of channels and the possibility of distributing the air through

auxiliary ducts allow it to be adapted to any environment.

Te c h n i c a l s p e c i f i c a t i o n s

Co

mp

ac

t c

as

se

tte

146-147 ING 4/5/06 17:33 Página 146

Page 5: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

149

A U Y 5 0 - 7 1 - 8 0 - 1 0 0 - 1 2 5 - 1 4 0

148

AUY50 AUY71 AUY80 AUY100 AUY125 AUY140

5,7 7,05 8,8 10,5 12,7 14,1

4.902 6.063 7.568 9.020 10.940 12.120

5,8 7,85 9,1 10,7 13,7 15,8

4.988 6.751 7.840 9.200 11.790 13.580

220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

104 124 140 175 190 219

0,6 0,64 0,67 0,92 0,94 0,95

0,72 0,77 0,8 1,1 1,12 1,14

1.000 1.100 1.200 1.500 1.650 1.780

840 940 1.050 1.300 1.450 1.550

700 780 840 1.100 1.200 1.300

41 43 46 48 49 52

37 40 43 44 47 48,5

33 35 37 41 43 45

830 830 830 830 830 830

830 830 830 830 830 830

246 246 246 296 296 296

34 34 34 40 40 40

1/4” 1/4” 3/8" 3/8" 3/8" 3/8"

5/8” 5/8” 5/8” 3/4" 3/4" 3/4"

Flare Flare Flare Flare Flare Flare

R407C R407C R407C R407C R407C R407C

18 to 30 18 to 30 18 to 30 18 to 30 18 to 30 18 to 30

16 to 30 16 to 30 16 to 30 16 to 30 16 to 30 16 to 30

AUY50-140

AUY50 AUY71 AUY80 AUY100 AUY125 AUY140

3DGF7350 3DGF7360 3DGF7370 3DGF7380 3DGF7390 3DGF7395

AUY 20LFBRF AUY 25LFBRF AUY 30LFBRF AUY 36LFBSF AUY 45LFBSF AUY 54LFBSF

958 998 1.112 1.257 1.328 1.396

Unit Code

Logistic reference

Price ref.

M o d e l s

- Low sound level thanks to its variable fan.- Air discharge system from 2 to 4 channels.- Condensate pump with elevation up to 800 mm.

In

do

or

VR

F

MODEL

Cooling capacity kW

kcal/h

Heating capacity kW

kcal/h

Power supply V/nº/Hz

Power consumption W

Current A

Maximum current A

Air flow High m3/h

Medium m3/h

Low m3/h

Noise level High db (A)

Medium db (A)

Low db (A)

Dimensions Width mm

Depth mm

Height mm

Weight kg

Pipe size Liquid inches

Gas inches

Pipe connection method

Refrigerant type

Operating range Cooling ºC

Heating ºC

A c c e s s i b i l i t y :It has a large opening that facilitates access to the filter, electrical

components and the fan, simplifying maintenance tasks.

A d j u s t a b l e h e i g h t : There is a possibility of reducing its height for installation in false ceil-

ings with little free space.

Te c h n i c a l s p e c i f i c a t i o n s

Ca

ss

ett

e

Ha

Hb

Long life filter

Its highly efficientand long life filterprolongs thecleaning cycle.

Easymaintenance

Easy to access thecontrol box duringmaintenance.

Detachable,washable filter

Wide opening andlong-life filter.

F lex ib le ins ta l la t ion .

Easy Main tenance .

Standard setting

Slender setting

Long lifefilter

148-149 ING 4/5/06 17:37 Página 148

Page 6: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

151150

ARY20 ARY25 ARY35 ARY40 ARY50

2,15 2,8 3,5 4 5,3

1840 2420 3000 3450 4560

2,45 3,1 4,1 4,8 5,6

2120 2670 3530 4130 4810

220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

40 43 34 50 62

0,21 0,21 0,2 0,23 0,27

0,25 0,25 0,24 0,27 0,32

340 420 460 640 750

320 390 430 560 700

290 360 390 480 640

0/40 0/40 0/40 0/40 0/40

31 35 28 34 36

28 33 27 32 35

26 31 26 30 33

663 663 953 953 953

595 595 595 595 595

217 217 217 217 217

18 18 25 25 25

1/4” 1/4” 1/4” 1/4” 1/4”

3/8” 3/8” 1/2” 1/2” 5/8”

Flare Flare Flare Flare Flare

R407C R407C R407C R407C R407C

18 to 30 18 to 30 18 to 30 18 to 30 18 to 30

16 to 30 16 to 30 16 to 30 16 to 30 16 to 30

ARY20-50

ARY20 ARY25 ARY35 ARY40 ARY50

3DGF7400 3DGF7410 3DGF7420 3DGF7430 3DGF7440

ARY 7LFKBF ARY 9LFKBF ARY 12LFKDF ARY 14LFKDF ARY 18LFKDF

575 590 670 707 750

A R Y 2 0 - 2 5 - 3 5 - 4 0 - 5 0

Unit Code

Logistic reference

Price ref.

- Low-profile, with a height of just 217 mm.- Horizontal or vertical installation.

M o d e l s

In

do

or

VR

F

MODEL

Cooling capacity kW

kcal/h

Heating capacity kW

kcal/h

Power supply V/nº/Hz

Power consumption W

Current A

Maximum current A

Air flow High m3/h

Medium m3/h

Low m3/h

Static pressure (Min/Máx) Pa

Noise level High db (A)

Medium db (A)

Low db (A)

Dimensions Width mm

Depth mm

Height mm

Weight kg

Pipe size Liquid inches

Gas inches

Pipe connection method

Refrigerant type

Operating range Cooling ºC

Heating ºC

E a s y t o i n s t a l l :Its compact low-profile design and the possibility of horizontal or verti-

cal configuration allow for a wide range of installation possibilities.

Q u i e t o p e r a t i o n : For the purpose of minimising its impact in small rooms, the sound

level has been reduced to 26 dB(A).

Te c h n i c a l s p e c i f i c a t i o n s

Co

mp

ac

t d

uc

t

Cei l ing pos i t ion ing .

F loo r pos i t ion ing .

150-151 ING 4/5/06 17:41 Página 150

Page 7: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

153

A R Y 7 1 - 8 0 - 1 0 0 - 1 2 5

152

ARY71 ARY80 ARY100 ARY125 ARY170H

7,05 8,8 10,5 12,7 17

6070 7560 9070 10960 14620

7,85 9,1 10,7 13,7 17,6

6750 7.810 9200 11840 15150

380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

155 240 265 315 733

0,68 1,06 1,16 1,44 3,58

0,84 1,58 1,58 1,84 4,81

1200 1650 2000 2200 3000

1100 1550 1800 2000 2750

1000 1350 1600 1800 2500

30/160 30/180 30/180 40/180 80/300

44 47 47 49 53

42 45 45 47 52

40 43 43 45 51

1210 1210 1210 1210 1250

700 700 700 700 800

270 270 270 270 400

43 43 45 45 75

1/4” 3/8" 3/8" 3/8" 3/8"

5/8” 5/8” 3/4" 3/4" 3/4"

Flare Flare Flare Flare Flare

R407C R407C R407C R407C R407C

18 to 30 18 to 30 18 to 30 18 to 30 18 to 30

16 to 30 16 to 30 16 to 30 16 to 30 16 to 30

ARY71-170H

ARY71 ARY80 ARY100 ARY125 ARY170H

3DGF7450 3DGF7460 3DGF7470 3DGF7480 3DGF7490

ARY25LFBNK ARY30LFBNK ARY36LFBNK ARY45LFBNK ARY60LFBKF

785 897 1.010 1.122 1.676

A R Y 1 7 0

Unit Code

Logistic reference

Price ref.

M o d e l s

- Up to model 45 in low profile of 270 mm.- Return through the upper or lower part.

In

do

or

VR

F

MODEL

Cooling capacity kW

kcal/h

Heating capacity kW

kcal/h

Power supply V/nº/Hz

Power consumption W

Current A

Maximum current A

Air flow High m3/h

Medium m3/h

Low m3/h

Static pressure (Min/Máx) Pa

Noise level High db (A)

Medium db (A)

Low db (A)

Dimensions Width mm

Depth mm

Height mm

Weight kg

Pipe size Liquid inches

Gas inches

Pipe connection method

Refrigerant type

Operating range Cooling ºC

Heating ºC

V e r s a t i l e d i s t r i b u t i o n :With an available pressure of up to 300 Pa for the AR60H and AR90H

models, it is possible to carry out wide distribution of ducts to condi-

tion several areas.

S i m p l e c o n n e c t i o n s :The condensate pipes can be connected in different directions to facili-

tate installation.

Te c h n i c a l s p e c i f i c a t i o n s

Du

ct

/ H

igh

pr

es

su

re

du

ct

Inse r ted in the ce i l ing

Fa lse beam

Ins ta l la t ion methods .

152-153 ING 5/5/06 12:30 Página 152

Page 8: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

155

A B Y 3 5 - 4 0 - 5 0 - 7 1

154

ABY35 ABY40 ABY50 ABY71

3,5 4,05 5,3 6,6

3000 3480 4560 5670

4,1 5 5,6 7,7

3530 4310 4810 6630

220/1/50 220/1/50 220/1/50 220/1/50

57 57 88 88

0,25 0,25 0,38 0,38

0,3 0,3 0,45 0,45

640 640 770 900

560 560 680 780

480 480 560 660

41 41 47 50

38 38 42,5 46

35 35 38 42

990 990 990 990

655 655 655 655

199 199 199 199

28 28 28 30

1/4” 1/4” 1/4” 1/4”

1/2” 1/2” 5/8” 5/8”

Flare Flare Flare Flare

R407C R407C R407C R407C

18 to 30 18 to 30 18 to 30 18 to 30

16 to 30 16 to 30 16 to 30 16 to 30

ABY35-71

4

5

32

1

4

3

2

1

ABY35 ABY40 ABY50 ABY71

3DGF7200 3DGF7210 3DGF7220 3DGF7230

ABY12LFBJF ABY14LFBJF ABY18LFBJF ABY24LFBJF

789 827 878 916

Unit Code

Logistic reference

Price ref.

M o d e l s

- Horizontal or vertical installation.- Slim, compact design.

HORIZONTAL FAN VERTICAL FAN

Ins ta l la t ion methods .

Doub le au tomat ic fan .

Floor

Ceiling

In

do

or

VR

F

MODEL

Cooling capacity kW

kcal/h

Heating capacity kW

kcal/h

Power supply V/nº/Hz

Power consumption W

Current A

Maximum current A

Air flow High m3/h

Medium m3/h

Low m3/h

Noise level High db (A)

Medium db (A)

Low db (A)

Dimensions Width mm

Depth mm

Height mm

Weight kg

Pipe size Liquid inches

Gas inches

Pipe connection method

Refrigerant type

Operating range Cooling ºC

Heating ºC

E x c e l l e n t a i r d i s t r i b u t i o n : The combination of s lat movements al lows ful l control of ai r

distr ibut ion.

H i g h l e v e l o f c o m f o r t : The low sound level and automatic movement of the slats in accor-

dance with the mode selected provide a high level of comfort.

Te c h n i c a l s p e c i f i c a t i o n s

flo

or

/ C

eil

ing

154-155 ING 4/5/06 17:59 Página 154

Page 9: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

157

A B Y 8 0 - 1 0 0 - 1 2 5 - 1 4 0

156

ABY80 ABY100 ABY125 ABY140

8,8 10,5 12,7 14,1

7560 9070 10960 12150

9,1 10,7 13,7 15,8

7810 9200 11840 13610

220/1/50 220/1/50 220/1/50 220/1/50

124 144 160 180

1,14 1,16 1,17 1,17

1,36 1,39 1,40 1,40

1420 1660 1850 1900

1350 1500 1660 1700

1190 1270 1430 1450

41,5 47 50 52

38 44 48 50

34,5 39 44 46

1660 1660 1660 1660

700 700 700 700

240 240 240 240

48 48 48 49

3/8” 3/8” 3/8” 3/8”

5/8" 3/4” 3/4” 3/4”

Flare Flare Flare Flare

R407C R407C R407C R407C

18 to 30 18 to 30 18 to 30 18 to 30

16 to 30 16 to 30 16 to 30 16 to 30

ABY80-140

ABY80 ABY100 ABY125 ABY140

3DGF7240 3DGF7250 3DGF7260 3DGF7270

ABY30LFBGF ABY36LFBGF ABY45LFBGF ABY54LFBGF

1.023 1.130 1.712 2.291

Unit Code

Logistic reference

Price ref.

M o d e l s

In

do

or

VR

F

MODEL

Cooling capacity kW

kcal/h

Heating capacity kW

kcal/h

Power supply V/nº/Hz

Power consumption W

Current A

Maximum current A

Air flow High m3/h

Medium m3/h

Low m3/h

Noise level High db (A)

Medium db (A)

Low db (A)

Dimensions Width mm

Depth mm

Height mm

Weight kg

Pipe size Liquid inches

Gas inches

Pipe connection method

Refrigerant type

Operating range Cooling ºC

Heating ºC

E x c e l l e n t a i r d i s t r i b u t i o n : The combination of slat movements allows full control of air

distribution.

S e v e r a l i n s t a l l a t i o n p o s s i b i l i t i e s : The unit can be attached to the ceiling, semi-concealed or wall

mounted, simplifying the choice of location.

Te c h n i c a l s p e c i f i c a t i o n s

La

rg

e C

eil

ing

4

3

2

1

Ins ta l la t ion poss ib i l i t i es .

Tw in au tomat ic sweep.

Open Concea led

Wal l mounted

R igh t - le f t sweep

Steps selectable 5 posiciones

Up-down sweep

Steps se lec tab le4 pos ic iones

- Allows the contribution of outside air.- Twin adjustment of the air discharge direction.- Easy access long-life filter.

156-157 ING 4/5/06 18:05 Página 156

Page 10: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

159

A S Y 2 0 2 5 - 3 5 - 4 0

A S Y 5 0 - 7 1 - 8 0

158

ASY20 ASY25 ASY35 ASY40 ASY50 ASY71 ASY80

2,15 2,8 3,5 3,8 5,4 6,8 8

1860 2420 3000 3270 4640 5848 6880

2,45 3,1 4,1 4,5 5,6 7,7 8,8

2120 2670 3530 3870 4820 6622 7560

220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

26 30 35 39 38 50 60

0,15 0,16 0,18 0,2 0,18 0,24 0,28

0,18 0,19 0,22 0,24 0,22 0,29 0,34

410 450 520 540 840 950 1060

380 410 500 510 700 800 930

350 370 470 490 600 670 780

30 33 37 38 42,5 45 48

28 30 36 37 38,5 41 45

26 27 34 35 35 37 41

808 808 808 808 1120 1120 1120

187 187 187 187 220 220 220

257 257 257 257 320 320 320

8,2 8,2 8,2 8,2 16 16 16

1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 5/8”

3/8” 3/8” 1/2” 1/2” 5/8” 5/8” 5/8”

Flare Flare Flare Flare Flare Flare Flare

R407C R407C R407C R407C R407C R407C R407C

18 to 30 18 to 30 18 to 30 18 to 30 18 to 30 18 to 30 18 to 30

16 to 30 16 to 30 16 to 30 16 to 30 16 to 30 16 to 30 16 to 30

ASY20-80

ASY20 ASY25 ASY35 ASY40 ASY50 ASY71 ASY80

3DGF7150 3DGF7140 3DGF7160 3DGF7100 3DGF7105 3DGF7120 3DGF7130

ASY7LFBDF ASY9LFBDF ASY12LFBDF ASY14LFBDF ASY18LFBJF ASY24LFBJF ASY30LFBJF

491 501 514 533 568 592 762

Unit Code

Logistic reference

Price ref.

M o d e l s

- Low noise level.- Excellent control of air distribution.- New compact models with reduced dimensions.

In

do

or

VR

F

MODEL

Cooling capacity kW

kcal/h

Heating capacity kW

kcal/h

Power supply V/nº/Hz

Power consumption W

Current A

Maximum current A

Air flow High m3/h

Medium m3/h

Low m3/h

Noise level High db (A)

Medium db (A)

Low db (A)

Dimensions Width mm

Depth mm

Height mm

Weight kg

Pipe size Liquid inches

Gas inches

Pipe connection method

Refrigerant type

Operating range Cooling ºC

Heating ºC

N e w c o m p a c t m o d e l : The dimensions of these model (AS 7 - AS 14) have been reduced by

42% compared to the previous design. They also incorporate a new

removable panel that can be easily cleaned.

A e s t h e t i c d e s i g n : The vertical and horizontal symmetry provides an elegant design thatcombines with any interior decor.

Te c h n i c a l s p e c i f i c a t i o n s

Wa

ll M

ou

nte

d

4

3

2

1

43

2

1

Wide down flow.

Horizontal concentration and otherair direction control.

Au tomat ic tw in fan and g rea te r range .

Coo l ing

Heat ing

Steps

Swing

Large deflector and independent operation

158-159 ING 4/5/06 18:11 Página 158

Page 11: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

161

AW Y 4 0 - 5 0 - 7 1 - 8 0

160

AWY40 AWY50 AWY71 AWY80

4,3 5,4 6,9 8

3700 4640 5950 6880

4,9 5,6 7,8 8,8

4210 4810 6700 7560

220/1/50 220/1/50 220/1/50 220/1/50

21 30 40 50

0,1 0,14 0,19 0,24

0,12 0,17 0,23 0,29

650 760 900 950

570 660 780 870

490 560 650 780

37 40 44 47

35 37 41 45

32 34 37 42

1150 1150 1150 1150

285 285 285 285

270 270 270 270

16 16 16 16

1/4” 1/4” 1/4” 3/8”

1/2” 5/8” 5/8” 5/8”

Flare Flare Flare Flare

R407C R407C R407C R407C

18 to 30 18 to 30 18 to 30 18 to 30

16 to 30 16 to 30 16 to 30 16 to 30

AWY40 - AWY80

AWY40 AWY50 AWY71 AWY80

3DGF7530 3DG7540 3DGF7550 3DGF7560

AWY14LFBJ AWY18LFBJ AWY24LFBJ AWY30LFBJ

604 642 672 836

Unit Code

Logistic reference

Price ref.

M o d e l s

- Outstanding and exclusive design.- Powerful air current.- Easy access long-life filter.

Conventional slat

New slat thatreduces turbulence

Silent fan that reduces the noise level

Low no ise leve l .

In

do

or

VR

F

MODEL

Cooling capacity kW

kcal/h

Heating capacity kW

kcal/h

Power supply V/nº/Hz

Power consumption W

Current A

Maximum current A

Air flow High m3/h

Medium m3/h

Low m3/h

Noise level High db (A)

Medium db (A)

Low db (A)

Dimensions Width mm

Depth mm

Height mm

Weight kg

Pipe size Liquid inches

Gas inches

Pipe connection method

Refrigerant type

Operating range Cooling ºC

Heating ºC

L o w n o i s e l e v e l :

The new design of the deflector that removes turbulence and the wide

upper air return reduce the noise level.

E a s y a c c e s s :

The drainage tray can be easily removed and the long-life filter is

removed simply by pressing it.

Te c h n i c a l s p e c i f i c a t i o n s

Wa

ll C

eil

ing

160-161 ING 5/5/06 12:32 Página 160

Page 12: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

Configuration of control system

Building ManagementAir ConditioningCentral Control

Air Conditioning

Individual ControlSystem

General-purposebuildingcontrol computerGeneral-purpose air conditioning

control computer

Air conditioning control /

monitoring

Error monitoring

Connectable to various

sized BMS

Central Remote Controller

Air Conditioning control / monitoring

Weekly timer

Error display

PC Controller

Air conditioning control / monitoring

Electricity charge calculation

Annual operation schedule control

Daily report / Monthly report control

Transmission Adaptor(BMS / RS-232C Cable)

Network Convertor(BMS / LONWORKS®)

LONWORKS® is a registered mark of Echelon Corporation.

Wired Remote Controller

Wireless Remote Controller

Simple Remote Controller

Service Tool

Monitoring

Refrigerant System List

Device status Details Screen

Device status Circuit Diagram

Error Display

Outdoor unit

Indoor unit

NetworkConvertor

Transmission line

(LONWORKS® Network)

Transmission line (RS-232C Cable)

Public telephone line

Remote controller line

Remote controller line

(Single System)

Rede LONWORKS®

Ethernet Network

System DiagramTransmission adaptor

line is non-polar 2-conductor.

Refrigerantsystem 1

Refrigerantsystem 64

Serial cable (RS-232C)

Maximum 400 units can be controlled Air conditioning control Operation monitoring Failure diagnosis System set-up Billing calculation (option)

Outdoor unit

Indoor unit

Wired remotecontroller

Simple remotecontroller

Wireless remotecontroller

Transmission line(non-polar 2-conductor)

Powersupply line

Remote controllerline

Maximum 16 units can be connected. One central remote controller can connect up to 64 groups / 400 indoor units.

Maximum 16 units can be controlled

PC Controller

Controlador remoto central

Remote controller line

Indoor unit can be controlledfrom both remote controllers.

2 remote controllers

Big multi systemSingle system

Together with central remote controller,it is possible to build non remotecontroller system.

System without remote controller

Transmission line

Network convertor

UTR-YSSANetwork convertor

UTR-YSSA

163

VR

F c

on

tro

ls

162

W i d e r a n g e o f c o n t r o l p o s s i b i l i t i e s :

The units can be administered from cable, wireless, simplified or cen-

tralised controls, via PC or through external control systems.

S i m p l e m a i n t e n a n c e :

A PC can be connected at any point of the transmission line in order to

manage or supervise the system.

L e s s w i r i n g :

A twin strand, non-polar single line is sufficient to connect all the

units.

H i g h c a p a c i t y :

Up to 400 indoor units can be connected to a transmission system.

I n t e g r a t i o n o f o t h e r a p p a r a t u s :

Possibility of integrating split or large room units into the VRF control

system.

Co

ntr

ol

sy

ste

ms

162-163 ING 5/05/06 12:36 Página 162

Page 13: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

165164

UTB - YUB UTB - YVA UTB - YPA

3NGF9050 3DGF9411 3DGF9450

95 42 76

Code

Price ref.

M o d e l s

Wired remote cont ro l le r

UTB - YUB

Wi re less remote cont ro l le r

UTB - YVA

Simple remote cont ro l le r

UTB - YPA

VR

F c

on

tro

ls

Remote control lers Wired remote control ler

UTB - YUB

Wireless remote control ler

UTB - YVA

Simple remote control ler

UTB - YPA

Possibility of controlling up to 16 indoor units.

Energy save and antifreeze function.

Weekly programmer built in.

Check and self diagnostics

Compatible with all indoor units except compact wall units.

Temperature sensor built in.

Simple use.

Slim, compact design.

Luminous background for use in the dark.

Especially recommended for hotels and offices.

Daily programmer built in.

Elevated reach and precision.

Energy save and sleep function.

Code selector to avoid confusion between indoor units.

Compatible with all indoor units except ducts.

Re

mo

te c

on

tro

lle

rs

164-165 ING 5/5/06 09:02 Página 164

Page 14: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

167166

VR

F c

on

tro

ls

UTB- YCA UTR - YOTA UTR - YTMB UTR - YLLA UTR - YLBA

3DGF9420 3DGF9430 3DGF9465 3DGF9455 3DGF9460

1.272 2.857 To consult To consult To consult

Code

Price Ref.

M o d e l s

Central remote control ler

UTB - YCA

Possibility of controlling up to 400 indoor units.

Weekly programmer built in.

Allows the individual control functions to be blocked.

Easy use.

Check and self diagnostics.

PC control ler

UTR - YOTA

Possibility of controlling up to 400 indoor units.

Annual programmer built in.

Allows the individual control functions to be blocked.

Calculation of electrical consumption of user groups.

Operation and fault register.

Check and self diagnostics.

Transmission adaptor

UTR-YTMB

Allows the VRF system to be managed from external centralised control (BMS).

Transfer adaptor for RS-232C communication.

Network convertor

UTR-YLLA

Allows the VRF system to be managed from external centralised control (BMS).

Transmission converter for communication with LONWORKS® networks.

Network convertor

UTR-YLBA

Allows the VRF system to be managed from external centralised controls (BMS), in accordance

with the ANSI/ASHRAE 135-2001 standard.

Transmission converter for communication with BACnet® networks.

Ce

ntr

ali

se

d c

on

tro

l s

ys

tem

s

U T B - Y C AC e n t r a l

r e m o t e c o n t r o l l e r

U T R - Y O TAP C c o n t r o l l e r

Tr a n s m i s s i o na d a p t o r

U T R - Y T M B

166-167 ING 5/5/06 09:09 Página 166

Page 15: VRF Range - uk.eurofred.com · VRF Range Outdoor unit Cassette Ducts Compact products Ducts Floor-ceiling Large Ceiling Wall Mounted Wall Ceiling The variable refrigerant flow system

169168

VRF System

Single Split / Big Multi

UTR-YSSA

VR

F a

cc

es

so

rie

s

Service tool UTR-YSTB

Signal amplif ier UTR-YRPA

Accessories

Network convertor UTR-YSSA

Ac

ce

ss

or

ies

Separator 2 x 90A pipes

For the heat pump series, when the sum

of indoor unit codes exceeds the value of 60.

Separator 2 x 54A pipes

For the heat pump series, when

the sum of indoor unit codes is

the same as or exceeds the value of 60.

Required when the transmission line exceeds

500 m or the number of units connected is

greater than 64.

Software that allows the operation of the VRF

system to be verified and analysed and any

anomaly to be detected.

Header 8 outlets, 2 x 908A pipes

For the heat pump series it is

possible to connect up to 8 indoor units.

Refrigerant Refrigerant Separator Separator Separator Separator

branch 4 branch 1 90R 90A 54R 54A

3DGF9300 3DGF9310 3DGF9320 3DGF9330 3DGF9340 3DGF9350

1.333 333 86 63 80 61

Unit Code

Price Ref.

Header Header Header Header UTR-YSSA UTR-YRPA UTR-YSTB

908R 908A 906R 906A

3DGF9360 3DGF9370 3DGF9380 3DGF9390 3DGF9435 3DGF9445 3DGF9475

183 152 179 150 410 667 To consult

Unit Code

Price Ref.

M o d e l s

Header 6 outlets, 2 x 906A pipes

For the heat pump series it is

possible to connect up to 6 indoor units.

Allows split or large room units

to be integrated to the VRF

control system.

Header 6 outlets, 3 x 906R pipes

Header 8 outlets, 3 x 908R pipes

54R 3 pipe separator

Refrigerant Branch unit-4way

For heat recovery. Required for the connection of the

indoor units to the pipes . Available for up to four

indoor units.

It is possible to connect up to 8 indoor units

for heat recovery series.

It is possible to connect up to 6 indoor units

for heat recovery series.

Refrigerant Branch unit-1way

For heat recovery. Required for the connection of the

indoor units to the pipes. It has a connection for an

indoor unit.

90R 3 pipe separator

For heat recovery, when the sum of indoor unit codes

exceeds the value of 60.

For heat recovery, when the sum of indoor unit

codes is the same as or exceeds the value of 60.

168-169 ING 5/5/06 12:37 Página 168