Teikoku Rotary Guardian

18
1 Bearing Wearing Monitor for TEIKOKU CANNED MOTOR PUMP TRG (TEIKOKU ROTARY GURDIAN)

Transcript of Teikoku Rotary Guardian

Page 1: Teikoku Rotary Guardian

1

Bearing Wearing Monitor for TEIKOKU CANNED MOTOR PUMP

TRG (TEIKOKU ROTARY GURDIAN)

Page 2: Teikoku Rotary Guardian

(株)帝国電機製作所 2

Principle (Sensor Location)

A-A’ Sectional

Page 3: Teikoku Rotary Guardian

3

Principle Basic Wave A Groove Harmonics A

Compound Output     ( A +

B)

Groove Harmonics B

Page 4: Teikoku Rotary Guardian

4

Principle

a

b

Bearing Worn Out   a > b

TRG Indication gets Big

Page 5: Teikoku Rotary Guardian

5

Configuration & Option

• Sensor Coil• Anti-Rotating Detection

(Mold Circuit)• TRG Meter (Flame-Proof)• TRG Panel Meter (Option)• TRG Alarm (Option)• TRG Converter (Option)

Page 6: Teikoku Rotary Guardian

6

TRG Convertor

• TRG Signal is converted to 4-20(mA) or 1-5(V) which realizes centralized control.

• Flam Proof Explosion (d2G4) is available as option.

TRGコンバータ特性

4

6

8

10

12

14

16

18

20

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

TRG指示値

電流出力[mA]

1

1.5

2

2.5

3

3.5

4

4.5

5

電圧出力[V]

TRG Convertor Output

TRG Indication

(mA

)

(V)

Page 7: Teikoku Rotary Guardian

7

TRG Function

• Bearing Wearing Out

• 2-Phase Connection

• Wrong 3-Phase Connection Anti-Rotate

• Eccentric Assembly

• Unbalanced 3-Phase Amperage

• Unbalanced Induced Amperage on Rotor Defects

Page 8: Teikoku Rotary Guardian

8

TRG Indication at Start Up(With Anit-Rotating Detection)

Indication Root Cause Action

Full Scale Anti-Rotate Confirm Wire Assignment

Yellow~ Red 2(1) Phase Connection

Confirm Wire Connection

Green Good No

Page 9: Teikoku Rotary Guardian

9

TRG Indication during Running

Indication Condition Action

Green Safe No

Initial + 0.3Initial + 0.3

(Yellow)(Yellow)

CautionCaution Ready to Maintain

Initial + 0.5

(Red)

Danger Stop Pump

Initial TRG Value should be Recorded

Page 10: Teikoku Rotary Guardian

10

TRG Singnal

• With Anti-Rotating Detection (TRG Model : M, R) Diode Commutation, 350mVDC to Full Scale

• Without Anti-Rotating Detection (TRG Model : L, G) Raw TRG Signal AC1V to Full Scale Frequency < 3kHz

Page 11: Teikoku Rotary Guardian

11

Wiring to Outer Divices, TRG-Panel Meter, Alarm, and Convertor

• Wiring : Single Core Shielded Signal Wire 1.25mm2 or BiggerCore to G1 Terminal, Shield to G2 Terminal

• In case Double Core Wire is used, Core to G1 Terminal, Shield to G2 Terminal

• Shield must NOT be Grounded• Keep Away from Power Cable

Page 12: Teikoku Rotary Guardian

12

Wiring

TERMINAL BOX

TRG METER

TRG PANNEL METER

TRG ALARM

PANNEL

Shield must NOT be Grounded

Page 13: Teikoku Rotary Guardian

13

Other factors to vary TRG Indication

• Over LoadingSince TRG is sensing magnetic field generated by amperage on rotor, indication varies depending on loading.i.e. Flow Rate, SG, Viscosity,

• Ambient TemperatureDevises in TRG meter is affected by temperature but indication varies no more than 0.1 scale.

Page 14: Teikoku Rotary Guardian

(株)帝国電機製作所 14

誘導障害の確認

• 遠隔監視装置(パネルメータ、警報装置、TRGコンバータ)配線後 ,TRG指示値が黄色~赤色ゾーンであれば誘導障害の可能性があります。

• ポンプ端子台の G1,G2からシールド線の芯線及びシールドを外して運転し、端子箱のTRG指示値を確認して下さい。

• TRG指示値が黄~赤色→0.4以下になれば誘導障害を受けていることになります。

Page 15: Teikoku Rotary Guardian

(株)帝国電機製作所 15

誘導障害の対策

• 誘導障害を受けている場合、遠隔監視装置(パネルメータ、警報装置、TRGコンバータ)の入力 G1-G2間にダミー抵抗を入れてインピーダンスを下げてください。

• ダミー抵抗としては500 Ω~3 kΩ 1 /2W程度のものを用いてください。抵抗値は小さい方がよく効きます。

Page 16: Teikoku Rotary Guardian

(株)帝国電機製作所 16

インバータ駆動時のTRGについて• 回転方向検知付き(TRG型式:M ,R)の場合、インバータ駆動するとTRGは黄~赤色になり機能しなくなります。この場合、モールド回路を取り外す。メータや遠隔監視装置を交換するという作業が必要です。

↓• インバータ駆動する場合、回転方向検知無し(TRG型式:L ,G )を必ず選定してください。インバータのキャリア周波数は3 kHz以下で設定使用ください。

回転方向検知付きTRG選定不可!

キャリア周波数は必ず3 kH z以下に下げる

Page 17: Teikoku Rotary Guardian

(株)帝国電機製作所 17

インバータ駆動時のTRG管理についての注意事項

• TRGの管理の基本は、ある一定運転条件で初期値+ αの αがいくらになったかが管理の対象になります。(相対値管理)

• インバータ制御の場合、周波数一定にて管理をお願いします。 (例:50Hz 一定条件のTRG指示でチェックする)

Page 18: Teikoku Rotary Guardian

(株)帝国電機製作所 18

回転方向検知付きTRGの注意事項• TRG回路と主電源回路が非絶縁です。

• TRG回路が絶縁不良になった場合、漏電検知器が作動する可能性あり。またこの場合、TRG指示値も高くなります。

図1.回転方向検知付TRGR   S   T

パネル取付形メータ テ イ コ ク

TRGメータ(AM-45)

G1               G2G1         G2                        シ ー ル ト 線゙

回転方向検出回路(モールド回路)     端子箱

V                                         TRG巻線

Uモータ巻線                                                           ステータ