VAJ CORTEC

6
Our policy is one of continuous development. Accordingly the design of our products may Whilst every effort is made to produce up to date literature, this document should only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. We cannot be held responsible for any reliance on any decisions taken on its contents without specific advice.

description

VAJ

Transcript of VAJ CORTEC

Page 1: VAJ CORTEC

Our policy is one of continuous development. Accordingly the design of our products may change at any time. Whilst every effort is made to produce up to date literature, this document should only be regarded as a guide and is

intended for information purposes only.

Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. We cannot be held responsible for any reliance on any decisions taken on its contents without specific advice.

Page 2: VAJ CORTEC

CORTEC

Page 2 document.xls 04/08/2023

Ordering informationVariants Order No. Trip Relay 20 contacts maximum VAJ ACaseAvailable in 1/4 non drawout case 10 / 15 terminals Y FAvailable in 1/2 non drawout case 20 terminals Z GAvailable in 1 1/2 drawout case 48 terminals S FTypeHand Reset With out coil supervision terminal - VAJH HHand Reset With coil supervision terminal - VAJHM HMSelf Reset With out coil supervision terminal - VAJS SSelf Reset With coil supervision terminal - VAJSM SMElectrical Reset - VAJC CBurdenLow Burden AHigh Burden BFlag - With Hand Reset FlagWith Flag BWith out Flag A

VAJH13 in YF Case-1/4N V 10T, Low / High Burden, With Flag 13 Y FVAJHM13 in YF Case-1/4N V 15T, High Burden, With Flag 13 Y FVAJS13 in YF Case-1/4N V 10T, Low Burden, With / With out Flag 13 Y F4 N\O Standard Contacts 0 0 0 03 N\O & 1 N\C Standard Contacts 0 0 0 12 N\O & 2 N\C Standard Contacts 0 0 0 2VAJC11 in ZF Case-1/2N H 20T, Low Burden, With Flag 11 Z FVAJC11 in BF Case-1D V 20T, Low Burden, With Flag 11 B FVAJH23 in ZG Case-1/2N H 20T, Low & High Burden, With Flag 23 Z GVAJHM23 in ZG Case-1/2N H 20T, High Burden, With Flag 23 Z GVAJS23 in ZG Case-1/2N H 20T, High Burden, With / Without Flag 23 Z G8 N\O Standard contacts 0 0 0 07 N\O & 1 N\C Standard Contacts 0 0 0 16 N\O & 2 N\C Standard Contacts 0 0 0 25 N\O & 3 N\C Standard Contacts 0 0 0 34 N\O & 4 N\C Standard Contacts 0 0 0 4VAJHM33 in SF Case- 1-1/2D V 48T, High Burden, with Flag,110/125, 220/250 V DC 33 S F12 N\O Standard contacts 0 0 0 010 N\O & 2 N\C Standard Contacts 0 0 0 28 N\O & 4 N\C Standard Contacts 0 0 0 46 N\O & 6 N\C Standard Contacts 0 0 0 6VAJSM43 in SF Case-1-1/2D V 48T, Low Burden, With / With out Flag 110/125, 220/250 V DC 43 S F18 N\O Standard contacts 0 0 0 015 N\O & 3 N\C Contact Standard 0 0 0 3VAJHM53 in SF Case-1-1/2D V 48T, High Burden 110/125, 220/250 V DC 53 S F20 N\O Standard contacts 0 0 0 018 N\O & 2 N\C Standard Contacts 0 0 0 216 N\O & 4 N\C Standard Contacts 0 0 0 414 N\O & 6 N\C Standard Contacts 0 0 0 612 N\O & 6 N\C Standard Contacts 0 0 0 810 N\O & 10 N\C Standard Contacts 0 0 1 0Voltage Rating OptionsUnit RL1 & RL224/27 Vdc 0 0 0 030/34 Vdc 0 2 5 048/54 Vdc 0 5 0 0110/125 Vdc 0 7 5 0220/250 Vdc 1 0 0 0110/125 Vac Low burden only 5 7 5 0220/250 Vac Low burden only 6 0 0 0IssueFactory Defined A

Page 3: VAJ CORTEC

document.xls CONFIGURATOR

Page 3 document.xls 04/08/2023

Trip Relay Type VAJ, with Hand reset / self reset contact & Hand reset Flag

1-3 4-5 6-7 8-9 10 13 14 15 16

Trip Relay VAJ H 23 ZG 5750 A B ARelay Type

H

Case Size

ZG

Contacts

23

Contact Arrangement

0

5750Burden

A

Aux Voltage Rating plus

575

Flag

BIssue A

Page 4: VAJ CORTEC

Master Text

Page 4 document.xls 04/08/2023

Variant : VAJH23ZG5750ABA

Master Data Text

Trip Relay VAJH23Hand Reset Contact With out coil supervision terminal and With out Flag Indicator

CASE :

Supply Voltage :

Contacts :

Burden :

External Documents

Outline Wrapper :Customer Wiring Diagram :

IssueVersion : A

BC

Page 5: VAJ CORTEC

Master Text

Page 5 document.xls 04/08/2023

VAJH23ZG5750ABA

Master Data Text

Hand Reset Contact With out coil supervision terminal and With out Flag Indicator

ZG

110/125 Vac

8 N/O

Low Burden

External Documents

MFM01701VAJH23ZG 002

Original - 22/03/2010Revision - 10/07/2010Revision - 19/07/2010