The Automation Component AK 1703 ACP - Home - Siemens · PDF fileType designation Subrack...
Transcript of The Automation Component AK 1703 ACP - Home - Siemens · PDF fileType designation Subrack...
The Automation ComponentAK 1703 ACPPower made to measure
Power Transmission and Distribution
Automation, communication and telecontrol
High functionality and fl exibili-ty are the basis for a successful automation system. And when you use the AK 1703 ACP, you can be sure it also includes comprehensive telecontrol and communications functions and options for linking peripheral equipment.
One for all: AK 1703 ACPThe AK 1703 ACP opens up new possibilities for the automation
of power supply networks through innovative technologies such
as the ACP system concept. You can match the performance
and redundancy of the system perfectly to your requirements
through an extremely fl exible combination of automation,
telecontrol and communication functions.
AK 1703 ACP offers you optimum support for this as
a central unit or telecontrol substation,
data node or front-end,
automation unit with independent
function groups and
with local or remote peripherals.
At the same time, AK 1703 ACP offers a wide range of different
interfaces for local and remote communications. Compatibility
with IEC standards 60870-5-101/103/104 is guaranteed by
consistent addressing from acquisition to output. However,
AK 1703 ACP can also be integrated seamlessly into existing
automation networks via many different third-party protocols,
thereby ensuring the long-term protection of your investments.
Intelligent peripheralsApart from the central acquisition and output of process signals
in the AK 1703 ACP subrack the use of TM 1703 peripheral
elements allows a systematic reduction in the number of hard-
wired I/O interfaces through the direct connection of actuators
and sensors with wire cross sections of up to 2.5 mm2. Modules
for binary input and output up to 220 V DC also open up savings
potential at the interposing level. The TM 1703 peripheral
elements can also be placed as far away as 200 m from the
central unit for decentralized input/output.
Consistently simple engineeringThe engineering process, from system diagnosis to online test,
can be implemented extremely cost-effectively via the object-
oriented SAT Toolbox II system, and also remotely. The close
interfacing with design tools such as ELCAD ensures the
consistent, uniform documentation of the whole system right
down to circuit diagram level. User programs for open-loop and
closed-loop control functions are created in CAEx plus in
accordance with IEC 61131-3, thereby minimizing training
costs.
Simple replacement: Plug & PlayA fl ash card is used in the AK 1703 ACP for storing parameters,
so that exchanging devices is a simple Plug & Play operation.
The confi guration is transferred to the spare device with the
fl ash card. As a result, loading from a PC is not necessary and
the correct parameters are always available locally. This allows
comprehensive remote diagnosis options, and down times can
be reduced to a minimum.
Confi gurable telecontrol functions
with and without time tagging
Time synchronization via minute
pulse, time signal receiver, serial
communications link or NTP server
(LAN/WAN)
Data routing via selective or automatic
data fl ow
Uniform functionality as per IEC
60870-5-101/103/104 for consistent
addressing from acquisition to output
Scalable redundancy through:
– Duplication of 1 to 5 processing/
communication elements
– Duplication of the whole automation
unit
Independent functional groups
Decentralized archive
Standby transmission route concept
Parameter setting, diagnostics and
testing by means of SAT Toolbox II
both locally and from remote locations
Storage of parameters and fi rmware
on fl ash card
Architecture Multi-processor and fi rmware principle
with 32-bit processor technology
One master control element with
– up to 2 communication interfaces
– automation function
– connection to the SAT Toolbox II
engineering system
Up to 16 additional processing and
communication elements
Up to 66 protocol elements for
– serial communication (point-to-
point, multi-point, dial-up traffi c)
– LAN/WAN (Ethernet)
– Profi bus DP
Up to 272 peripheral elements
Overview of functions Node function for building up multi-
hierarchical networks with virtually
any topology
Automation functions at all levels of
a local or distributed network
Drawing up a function plan according
to IEC 61131-3 with CAEx plus for
open-loop and closed-loop control
functions
AK 1703 ACP In practical operation
Confi gurations
NTP
Process control system SAT Toolbox II
Central unit:– Local input/output
– Central processing
Station control unit:– Process coupling
(serial, wide)
– Node function
– Automatic functions
TC substation:– Local processing
– Decentralized acquisition
– Turbine controller
– Power plant management
– Automation & control
– Data node
– Front end
– Gateway
AK 1703 ACP
AK 1703 ACPAK 1703 ACPAK 1703 ACP
AK 1703 ACP
Type designation
Subrack CM-2832CM-2835
AK 1703 ACP subrack for 9 slots
AK 1703 ACP subrack for 17 slots
Master control element CP-2010/CPC25 System functions, processing and communication
Processing andcommunication element
CP-2012/PCCE25 Processing and communication
Peripheral elements DI-2100/BISI25DI-2110/BISI26DI-2111/BISI26DO-2210/PCCO2xDO-2211/PCCO2xDO-2201/BISO25AI-2300/PASI25MX-2400/USIO2x
Binary signal input (8 x 8, 24–60 VDC)
Binary signal input (8 x 8, 24–60 VDC), 1 ms resolution
Binary signal input (8 x 8, 110/220 VDC), 1 ms resolution
Secured command output 24–60 VDC
Secured command output 110–125 VDC
Binary output (transistor, 40 x 1, 24–60 VDC)
Analog input/output (16 x ±20 mA + 4 x 2 opt. exp.)
Signal input/output (24–60 VDC, ±20 mA, opt. exp.)
Power supply PS-5620PS-5622
Power supply module, 24–60 VDC
Power supply module, 110–220 VDC, 115–230 VAC
Open-loop and closed-loop control function(per master control/
processing element)
256 kB for user program
approx. 50,000 variables and signals, 2,000 of which buffered
250 buffered nominal values
Third-party protocols Modbus, DNP 3.0, IEC 61107, various ABB, Siemens, L&G, AEG, ...
EMC IEC 60870-2, IEC 60255, IEC 60654, IEC 60950, IEC 61000, EN50082, CISPR 22, ...
Temperature range 0 ... +55 °C
Relative humidity 5 to 95 % non-condensing (IEC 60654-1 C2, IEC 60870-2-2 C2)
Vibration and shock resistance IEC 60870-2-2 Cl. Bm, IEC 60255-21-1 Cl.2, IEC 60255-21-2 Cl.2
Dimensions CM-2832: 280 x 291 x 285 mm (W x H x D); space requirement: 400 x 451 x 290 mm (W x H x D)
CM-2835: 483 x 291 x 285 mm (W x H x D); space requirement: 604 x 451 x 290 mm (W x H x D)
Technical data
Applications As telecontrol substation or central
unit
With local or remote peripherals
As data node, front-end or gateway
Automation unit with independent
functional groups
For rear panel or 19” rack installation
Comprehensive communication Up to 66 serial interfaces for local
and remote communication
Communication (serial, LAN/WAN)
as per IEC 60870-5-101/103/104
and IEC 61850
Numerous third-party protocols
available
Profi bus DP
Scalable redundancy Component redundancy
Duplication of processing/
communication elements
AK 1703 ACP –The advantages at a glance
Simple engineering and maintenance Creation of user programs for open-
loop and closed-loop control functions
as per IEC 61131-3
Object-oriented engineering
Consistent data storage
Engineering also possible from remote
locations
Plug & Play for spare parts by means of
fl ash card
Storage of parameters and fi rmware
on fl ash card
Exchanging of modules without
engineering tool
TM 1703: The intelligent terminal Direct connection of actuators and
sensors with wire cross-sections of up
to 2.5 mm2
Remote installation possible
up to 200 m away
Binary input/output also f or
110/220 VDC
Mounting on 35 mm DIN rail
Siemens AG
Power Transmission
and Distribution
Energy Automation Division
P.O. Box 4806
90026 Nuremberg
Germany
www.siemens.com/energy
The information in this document contains general
descriptions of the technical options available, which
do not always have to be present in individual cases.
The required features should therefore be specified
in each individual case at the time of closing the
contract.
Subject to change without prior notice.
Order No. E50001-U321-A251-X-7600
Printed in Germany
Dispo 06200
TH 345-060137 101789 PA 04062.0
If you have any question about
Power Transmission and Distribution,
our Customer Support Center
is available around the clock.
Tel.: +49 180/524 70 00
Fax: +49 180/524 24 71
(Subject to charges, e.g.: 12 ct/min.)
E-mail: [email protected]
www.siemens.com/energy-support