UC5 Ordering Guide - SK Staycation · 1 1 Introduction This UC5 Cable Ordering Guide illustrates...
Transcript of UC5 Ordering Guide - SK Staycation · 1 1 Introduction This UC5 Cable Ordering Guide illustrates...
Printed in Canada
Copyright 2014 by NORAC Systems International Inc. Reorder P/N: UC5‐BC‐CABLE‐GUIDE Rev I (UC5 Cable Ordering Guide)
NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.
Contents
1 Introduction .................................................................................................................... 1
2 General UC5 System Layout ............................................................................................. 2
3 Typical UC5 Height Control System .................................................................................. 4
4 Choosing the Correct Cables ............................................................................................ 5
5 Power Cables (Item C30) .................................................................................................. 6
6 Interface Cables: Tilt (Item C20) ..................................................................................... 14
7 Interface Cables: Main Lift & Aux (Item C21) ................................................................. 27
8 Valve Cables (Item C10) ................................................................................................. 45
9 Network Cables ............................................................................................................. 52
10 Network Couplers, Plugs & Terminators ........................................................................ 54
11 Interface Cables: CANbus ............................................................................................... 58
12 Interface Cables: Switchbox ........................................................................................... 75
13 Bus Monitor Cables ....................................................................................................... 77
14 Interface Cables: Specialty ............................................................................................. 82
1
1 Introduction
This UC5 Cable Ordering Guide illustrates the available cables for the UC5 system. Please take the time to read this list to determine necessary cables for your UC5 Height Control System.
Your input can help make us better! If you find issues or have suggestions please don’t hesitate to contact us.
Phone: 1 800 667 3921 Canada (Toll Free)
1 866 306 6722 United States (Toll Free)
(+33) (0)4 26 47 04 42 Europe
(+1) 306 664 6711 All other regions
E‐mail: [email protected]
Web: www.norac.ca
Every effort has been made to ensure the accuracy of the information contacted in this document. All parts supplied are selected to specially fit the sprayer to facilitate a complete installation. However, NORAC cannot guarantee all parts fit as intended due to the variations of the sprayer by the manufacturer.
2
2 General UC5 System Layout
Figure 1, Figure 2 and Figure 3 illustrate the general layout of the UC5 system components:
Figure 1: General UC5 System Layout (Self Propel Type)
Figure 2: General UC5 System Layout (Pull Type)
4
3 Typical UC5 Height Control System
Figure 4 depicts a typical UC5 Height Control System. The various cables are listed in this ordering guide. To choose the most suitable cables, refer to the UC5 installation manual, the sprayer’s valve connections and the electrical wiring system.
Figure 4: Typical UC5 System
5
4 Choosing the Correct Cables
The following table shows the cables that are required for the main connections in the UC5 system. Refer to Figure 4 for the location of each cable by item number.
ItemPart
NumberDescription
Available Lengths
Typical Length
Quantity Needed
C01 43220-XXControl Module to Valve Module: UC5 Network Cable 14 AWG
0.5,1,3,5,7,10, 15,20 m
10 m 1
C02 43220-XXValve Module to Input Module: UC5 Network Cable 14 AWG
0.5,1,3,5,7,10, 15,20 m
1 m 1
C03 43220-XXInput Module to 8-way Coupler: UC5 Network Cable 14 AWG
0.5,1,3,5,7,10, 15,20 m
1 m 1
C04 43220-XXMain Lift Sensor to 8-way Coupler: UC5 Network Cable 14 AWG (This cable is not always required)
0.5,1,3,5,7,10, 15,20 m
3 m 1
C05 43210-XXWing Sensor to 8-way Coupler: UC5 Network Cable 18 AWG
10,15,20 m 20 m 2
C10 Various UC5 Valve Cable 0.18,0.9,1.8 m 0.18 m 4
C20 Various UC5 Tilt Interface Cable Various 1.5 m 1
C21 Various UC5 Main Lift, Bypass & Slant Interface Cable Various 1.5 m 1
C30 Various UC5 Battery Cable Various 1.5 m 1
6
5 Power Cables (Item C30)
All power cables are 60” (1.5m) in length unless otherwise noted.
5.1 43250‐04 (Rev C) – CABLE UC5 BATTERY AMP FUSED
5.2 43250‐06 (Rev C) – CABLE UC5 BATTERY PIGTAIL FUSED
7
5.3 43250‐07 (Rev C) – CABLE UC5 BATTERY JD FUSED
5.4 43250‐08 (Rev C) – CABLE UC5 BATTERY AMP TEE FUSED
9
5.6 43250‐10 (Rev A) ‐ UC5 NETWORK POWER JUMPER
5.7 43250‐11 (Rev D) ‐ CABLE UC5 BATTERY PIGTAIL (30” [0.75m])
10
5.8 43250‐12 (Rev C) ‐ CABLE UC5 BATTERY PIGTAIL FUSED (ECU & SIG)
5.9 43250‐13 (Rev C) ‐ CABLE UC5 BATTERY AMP FUSED (ECU & SIG)
11
5.10 43250‐14 (Rev D) ‐ CABLE UC5 BATTERY 2 PIN DT TEE FUSED (ECU & SIG)
5.11 43250‐16 (Rev C) ‐ CABLE UC5 BATTERY 6‐PIN DT FUSED (ECU & SIG) (52” [1.3m])
12
5.12 43250‐17 (Rev E) ‐ CABLE UC5 POWER RETROFIT FOR ECHO SWITCH FUSED
Connects an ECHO with a power switch to control modules with serial numbers 3000 and lower.
13
5.13 43250‐18 (Rev A) ‐ CABLE UC5 BATTERY FUSED (ECU & SIG)
5.14 43250‐19 (Rev A) ‐ CABLE UC5 BATTERY 4‐PIN DT FUSED (ECU & SIG) (20” [0.5m])
14
6 Interface Cables: Tilt (Item C20)
All tilt interface cables are 60” (1.5 m) in length unless otherwise noted.
Used to interface with sprayer hydraulic and wing valves.
6.1 43240‐01 (Rev C) – CABLE UC5 INTERFACE TILT DT
27
7 Interface Cables: Main Lift & Aux (Item C21)
All main lift interface cables are 60” (1.5 m) in length unless otherwise noted.
Used to interface with sprayer main lift, directional and bypass valves.
7.1 43240‐04 (Rev C) – CABLE UC5 INTERFACE MAIN MP (METRIPACK 150)
45
8 Valve Cables (Item C10)
Connects the NORAC valve module to the NORAC valve block.
8.1 43230‐01 (Rev A) – CABLE UC5 VALVE 2 PIN DT TO BLACK DIN (8” [0.2m])
8.2 43230‐04 (Rev A) – CABLE UC5 VALVE 2 PIN DT TO 2 PIN DT (8” [0.2m])
46
8.3 43230‐06 (Rev A) – CABLE UC5 VALVE 2 PIN DT TO 2 PIN DT (36” [0.9m] LENGTH)
8.4 43230‐07 (Rev C) – CABLE UC5 VALVE 2 PIN DT TO 2 PIN DT (84” [2.1m] LENGTH)
52
9 Network Cables
9.1 43210‐XX (Rev A) ‐ CABLE UC5 NETWORK 18 AWG
The “XX” in the part number denotes the cable length. Replace it with the cable length required. Cables are available in: 10, 15 and 20 meter lengths (395”, 595” and 780”).
53
9.2 43220‐XX (Rev A) ‐ CABLE UC5 NETWORK 14 AWG
The “XX” in the part number denotes the cable length. Replace it with the cable length required. Cables are available in: 0.5, 1, 3, 5, 7, 10, 15 and 20 meter lengths (20”, 40”, 120”, 200”, 275”, 395”, 595” and 780”).
54
10 Network Couplers, Plugs & Terminators
10.1 43760 (Rev C) – UC5 NETWORK COUPLER 3‐WAY (ITEM E10)
56
10.3 43764 (Rev B) – UC5 NETWORK COUPLER 2‐WAY (ITEM E12)
10.4 43764T (Rev B) – UC5 NETWORK COUPLER 2‐WAY WITH TERMINATOR (ITEM E20)
57
10.5 106034 – UC5 NETWORK 2 PIN PLUG (ITEM P01)
10.6 106602 – UC5 NETWORK 12 PIN PLUG (A‐KEY) (ITEM P02)
10.7 105882 – UC5 NETWORK 6 PIN PLUG (ITEM P03)
58
11 Interface Cables: CANbus
Used to interface with the existing sprayer CANbus.
11.1 43240‐28 (Rev D) – CABLE UC5 INTERFACE CAN BUS (PIGTAIL) (30” [0.75m])
75
12 Interface Cables: Switchbox
12.1 43240‐26 (Rev C) – CABLE UC5 INTERFACE SWITCH BOX (480” [12.2m])
78
13.2 44644‐08 (Rev A) ‐ CABLE BUS MONITOR (DT FEMALE TO AMP MALE) (10” [0.25m])
13.3 44644‐10 (Rev A) ‐ CABLE BUS MONITOR UC5 SENSOR ADAPTER (10” [0.25m])
80
13.5 44644‐12 (Rev A) ‐ CABLE BUS MONITOR (DT MALE TO AMP FEMALE) (10” [0.25m])
13.6 44644‐14 (Rev A) ‐ CABLE UC5 TEST ‐ VALVE MODULE OUTPUT – LED (6” [0.15m])
81
13.7 44644‐16 (Rev A) ‐ CABLE BUS MONITOR CANUSB 7‐PIN CIRCULAR TEE (MALE & FEMALE DT) (42” [1.1m])
82
14 Interface Cables: Specialty
14.1 43240‐30 (Rev C) ‐ CABLE UC5 INTERFACE HARDI DAH09 (40” [1.0m])
CanadaNORAC Systems International Inc.
Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921
Shipping Address: 3702 Kinnear Place
Saskatoon, SK S7P 0A6
United States NORAC, Inc.
Phone: (+1) 952 224 4142 Toll Free: 1 866 306 6722
Shipping Address: 6667 West Old Shakopee Road, Suite 111
Bloomington, MN 55438
Europe NORAC Europe sarl
Phone: (+33) (0)4 26 47 04 42 Shipping Address: Rue de l’hermitage
01090 Guereins France