Top View Front Panel showing Programming Options drawings/P… · Analog Interface Connector Ground...
Transcript of Top View Front Panel showing Programming Options drawings/P… · Analog Interface Connector Ground...
Analog InterfaceConnector
GroundStud (M5)
HV Output
Positive Polarity
0V
CONNECT WITHOUTVOLTAGE
HighVoltage Warning Label
PHV Series Half Rack ModelTypical Front and Rear Panel Layouts
Front Panel showing Programming Options
Rear Panel
Top View
Negative Polarity
Reversible Polarity
LINE/FUSE
ANALOGPROGRAMMING
! !
!
WARNUNG
Hochspannung!Berührung kanntödlichenStromschlagverursachen!Nur spannungslosstecken!Anleitung beachten!
!WARNING
High voltage.
Contact maycause death.
Connect only
Refer to operating manual.
when outputis not live.
!
i
Standard Front Panel
Positive Polarity
Negative Polarity
Reversible
With Analog Programming
With Digital Programming
Analog & Digital Programming
DC POWER SUPPLY
TEMP
POWER OUTPUT POLARITY
POS
OFF
ON
VOLTAGESET VALUES
V-LIMIT
CURRENT
0...3.5kV 0...40mAPHV3.5P40
CV CC
kV mA
!
POWER OUTPUT POLARITY
NEGOFF
ON!
POWER OUTPUT POLARITY
NEG
POS
OFF
ON!
LOCAL
REMOTE ANALOG
PROGRAMMING
LOCAL
BUSY
DIGITAL
REMOTE
PROGRAMMING
LOCAL
BUSY
DIGITAL
REMOTE
PROGRAMMING
ANALOG
4,5 SKA-Bolzen M3x35 II KU
Befestigung aufErd-Seite = ST-SchraubenHV-Seite = KU-Schrauben
L2BV1080PM50/39
M1BV10982U100
CONNECT WITHOUTVOLTAGE! !
0V
Positive Polarity
Negative Polarity
Reversible Polarity
!ANALOG
PROGRAMMING
LINE/FUSE
PHV Series Full Rack ModelTypical Front and Rear Panel Layouts
Front Panel showing Programming Options
Rear Panel
Top View
DC POWER SUPPLY
TEMP
POWER OUTPUT POLARITY
POS
OFF
ON
VOLTAGESET VALUES
V-LIMIT
CURRENT
0...6.5kV 0...100mAPHV6.5P100
CV CC
kV mA
!
!
!
Positive Polarity
Negative Polarity
Reversible
With Analog Programming
With Digital Programming
Analog & Digital Programming
POWER OUTPUT POLARITY
NEGOFF
ON
POWER OUTPUT POLARITY
NEG
POS
OFF
ON
LOCAL
REMOTE ANALOG
PROGRAMMING
LOCAL
BUSY
DIGITAL
REMOTE
PROGRAMMING
LOCAL
BUSY
DIGITAL
REMOTE
PROGRAMMING
ANALOG
Analog InterfaceConnector
HV Output
HV
0V
WARNUNG
Hochspannung!Berührung kanntödlichenStromschlagverursachen!Nur spannungslosstecken!Anleitung beachten!
!WARNING
High voltage.
Contact maycause death.
Connect only
Refer to operating manual.
when outputis not live.
!
i
CONNECT WITHOUT VOLTAGE
ANALOGPROGRAMMING
T2AH
AC INPUT
!
!
!
PHV Series Full Rack 6U HighTypical Front and Rear Panel Layouts
DC POWER SUPPLY
TEMP
POWER OUTPUT POLARITY
POS
OFF
ON
VOLTAGESET VALUES
V-LIMIT
CURRENT
0...12.5kV 0...400mAPHV12.5P400
CV CC
kV mA
!
!
!
Positive Polarity
Negative Polarity
Reversible
With Analog Programming
With Digital Programming
Analog & Digital Programming
POWER OUTPUT POLARITY
NEGOFF
ON
POWER OUTPUT POLARITY
NEG
POS
OFF
ON
LOCAL
REMOTE ANALOG
PROGRAMMING
LOCAL
BUSY
DIGITAL
REMOTE
PROGRAMMING
LOCAL
BUSY
DIGITAL
REMOTE
PROGRAMMING
ANALOG
WARNUNG
HoherAbleitstrom!Kann zu tödlichemStromschlag führen!Nicht ohne festangeschlossenenSchulzleiterbetreiben!Anleitung beachten!
!WARNING
HIGH LEAKAGECURRENTMay cause lethalelectric shock.
Earth connection
Refer to operating manual.
essential beforeconnecting supply.
!
i