Teikoku Type F & FV

Chempump Modified NC Series

Standard Internal Circulation

Page 5: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Standard Internal Circulation

Page 6: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

APLICACIONES--IDEAL PARA FLUIDOS:

QUE NO ESTEN CERCANOS A SU PUNTO DE EBULLICION

--MANEJA FLUIDOS COMO:

ACIDO ACETICO

AMINA

ANILINA

DICLOROBENCENO

ETANOL

ETILBENCENO

ACIDO FORMICO

GASOLINA

MMA

ACIDO NITRICO

ACIDO SULFURICO

HIDROXIDO DE SODIO

BOMBA TIPO “FA”BOMBA TIPO “FA”

(CON FLECHA HUECA)

Page 7: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Vertical In-Line Reverse Circulation

Teikoku Type RW, RV, FW & FV

Page 8: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Vertical In-Line Reverse Circulation

Page 9: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

BOMBA TIPO “R” VERTICALIZADABOMBA TIPO “R” VERTICALIZADA(RECIRCULACION POSTERIOR)

Page 10: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

BOMBA TIPO “R” VERTICALIZADABOMBA TIPO “R” VERTICALIZADA(RECIRCULACION POSTERIOR)APLICACIONES

--IDEAL PARA FLUIDOS:

VOLATILES

GASES LICUABLES

QUE ESTEN CERCA O EN SU PUNTO DE EBULLICION

--MANEJA FLUIDOS COMO:

BUTANO

BUTADIENO

BUTENO

ETANO

METANO

PROPILENO

PROPANO

CLORURO DE VINIL

NITROGENO LICUADO

LIQUIDOS HIDROCARBUROS

Page 11: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Standard Reverse Circulation

Teikoku Type R & RA

Chempump Modified G & NC Series

Page 12: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Standard Reverse Circulation

Page 13: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

BOMBA HORIZONTAL TIPO “R”BOMBA HORIZONTAL TIPO “R”(RECIRCULACION POSTERIOR)

APLICACIONES

--IDEAL PARA FLUIDOS:

VOLATILES

GASES LICUABLES

QUE ESTEN CERCA O EN SU PUNTO DE EBULLICION

--MANEJA FLUIDOS COMO:

ACETALDEHIDOS

DIOXIDO DE CARBONO

DIETILAMINA

OXIDO DE ETILENO

OXIDO DE PROPILENO

PENTANO

HEXANO

FREON Y OTROS REFRIGERANTES

ACETATO DE VINIL

Page 14: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Teikoku Type D & DA

Chempump GS & NCS Series

For Water & Air Cooled Slurry Service

Isolated Motor Circulation

Page 15: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Isolated Motor Circulation

Page 16: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

BOMBA TIPO “D”BOMBA TIPO “D”(PARA MANEJO DE FLUIDOS CON SOLIDOS PEQUEÑOS)

APLICACIONES

--IDEAL PARA FLUIDOS:

CON EL 5% DE SOLIDOS EN SUSPENSION

--MANEJA FLUIDOS COMO:

ACIDO FLUORHIDRICO CONTAMINADO O HUMEDO

Page 17: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Standard Externally Cooled Motor Circulation

Teikoku Type B & BA

Chempump GT & NCT Series

For Water & Air Cooled High Temperature Service

Page 18: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Standard Externally Cooled Motor Circulation

Page 19: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

BOMBA TIPO “B”BOMBA TIPO “B”(PARA FLUIDOS ALTAS TEMPERATURAS)APLICACIONES

--IDEAL PARA FLUIDOS:

A ALTA TEMPERATURA, HASTA 450°C

--MANEJA FLUIDOS COMO:

ACEITE TERMICO

• THERMINOL

• DOWTHERM

• ESSOTHERM

MANUFACTURA DEL PTA.

PROCESO DE LA POLIMERIZACION DEL POLIESTER

PROCESO DE LA POLIMERIZACION DEL POLIESTIRENO

NYLON

FENOL

ACIDO MALEICO

Page 20: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Multi-Stage External Circulation

For High Discharge Pressure Service

Teikoku Type F-M

Page 21: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Multi-Stage External Circulation

Page 22: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

BOMBA TIPO “FM Y RM”BOMBA TIPO “FM Y RM”(BOMBA PARA ALTA PRESION)

APLICACIONES

--IDEAL PARA FLUIDOS:

CON CARGA DINAMICA TOTAL DE HASTA 1500 PIES

--MANEJA FLUIDOS COMO:

LOS ANOTADOS EN LAS BOMBAS TIPO “F” Y TIPO “R” A ALTAS PRESIONES

Page 23: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

MONITOR DE GUARDIAMONITOR DE GUARDIA

Page 24: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.
Page 25: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

OPCIONES DE SEGURIDAD

INSTALADO EN EL PANEL DE CONTROL COMOPARTE DE LA INSTALACION ELECTRICA. LA ALARMA DE BAJO FLUJO AUTOMATICAMENTECORTA EL SUMINISTRO DE ENERGIA, CUANDOLA BOMBA ESTA TRABAJANDO EN SECO.

TAMBIEN PROTEJE EL MOTOR DE LA BOMBA,CUANDO EXISTE CAVITACION.

TAMBIEN DETECTA SOBRECARGA DEL MOTOR EL IMPULSOR ESTE ATORADO O ATASCADOLOS BALEROS ESTAN OPERANDO MAL

TIPICAS APLICACIONES:1.- CARRO TANQUE DE DESCARGA2.- BOMBEO DESDE TANQUE DE ALMACENAMIENTO3.- OPERACIONES DE BATCH4.-CUALQUIER OTRA APLICACION DONDE LA BOMBA PUEDA FUNCIONAR EN SECO

RELEVADOR DE PARO A BAJO FLUJO

Page 26: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

OPCIONES DE SEGURIDAD

LA BOMBA PUEDE SER PROVISTA CON UNMEDIDOR DE TEMPERATURA Y UN DISPOSITIVO DE CONTROL.ESTE INSTRUMENTO PUEDE SER CALIBRADO, A LA TEMPERATURA LIMITE DESEADA YAUTOMATICAMENTE MANDAR UNA SEÑAL O APAGAR LA BOMBA CUANDO ESTE LIMITE HA SIDO EXCEDIDO.PUEDE SER INSTALADO EN LA LINEA DE ENFRIAMIENTO DEL MOTOR

CONTROL DE TEMPERATURA

Page 27: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

OPCIONES DE SEGURIDAD

TERMOSTATO

UN SENSOR DE TEMPERATURA EN EL DEVANADO DEL MOTOR ENLATADO ES PROVISTO PARA PREVENIR SOBRECALENTAMIENTOS. ESTOS TRABAJAN CUANDO EL DEVANADO DEL MOTOR ALCANZA LOS 220° C. LAS BOMBAS QUE SON EMBARCADAS A E.E.U.U., MEXICO Y CANADA TIENEN ESTE TERMOSTATO COMO ESTANDARD.

Page 28: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

NO LUBRICACION EXTERNANO LUBRICACION EXTERNA

EL FLUIDO BOMBEADO PROVEE ENFRIAMIENTO AL MOTOR Y LUBRICACION A LAS CHUMACERAS. NO NECESITA NIVELES DE ACEITE PARA CHECAR.

NO LUBRICACION EXTERNANO LUBRICACION EXTERNA

EL FLUIDO BOMBEADO PROVEE ENFRIAMIENTO AL MOTOR Y LUBRICACION A LAS CHUMACERAS. NO NECESITA NIVELES DE ACEITE PARA CHECAR.

NO GOTEANO GOTEA

PUEDE MANEJAR FLUIDOS TOXICOS, EXPLOSIVOS, VENENOSOS, VOLATILES, CANCERIGENOS Y CORROSIVOS SIN GOTEO.

Page 29: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

DISEÑO COMPACTODISEÑO COMPACTO

EL MOTOR Y LA BOMBA SON UNA SOLA UNIDAD, NO ES NECESARIO, EL ALINEAMIENTO.

OPERACIÓN SILENCIOSAOPERACIÓN SILENCIOSA

TIENE BAJO NIVEL DE RUIDO NO USA VENTILADOR, PARA ENFRIAR EL MOTOR.

Page 30: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

AIREAIRE

DISEÑADO PARA MANEJAR FLUIDOS QUE REACCIONAN CON EL AIRE.

NO REQUIERE SELLO MECANICONO REQUIERE SELLO MECANICO

CARACTERISTICA MAS IMPORTANTE YA QUE ES UNA BOMBA CERO FUGAS

Page 31: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

Mex Quip, S.A. de C.V. Delfina Flores No. 5602 Col. Del Maestro C.P. 64180 Monterrey, Nuevo León. Tel. Oficina Edo. de México: 55 58 73 51 19

Page 32: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

PARTES DE REPUESTOPARTES DE REPUESTO

Page 33: VISTA SECCIONADA Teikoku Type F & FV Chempump Modified NC Series Standard Internal Circulation.

ENSAMBLEENSAMBLEESTATORESTATOR

MATERIAL ESTANDARD ACERO INOXIDABLE 316L

INUNDADO DE NITROGENO

TERMOSTATO

MONITOR DE GUARDIA

AISLAMIENTO ESTANDARD CLASE “C”

AISLAMIENTO OPCIONAL PARA ALTA TEMPERATURA

3 FASES/60CICLOS/460VOLTS

ROTORROTOR MATERIAL ESTANDARD ACERO INOXIDABLE 316L

TIPO “F” CON FLECHA HUECA

ARANDELAS DE EMPUJEARANDELAS DE EMPUJE MATERIAL ESTANDARD ACERO INOXIDABLE 316

CARA CON CROMO ENDURECIDO

REDUCE LOS EMPUJES AXIALES

MANGAS DE FLECHAMANGAS DE FLECHA MATERIAL ESTANDARD ACERO INOXIDABLE 316

SE CONSIDERA PIEZA DE DESGASTE

CHUMACERASCHUMACERAS MATERIAL ESTANDARD CARBON GRAFITADO

ENCAUSA EL FLUIDO LUBRICANTE

CENTRA EL ROTOR EN EL ESTATOR

CHUMACERAS RANURADAS EN ESPIRAL

PARTE POSTERIORPARTE POSTERIOR(PORTA CHUMACERA TRASERA)

CUENTA CON RANURADO QUE ORIENTA EL FLUIDO DE ENFRIAMIENTO

EN OCASIONES, CUENTA CON VALVULA DE VENTEO

IMPULSORIMPULSOR TIPO CERRADO

BALANCEADO ESTATICAMENTE Ó DINAMICAMENTE E HIDRAULICAMENTE

DOBLE ORIFICIO EN SU PARTE POSTERIOR

NO CUENTA CON ANILLOS DE DESGASTE

VOLUTAVOLUTA BRIDAS 150 # R.F.

SE PUEDE SUMINISTRAR DE CUALQUIER MATERIAL (TITANIO, HASTELLOY “C”)

PORTA CHUMACERA DELANTERAPORTA CHUMACERA DELANTERA