THE FIREHOUSE PROJECTCHICAGO, IL

1
M-1 RADIANT PANEL LAYOUT AND BILL OF MATERIAL DATE REV. JP drawn by: date: RECORD PRINT APPROVAL 07/01/19 06 03 19 DESCRIPTION NOTE: DEDUCT 25 SQ. FT. PANEL AREA FROM LOOP 4 FOR ISLAND. THE FIREHOUSE PROJECT CHICAGO, IL 1 MANIFOLD LOOP # LENGTH LOOP SCHEDULE 2 PANEL AREA 3 4 1 193 SQ. FT. 188'-5" 51 SQ. FT. 55'-7" 150 SQ. FT. 147'-2" 338 SQ. FT. 313'-2" 23 FIRST FLOOR PANEL LAYOUT SCALE: 1/4" = 1'-0" M-4 L-6 L-6 L-9 L-10 TUBING DROP POINT CUSTOM GROOVE PLYWOOD OR GROUT BED FILLER (TYPICAL) TRIM PANEL AS REQ'D CUSTOM FIELD GROOVE AS REQ'D 2 5 263 SQ. FT. 272'-11" 6 87 SQ. FT. 82'-9" 3 7 223 SQ. FT. 219'-7" 8 265 SQ. FT. 253'-6" 9 205'-11" 4 10 273'-4" BATH LOOP 6 1'-11 1/2" 3'-11" 1'-11 1/2" 3'-11" FIELD TRIM EACH PIECE TO FIT DESIGNATED OPENING. HALF COMBO 1/2 HORIZONTAL COMBO WITH 2 HALF CURVES 1/2 HORIZONTAL COMBO-BOTTOM 1/4 COMBO WITH 2 QUARTER CURVES 1/4 COMBO WITH HALF CURVE HALF COMBO 1/4 COMBO WITH 2 QUARTER CURVES 1/4 COMBO WITH HALF CURVE 1/4 COMBO WITH 2 QUARTER CURVES 1/8 COMBO LRH 1/8 COMBO LLH PANEL ITEM NUMBER PANEL ITEM NUMBER MANUFACTURED GROOVES TO ACCEPT PEX TUBING NOTE: ACTUAL PANEL SIZES MAY DIFFER SLIGHTLY FROM CAD DRAWING REPRESENTATION. TOTAL ECOWARM PANELS TO BE DELIVERED : STRAIGHTS: 109 EA. COMBOS: 93 EA. ECOWARM FLOOR PANEL NOTES: 1-STRAIGHT PANEL LENGTHS SHOWN ARE APPROXIMATE. FIELD MEASURE AND CUSTOM CUT EACH PANEL TO FIT DESIGNATED LOCATION. SEE INSTILLATION AND DESIGN MANUAL FOR DETAILED PROCEDURES. 2-WHEN CALCULATING FIELD CUT COMBO PANELS DEDUCT FOR SAW CUT WIDTH. 3-EXCESSIVE WASTE MAY DICTATE NEED TO UTILIZE MULTIPLE SALVAGED PANEL PIECES (2" MIN.) TO FILL PANEL LOCATIONS. 4-THE LAYOUTS PROVIDED ARE BEST ESTIMATE ONLY. ALWAYS REFER TO THE DESIGN AND INSTILLATION MANUAL FOR ALL DESIGN AND INSTILLATION RELATED INFORMATION. THE DESIGN AND INSTILLATION MANUAL SUPERCEDES ANY LAYOUT NOTATIONS. COMBINATION STRAIGHT PANEL FIELD CUT PANEL TYPES TO BE FIELD CUT FROM STRAIGHT AND COMBO PANELS PANEL SIZES SHOWN ARE APPROXIMATE, FIELD MEASURE EACH OPENING AND CUSTOM CUT EACH PANEL TO FIT. L-3 INDICATES MANIFOLD # TUBE FLOW DIRECTION LOOP # PEX TUBING MANIFOLD LEGEND TUBING FROM LOOP DROP POINT INSULATED TUBING FROM ECOWARM FLOOR PANEL EXIT (IN WALLS, ETC.) TO THE MANIFOLD LOCATION.

Transcript of THE FIREHOUSE PROJECTCHICAGO, IL

Page 1: THE FIREHOUSE PROJECTCHICAGO, IL

M-1

RA

DIA

NT

P

AN

EL LA

YO

UT

AN

D B

ILL O

F M

AT

ER

IA

L

DA

TE

RE

V.

JP

dra

wn

b

y:

da

te

:

RE

CO

RD

PR

IN

T

AP

PR

OV

AL

07

/0

1/1

9

06

0

3 1

9

DE

SC

RIP

TIO

N

NOTE:

DEDUCT 25 SQ. FT. PANEL AREA

FROM LOOP 4 FOR ISLAND.

THE

FIR

EHO

USE

PR

OJE

CT

CH

ICA

GO

, IL

1

MANIFOLD LOOP # LENGTH

LOOP SCHEDULE

2

PANEL AREA

3

4

1

193 SQ. FT.188'-5"

51 SQ. FT.55'-7"

150 SQ. FT.147'-2"

338 SQ. FT.313'-2"

23

FIRST FLOOR PANEL LAYOUT

SCALE: 1/4" = 1'-0"

M-4

L-6

L-6

L-9

L-10

TUBING DROP

POINT

CUSTOM GROOVE

PLYWOOD OR

GROUT BED

FILLER (TYPICAL)

TRIM PANEL AS REQ'D

CUSTOM FIELD

GROOVE AS REQ'D

2

5

263 SQ. FT.272'-11"

6

87 SQ. FT.82'-9"

3

7

223 SQ. FT.219'-7"

8

265 SQ. FT.253'-6"

9

205'-11"

4

10

273'-4"

BATH

LOOP 6

1'-1

1 1

/2

"

3'-11"

1'-1

1 1

/2

"

3'-11"

FIELD TRIM EACH PIECE TO FIT DESIGNATED OPENING.

HALF COMBO

1/2 HORIZONTAL COMBO

WITH 2 HALF CURVES

1/2 HORIZONTAL

COMBO-BOTTOM

1/4 COMBO WITH 2

QUARTER CURVES

1/4 COMBO WITH HALF

CURVE

HALF COMBO

1/4 COMBO WITH 2

QUARTER CURVES

1/4 COMBO WITH HALF

CURVE

1/4 COMBO WITH 2

QUARTER CURVES

1/8 COMBO LRH

1/8 COMBO LLH

PANEL ITEM

NUMBER

PANEL ITEM NUMBER

MANUFACTURED GROOVES

TO ACCEPT PEX TUBING

NOTE:

ACTUAL PANEL SIZES MAY

DIFFER SLIGHTLY FROM CAD

DRAWING REPRESENTATION.

TOTAL ECOWARM PANELS TO BE DELIVERED:

STRAIGHTS: 109 EA.

COMBOS: 93 EA.

ECOWARM FLOOR PANEL NOTES:

1-STRAIGHT PANEL LENGTHS SHOWN ARE APPROXIMATE. FIELD

MEASURE AND CUSTOM CUT EACH PANEL TO FIT DESIGNATED

LOCATION. SEE INSTILLATION AND DESIGN MANUAL FOR

DETAILED PROCEDURES.

2-WHEN CALCULATING FIELD CUT COMBO PANELS DEDUCT FOR

SAW CUT WIDTH.

3-EXCESSIVE WASTE MAY DICTATE NEED TO UTILIZE MULTIPLE

SALVAGED PANEL PIECES (2" MIN.) TO FILL PANEL LOCATIONS.

4-THE LAYOUTS PROVIDED ARE BEST ESTIMATE ONLY. ALWAYS

REFER TO THE DESIGN AND INSTILLATION MANUAL FOR ALL

DESIGN AND INSTILLATION RELATED INFORMATION.

THE DESIGN AND INSTILLATION MANUAL SUPERCEDES ANY

LAYOUT NOTATIONS.

COMBINATION STRAIGHT

PANEL FIELD CUT

PANEL TYPES TO BE FIELD CUT FROM STRAIGHT AND COMBO PANELS

PANEL SIZES SHOWN ARE APPROXIMATE, FIELD MEASURE EACH OPENING AND CUSTOM CUT EACH PANEL TO FIT.

L-3

INDICATES MANIFOLD #

TUBE FLOW DIRECTION

LOOP #

PEX TUBING

MANIFOLD

LEGEND

TUBING FROM LOOP

DROP POINT

INSULATED TUBING

FROM ECOWARM

FLOOR PANEL EXIT (IN

WALLS, ETC.) TO THE

MANIFOLD LOCATION.