22
PLTC 300 VOLT UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, 300 Volts APPLICATIONS: For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. SPECIFICATIONS: 1. CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105˚C polyvinyl chloride (PVC). 3. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 4. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT 4 and UL 1581 vertical tray flame tests. 5. TEMPERATURE: 105˚C 6. VOLTAGE: 300 Volts Conductor Size Number Nominal O.D. Approximate Anixter of Weight Lbs. Number AWG Conductors IN 1000 Ft. 323-011-2201-B 22 2 0.20 19 323-011-2001-B 20 2 0.21 23 323-011-1801-B 18 2 0.23 28 323-011-1601-B 16 2 0.26 37 323-011-1401-B 14 2 0.32 60 323-011-1201-B 12 2 0.42 95 323-012-2203-B 22 3 0.21 24 323-012-2003-B 20 3 0.23 28 323-012-1803-B 18 3 0.25 37 323-012-1603-B 16 3 0.27 50 323-012-1403-B 14 3 0.34 80 Color Code for two conductor: Black and Red. Color Code for three conductor: Black, Red and White. 13-1 ©Anixter Inc. 1999 1-800-ANIXTER

Transcript of UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC...

Page 1: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

UNSHIELDEDMULTI CONDUCTOR

PVC InsulationPVC Jacket105˚C, 300 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725.

SPECIFICATIONS:1. CONDUCTORS: Stranded, tinned copper.2. INSULATION: 105˚C polyvinyl chloride (PVC).3. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC).4. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13.

Finished cable passes CSA FT 4 and UL 1581 vertical tray flame tests.5. TEMPERATURE: 105˚C6. VOLTAGE: 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Conductors IN 1000 Ft.

323-011-2201-B 22 2 0.20 19323-011-2001-B 20 2 0.21 23323-011-1801-B 18 2 0.23 28

323-011-1601-B 16 2 0.26 37323-011-1401-B 14 2 0.32 60323-011-1201-B 12 2 0.42 95

323-012-2203-B 22 3 0.21 24323-012-2003-B 20 3 0.23 28323-012-1803-B 18 3 0.25 37

323-012-1603-B 16 3 0.27 50323-012-1403-B 14 3 0.34 80

Color Code for two conductor: Black and Red.Color Code for three conductor: Black, Red and White.

13-1©Anixter Inc. 1999 1-800-ANIXTER

9004S13A.QXD 6/9/99 2:24 PM Page 1

Page 2: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

13-2 ©Anixter Inc. 19991-800-ANIXTER

PLTC 300 VOLT

SHIELDEDMULTI CONDUCTOR

PVC InsulationPVC Jacket105˚C, 300 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725.

SPECIFICATIONS:1. CONDUCTORS: Stranded, tinned copper.2. INSULATION: 105˚C polyvinyl chloride (PVC).3. ASSEMBLY: Cabled with an overall aluminum mylar shield and stranded tinned copper

drain wire.4. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC).5. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13.

Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests.6. TEMPERATURE: 105˚C7. VOLTAGE: 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Conductors IN 1000 Ft.

323-023-2201-B 22 2 0.20 25323-023-2001-B 20 2 0.22 25323-023-1801-B 18 2 0.24 33

323-023-1601-B 16 2 0.26 38323-023-1401-B 14 2 0.33 70323-023-1201-B 12 2 0.43 112

323-024-2203-B 22 3 0.21 27323-024-2003-B 20 3 0.23 32323-024-1803-B 18 3 0.25 41

323-024-1603-B 16 3 0.28 56323-024-1403-B 14 3 0.35 90

Color Code for two conductor: Black and Red.Color Code for three conductor: Black, Red and White.

9004S13A.QXD 6/9/99 2:24 PM Page 2

Page 3: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

OVERALL SHIELDEDSINGLE AND MULTI PAIR

PVC InsulationPVC Jacket105˚C, 300 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725.

SPECIFICATIONS:1. CONDUCTORS: Stranded, bare copper.2. INSULATION: 105˚C polyvinyl chloride (PVC).3. PAIRS: Pairs are twisted with a suitable lay to reduce magnetic interference and color

coded black and white. Each pair is printed numerically to ensure easy identification.4. ASSEMBLY: The individual pairs are cabled together to form round completed assembly.

Overall aluminum/polyester foil shield with stranded tinned copper drain wire. All cableassemblies include a communication wire for calibration.

5. OVERALL JACKET: Flame retardant, sunlight resistant, black PVC. A rip cord is included for jacket removal.

6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests.

7. TEMPERATURE: 105˚C8. VOLTAGE: 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Pairs IN 1000 Ft.

323-221-2001 20 1 .23 24323-221-2002 20 2 .38 58323-221-2003 20 3 .35 66323-221-2004 20 4 .42 87323-221-2006 20 6 .46 114323-221-2008 20 8 .50 139323-221-2010 20 10 .57 165323-221-2012 20 12 .59 190323-221-2016 20 16 .67 250323-221-2020 20 20 .71 308323-221-2024 20 24 .80 351323-221-2036 20 36 .83 480323-221-2050 20 50 1.10 660323-221-1801 18 1 .26 45323-221-1802 18 2 .44 83323-221-1803 18 3 .45 100323-221-1804 18 4 .48 125323-221-1806 18 6 .53 149

NOTE: Other pair counts available upon request.Diameters and weights may vary between manufacturers.

13-3©Anixter Inc. 1999 1-800-ANIXTER

9004S13A.QXD 6/9/99 2:24 PM Page 3

Page 4: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

OVERALL SHIELDEDSINGLE AND MULTI PAIR

Continued

PVC InsulationPVC Jacket105˚C, 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Pairs IN 1000 Ft.

323-221-1808 18 8 .57 200323-221-1810 18 10 .62 239323-221-1812 18 12 .66 295

323-221-1816 18 16 .76 370323-221-1820 18 20 .82 450323-221-1824 18 24 .89 530

323-221-1836 18 36 1.02 780323-221-1850 18 50 1.29 1230323-221-1601 16 1 .26 42

323-221-1602 16 2 .46 103323-221-1603 16 3 .48 130323-221-1604 16 4 .51 160

323-221-1606 16 6 .59 203323-221-1608 16 8 .67 280323-221-1610 16 10 .72 322

323-221-1612 16 12 .77 400323-221-1616 16 16 .86 510323-221-1620 16 20 .95 640

323-221-1624 16 24 1.05 750323-221-1636 16 36 1.23 1110323-221-1650 16 50 1.60 1352

NOTE: Other pair counts available upon request.Diameters and weights may vary between manufacturers.

13-4 ©Anixter Inc. 19991-800-ANIXTER

9004S13A.QXD 6/9/99 2:24 PM Page 4

Page 5: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

INDIVIDUALLY SHIELDEDMULTI PAIR

PVC InsulationPVC Jacket105˚C, 300 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduits, wireways and for aerial use when supported by a messenger. Suitable forClass 2 and 3 electrical circuits per NEC Article 725.

SPECIFICATIONS:1. CONDUCTORS: Stranded, tinned copper.2. INSULATION: 105˚C polyvinyl chloride (PVC).3. COLOR CODE: Pairs color coded black, red and numbered.4. ASSEMBLY: Twisted pairs each with an overall aluminum mylar shield and stranded

tinned copper drain wire.5. OVERALL JACKET: Sunlight resistant chrome polyvinyl chloride (PVC) jacket. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13.

Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests.7. TEMPERATURE: 105˚C8. VOLTAGE: 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Pairs IN 1000 Ft.

323-035-2202-B 22 2 0.32 48323-035-2203-B 22 3 0.33 60323-035-2204-B 22 4 0.36 73

323-035-2206-B 22 6 0.44 114323-035-2209-B 22 9 0.50 150323-035-2211-B 22 11 0.55 174

323-035-2219-B 22 19 0.69 288323-035-2251-B 22 51 1.05 745323-036-1802-B 18 2 0.38 70

323-036-1803-B 18 3 0.42 100323-036-1804-B 18 4 0.49 124323-036-1806-B 18 6 0.55 177

323-036-1809-B 18 9 0.67 262323-036-1811-B 18 11 0.69 307323-036-1815-B 18 15 0.77 393

NOTE: Other pair counts available upon request.

13-5©Anixter Inc. 1999 1-800-ANIXTER

9004S13A.QXD 6/9/99 2:24 PM Page 5

Page 6: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

BELDENOVERALL SHIELDED

MULTI PAIRPVC InsulationPVC Jacket105˚C, 300 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725.

SPECIFICATIONS:1. CONDUCTORS: Stranded, tinned copper.2. INSULATION: 105˚C polyvinyl chloride (PVC).3. COLOR CODE: Pairs color coded black, red and numbered.4. ASSEMBLY: Pairs are cabled with an overall aluminum/polyester shield and stranded tinned

copper drain wire.5. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC).6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13.

Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests.7. TEMPERATURE: 105˚C8. VOLTAGE: 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Pairs IN 1000 Ft.

323-023-2202-B 22 2 0.31 43323-023-2203-B 22 3 0.33 56323-023-2204-B 22 4 0.35 64

323-023-2206-B 22 6 0.43 93323-023-2209-B 22 9 0.49 123323-023-2211-B 22 11 0.54 145

323-023-2215-B 22 15 0.59 179323-023-2219-B 22 19 0.63 223323-023-2227-B 22 27 0.74 344

323-023-2251-B 22 51 0.95 595323-035-1802-B 18 2 0.36 66323-035-1803-B 18 3 0.40 90

323-035-1804-B 18 4 0.45 110323-035-1806-B 18 6 0.48 145323-035-1809-B 18 9 0.56 202

323-035-1811-B 18 11 0.68 254323-035-1815-B 18 15 0.75 322

NOTE: Other pair counts available upon request.

13-6 ©Anixter Inc. 19991-800-ANIXTER

9004S13A.QXD 6/9/99 2:24 PM Page 6

Page 7: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

INDIVIDUAL AND OVERALL SHIELDEDMULTI PAIR

PVC InsulationPVC Jacket105˚C, 300 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications. Individually and overall shielded for greater isolation and noise reduction. Suitable for installation in trays, troughs, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725.

SPECIFICATIONS:1. CONDUCTORS: Bare copper, Class B, concentric stranded.2. INSULATION: 105˚C polyvinyl chloride (PVC).3. PAIRS: Each pair is twisted with a suitable lay to reduce magnetic interference and

color coded black and white. Each pair is also printed numerically to ensure easy identification. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied.

4. ASSEMBLY: The individual pairs are cabled together to form a substantially circular cross-section of the completed assembly. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied overall. All cable assemblies include a communication wire for calibration and a rip cord for jacket removal.

5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC) jacket.6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13.

Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests.7. TEMPERATURE: 105˚C8. VOLTAGE: 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Pairs IN 1000 Ft.

323-231-2002 20 2 .42 61323-231-2003 20 3 .43 72323-231-2004 20 4 .44 105

323-231-2006 20 6 .53 145323-231-2008 20 8 .56 170323-231-2012 20 12 .69 248

323-231-2016 20 16 .77 315323-231-2024 20 24 .95 475323-231-2036 20 36 1.06 660

323-231-2050 20 50 1.28 880323-231-1802 18 2 .46 91323-231-1803 18 3 .47 122

NOTE: Other pair counts available upon request.Diameters and weights may vary between manufacturers.

13-7©Anixter Inc. 1999 1-800-ANIXTER

9004S13A.QXD 6/9/99 2:25 PM Page 7

Page 8: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

INDIVIDUAL AND OVERALL SHIELDEDMULTI PAIR

Continued

PVC InsulationPVC Jacket105˚C, 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Pairs IN 1000 Ft.

323-231-1804 18 4 .51 148323-231-1806 18 6 .60 210323-231-1808 18 8 .69 270

323-231-1812 18 12 .84 380323-231-1816 18 16 .94 490323-231-1824 18 24 1.13 700

323-231-1836 18 36 1.26 1010323-231-1850 18 50 1.51 1350323-231-1602 16 2 .48 131

323-231-1603 16 3 .49 135323-231-1604 16 4 .55 195323-231-1606 16 6 .59 276

323-231-1608 16 8 .76 350323-231-1612 16 12 .91 520323-231-1616 16 16 1.05 660

323-231-1624 16 24 1.22 970323-231-1636 16 36 1.41 1440323-231-1650 16 50 1.65 1668

NOTE: Other pair counts available upon request.Diameters and weights may vary between manufacturers.

13-8 ©Anixter Inc. 19991-800-ANIXTER

9004S13A.QXD 6/9/99 2:25 PM Page 8

Page 9: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

OVERALL SHIELDEDSINGLE AND MULTI TRIAD

PVC InsulationPVC Jacket105˚C, 300 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725.

SPECIFICATIONS:1. CONDUCTORS: Bare copper, Class B, concentric stranded.2. INSULATION: 105˚C polyvinyl chloride (PVC).3. TRIADS: Each triad is twisted with a suitable lay to reduce magnetic interference and color

coded black, white and red. Each triad is also printed numerically to ensure easy identification.4. ASSEMBLY: The individual triads are cabled together to form a substantially circular

cross-section of the completed assembly. Overall aluminum/polyester foil shield with stranded tinned copper drain wire. All cables include a communication wire for calibration and a rip cord for jacket removal.

5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC).6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13.

Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests.6. TEMPERATURE: 105˚C7. VOLTAGE: 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Triads IN 1000 Ft.

323-321-2001 20 1 .30 30323-321-2004 20 4 .44 119323-321-2012 20 12 .69 282323-321-2016 20 16 .76 356323-321-2024 20 24 .93 560323-321-2036 20 36 1.19 745323-321-1801 18 1 .32 45323-321-1804 18 4 .53 170323-321-1812 18 12 .86 430323-321-1816 18 16 .99 580323-321-1824 18 24 1.20 700323-321-1836 18 36 1.45 1368323-321-1601 16 1 .35 53323-321-1604 16 4 .57 210323-321-1612 16 12 .97 600323-321-1616 16 16 1.14 750323-321-1636 16 36 1.52 1590

NOTE: Other triad counts available upon request.Diameters and weights may vary between manufacturers.

13-9©Anixter Inc. 1999 1-800-ANIXTER

9004S13A.QXD 6/9/99 2:25 PM Page 9

Page 10: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC 300 VOLT

INDIVIDUAL AND OVERALL SHIELDEDMULTI TRIAD

PVC InsulationPVC Jacket105˚C, 300 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725.

SPECIFICATIONS:1. CONDUCTORS: Bare copper, Class B, concentric stranded.2. INSULATION: 105˚C polyvinyl chloride (PVC).3. TRIADS: Each triad is twisted with a suitable lay to reduce magnetic interference and color

coded black. Each triad is also printed numerically to ensure easy identification. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied.

4. ASSEMBLY: The individual triads are cabled together to form a substantially circular cross-section of the completed assembly. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied overall. All cable assemblies include a communication wire for calibration and a rip cord for jacket removal.

5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC) jacket.6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13.

Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests.7. TEMPERATURE: 105˚C8. VOLTAGE: 300 Volts

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Triads IN 1000 Ft.

323-331-2004 20 4 .50 128323-331-2008 20 8 .57 220323-331-2012 20 12 .78 323323-331-2016 20 16 .87 411323-331-2024 20 24 .97 675323-331-2036 20 36 1.27 900323-331-1804 18 4 .54 182323-331-1808 18 8 .67 410323-331-1812 18 12 1.04 590323-331-1816 18 16 1.16 780323-331-1824 18 24 1.26 850323-331-1836 18 36 1.58 1850323-331-1604 16 4 .61 240323-331-1612 16 12 1.04 690323-331-1616 16 16 1.16 890323-331-1636 16 36 1.58 1850

NOTE: Other triad counts available upon request.Diameters and weights may vary between manufacturers.

13-10 ©Anixter Inc. 19991-800-ANIXTER

9004S13A.QXD 6/9/99 2:25 PM Page 10

Page 11: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC

BELDENDATABUS FIELDBUS

ISA/IEC SP-50Twisted PairOrange Jacket300 Volts

APPLICATIONS:Bi-directional, digital signal cable used to replace traditional high pair count 4-20ma industrial PLTC cable for “fieldbus” devices.

SPECIFICATIONS:1. CONDUCTORS: Tinned, stranded copper.2. INSULATION: Type A & B — Polyethylene (PE). High speed — Cellular polyethylene.3. SHIELD: 100% aluminum/polyester.4. OVERALL JACKET: Orange polyvinyl chloride (PVC).5. STANDARDS: Conforms to ISA/IEC SP-50 “fieldbus” physical layer specification. Meets NEC

Article 725 requirements for Type PLTC. Also meets UL and CSA Type CM requirements.

Cond. NominalBelden Size Number Imped. Capacitance O.D.

Anixter Part ofNumber Number Type AWG Stranding Pairs ohms Speed pf/Ft. IN

B3076F 3076F A 18 7 x 26 1 100 31.25 kb/s 25 .245B3077F 3077F B 22 7 x 30 1 100 31.25 kb/s 25 .201B3078F 3078F High Speed 22 7 x 30 1 150 1 or 2.5 Mb/s 9 .373

NOTE: European Profibus cable (Belden Part No. 3079F) available upon request.

13-11©Anixter Inc. 1999 1-800-ANIXTER

9004S13A.QXD 6/9/99 2:25 PM Page 11

Page 12: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

13-12 ©Anixter Inc. 19991-800-ANIXTER

PLTC

BELDENDATATRAY TWINAX

Polyolefin InsulationPVC JacketShielded600 Volts

APPLICATIONS:For use in most programmable logic control systems (PLCs) and distributed control systems (DCS) in industrial environments. May be installed in cable tray or conduit for a variety of data applications (RS-232, 422 & 485).

SPECIFICATIONS:1. CONDUCTOR: Annealed, tinned copper.2. INSULATION: Low attenuation, flame-retardant polyolefin.3. SHIELD: 100% coverage aluminum/polyester and 55% coverage tinned copper braid.4. OVERALL JACKET: Dark blue, sunlight resistant, polyvinyl chloride (PVC).5. STANDARDS: Meets the UL requirements for Type PLTC cable. Meets the UL 1581 vertical

tray 70,000 BTU flame test. Meets NEC Article 725 for Class 2 (CL2) circuits and Article 800for Communications general purpose (CM). Also meets CSA Type CM requirements.

Conductor NominalBelden Size Number Impedance Capacitance O.D. Approximate

Anixter Part of Weight Lbs.Number Number AWG Stranding Pairs ohms pf/Ft. IN 1000 Ft.

B3072F 3072F 18 7 x 26 1 78 19.7 .315 50B3073F 3073F 18 7 x 26 1 100 15.5 .370 64B3074F 3074F 18 7 x 26 1 124 12.5 .450 81

B3075F 3075F 18 7 x 26 1 150 10.3 .615 143

NOTE: Multi pairs/Multi conductors available. Wet location rating and Oil Res II jacket available. Any Datatray cable may be armored upon request.

9004S13A.QXD 6/9/99 2:25 PM Page 12

Page 13: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

PLTC

BELDENINDUSTRIAL AUTOMATION

Aluminum ArmorPVC Jacket300 Volts

APPLICATIONS:Used in industrial locations requiring extra mechanical protection and system reliability for high speed electronic signalling.

SPECIFICATIONS:1. CABLE CORE: Cable design configurations for the following PLC manufacturers:

Allen Bradley, Square D: Belden Pt. # 129463Allen Bradley: Belden Pt. # 129842, 128723IBM, Foxboro: Belden Pt. # 129207Modicon: Belden Pt. # 129114, 129841GE Fanuc, DEC: Belden Pt. # 129182DEC, Foxboro, Hewlett Packard: Belden Pt. # 129880IBM: Belden Pt. # 129269Honeywell: Belden Pt. # 129729

2. ARMOR: Aluminum interlocked.3. OVERALL JACKET: Polyvinyl chloride (PVC).4. STANDARDS: Meets UL 1581 70,000 BTU flame test. Meets CSA FT4 flame test

requirements. Low acid gas outer jacket per CSA.

ConductorNominal O.D.

Belden Size Inner Jacket Armor Outer Jacket ApproximateAnixter Part Weight Lbs. UL and CSANumber Number AWG IN IN IN 1000 Ft. Designation

317-010-2402-BA 129729 24 .317 .550 .650 154 CM318-011-2203-BA 128777 22 .273 .490 .590 143 CM318-198-2202-BA 128723 22 .240 .455 .560 117 CM

317-011-2401A-BA 129841 24 .232 .470 .560 135 CM317-011-2402A-BA 129842 24 .340 .560 .660 175 CM308-011-0622A-BA 129268 22 .260 .475 .580 136 CL2

308-011-0621-BA 129269 22 .240 .460 .560 131 CL2318-298-2201DS-BA 129182 22 .345 .565 .670 153 CL2310-035-9838-BA 129207 20 .330 .540 .640 173 CL2

309-011-7897A-BA 129463* 20 .243 .460 .560 133 CM308-011-0066-BA 129114 18 .270 .490 .590 137 CM308-011-0063-BA 129290 18 .290 .505 .610 161 CL2

307-011-011A-BA 128261 18 .405 .620 .730 224 CMG308-011-0114-BA 129292 14 .405 .620 .730 211 CMG308-075-0501-BA 129880 12 .405 .620 .730 248 CL2

309-047-1244-BA 129860 16 .440 .655 .765 241 CL2

* This product is frequently referred to as Allen Bradley armored “Blue Hose.”Remove 12 from Belden part number to get core part number (e.g., 129463 is armored Belden 9463).NOTE: Galvanized steel interlocked armor available upon request.

13-13©Anixter Inc. 1999 1-800-ANIXTER

9004S13A.QXD 6/9/99 2:25 PM Page 13

Page 14: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

TC 600 VOLT

PVC-NYLON/PVCUNSHIELDED AND SHIELDED

MULTI CONDUCTORPVC-Nylon InsulationPVC Jacket90˚C, 600 Volts

APPLICATIONS:For use as instrumentation cable inside or outside in control applications and suitable for direct burial. ULListed for installation in trays, troughs, channels, conduit and wireways in accordance with Articles 318, 340 and 501 of the NEC.

SPECIFICATIONS:1. CONDUCTORS: Stranded, tinned copper.2. INSULATION: 90˚C polyvinyl chloride (PVC), nylon overcoat.3. COLOR CODE: Conductors are color coded black, red.4. ASSEMBLY: Shielded cables are cabled with an overall aluminum/polyester shield and

stranded, tinned copper drain wire.5. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC) jacket, suitable for outdoor

use and direct burial.6. STANDARDS: Meets requirements of UL 1277 and passes the UL 1581 vertical tray flame test.7. TEMPERATURE: 90˚C8. VOLTAGE: 600 Volts

Unshielded

Conductor Size Number Nominal O.D. ApproximateAnixter of Weight Lbs.Number AWG Conductors IN 1000 Ft.

B9486 18 2 0.28 44B9487 16 2 0.31 54B9488 14 2 0.36 76

B9489 12 2 0.38 96

ShieldedB9341 18 2 0.28 47B9342 16 2 0.30 60B9343 14 2 0.36 88

B9344 12 2 0.38 115

13-14 ©Anixter Inc. 19991-800-ANIXTER

9004S13B.QXD 6/9/99 2:23 PM Page 14

Page 15: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

13-15©Anixter Inc. 1999 1-800-ANIXTER

TC 600 VOLT

PVC-NYLON/PVCSHIELDED

MULTI PAIRPVC-Nylon InsulationPVC Jacket90˚C, 600 Volts

APPLICATIONS:For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication.

SPECIFICATIONS:1. CONDUCTORS: Bare copper, Class B stranded per ASTM B-8.2. INSULATION: Polyvinyl chloride (PVC) and nylon. Pairs are color coded black and white

and numbered. Triads are black, white, red and numbered.3. SHIELDING: Shields are Aluminum/polyester. Overall drain wire is seven-strand tinned

copper. Where applicable, individual drain wires are used, also of seven-strand, tinned copper construction.

4. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC).5. STANDARDS: Meets the requirements of UL 1277 and passes the UL 1581 vertical tray

flame test.6. TEMPERATURE: 90˚C7. VOLTAGE: 600 Volts

Conductor Overall Jacket NominalSize

NumberThickness O.D.

ApproximateAnixter* of Weight Lbs.Number AWG Pairs Triads IN IN 1000 Ft.

2AS-1801POS 18 1 .045 .280 412AS-1801TOS 18 1 .045 .445 802AS-1802POS 18 2 .045 .440 722AS-1803POS 18 3 .045 .465 902AS-1804POS 18 4 .045 .505 1102AS-1806POS 18 6 .060 .598 1672AS-1808POS 18 8 .060 .652 2042AS-1812POS 18 12 .060 .770 2772AS-1816POS 18 16 .080 .905 3872AS-1824POS 18 24 .080 1.055 5322AS-1836POS 18 36 .080 1.190 7392AS-1802SPOS 18 2 .045 .445 842AS-1803SPOS 18 3 .045 .480 1062AS-1804SPOS 18 4 .045 .555 1452AS-1806SPOS 18 6 .060 .639 2032AS-1808SPOS 18 8 .060 .700 2502AS-1812SPOS 18 12 .060 .845 3502AS-1816SPOS 18 16 .080 .960 4752AS-1824SPOS 18 24 .080 1.130 6702AS-1836SPOS 18 36 .080 1.345 957

*POS–Pair(s) Overall Shield. SPOS–Shielded Pairs with Overall Shield.TOS–Triad(s) Overall Shield. NOTE: Diameters and weights may vary between manufacturers.

9004S13B.QXD 6/9/99 2:23 PM Page 15

Page 16: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

TC 600 VOLT

PVC-NYLON/PVCSHIELDED

MULTI PAIRContinued

PVC-Nylon InsulationPVC Jacket90˚C, 600 Volts

Conductor Overall Jacket NominalSize

NumberThickness O.D.

ApproximateAnixter* of Weight Lbs.Number AWG Pairs Triads IN IN 1000 Ft.

2AS-1601POS 16 1 .045 .300 522AS-1601TOS 16 1 .045 .315 632AS-1602POS 16 2 .045 .470 93

2AS-1603POS 16 3 .045 .505 1172AS-1604POS 16 4 .060 .575 1602AS-1606POS 16 6 .060 .660 282

2AS-1608POS 16 8 .060 .745 3302AS-1612POS 16 12 .080 .825 3702AS-1616POS 16 16 .020 .970 513

2AS-1624POS 16 24 .080 1.320 7402AS-1636POS 16 36 .080 1.285 10402AS-1602SPOS 16 2 .045 .495 105

2AS-1603SPOS 16 3 .045 .520 1372AS-1604SPOS 16 4 .060 .600 1882AS-1606SPOS 16 6 .060 .685 270

2AS-1608SPOS 16 8 .060 .745 3372AS-1612SPOS 16 12 .080 .940 4982AS-1616SPOS 16 16 .080 1.055 635

2AS-1624SPOS 16 24 .080 1.260 9032AS-1636SPOS 16 36 .080 1.480 12902AS-1401POS 14 1 .045 .360 65

2AS-1401TOS 14 1 .045 .360 94

*POS–Pair(s) Overall Shield. SPOS–Shielded Pairs with Overall Shield.TOS–Triad(s) Overall Shield. NOTE: Diameters and weights may vary between manufacturers.

13-16 ©Anixter Inc. 19991-800-ANIXTER

9004S13B.QXD 6/9/99 2:23 PM Page 16

Page 17: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

13-17©Anixter Inc. 1999 1-800-ANIXTER

TC 600 VOLT

XLP/HYPALONSHIELDED

MULTI PAIRXLP InsulationHypalon Jacket90˚C, 600 Volt

APPLICATIONS:For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication.

SPECIFICATIONS:1. CONDUCTORS: Annealed, tinned copper in accordance with ASTM B-3 and B-33.

Concentric stranded, Class B per ASTM B-8.2. INSULATION: Cross-linked polyethylene (XLP), per ICEA S-66-524 (NEMA WC7). UL rated

VW-1 conductors.3. PAIRS/TRIADS: Each pair/triad is twisted to a 2 in. lay. Color coded: pairs black/white,

triads black/white/red with alphanumeric designation (1-ONE).4. ASSEMBLY: The individually shielded pairs are cabled together with non-hygroscopic

and flame retardant fillers as necessary to form a circular cross section of the assembly. A binding tape, when required, shall be applied over cable core.

5. SHIELDING: The entire cable assembly is shielded with polyester backed/aluminum tapeand tinned copper drain wire.

6. OVERALL JACKET: Flame retardant Hypalon (CSPE).7. STANDARDS: Meets the requirements of UL 1277. Finished cable passes UL 1581

70,000 BTU and ICEA T-29-520 210,000 BTU flame tests. UL listed as sunlight resistant andrated for direct burial.

8. TEMPERATURE: 90˚C9. VOLTAGE: 600 Volts

Conductor Number Insulation Overall Jacket NominalSize of Thickness Thickness O.D. Approximate

Anixter* Weight Lbs.Number AWG Pairs Triads IN IN IN 1000 Ft.

2RH-1601POS 16 1 .030 .045 .340 662RH-1601TOS 16 1 .030 .045 .365 822RH-1602POS 16 2 .030 .045 .595 1162RH-1603POS 16 3 .030 .060 .640 1852RH-1604POS 16 4 .030 .060 .690 2292RH-1606POS 16 6 .030 .060 .735 3202RH-1608POS 16 8 .030 .080 .920 4432RH-1612POS 16 12 .030 .080 1.085 6112RH-1624POS 16 24 .030 .080 1.475 11302RH-1636POS 16 36 .030 .080 1.600 17282RH-1602SPOS 16 2 .030 .060 .595 1162RH-1603SPOS 16 3 .030 .060 .640 185

*POS–Pair(s) Overall Shield. SPOS–Shielded Pairs with Overall Shield.TOS–Triad(s) Overall Shield. NOTE: Diameters and weights may vary between manufacturers.

9004S13B.QXD 6/9/99 2:23 PM Page 17

Page 18: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

TC 600 VOLT

XLP/HYPALONSHIELDED

MULTI PAIRContinued

XLP InsulationHypalon Jacket90˚C, 600 Volt

Conductor Number Insulation Overall Jacket NominalSize of Thickness Thickness O.D. Approximate

Anixter* Weight Lbs.Number AWG Pairs Triads IN IN IN 1000 Ft.

2RH-1604SPOS 16 4 .030 .060 .690 2292RH-1606SPOS 16 6 .030 .060 .735 3202RH-1608SPOS 19 8 .030 .080 .920 443

2RH-1612SPOS 16 12 .030 .080 1.085 6112RH-1624SPOS 16 24 .030 .080 1.475 11302RH-1636SPOS 16 36 .030 .110 1.600 1728

2RH-1401POS 14 1 .030 .045 .375 752RH-1401TOS 14 1 .030 .045 .375 105

*POS–Pair(s) Overall Shield. SPOS–Shielded Pairs with Overall Shield.TOS–Triad(s) Overall Shield. NOTE: Diameters and weights may vary between manufacturers.

13-18 ©Anixter Inc. 19991-800-ANIXTER

9004S13B.QXD 6/9/99 2:23 PM Page 18

Page 19: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

13-19©Anixter Inc. 1999 1-800-ANIXTER

TC 600 VOLT

EPR/CPESHIELDED

MULTI PAIREPR InsulationCPE Jacket90˚C, 600 Volt

APPLICATIONS:For use indoors or outdoors and for installationin trays, troughs, channels, ducts and direct

burial. Designed for telemetering, signals, relaysand communication.

SPECIFICATIONS:1. CONDUCTORS: Annealed, tinned copper in accordance with ASTM B-3 and B-33.

Concentric stranded, Class B per ASTM B-8.2. INSULATION: Ethylene propylene rubber (EPR), per ICEA S-68-516. UL rated VW-1 conductors.3. PAIRS/TRIADS: Each pair/triad is twisted to a 2 in. lay. Color coded: pairs black/white,

triads black/white/red with alphanumeric designation (1-ONE).4. ASSEMBLY: The individually shielded pairs are cabled together with non-hygroscopic

and flame retardant fillers as necessary to form a circular cross section of the assembly. A binding tape, when required, shall be applied over cable core.

5. SHIELDING: The entire cable assembly is shielded with polyester backed/aluminum tapeand tinned copper drain wire.

6. OVERALL JACKET: Flame retardant chlorinated polyethylene (CPE).7. STANDARDS: Meets the requirements of UL 1277. Finished cable passes UL 1581

70,000 BTU and ICEA T-29-520, 210,000 BTU flame tests. UL listed as sunlight resistantand rated for direct burial.

8. TEMPERATURE: 90˚C9. VOLTAGE: 600 Volts

Conductor Number Insulation Overall Jacket NominalSize of Thickness Thickness O.D. Approximate

Anixter* Weight Lbs.Number AWG Pairs Triads IN IN IN 1000 Ft.

2MR-1601POS 16 1 .025 .045 .318 592MR-1601TOS 16 1 .025 .045 .336 752MR-1602POS 16 2 .025 .045 .365 922MR-1603POS 16 3 .025 .060 .587 1812MR-1604POS 16 4 .025 .060 .627 2202MR-1606POS 16 6 .025 .060 .680 2502MR-1608POS 16 8 .025 .080 .850 4002MR-1612POS 16 12 .025 .080 1.022 5622MR-1624POS 16 24 .025 .080 1.351 10422MR-1636POS 16 36 .025 .080 1.395 11282MR-1602SPOS 16 2 .025 .060 .583 1662MR-1603SPOS 16 3 .025 .060 .591 1892MR-1604SPOS 16 4 .025 .060 .638 2312MR-1606SPOS 16 6 .025 .080 .775 2952MR-1608SPOS 16 8 .025 .080 .865 4162MR-1612SPOS 16 12 .025 .080 1.047 5812MR-1624SPOS 16 24 .025 .080 1.393 10672MR-1636SPOS 16 36 .025 .110 1.735 1419

*POS–Pair(s) Overall Shield. SPOS–Shielded Pairs with Overall Shield.TOS–Triad(s) Overall Shield. NOTE: Diameters and weights may vary between manufacturers.

9004S13B.QXD 6/9/99 2:23 PM Page 19

Page 20: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

FIBER OPTIC CABLE

PVC/PVC TRAY CABLE62.5µm/125µmLoose Tube BufferPVC Jacket

APPLICATIONS:Suitable for outdoor duct, indoor general purpose and aerial use. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray.

SPECIFICATIONS:1. FIBER SIZE: 62.5µm/125µm 2. CONSTRUCTION: Loose buffer with gel filling and sunlight resistant polyvinyl chloride

(PVC) jacket overall.3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as OFN

per NEC Article 770.

Max. Min.Attenuation Bandwidth Max. Tensile Load Min. Bend Radius

@850/ @850/ Nom.No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Approx.

Anixter of Wt. Lbs.Number Fibers dB/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft.

370-062-IEEE-02 2 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95370-062-IEEE-04 4 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95370-062-IEEE-06 6 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95

370-062-IEEE-08 8 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95370-062-IEEE-12 12 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95370-062-IEEE-18 18 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95

370-062-IEEE-24 24 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95

13-20 ©Anixter Inc. 19991-800-ANIXTER

9004S13B.QXD 6/9/99 2:23 PM Page 20

Page 21: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

FIBER OPTIC CABLE

BELDEN TRAYOPTICSPVC

62.5µm/125µmLoose Tube Buffer

APPLICATIONS:Suitable for indoor or outdoor industrial installations. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray.

SPECIFICATIONS:1. FIBER SIZE: 62.5µm/125µm2. CONSTRUCTION: Loose buffer with gel filling, central strength member, inner polyvinyl

chloride (PVC) jacket, aramid yarn and orange polyvinyl chloride (PVC) jacket overall.3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as

OFNR (2–12 fiber) or OFN (18–24 fiber) per NEC Article 770. Crush resistance: 500 lbs./inch minimum.

Max. Min.Attenuation Bandwidth Max. Tensile Load Min. Bend Radius

@850/ @850/ Nom. Approx.Belden No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Wt.

Anixter Part of Lbs.Number No. Fibers dB/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft.

BI100255 I100255 2 3.5/1.0 160/500 600 180 8.68 4.34 .434 70BI100455 I100455 4 3.5/1.0 160/500 600 180 8.68 4.34 .434 70BI100655 I100655 6 3.5/1.0 160/500 600 180 8.68 4.34 .434 70

BI400855 I400855 8 3.5/1.0 160/500 600 180 11.18 5.59 .559 95BI601255 I601255 12 3.5/1.0 160/500 600 180 11.18 5.59 .559 95BI601855 I601855 18 3.5/1.0 160/500 600 180 11.18 5.59 .559 95

BI602455 I602455 24 3.5/1.0 160/500 600 180 11.18 5.59 .559 95

NOTE: Cable with up to 72 fibers available upon request.

13-21©Anixter Inc. 1999 1-800-ANIXTER

9004S13B.QXD 6/9/99 2:23 PM Page 21

Page 22: UNSHIELDED MULTI CONDUCTOR - Anixter€¦ ·  · 2009-04-23UNSHIELDED MULTI CONDUCTOR PVC Insulation PVC Jacket 105˚C, ... 323-221-2001 20 1 .23 24 323-221-2002 20 2 .38 58 ...

FIBER OPTIC CABLE

BELDEN TRAYOPTICSCPE

62.5µm/125µmLoose Tube Buffer

APPLICATIONS:Suitable for indoor or outdoor industrial installations. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray.

SPECIFICATIONS:1. FIBER SIZE: 62.5µm/125µm2. CONSTRUCTION: Loose buffer with gel filling, central strength member, inner CPE

jacket, aramid yarn and orange CPE jacket overall.3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as

OFNR (2–12 fiber) or OFN (18–24 fiber) per NEC Article 770. Crush resistance:500 lbs./inch minimum

Max. Min.Attenuation Bandwidth Max. Tensile Load Min. Bend Radius

@850/ @850/ Nom. Approx.Belden No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Wt.

Anixter Part of Lbs.Number No. Fibers dB/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft.

BI100266 I100266 2 3.5/1.0 160/500 600 180 8.68 4.34 .434 70BI100466 I100466 4 3.5/1.0 160/500 600 180 8.68 4.34 .434 70BI100666 I100666 6 3.5/1.0 160/500 600 180 8.68 4.34 .434 70

BI400866 I400866 8 3.5/1.0 160/500 600 180 11.18 5.59 .559 95BI601266 I601266 12 3.5/1.0 160/500 600 180 11.18 5.59 .559 95BI601866 I601866 18 3.5/1.0 160/500 600 180 11.18 5.59 .559 95

BI602466 I602466 24 3.5/1.0 160/500 600 180 11.18 5.59 .559 95

NOTE: Cable with up to 72 fibers available upon request.

13-22 ©Anixter Inc. 19991-800-ANIXTER

9004S13B.QXD 6/9/99 2:23 PM Page 22