8/17/2019 Virtus II 305-320 4BB en 1509 and Australia Version
1/6
Virtus II Module 305-320W 4BB
ReneSola Australia Virtus II Module 310-320W
www.renesola.comin NYSE
Follow us
This document contains TDS for the following products:
-
8/17/2019 Virtus II 305-320 4BB en 1509 and Australia Version
2/6
Virtus®II Module
Safety Fire
Mechanical Load Capability of up to 5400 Pa
Applicaon Class A, Safety Class II, Fire Rang C
ISO9001, OHSAS18001, ISO14001 Cerfied
Conforms with IEC 61215:2005,
IEC 61730:2004, UL1703 PV Standards
Easy Installaon and Handling for Various Applicaons
High Module Conversion Efficiencies
ReneSola.com
G u a r a
n t e e
linear power
output
material &workmanship
100%
95%
90%
85%
80%
0%
25
8 0, 0 %
0 1
9 7, 5 %
5 1 0 15 20
P e r f o r m a n c e F i g u r e s i n %
Ad d e d V a l u e
YEAR
305W,310W, 315W, 320W
C US
Intertek
CM
TUVNORDCERT
GmbH
I E C 6 1 2
1 5 / 6 17 30-1/ 6 1
7 3 0 -
2
-
8/17/2019 Virtus II 305-320 4BB en 1509 and Australia Version
3/6
Container
Pallets per Container
Pieces per Container
20’ GP
10
250
40’ HQ
24
660
40’ GP
24
600
Cell Type
Glass
Frame
Dimension
Output Cable
Weight
Virtus II (Polycrystalline) 156 x156 mm, 72 (6x12) pcs in series
High Transmission, Low lron, Tempered Glass
Anodized Aluminum Alloy
IP65/IP67 Rated, With Bypass Diodes
*1956 x 992 x 40 mm
4 mm2 (EU)/12 AWG (US), 1200 mm
27 kg
See Drawing Above
Maximum System Voltage
-40oC ~ +85oC
1000VDC (EU) / 600VDC (US)
20A (EU) / 20A (US)
Temperature Coefficient of Voc
Temperature Coefficient of Isc
Temperature Coefficient of Pmax
JC310M-24/Abs
310 W
0 ~ +5W
16.0%
8.38 A
37.0 V
8.80 A
45.0 V
JC310M-24/Abs
230 W
6.80 A
33.8 V
7.10 A
42.1 V
Maximum Power (Pmax)
Power Tolerance
Module Efficiency
Maximum Power Current (lmp)
Maximum Power Voltage (Vmp)
Short Circuit Current (lsc)
Open Circuit Voltage (Voc)
Maximum Power (Pmax)
Maximum Power Current (lmp)
Maximum Power Voltage (Vmp)
Short Circuit Current (lsc)
Open Circuit Voltage (Voc)
Virtus®II Module
40mm
Drawing Only for Reference
-0.30%/oC
0.04%/oC
-0.40%/oC
45oC 2oC+ _
ReneSola.com
C u r r e n t ( A )
Voltage(V)
1 1 7 6 m m
1 6 7 6 m m
1 2 0 0 m m
947mm
JUNCTION BOX
LABEL
16-8X3.5
2-Ø4
INSTALLING HOLE
VENT HOLE
GROUNDING HOLE
4-7.5X7.5/2
DRAIN HOLE
8-6.5X10
Re
310W, 315W, 320W
992mm
1 9 5 6 m m
JC315M-24/Abs
315 W
0 ~ +5W
16.2%
8.45 A
37.3 V
8.88 A
45.4 V
JC315M-24/Abs
234 W
6.88 A
34.0 V
7.16 A
42.5 V
Value m2, Cell Temperature 25oC)
Value W/m2, AM1.5, Ambient Temperature 20oC, Wind Speed 1m/s.
JC320M-24/Abs
320 W
0 ~ +5W
16.5%
8.56 A
37.4 V
9.00 A
45.6 V
JC320M-24/Abs
238 W
6.96 A
34.2 V
7.26 A
42.7 V
0 10 20 30 40 50
0
2
4
6
8
10
200W/m2
400W/m2
600W/m2
800W/m2
1000W/m2
JC305M-24/Abs
305 W
0 ~ +5W
15.7%
8.33 A
36.6 V
8.73 A
44.9 V
JC305 M-24/Abs
226 W
6.72 A
33.6 V
7.04 A
42.0 V
-
8/17/2019 Virtus II 305-320 4BB en 1509 and Australia Version
4/6
-
8/17/2019 Virtus II 305-320 4BB en 1509 and Australia Version
5/6
-
8/17/2019 Virtus II 305-320 4BB en 1509 and Australia Version
6/6
Contacts:
Global Headquarters & Asia
Add: 15F, Manpo int’l Plaza,
No. 500, West Yan’an Road,
Shanghai, China 200050
T: +86 21 62809180
F: +86 21 62805600
Australia
Add: 51 Barry Street, Bayswater
Victoria 3153, Melbourne T: +61 1300 700 788
Europe
Add: Lyoner Straße 15
60528 Frankfurt am Main, Germany
T: +49 (0) 69 663 78 69 00
Africa
Add: Unit 2, Rambo Junction,
400 Roan Crescent, Midrand,
1685, South Africa
T: (+27) 010 006 0200
Americas
Add: 1300 Clay Street, Suite 550,
Oakland, CA 94612
T: +(415) 852 7421