![Page 1: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/1.jpg)
Utility System OperationPresented by
Scott Peele PE
![Page 2: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/2.jpg)
Utility Power System
Utility System OverviewTransmission SystemDistribution System
How the System WorksTransmissionDistribution
Why It Works That WayDesign PhilosophyEvents & Causes
![Page 3: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/3.jpg)
Transmission System OverviewHigh Voltage
500 kV230 kV115 kV
Purchased Right-of-WayWideClearedUtility Has Some Control
Few AttachmentsVery ReliableFew Disturbances
![Page 4: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/4.jpg)
Distribution System Overview
Medium Voltage23 kV12 kV
Constructed Along Public Roads
Other Utility AttachmentsLess Clearance to TreesMore Public AccessMore Exposure
Most Customers Served This WayMore Disturbances
![Page 5: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/5.jpg)
System Design Philosophy
Protect Transmission & Distribution Lines and EquipmentMinimize Number of Extended OutagesMinimize Number of Customers Out Due to a FaultTrade-off is More Short Duration Events Automatic Reclosing Feeder
Breakers at a T-D Substation
![Page 6: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/6.jpg)
Protective Coordination Equipment
Automatic Reclosing Circuit Breakers
Transmission & Distribution
Automatic Line ReclosersDistribution System
Fuses - (Fused Cut-Outs)Mostly On Distribution
Grounding & BondingCritical for Safety & Protection
Lightning ArrestorsLimit Voltage, Divert Current
![Page 7: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/7.jpg)
Automatic Three Phase Line Recloser
![Page 8: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/8.jpg)
Single Phase Line Reclosers
![Page 9: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/9.jpg)
Three Phase Dip Pole Fuse
![Page 10: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/10.jpg)
Tap Line Fuse - Fused Cutout
![Page 11: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/11.jpg)
Faults cause voltage sags, interruptions and outages
SagInterruptionOutage
SagInterruptionOutage
Magnitude and DurationMagnitude and Duration Duration
- 10% and <1 minute- 90% and < 1 minute> 1 minute
![Page 12: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/12.jpg)
Simplified Transmission & Distribution System
Transmission @ 115 kV
Transformer
Distribution @ 23 kV
23 k
V Fe
eder
FeederBreaker
Transmission to DistributionSubstation
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
Transformer
Customer Substation
![Page 13: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/13.jpg)
Fault On Transmission System
Fault
Transmission @ 115 kV
Transformer
Distribution @ 23 kV
23 k
V Fe
eder
FeederBreaker
Transmission to DistributionSubstation
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
Transformer
Customer Substation
![Page 14: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/14.jpg)
Fault On Transmission SystemVo
ltage
All customers (transmission and distribution) served by the faulted transmission line will experience a short Voltage Sag.Customers served by other transmission lines which connect to the faulted transmission line may also experience a voltage sag.Depending on the configuration of the transmission line, some customers may experience a Momentary Interruption while a fault is clearing.
![Page 15: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/15.jpg)
Fault On Transmission Line
480
Fault occurs here
0
Volta
ge
Time
Breaker opens here
Breaker recloses here
Fault cleared
0
4 cycles(~0.067 sec)
![Page 16: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/16.jpg)
Four Cycle Voltage Sag
![Page 17: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/17.jpg)
Causes of Faults on the System
![Page 18: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/18.jpg)
Simplified Utility System
115 kV Substation
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
Transmission @ 115 kV
Transformer
Distribution @ 23 kVRegulator
23 k
V Fe
eder
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
CustomerCustomer
Customer
FuseFuse
FuseFuse
Fuse
Fuse
FeederBreaker
23 k
V Fe
eder
![Page 19: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/19.jpg)
Example
![Page 20: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/20.jpg)
Simplified Utility System
115 kV Substation
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
Transmission @ 115 kV
Transformer
Distribution @ 23 kVRegulator
23 k
V Fe
eder
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
CustomerCustomer
Customer
FuseFuse
FuseFuse
Fuse
Fuse
FeederBreaker
23 k
V Fe
eder
Outage
Momentary Interruption
Sag
![Page 21: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/21.jpg)
Fault On Your Feeder
115 kV Substation
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
Transmission @ 115 kV
Transformer
Distribution @ 23 kVRegulator
23 k
V Fe
eder
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
CustomerCustomer
Customer
FuseFuse
FuseFuse
Fuse
Fuse
FeederBreaker
23 k
V Fe
eder
Outage
Momentary Interruption
![Page 22: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/22.jpg)
Fault On Your Feeder
480
Fault occurs here
0
Volta
ge
Time
Recloser opens here
recloses here
Fault cleared
0
7 cycles(~0.1 sec)
13 cycles(~0.2 sec)
~ 1/3 second
![Page 23: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/23.jpg)
Voltage Sag & Momentary Interruption
Breaker Tripped
![Page 24: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/24.jpg)
![Page 25: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/25.jpg)
Squirrel Guard
![Page 26: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/26.jpg)
Fault On Adjacent Feeder
Transformer480 V
Transformer480 V
115 kV Substation
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
Transmission @ 115 kV
Transformer
Distribution @ 23 kVRegulator
23 k
V Fe
eder
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
CustomerCustomer
Customer
FuseFuse
FuseFuse
Fuse
Fuse
FeederBreaker
23 k
V Fe
eder
OutageSag
![Page 27: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/27.jpg)
Fault on Adjacent Feeder
480
Fault occurs here
0
Volta
ge
Time
Breaker opens here
Breaker recloses here
Fault cleared
0
7 cycles(~0.117 sec)
![Page 28: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/28.jpg)
Voltage Sag Due To Momentary Fault On Adjacent Feeder
![Page 29: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/29.jpg)
Fuse Blow and Breaker Operation Due to Fault On Adjacent FeederTransmission @ 115 kV
Transformer
Distribution @ 23 kV
23 k
V Fe
eder
FeederBreaker
115 kV SubstationRegulator
23 k
V Fe
eder
Transformer480 V
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
Fault
Customer
Fuse
![Page 30: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/30.jpg)
Open or Blown Fused Cutout
![Page 31: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/31.jpg)
Voltage Sag Due To Momentary Fault On Adjacent Feeder
480
Fault occurs here
0
Volta
ge
Time
Breaker opens here
Breaker recloses here
Fault clearedBy Fuse
0
7 cycles(~0.117 sec) .3 to 2 seconds
![Page 32: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/32.jpg)
Fuse Blow and Breaker Operation Due to Fault On Adjacent Feeder
150.0V
75.0V
0.0V105.83 ms/div0sec 2.12sec
RMS Sag Disturbance PQPager/3100 PQNode
Silverline Plastics 10/26/97 06:44:49.00 PM
Three Phase Wye
2V
![Page 33: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/33.jpg)
Permanent Fault On Distribution Feeder
Transmission @ 115 kV
Transformer
Distribution @ 23 kV
23 k
V Fe
eder
FeederBreaker
115 kV SubstationRegulator
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
PermanentFault
![Page 34: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/34.jpg)
Voltage During Permanent Fault
480
Fault occurs
0
Volta
ge
Time
open
lockout after3 tries
0
clos
e
open
clos
e
~ 1 minute
7 cycles
13 cycles 15 seconds 35 seconds
.3 - 2.0 seconds
10 seconds
clos
e
open
Ope
n
![Page 35: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/35.jpg)
Fault On Adjacent Feeder
Transmission @ 115 kV
Transformer
Distribution @ 23 kV
23 k
V Fe
eder
FeederBreaker
115 kV SubstationRegulator
23 k
V Fe
eder
Transformer480 V
Customer
Transformer480 V
Transformer480 V
Transformer480 V
Customer Customer
Customer
Fuse Fuse
Fuse Fuse
Fuse
Fuse
FeederBreaker
PermanentFault
![Page 36: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/36.jpg)
Voltage During Permanent Fault on an Adjacent Feeder
480
Fault occurs
0
Volta
ge
Time
lockout after3 tries
0
~ 1 minute
7 cycles
12 cycles
15 seconds35 seconds
.3 - 2.0 seconds
open
clos
e
open
clos
e
clos
e
open
Ope
n
10 seconds
![Page 37: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/37.jpg)
Time
Quick Trip
6-12 cycles
.3 - 2.0 seconds
13 cycles 15 seconds 35 seconds
lockout
Load Current
FaultInitiated
FaultCurrent
13 cycles
13 cycles
6-12 cycles
6-12 cycles
15 seconds
15 seconds
35 seconds
35 seconds
.3 - 2.0 seconds
.3 - 2.0 seconds
Faulted Feeder
Adjacent Feeder
100%
0%
100%
0%
Voltage
Voltage
FeederBreakerOperation
Substation Voltages During a Feeder Fault
68% Cleared on FirstQuick trip
27% Cleared on Secondand Third Relay
5% Goes to Lock Out
![Page 38: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/38.jpg)
Single Line of Substation
![Page 39: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/39.jpg)
Utility Protection Coordination Schemes & Equipment
Fuse Save SchemeFuse Blow SchemeElectronic RecloserHydraulic RecloserUnderground NetworkElectronic Sectionalizer
![Page 40: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/40.jpg)
Capacitor BanksElectrical utilities use capacitor banks for power factor correction and voltage support.Capacitors are used to meet the reactive power requirements of inductive loads such as motors.Switching capacitors can produce oscillatory transients which may cause tripping of adjustable speed drives.
![Page 41: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/41.jpg)
Capacitor Bank Switching Transient
![Page 42: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/42.jpg)
Line Capacitor Bank
![Page 43: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/43.jpg)
Line Capacitor Bank
![Page 44: Utility System Operation - Progress Energy IncUtility System Operation Presented by Scott Peele PE. Utility Power System OUtility System Overview ZTransmission System ... Protection](https://reader030.fdocuments.net/reader030/viewer/2022040918/5e9381b3d319c2202813e797/html5/thumbnails/44.jpg)
Utility’s Power SystemUtility System Overview
Transmission SystemDistribution System
How the System WorksTransmissionDistribution
Why It Works That WayDesign PhilosophyEvents & Causes
Questions?