VARIODYN D1 Webinar – Product training Michael Köhler International Business Development.
-
Upload
stacy-leet -
Category
Documents
-
view
369 -
download
22
Transcript of VARIODYN D1 Webinar – Product training Michael Köhler International Business Development.
Honeywell Proprietary
Honeywell.com
2
Document control number
Your Contact:
Michael Köhler
Business Development International VA/PA
Novar GmbH a Honeywell Company
Dieselstr. 2
41469 Neuss, Germany
www.esser-systems.de
Mobile: +49 174 33 56 531
Honeywell Proprietary
Honeywell.com
3
Document control number
Welcome!
CoModerator today:
The Presentation will be available as download later
Axel Hillmann (Lead Sales Support Administration)
Honeywell Proprietary
Honeywell.com
4
Document control number
Please ask your question in the chat window:
Your questions will be not forwarded to others
Honeywell Proprietary
Honeywell.com
8
Document control number
VARIODYN D1 - Components
• Digital Output Module with 8 loudspeaker lines DOM4-8Digital Output Module with 24 loudspeaker lines DOM4-24
• Digital Call station DCS15
• Universal Interface Module UIM
• System Communication Unit SCU
• Digital Power Amplifier• 2x250W (Class D) 2XD250• 2x400W (Class D) 2XD400
• Analog Power • 2x200W to 2x500W
Honeywell Proprietary
Honeywell.com
10
Document control number
DOM4-8
DOM4-24
For connection to max. 4 amplifier channels, 2 lines each
For connection to max. 4 amplifier channels, 6 lines each
Digital Output Module
Honeywell Proprietary
Honeywell.com
11
Document control number
Digital Output Module
ethernet
DAL-Bus
DSP Sound Processing
Volume Control High/Low Pass Delay EQ CS Limiter 276 s On-Board DVA
DO
M
Alert-Signals
Honeywell Proprietary
Honeywell.com
12
Document control number
Digital Output Module DOM 4-24
2XD
PA 1
2XD
PA 2
ethernet
DAL-Bus
DO
M
AMP-Monitoring
4x RR
DOM 4-24
24x LR
LINE-Monitoring
UIM
Honeywell Proprietary
Honeywell.com
13
Document control number
Digital Output Module DOM 4-8
2XD
PA 1
2XD
PA 2
ethernet
DAL-Bus
DO
M
4x RR
DOM 4-8
8x LR
AMP-Monitoring
LINE-Monitoring
UIM
Honeywell Proprietary
Honeywell.com
14
Document control number
ethernet
DAL-Bus
UIM
DO
M
Digital Output Module DOM 4-24
2XD
PA 1
2XD
PA 2
AMP-Monitoring
4x RR
DOM 4-24
24x LR
LINE-Monitoring
DO
M2X
D
Backup amplifier
Honeywell Proprietary
Honeywell.com
15
Document control number
2XD
Modular concept
2XD
DO
M2X
D2X
DD
OM
DO
M2X
D
2XD
2XD
DO
M2X
D2X
DD
OM
DO
M2X
D2X
D
2XD
2XD
DO
M
Rack 1 Rack 3Rack 2
Honeywell Proprietary
Honeywell.com
16
Document control number
2XD
Backup Organization (DOM 4-8)
2XD
DO
M2X
D2X
DD
OM
DO
M2X
Done DOM 4-8 +one Backup Amp =Backup for 2 other‘s DOMs
Honeywell Proprietary
Honeywell.com
17
Document control number
2XD
Backup Org. (DOM 4-24) – Dynamic!
2XD
2XD
DO
M2X
D2X
DD
OM
2XD
2XD
DO
MD
OMone DOM 4-24 +
one Backup Amp =Backup for 6 other‘s DOM
Honeywell Proprietary
Honeywell.com
18
Document control number
2XD
Backup Organization
2XD
DO
M2X
D2X
DD
OM
DO
M2X
D2X
D
backup
working
Honeywell Proprietary
Honeywell.com
19
Document control number
2XD
2XD
DO
M2X
DD
OM
MSU
UIM
Ethernet(*)
Back up organization
Ethernet
Ethernet
BackupRC22
BackupRC22
100 V cable(e.g.: 300 m distance (total cable length) 2x 2x4 mm2 for 250 W amp!)
Ethernet
BackupRC22 Etherne
t
BackupRC22
2XD
2XD
DO
MM
SU
2XD
2XD
DO
M2X
DD
OM
MSU
UIM
2XD
2XD
DO
MM
SU
2XD
DO
M (*) This mean a complex infrastructure, not a single copper cable; or a fiber
~ 300 Meter
Backup
Backup
Honeywell Proprietary
Honeywell.com
22
Document control number
Intercom between call stations
OCC Gate A
Gate BGate C
Honeywell Proprietary
Honeywell.com
23
Document control number
For one DCSF 12 or DCSF 1 (584961)
orFor two DCSF 12 or DCSF 1Or one DCSF and one DKM18
(584962)
New Call Station Housing 584961/62
Honeywell Proprietary
Honeywell.com
24
Document control number
Simple call station DIGIM1 and DIGIM4
Honeywell Proprietary
Honeywell.com
25
Document control number
Simple call station DIGIM1 and DIGIM4
1 2 3 Max 40
Honeywell Proprietary
Honeywell.com
26
Document control number
Simple call station DIGIM1 and DIGIM4
- 1 or 4 button call station
- max. 4 different zone’s each UIM Input
- up to 40 call stations in total each UIM Input
- One call in the same time / UIM input
- No call stacker function
- Daisy chain or star cabling possible
Honeywell Proprietary
Honeywell.com
28
Document control number
Digital Power Amplifier:2x250W (Class D) 2XD2502x400W (Class D) 2XD400
Power Amplifier
Honeywell Proprietary
Honeywell.com
29
Document control number
2XD250 and 2XD400
• More stable design (low thermal factors)• Higher reliability (no or low ventilation)• Less maintains (less dust inside)• Low BTU (heating) • Low power consumption
> For the amp it self and for rack cooling!• Honeywell developed
Honeywell Proprietary
Honeywell.com
31
Document control number
Ethernet
• Ethernet is THE world wide standard for Network• Components can be installed anywhere• Using Ethernet vs. proprietary cabling(*) means reducing :
– design cost – cabling cost– training efforts – using existing cables – lower the cable length of loudspeaker lines
(*) Including also CobraNet, which is a small Standard
Honeywell Proprietary
Honeywell.com
32
Document control number
Ethernet
• the number of announcements is limited by the available bandwidth (0,5 MBit per announcement)
In a 100Mbit Network < 100 channels• the network is permanently monitored• Up to 250 DOMs in one network
Honeywell Proprietary
Honeywell.com
33
Document control number
UIM, audio inputs
Analogue audio inputs
- via UIM (2x Line)
- via DCS15 (1x Line)
Configuration
LANTCP-IP
CD-Player
CD-Player
Analogue audio outputs
- via UIM (2x)
- via DCS15 (1x)
Audio in- and outputs
Honeywell Proprietary
Honeywell.com
34
Document control number
Digital I/O Contacts
Control contacts UIM
- 48 contacts
LANTCP-IP
BMZ oder z.B.VARIODYN 3000
System
Control outputs DOM- 8 configurable outputs
- Usable as In- or Outputs
8xControl contacts CIM- 8 contacts- Usable as In- or Outputs
UIM/CIM
DOM
Honeywell Proprietary
Honeywell.com
35
Document control number
- 16 memory places- overall 260 sec. per DOM
Audio memory SCU
- More than 60 channels simultaneously playable- Storage capacity of approx. 120 min for alarm messages- 60000 memory spaces- Storage capacity of approx. 1000 hours for less critical messages like commercial messages
Audio memory
LANTCP-IP
Audio memory DOM
Audio Memory
Honeywell Proprietary
Honeywell.com
36
Document control number
DAL, audio signal processing
Audio signal processing
CD-Player
Per audio stream on DAL-Bus- Volume- Configurable limiter for microphones (DCS, DCSF)
Configuration
LANTCP-IP
Audio Signal Processing
Honeywell Proprietary
Honeywell.com
37
Document control number
PA, audio signal processingCD-Player
Per power amplifier channel- Volume- High-pass 2nd, 4th, 6th order (Frequency response: -20Hz-20kHz)- Low-pass 2th, 4th, 6th order (Frequency response: -20Hz-20kHz)- Delay (0-2000msec)- Parametric Equalizer, 8 Bands
Configuration
LANTCP-IP
Audio Signal Processing
Honeywell Proprietary
Honeywell.com
38
Document control number
Volume control, AVCCD-Player
Audio memory
- via buttons, contacts- time-controlled, e.g. lower volume at tram stations during nighttime- Control commands via PC
- Automatic (AVC) by using sensor microphones also background music
Configuration
LANTCP-IP
Volume Control
Honeywell Proprietary
Honeywell.com
39
Document control number
BMZ oder z.B.VARIODYN 3000
System
- Serial to Notifier- Serial to Esser Fire Panels- Serial to BacNet via Multiprotokoll Gateway- Via LAN to any other System (VARIODYN PA-Protokoll)
LANTCP-IP
?
Interfaces
Honeywell Proprietary
Honeywell.com
41
Document control number
• Just two U heigh• VARIODYN D1 Design• Up to 210A(!) power on 24 Volt• 3 single protected 24V outputs for 3 DOM‘s• 6 single protected 24V outputs for 6 amp‘s• EN54-4 certified
VARIODYN D1 - UPS
Honeywell Proprietary
Honeywell.com
43
Document control number
• Graphical programming platform
• Easy, intuitive handling
• Programming of
• In- and Outputs
• Time triggers
• Contact closures
• etc
D1 Designer
Honeywell Proprietary
Honeywell.com
45
Document control number
VARIODYN D1
PIDSPIDS Alarm System
Alarm System
Communi-cation System
Communi-cation System
3rd party PA Systems
3rd party PA Systems
ETH
ETHETH
ETH
Configuration
ETH
DAL
DAL
DAL
ETH
ETH
DAL
ETH
DAL
CD Player
DAL
DAL
Graphical User InterfacePAMMI
DCS15
DCS15
DCS15
DCS15
DCS15
ETH
DAL
otherSystems
otherSystems
ETH
DCS15
Digital audio storage
LAN TCP-Transport
LAN TCP-Transport
Honeywell Proprietary
Honeywell.com
48
Document control number
DOM
AMP
BackupAMP
UIM
583491 amplifier cable
583477.21 amplifier output cable
583422.21RC 22 backup cable
DOM
AMP
AMP
583486 1 Meter CAT 5 network cable (or 583487/88 = 2/3 Meter)
583481 1Meter CAT 5 DAL Bus cable (or 583482/83 = 2/3 Meter)
D1 Cabling
Honeywell Proprietary
Honeywell.com
51
Document control number
VARIODYN D1 - Key Features
• Minimum number of components• Easy to design• Fully monitored in real time• Interface to fire panels• Network based and scalable• High quality audio• GUI including DVA
Honeywell Proprietary
Honeywell.com
52
Document control number
VARIODYN D1 - Key Features
• More than 50 simultaneous channels • Intercom (full duplex) between call stations• Time triggered internal events• Quick cabling and installing• EN 60849 compliant• EN 54-16 certified
Honeywell Proprietary
Honeywell.com
53
Document control number
Check Out!
Our Webinar’s about
acoustics basics I + II
and
PAMMI and others
Frequency (logarithmic scale)
Lev
el
20Hz 200Hz 2kHz 20kHz
160Hz 10kHz