SERVICE-INFORMATION

Kutzner + Weber is certificated according to DIN EN ISO 9001:2000

GENERAL OVERVIEW

The silencer product rangeIntelligent solutions for flue and heating technology

Page 2: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

Subject Page

The company 3

Why silencers? 4

The sound levels of oil- and gas-fired forced-draught boilers 5

The solution 6–7

The low-frequency silencer 8–9

The Aktiv+ silencers 10–11

The passive silencers 12

The passive extension modules 13

The passive corner sound absorber 13

The modular system 13

The special passive silencers 14

The air-flue-gas chimney top silencer 14

The concentric flue-gas silencers 14

The passive silencers for large plants 15

The centre baffles 15

The reactive resonators 16

The vibration damper 16

The slot absorbers 17

Certificated acoustic measurement 18–19

Page 3: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

Many years experience with scientific skill and expertiseThe current climate of environmental concerns has produced a market segment where our flue products are relevant both now andin the future. Innovation has been part of our company history formore than 70 years and includes the successful Diermayer damperfor preventing heat losses, systems for locating and solving noiseproblems and devices for optimising combustion processes.

These products are born out of a desire to take a responsible attitude towards the natural environment while satisfying today'sdemands for a high level of comfort. Most of our products help toreduce atmospheric pollution. We are equally committed to bringingquiet and safety into the home. Our products help to increase thequality of life and wellbeing in each heated room by providing amore uniform burn while reducing the operating noises.

When developing new solutions, Kutzner + Weber has always workedin collaboration with scientists and researchers from establishedinstitutions. We have been operating under a licence agreement withthe Fraunhofer Institute of Building Physics as a scientific partnerfor the development of special sound absorption solutions since2001. The high quality of our products and the skill and expertisewe demand from our staff on a daily basis reflect our investment indevelopment and in the constant search for better solutions usingthe most up-to-date technology.

Customers all over the world are benefiting from our high qualityproducts and solution-oriented service. Kutzner + Weber, a subsidiaryof the Raab group, produces a full range of flue-gas products inassociation with the manufacturer of stainless-steel flue systems.We are therefore able to offer you compatible and complete elementsvirtually from a single source, for both domestic and industrialapplications.

Innovative silencer technologiesWith this brochure, Kutzner + Weber is offering scientists, consul-ting engineers, industrialists and end customers a compendium ofthe latest sound absorbing technologies which have already provedto be effective for boilers, combined heat and power plants andemergency power generators many times over.

3

The company

"High quality solutions in flue-gas noise technology help

people to protect themselvesagainst noise emissions from

their boilers."

Page 4: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

For a quiet environmentThe environmental impact from noise is constantly increasing andpeople need peace and quiet in their homes. Fortunately, noise fromdomestic appliances such as dishwashers is constantly decreasing.Modern building methods with good heat insulation and double gla-zed windows also prevent noise from entering the building fromoutside.

Modern boiler systems can also produce noise emissions as foundagain and again by residents or neighbours, particularly quiet resi-dential areas. Many of these noise problems can be solved!

With the correct advice and choice of measures on site, everyonecan contribute to a quieter environment. While doing so, the envi-ronmental regulations according to TA noise, DIN 4109 and VDIguidelines 2715 must be always be followed.

High standards for quality and functionalityKutzner + Weber is known for its high-quality products which aremanufactured to the highest standards. Many years experience inthe flue-gas technology have yielded products which are recognisedfor their quality by all who used them. Ease of installation is amajor consideration during the development of new products ofthis type. With these silencers, the highest priority is given to theirabsorption properties and an appropriately long service life.

4

The products have the following distin-guishing features:

✔ Use of high-grade stainless steels

✔ Insertion losses of all series-produced

silencers tested according to DIN EN ISO 7235

✔ No reduction in cross section, so low

flow resistances (zeta values)

✔ Special mineral fibre in passive silen-cers, therefore also suitable for use oncondensing boilers

✔ All silencers are provided with a condensate drain as standard

Available sources of informationIn order to make sure that the products are thoroughly docu-mented, Kutzner + Weber offers customers an extensive choiceof information sources which are available on request.

The following media on silencers are available:

✔ The price list which gives a quick overview of the entireproduct range

✔ The installation instructions with dimensional specifications

✔ Insertion loss leaflet with performance data for all series-produced silencers

✔ Noise measurement agencies brochure with backgroundand corresponding addresses

✔ Info. 2 "Noise control" contains a lot of interesting informa-tion about the acoustics of boilers

✔ Downloads e.g. the brochures, installation instructionsand list of noise measurement agencies from the Internetat www.kutzner-weber.de

Why silencers?

Page 5: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

5

More than 300 measured systemsKutzner + Weber has recently complied a long list of acoustic mea-surements from noise measuring agencies, supplemented by thosecarried out the company itself. With the following graph, it is possi-ble to draw some conclusions about the noise level tendencies ofoil- or gas-fired, forced-draught boilers at the chimney mouth orthe outlet of a flue-gas system. More than 300 acoustic measure-ments have also been evaluated and assigned to the different boilercapacities. However, some systems may be significantly louder.

Please note:The curves shown on the graph are typical values only. The noiselevel of a flue-gas system depends on a number of different factorssuch as the design of the boiler and the burners, the materialsused, the diameters and height of the flue-gas system and, notleast, the number of bends in the system. The best way is to specify the flue-gas sound absorbers on a case-by-case basis afterthe boiler has been commissioned. If this is not possible, then suf-ficient space should be allowed from the beginning for the silencersto be installed! The VDI guideline 2715 must also be taken intoaccount!

Frequency analyses of flue gas noises in depending on the boiler capacity (measurement at the chimney top)

The sound levels of oil- and gas-fired forced-draught boilers

32,5 63 125 250 500 1000 2000 4000 8000

90 80 70 60 50 40 30 20 10 0

soun

d pr

essu

re le

vel

frequency in Hz

level of hum

level of hum

boiler capacity from 600 kW to 1000 kWboiler capacity from 250 kW to 600 kWboiler capacity from 30 kW to 250 kWboiler capacity up to 30 kW

Frequency analyses of flue-gas noises

When running, a combu-stion appliance producesnoise both through theair and through thestructure. The noise isalso carried outside andcan be measured there aswell.

Page 6: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

6

The solution

The correct silencer for your noise problemOver the years, Kutzner + Weber has acquired a lot of experience insolving noise problems in flue-gas systems and boilers or combi-ned heat and power plants.

The fact that low-frequency noise in our environment comes fromoil- and gas-fired forced-draught burners (125 to 500 Hz) or com-bined heat and power plants (starting from 63 or 80 Hz) is nowbeyond dispute. Kutzner + Weber has found a series of solutions tothis problem which are summarised in the points below. Moredetailed descriptions for the individual products are given on thefollowing pages.

The low-frequency silencers

✔ Silencers specially designed for the noise frequen-cies concerned

✔ Optimum absorption from 50 Hz upwards

✔ Absorbs individual frequencies up to 30 dB

✔ Reduction in the level of hum by up to 25 dB(A)

✔ Broad-band absorption when used in conjunctionwith passive silencers

✔ Particularly suitably for boilers, combined heatand power plants and combustion engines

The Aktiv+ silencers

✔ Good absorption from 125 Hz onwards

✔ Reduction in the level of hum by up to 8 to 10 dB(A) (10 dB(A) perceivedaudibly as half the noise)

✔ Broad-band absorption due to passivesilencer component

✔ Very little space requirement

Page 7: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

7

The slot absorbers

✔ Developed for installation in boilers

✔ Good absorption from 125 Hz onwards

✔ Reduction in the level of hum by up to8 (10 dB(A) perceived audibly as halfthe noise)

The modular design

✔ Can be combined with differentsilencer types

✔ Improves sound absorption properties

✔ Flexibility by spatial adaptation

The reactive resonators✔ Absorb individual peak levels up to 10 dB

✔ Absorb peak levels between 80 and 250 Hz

The passive silencers

✔ Best absorption at high frequencies between 1,000 and 2,000 Hz

✔ Little absorption at low frequencies (between 80 and 250 Hz)

✔ Constant rise in damper performancetowards high frequencies

✔ Reduction in the level of hum not targeted and usually rather small

✔ Absorption improved by bend in theright-corner sound absorber

✔ Increase in the absorption properties possible by modular design

Page 8: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

8

Selective absorption of low frequenciesThe importance of low-frequency noise problems has increased inrecent years. With low frequencies between 125 and 500 Hz, thehighest noise levels in particular are generated in the flue-gassystems of boilers. With combined heat and power plants, thesehigh levels may already appear at 63 or 80 Hz, which can be heardin the environment as unpleasant "humming sounds". So far, it hasnot been possible to control this particular effect with conventionalsilencer technologies.

DesignOne special feature of the product is its fibre-free hollow chambers.The silencer has special openings so that the smooth chambers canbe easily cleaned, which may be necessary when used for dirtyflue-gas gases, e.g. flue gases contaminated with dust, soot orother combustion residues. This means that the silencer can provide unlimited performance over a long period.

A silencer has been developed for highsound absorption at low frequencies andhigh stresses under a licence agreementwith the Fraunhofer Institute of BuildingPhysics in Stuttgart. As with other productsfrom Kutzner + Weber, the low-frequencysilencers (LFS) are patent protected.

Its robust design means that the service life of the LFS is manytimes longer than those of conventional silencers. Each of the endsof the low-frequency silencers is reinforced with a clamping collarand an EPDM seal on the casing. They are provided with a conden-sate drain as standard. Plant operators who decide to use thissilencer will be delighted to know that the operating cost of theirsystem will be kept to a minimum. This is made possible by thenegligible pressure loss in the special silencer.

Mode of operationThis silencer functions on the basis of combining different resona-tors. One or more external chambers (depending on the require-ment) are acoustically coupled to the flue-gas line via a ring madeof perforated sheet steel. A specially developed computer-designprogram (see below) makes it easy to design and carry out the cal-culations for these silencers. The program takes into account theeffect of both the temperature and the flow rate.

The low-frequency silencers

Screenshot of the LFS design program

"Low-frequency noise must be controlled using

selective measures."

Example system Ring made of perforated sheetsteel for the noise inlet

Page 9: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

The design of the low frequency silencers using Kutzner + Weberapplication technology is ideally based on a frequency analysis ofthe noises from boilers or combined heat and power plants or anoise-level measurement in the third-octave spectrum. This proce-dure ensures that all noise frequencies are also actually absorbed.

Absorption propertiesThese low frequency silencers are an ideal addition to the Kutzner + Weber product range since they fill a gap in the frequencyrange previously not catered for. With many conventional solutions,low frequencies can only be absorbed by using silencers which arevery bulky, heavy and long.

ApplicationsThe low frequency silencers have been developed for reducing thenoise levels on oil- and gas-fired boilers. However, they can beused with all fuels. They can therefore easily be used on conden-sing boilers. LFSs have a long service life on plants with engines inparticular, such as combined heat and power plants or emergencypower generators. With the all-welded design, it is possible toincrease the tolerance of the silencer to heat and pressure.

9

Advantages:

✔ Absorption from 50 Hz upwards

✔ Absorption up to 30 dB possible at any frequency

✔ Reduction in the level of hum possible by up to 25 dB(A)

✔ Broad-band absorption when used in conjunction with passivesilencers

✔ Long service life

✔ Insignificant pressure loss

Because the metal chambersare open and smooth, they are

easily cleaned when accessopenings are provided.Clamping collar

with EPDM seal

Very durable high-gradestainless steel1.4571/1.4404 design

Perforated sheet steelfor noise inlet into theresonator chambers

Condensate-tightand provided with a drain

•••

Noise emission:The flue gases emergefrom here at up to +30 dBlower

Because the inner pipehas a smooth surface, the pressure loss is negligibleAll chambers

are fibre-free

Noise inlet: The flue-gases emergehere with a unique frequency spectrum. Due to the design of thesilencer, outstanding absorptionproperties are achieved on thisspectrum

Each of the chambers of the lowfrequency silencer filters out a certain

frequency range. The dimensions of the silencer are calculated by the computer design program.

Example of a low frequency silencer with three chambers

• •

Area of application:

✔ Overpressure-tight up to 1,000 Pa

✔ Flue gas temperatures up to 400° C

✔ Nominal Ø 50 to 600 mm

✔ Chimney top silencer with tailor-made mounting available

Page 10: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

Half the audibly perceived noiseModern, forced-draught boilers emit high noise levels at low fre-quencies which cannot be absorbed sufficiently by passive silen-cers. Kutzner + Weber, working in collaboration with theFraunhofer Institute of Building Physics, has developed the Aktiv+silencer with the support of the German environmental Foundation(DBU). This technology is patented.

DesignThe series ASD silencer has been developed as a porous fibreabsorber combined with an active module mounted at right angleson the side. The principal component, which is mounted on theside of the silencer, is a compact, metal cartridge which houses aloudspeaker, microphone, amplifier and power supply. In order toshield the components from flue gas, a special foil is provided asan interface to the flue channel.

Silencers with diameters larger 180 mm are supplied with an addi-tional outlet on the side, a reactive resonator.

The Aktiv+ silencer can also be extended if necessary by removingthe ends and adding further modules.

Mode of operationThe operating principle is based on the increase in the soundabsorption of well-known resonators by electro-acoustic activation.With the microphone in direct proximity to the loudspeaker dia-phragm, the diaphragm movements are increased by means of anamplifier to produce a significant improvement in the hollow cham-ber effect (Helmholtz principle) in the module mounted on the side.This creates the optimum sound absorption conditions for the low-frequency flue-gas noises within a very short length of chamber.

The Aktiv+ silencers

10

Passive (without amplification)

Sound pressure Resonator

=

membrane mass capable of vibration+compressible pneumatic spring

Active (with amplification)

Sound pressureAmplified membrane vibration

Microphone

Loudspeaker

Amplifier

Page 11: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

11

Absorption propertiesDue to the successful combination of a passive and Aktiv+ silencer,the Aktiv+ silencer is particularly suitable for the sound absorptionof frequencies between 125 to 2,000 Hz.

ApplicationsThe Aktiv+ silencer can be used for reducing the noise from oil-and gas-fired boilers and can be easily used in the flue-gas systemof condensing boilers. For this reason, the electronic componentsare protected by a special foil and the condensate is safely carriedaway via the flue gases. However, they are not suitable for use oncombined heat and power plants and units.

Advantages:

✔ Can be mounted in tight spaces

✔ Absorbs low frequencies from125 Hz upwards

✔ Almost halves the noise

✔ Insertion loss according to DIN EN ISO 7235 available and can be requested

Active resonator

Electrical connection (230 V)(can be installed or pluggedinto the boiler controller)

Passive silencer parallel todirection of flow

Simple and space-savinginstallation

Condensate-tight andfitted with a drain

Clamping collar with EPDM seal

Manufactured fromstainless steel1.4571/1.4404

••

• •

Area of application:

✔ Overpressure-tight up to 200 Pa

✔ Flue gas temperatures up to200°C

✔ Nominal Ø 80 to 300 mm

Page 12: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

DesignThese series AGM flue-gas silencers are porous sound absorbers(mineral fibre). The mineral fibre is protected against abrasion by astainless steel fleece. The expanded metal provides inherent dura-ble stability. The ends of the silencers can be removed and thesilencers extended with the appropriate modules. All silencers areprovided with a condensate drain (which must always be connec-ted) as standard.

Mode of operationThe mineral fibre used by Kutzner + Weber is very fine with anopen porous structure. The passive silencer reduces the noise byabsorbing the sound energy by friction against the fibres as noisepasses through. Different types of mineral fibre were acousticallytested according to DIN EN 29053-B at the Fraunhofer Institute ofBuilding Physics in order to determine the flow resistance and findthe optimum mineral fibre.

Absorption propertiesThe passive silencers are particularly suitable for reducing the noiselevel of medium and high frequencies. Their optimum absorption isachieved between 1,000 and 2,000 Hz. When the overall length islarger, low frequencies can also be damped.

ApplicationsSeries AGM silencers are suitable for use with all regular combusti-on heating appliances and can be used on condensing boilers with-out restriction.

The passive silencers

Manufactured fromstainless steel1.4571/1.4404

Mineral fibre absorption core ofhydrophobic (less sensitive todamp) design

Condensate-tight andfitted with a drain

Clamping collar forsilencer ends with

EPDM seal

Sound absorbent carri-er made from expan-ded stainless steel andstainless steel fleece toprotect the absorptioncore

Silencer end with pipeunions

12

••

• •

Page 13: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

13

The internal structure of the AVM series extension modules are ofidentical design to the passive silencers mentioned above. Thenoise level can be noticeably reduced by extending the standardsilencer.

Passive silencers also include the series AWM angled silencerswhich therefore have the same structure. The right-angled design isoften the only option for installing silencers in boiler rooms wherespace is very restricted. Often, the space is not sufficient for instal-ling the standard tubular sound absorbers

Due to their modular design, the series AGM, AVM, AWM, ASD andLFS silencers can be used in combination with each other.

To make sure that the connections are safe, supporting collarsmust be fitted inside at the factory. Extra wide sealing collars andextra wide sealing tape can be used to connect and seal the outercasing of the two modules.

Advantages:

✔ Modular design

✔ Hydrophobic, condensate-repellent mineral fibre

✔ Mineral fibre acoustically tested according toDIN EN 29053-B (flow resistance)

✔ Insertion loss according to DIN EN ISO 7235available and can be requested

The passive extension modules

The passive corner sound absorber

The modular system

✔ Sound absorption improved by angular design

✔ Suitable for cramped conditions

AWM

AVM

ASD Connection collar as a vibration damper

AGM

Area of application

✔ Overpressure-tight up to 1,000 Pa

✔ Flue-gas temperatures up to 400° C

✔ Nominal Ø 80 to 350 mm

✔ Chimney top silencers with tailor-made mounting available

Advantages of the modular design:

✔ Optimum use can be made of the availablespace

✔ The silencers can be extended when soundabsorption needs to be increased.

✔ The noise frequencies can be targeted precisely by selecting the appropriate soundabsorption technology

Page 14: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

14

When space is really tightBecause space is sometimes tight in boiler rooms, it is not alwayspossible to install silencer technology with standard products. Thisis where the specially designed silencers, such as those with cer-tain angular designs or with connections at a certain position,come into use. The Kutzner + Weber production facility is ideallysuited to meet these market requirements and has already produ-ced "creative" silencer solutions.

Supply air and flue-gas in oneThese silencers were developed particularly for installation in con-centric flue-gas systems with 80/125 mm nominal diameters. Thedesign of the actual absorbing body corresponds to that of theseries AGM passive silencer. They are of double-walled design, sothat the combustion air can be sucked through the annular gap andare intended for use on condensing boilers etc. They are fitted witha condensate drain as standard.

Preventing noise emissions into the neighbourhoodAnother special silencer was developed particularly for the outlet offlue-gas systems of 80 mm nominal diameter. The design of theactual absorbing body corresponds to that of the series AGM pas-sive silencer described above.

It is designed to take the combustion air of an air-flue-gas system.These silencers are typically used for noise which is emitted fromthe chimney outlet into the neighbourhood. They can be retrofittedwithout the need for significant structural alteration.

The special passive silencers

The concentric flue-gas silencers

The chimney top silencerArea of application:

✔ Nominal Ø 80 mm

✔ Connections to the outlet

✔ Suitable for air-flue-gasoperation

"Where standard solutions do not fit, help is on

hand from the Kutzner + Weber development department."

Area of application:

✔ For nominal Ø 80/125 mm

✔ Concentric design

✔ Suitable for air-flue-gas operation

Page 15: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

15

The passive silencers for large plants

Large nominal diameters also possibleThe ARE series silencers are designed for large plants and areavailable for a nominal diameter of 400 mm upwards.

DesignThe sound absorption material consists of mineral fibre. Themineral fibre is protected against abrasion by a stainless steelfleece. Perforated sheet steel is used to give it shape and stability.The ends of the silencers are welded to the casing, so these silen-cers can be used at larger overpressures. A condensate drain isprovided as standard.

Mode of operationThe mineral fibre used by Kutzner + Weber is very fine with anopen porous structure. The passive silencer reduces the noise byabsorbing the sound energy from the noise by friction against thefibres as it passes through. Different types of mineral fibre havebeen acoustically tested according to DIN EN 29053-B at theFraunhofer Institute For Building Physics, in order to determine theflow resistance and find the optimum mineral fibre.

Absorption propertiesThe passive silencers are particularly suitable for the sound levelreduction of medium and high frequencies. Their optimumabsorption is achieved between 1,000 and 2,000 Hz.

ApplicationsSeries ARE silencers are suitable for use on all regular combusti-on heating appliances and can be used on condensing boilerswithout restriction.

For large cross sections with nominal diameters greater than 350 mm, the sound absorption of the silencers is improved by theinclusion of centre baffles. The centre baffles (type AME) are installed in AGM silencers of nominal diameter 350 mm and all ARE series silencers specified above.

Area of application:

✔ Overpressure-tight up to 5,000 Pa

✔ Flue-gas temperatures up to 400° C

✔ Nominal Ø 400 to 800 mm

✔ Chimney top silencers with tailor-made mounting available

Advantages:

✔ Long service life due to high-grade stainless steel 1.4571/1.4404

✔ Hydrophobic, condensate-repellent mineral fibre

✔ Mineral fibre protected by perforated sheet steel

✔ Mineral fibre acoustically tested according to DIN EN 29053-B (flow resistance)

Advantage:

✔ Improved reduction in noise level

The centre baffles

Page 16: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

Used as connection collars, structure-borne sound absorbers arealso easy to connectThe structure-borne sound absorbers made from EPDM reducesound vibrations generated by the flue-gas system and compensa-te for thermal expansion.

They are particularly suitable for simple connection between boilerconnectors and the flue-gas system downstream etc.

The reactive resonators

16

A special solution which needs little spaceReactive resonators can be used to reduce individual prominentpeak levels. These resonators are flanged on the side, either on aT-piece or on a passive silencer. For dimensioning, a calculationmust be carried out on an individual basis for a specified frequencyand temperature. Reactive resonators do not contain fibre materialand are therefore not subject to wear and are maintenance-free andof robust design.

Advantages:

✔ For reducing peak levels up to 10 dB

✔ For low frequencies up to 400 Hz

✔ Very little space requirement

Advantages:

✔ Simple appliance connector

✔ Compensation up to 10 mm

✔ Pressure- and condensate-tight connection up to 200 Pa

✔ For flue-gas temperatures up to 200°C

✔ Nominal Ø 80 to 500 mm

The vibration damper

Page 17: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

Inconspicuous but effectiveWith this type of silencer, the sound can be reduced immediatelyafter the source of noise. Slot absorbers can be adapted to themost complicated space conditions in boilers in order to exploitany available space to reduce the level of noise.

Slot absorbers have been developed in close collaboration with theFraunhofer Institute of Building Physics. Kutzner + Weber was thefirst to introduce them as a product ready for the market. Thismethod of sound adsorption is patent protected.

DesignThe porous absorbers used in these silencers are almost comple-tely covered by discs with narrow slots. The design of the slitwidth and slot distances for a stipulated frequency range wasarrived at by using a computer program specially developed forthe purpose. The silencer dimensions can therefore be specified.

Mode of operationThe slot absorbers operate in a similar way to conventional reso-nators. However, unlike Helmholtz resonators for example, theycan be adapted to wider bands.

Absorption propertiesThe silencers start to absorb sound at a frequency of approx. 125 Hz. They can reduce the level of hum in the ideal case by up to 8 dB, which is perceived audibly as almost half the noise.

Advantages:

✔ Dimensions and geometry according to customer

requirement

✔ Sound absorption in restricted spaces

✔ Particularly suitable for installation in boilers

✔ Wide range of options in shape and size

✔ Very robust design

✔ Proven in series operation

17

The slot absorbers

They are made from high-grade stainless steel 1.4571/1.4404 and are also suitable for use at high temperatures.

These slot absorbers are made from the high-grade PP plastics. Their housings arewelded complete and are overpressure tight.

Page 18: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

Certificated acoustic measurement

Solving noise problemsWith its current range of a few hundred items, Kutzner + Weberis well placed to solve noise problems on the basis of acousticmeasurement. Kutzner + Weber can therefore offer its customersa comprehensive service. An extensive network of sound measu-rement agents is on hand for carrying out acoustic measure-ments in Germany, Austria, Hungary and Switzerland. All soundmeasurement agents have to attend training courses run by theFraunhofer Institute of Building Physics (IBP), Brüel & Kjaer andKutzner + Weber.

All acoustic measurements are carried out using Class 1 sound-level measurement equipment..

18

"Quick acoustic measurements throughout Germany, Austria,

Hungary and Switzerland."

Page 19: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

19

Only selected and trained agents receive the Kutzner + Weber certificate

Advantages at a glance

✔ Solution to noise problem guaranteedKutzner + Weber undertakes to guarantee solving the noiseproblem for appliances where the silencers have been desig-ned on the basis of an acoustic measurement by in-houseapplication technology.

✔ Certificated acoustic measurement agentsSound measurements are only carried out by agencies whoregularly attend the training courses run by the FraunhoferInstitute of Building Physics (IBP), Brüel & Kjaer andKutzner + Weber. These agencies receive a certificate fromKutzner + Weber.

✔ Cost-optimised silencersBased on the available third-octave spectra, silencers canbe provided with the optimum design, so oversizing is avoided.

✔ Rapid problem solvingAcoustic measurements are offered fast and flexibly.

✔ Easy search of sound measurement agency The sound measurement agent can be easily found on theInternet at www.kutzner-weber.de/service. For Germany andAustria, the measurement agent is selected by a postcodesearch of where the measurement is to be carried out.

✔ Cost-effective acoustic measurementsThe sound measurement agents charge a uniform price forcarrying out the sound measurements, according to theexpense.

✔ Installing the silencers Because of their many years experience in flue-gas techno-logy, the sound measurement agents are able to installsilencers if necessary according to customer requirement.

✔ Class 1 measurement equipmentAll sound measurement agents use a recognised and reliable, Class 1 sound-level measurement instrument fromBrüel & Kjaer.

"We advise on solving noise problems

using acoustic measurements based on scientific

investigations"

With the low frequency silencer (LFS), the chambers are calculated for the specified frequency

range beforehand on an individual basis. The necessary third frequencies are provided by an acoustic measurement.

Page 20: The silencer product range - Kutzner+ · PDF fileSERVICE-INFORMATION Kutzner + Weber is certificated according to DIN EN ISO 9001:2000 GENERAL OVERVIEW The silencer product range Intelligent

Kutzner + Weber GmbH

Frauenstraße 32

D-82216 Maisach

Tel.: +49 (0) 81 41 / 9 57-0

Fax: +49 (0) 81 41 / 9 57-5 00

www.kutzner-weber.de

[email protected]