TX REMOTE CONTROL RELIO
description
Transcript of TX REMOTE CONTROL RELIO
![Page 1: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/1.jpg)
TX Remote Control FEB 2008
PAQ4411.1
TX REMOTE CONTROL RELIO
![Page 2: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/2.jpg)
TX Remote Control FEB2008
PAQ4411.1
Summary
The facts
RELIO mission
System architecture
Description
Main features
Advanced Tx remote Control
Communication
Conclusion
![Page 3: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/3.jpg)
TX Remote Control FEB 2008
PAQ4411.1
THE FACTS
![Page 4: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/4.jpg)
TX Remote Control FEB2008
PAQ4411.1
The Facts
Developed based on Clear Channel specifications
Developed in partnership with Sealevel IncSealevel designed the hardwareAudemat designed the firmware and software
400 units to be delivered Q1 2008 to Clear Channel
Now available
![Page 5: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/5.jpg)
TX Remote Control FEB 2008
PAQ4411.1
MISSION
![Page 6: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/6.jpg)
TX Remote Control FEB2008
PAQ4411.1
INTERFACING with EQUIPMENT and GATHERING DATA
Using IO (digital inputs, relays, analog inputs)to get status, levels and make actions
Using RS232 serial ports (RS422, RS485 on demand)to access console, integrate protocols with API
Using Ethernet portsSNMP concentrator (2009)
RELIO mission
![Page 7: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/7.jpg)
TX Remote Control FEB2008
PAQ4411.1
PROCESSING DATA:
Permanently check that status, levels are within tolerance and normal conditions
Run a script and trigger automatic actions when facing out of tolerance conditions
Log readings, status
Generate alarms
RELIO mission
![Page 8: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/8.jpg)
TX Remote Control FEB2008
PAQ4411.1
COMMUNICATING:
Connect to a phone line, a Intranet network, Internet, a GSM network
In order to send alarms or status via email, SMS, SNMP trap, Voice message...
RELIO mission
![Page 9: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/9.jpg)
TX Remote Control FEB 2008
PAQ4411.1
SYSTEM ARCHITECTURE
![Page 10: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/10.jpg)
TX Remote Control FEB2008
PAQ4411.1
System architecture
Typical configuration in standalone mode:
![Page 11: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/11.jpg)
TX Remote Control FEB2008
PAQ4411.1
System Architecture
Typical configuration in a regional or national network:
![Page 12: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/12.jpg)
TX Remote Control FEB 2008
PAQ4411.1
DESCRIPTION
![Page 13: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/13.jpg)
TX Remote Control FEB2008
PAQ4411.1
1U rackable unit
Linux based OS on CF card
HDD for logs
Dual 10/100BaseT Ethernet
4 RS-232/422/485, 1 RS-232
4 USB 2.0 Ports
Voice Modem with DTMF
Description
64 Digital Inputs
=> 5-30 VDC Input range
64 Digital Outputs
=> 24V @250 mA
24 Analog Inputs
=> 14-bit, Programmable Input Range
![Page 14: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/14.jpg)
TX Remote Control FEB2008
PAQ4411.1
Rear panel
![Page 15: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/15.jpg)
TX Remote Control FEB2008
PAQ4411.1
Rear panel
USB Expansion Option doubles I/O Count 1U rackable unit
![Page 16: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/16.jpg)
TX Remote Control FEB2008
PAQ4411.1
I/O panels
Separate I/O termination panels
![Page 17: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/17.jpg)
TX Remote Control FEB 2008
PAQ4411.1
SCRIPTEASY V2 Software
![Page 18: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/18.jpg)
TX Remote Control FEB2008
PAQ4411.1
2 modules
Creator moduleConfiguring the siteCreating the scriptCreation of the Voice/DTMF groups
Masterview moduleCreation of the interface with the users
Scripteasy V2
![Page 19: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/19.jpg)
TX Remote Control FEB2008
PAQ4411.1
Creator moduleConfiguring the site
Telling the software what type of remote control unit it will be running on, and the I/Os that are available
Setting up the inputs and outputs that will be connected to the remote equipment
Calibrating the analog inputs
Creating ‘virtual’ analog readings, if desired
Creator module : Configuring the site
![Page 20: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/20.jpg)
TX Remote Control FEB2008
PAQ4411.1
Creator moduleConfiguring the site
Calibrating analog inputs– Graphic interface– Read button
Creator Module : Calibrating analog inputs
![Page 21: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/21.jpg)
TX Remote Control FEB2008
PAQ4411.1
Creator moduleConfiguring the site
Creating virtual analog inputs– Using math expressions
Creator module : Creating virtual analog inputs
![Page 22: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/22.jpg)
TX Remote Control FEB2008
PAQ4411.1
Creator moduleCreating the script with the tabular method
Simple linear organization of inputs and commands
Muting, scheduling features available
Send email, Voice calls, SNMP traps
Trigger commands based on inputs or DTMF
Creator module : Tabular scripting method
![Page 23: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/23.jpg)
TX Remote Control FEB2008
PAQ4411.1
Creator moduleCreating the script with the graphic method
Drag and drop any I/O into a graphic interface. Establish relationships between objectsMany objects available (action buttons, timers, logic gates…)Simulate your script for testingPlay Mode for real-time user control
Creator module : Graphic method
Many objects to create your own script.
Inputs and Outputs
Math expressions
Logic elements (AND, OR, Inverter…)
Scheduler, Timer and Counter
Alarms
Action Buttons for live control
![Page 24: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/24.jpg)
TX Remote Control FEB2008
PAQ4411.1
In standard Vocabulary of pre-recorded 700 words Record your own message (8 kHz 16 bit mono WAV files)
Voice DTMF interface
![Page 25: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/25.jpg)
TX Remote Control FEB2008
PAQ4411.1
MasterView Designer to create and customize your viewMasterView to view it Palette with different objectsCustomize shapes, colors, import pictures, add comments
MasterView Module
![Page 26: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/26.jpg)
TX Remote Control FEB 2008
PAQ4411.1
ADVANCED TX REMOTE CONTROL
![Page 27: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/27.jpg)
TX Remote Control FEB2008
PAQ4411.1
Advanced Tx Remote Control : TCP/IP Tunneling
What is it?Tunneling is a TCP/IP gateway that can pass data from a specific IP port to a serial (RS-232) connection and send the returning data from the RS-232 back to the originating IP address and port.
What are the uses?More and more transmitting sites are getting TCP/IP connectivityBut there is still a lot of older equipment that can only use serial connections
Tunneling enables a remote access to those units via TCP/IP
How?The AA unit each have at least one serial port which can be used to establish a tunneling connection. USB ports can also be used for that applicationIn some cases, even proprietary programs can connect through a tunneling IP connection just like they were directly connected to the RS-232 of the legacy gear.
![Page 28: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/28.jpg)
TX Remote Control FEB2008
PAQ4411.1
Advanced Tx Remote Control : API
What is it?API means Advanced Program Interface. It is a powerful new tool for advanced programmers to link an AA unit (equipped with Scripteasy software) with external equipment, via one of the available serial ports. Users can write commands through the serial connection, read responses, and configure actions based on the results
What are the uses?Some equipment and devices have only serial communication ports for control and readingsThe only way to monitor or control them is to use specific commands (I.E. simple tunneling will not work, or you need automated communication)Replaces time consuming traditional IO Wiring – easily duplicated from site to site
=> The API enables permanent monitoring and control of such equipment without using traditional IO
Transmit alarms in case of faultsGenerate simple or complex actions upon events (or combinations of events)Log information about events and actions taken
![Page 29: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/29.jpg)
TX Remote Control FEB2008
PAQ4411.1
Advanced Tx Remote Control : XML-RPC
What is it?XML-RPC stands for XML Remote Procedure Call.
Commonly used by web designers and programmers, it allows creation of customized active web pages containing many types of information.
What are the uses?Allows for integration of information and functions from the AA remote control equipment into active web pages based on a remote server
Group status, measurement and control functions by station site or region
Access readings and status of any connected equipment through your own web pages and sites
![Page 30: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/30.jpg)
TX Remote Control FEB2008
PAQ4411.1
Overview capabilities
Tunneling
TCP/IP or PPP
Voice/DTMFAPI
IO
XML-RPC
SNMP
![Page 31: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/31.jpg)
TX Remote Control FEB 2008
PAQ4411.1
COMMUNICATION
![Page 32: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/32.jpg)
TX Remote Control FEB2008
PAQ4411.1
Communication : Embedded webserver
Examples of HTML pages:
Inputs / Outputs Automatic display of I/O modules Configuration of serial COM ports
(modem / tunneling / console / scriplet)
Modem • Configuration of PSTN
modem connection (port, speed, account, etc…)
Filter incoming calls
![Page 33: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/33.jpg)
TX Remote Control FEB2008
PAQ4411.1
Communication : Embedded webserver
Examples of HTML pages:
Event Log View of the events, alarms,.. Sorting by severity, type of alarms…
SNMP V2 • Capable of sending to 4 different destination addresses (Manager) Configuration of traps Life sign Complete MIB available
![Page 34: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/34.jpg)
TX Remote Control FEB2008
PAQ4411.1
Communication
Communication with embedded webserver ands Scripteasy software
Protocols:TCP/IP HTTP, SNMP, SMTP, FTP, Telnet
Voice/DTMF interface
![Page 35: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/35.jpg)
TX Remote Control FEB 2008
PAQ4411.1
BROADCAST MANAGER
![Page 36: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/36.jpg)
TX Remote Control FEB2008
PAQ4411.1
Broadcast Manager
Centralized database for alarms, measurements from various units :GoldenEagle HD, ATSC…
Relio
Mapping visualization of the controlled network
Alarms re-routing (SMS, Fax, e-mail)
Statistics
PDA visualization
![Page 37: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/37.jpg)
TX Remote Control FEB 2008
PAQ4411.1
CONCLUSION
![Page 38: TX REMOTE CONTROL RELIO](https://reader036.fdocuments.net/reader036/viewer/2022062409/56815006550346895dbdd99b/html5/thumbnails/38.jpg)
TX Remote Control FEB2008
PAQ4411.1
Conclusion
Stand alone or network solution
Integrated IP connectivity
New WYSIWYG MasterView Software
Voice/DTMF interface in standard
9 serial ports (USB, RS232) for API, tunneling
CF operating system
Local KVM support
64 digital inputs
64 control outputs
24 analog inputs