TERMINAL LEGEND ELECTRICAL STANDARDS
Transcript of TERMINAL LEGEND ELECTRICAL STANDARDS
K14
0 1 2 3 4 5 6 7 8 9 N 0 1 2 3 4 5 6 7 8 9 N
-F11
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
U
V
W
OFF AUTOMANUALSTART RELAY 14,15, 23, 44
THERMAL O/LAUXILIARY RELAY20, 30, 88
K28
THERMAL O/LRESET SOLENOID6
K33RESET
MOTOR OVERTEMPRELAY61, 92
-F1
K80K35
RESET RELAY40, 68
LINE 92
PLC DIGITAL INPUTSMOTOR HEALTHYK28
MOTOR RUNNING K14
REMOTE RESET35
K80
PLC DIGITAL OUTPUT
OFF AUTOMANUAL
AUTO SELECTED
xxx-yyy
OVERLOADAK28
Qnn4A
T1
Qnn4A
RK20RUNNING
K37
K35
K37
MOTOR THEMISTORS
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
LINE 25MCC MOTOR
STARTER TERMINAL
PLC PANEL TERMINAL
TERMINAL LEGEND
MOTOR TERMINAL
FIELD TERMINAL
EQUIPMENT TERMINAL
1. THIS DRAWING IS TYPICAL ONLY.
CONTRACTOR SHALL MODIFY TO SUIT
THE EQUIPMENT OFFERED.
2. xxx DENOTES EQUIPMENT NUMBER.
yyy DENOTED WIRE NUMBER.
3. PTC MOTOR THERMISTORS SHALL BE
FITTED TO MOTORS RATED 5.0kW AND
UP TO 75kW WITH RTDs FITTED TO MOTORSGREATER THAN 75kW.
4. ALTERNATIVELY APPROVED PLUG SOCKETCOMBINATIONS .
5. INSTALL HEATERS WHERE APPLICABLE.
6. FOR FIXED SPEED MOTORS GREATER THAN7.5kW SOFT STARTERS SHALL BE USED.
NOTES
SEE NOTE 4
SEE NOTE 4
R01
W01
B01
R02
W02
B02
K20MOTOR ANTI-COND.HEATERS
xxx-103 HT1 QnnN
DECONTACTOR
LOCALDECONTACTOR
K20 RUN CONTRACTOR3, 90
K14
SEE NOTE 5
K20
PLC OUTPUT
RUN CALL
START
LOCAL CONTROL STATION
STOP
K20
K28LOCKOUT STOP
LOCKOUT STOP STOPACTIVATED
xxx-yyyLOCKOUT STOP
A
B
C
D
E
F
G
A
B
C
D
E
F
G
9 10 11 1256
7 82 3 41
H
A1
REV
10 11 12
NUMERAL
DO NOT SCALE
DRAWING NUMBER
SCALE:
546
7 9
DRAWN
DESIGN CHECK DRAFT CHECK SE WATER
APPROVED
DESIGNED COMPANY
82 3
APP'DDATEREVISION
H
1
ZONEREV.
SOUTH EAST
M:\S
hared\M
&E
D
raw
ings In P
rogress\S
EW
M
D
rive\A
Standard D
raw
ings\D
raw
ings T
o C
orrect - K
EV
IN
\E
_S
RP
_S
TD
_001r0 D
OL S
tarter S
chem
atic D
iagram
T
ypical Lockout S
top.dw
gH
ogan, K
evin
SCALE BAR
E-SRP-STD-001 0
ELECTRICAL STANDARDS
MOTOR STARTER
DOL STARTER WITH LOCKOUT STOP
SCHEMATIC DIAGRAM (TYPICAL)
J.Myyrlainen
21/6/17
J.M.
21/6/17
J.M.
21/6/17
J.M.
21/6/17
J.M.
21/6/17
0 DRAWN FOR SEW TREATMENT PLANT STANDARDS 21/6/17 J.M.
KSR
PLC OUTPUT
RUN CALL
STARTSTOP
K20
K14
0 1 2 3 4 5 6 7 8 9 N 0 1 2 3 4 5 6 7 8 9 N
-F11
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
U
V
W
xxx-400X
K60
xxx-401X
xxx-402
E/STOP
X
xxx-403X
A1
E
23
A2
S21
24
S22
13
S31
14
S32 33
34
K35
KSRPILZ SAFETY
RELAY PNOZ 16S
407
408
406
OFF AUTOMANUAL
THERMAL O/LAUXILIARY RELAY20, 30, 88
K28
THERMAL O/LRESET SOLENOID6
K33RESET
MOTOR OVERTEMPRELAY61, 92
-F1
EMERGENCYSTOPRELAY 20, 71, 86
K80K35
RESET RELAY40, 68
LINE 92
PLC DIGITAL INPUTS
EMERGENCY STOPACTIVATED
MOTOR HEALTHY K28
MOTOR RUNNING K14
REMOTE RESET35
K80
PLC DIGITAL OUTPUT
OFF AUTOMANUAL
AUTO SELECTED
K60
xxx-yyy
Y1
Y2
404
405
K60
S12
S11
OVERLOADAK28
Qnn4A
T1
Qnn4A
RK20RUNNING
K37
K35
K37
MOTOR THEMISTORS
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
LINE 21MCC MOTOR
STARTER TERMINAL
PLC PANEL TERMINAL
TERMINAL LEGEND
MOTOR TERMINAL
FIELD TERMINAL
EQUIPMENT TERMINAL
NOTES
SEE NOTE 4
SEE NOTE 7
SEE NOTE 4
R01
W01
B01
R02
W02
B02
0V DC24V DC
0VDC24VDC
101
102[14]
K20MOTOR ANTI-COND.HEATERS
xxx-103 HT1 QnnN
DECONTACTOR
LOCALDECONTACTOR
K20 RUN CONTRACTOR3, 90
K14
SEE NOTE 5
LOCAL CONTROL STATION
LOCAL CONTROL STATION
START RELAY 14,15, 22,44
K20K28
1. THIS DRAWING IS TYPICAL ONLY.
CONTRACTOR SHALL MODIFY TO SUIT
THE EQUIPMENT OFFERED.
2. xxx DENOTES EQUIPMENT NUMBER.
yyy DENOTED WIRE NUMBER.
3. PTC MOTOR THERMISTORS SHALL BE
FITTED TO MOTORS RATED 5.0kW AND
UP TO 75kW WITH RTDs FITTED TO MOTORSGREATER THAN 75kW.
4. ALTERNATIVELY APPROVED PLUG SOCKETCOMBINATIONS .
5. INSTALL HEATERS WHERE APPLICABLE.
6. FOR FIXED SPEED MOTORS GREATER THAN7.5kW SOFT STARTERS SHALL BE USED.
7. SAFETY RELAYS SHALL BE INSTALLED
BASED ON A MACHINE SAFETY
ASSESSMENT TO AS4024.
K60
A
B
C
D
E
F
G
A
B
C
D
E
F
G
9 10 11 1256
7 82 3 41
H
A1
REV
10 11 12
NUMERAL
DO NOT SCALE
DRAWING NUMBER
SCALE:
546
7 9
DRAWN
DESIGN CHECK DRAFT CHECK SE WATER
APPROVED
DESIGNED COMPANY
82 3
APP'DDATEREVISION
H
1
ZONEREV.
SOUTH EAST
M:\S
hared\M
&E
D
raw
ings In P
rogress\S
EW
M
D
rive\A
Standard D
raw
ings\D
raw
ings T
o C
orrect - K
EV
IN
\E
_S
RP
_S
TD
_002r0 D
OL S
tarter S
chem
atic D
iagram
T
ypical E
merg S
top.dw
gH
ogan, K
evin
SCALE BAR
E-SRP-STD-002 0
ELECTRICAL STANDARDS
MOTOR STARTER
DOL STARTER WITH EMERGENCY STOP
SCHEMATIC DIAGRAM (TYPICAL)
J.Myyrlainen
21/6/17
J.M.
21/6/17
J.M.
21/6/17
J.M.
21/6/17
J.M.
0 DRAWN FOR SEW TREATMENT PLANT STANDARDS 21/6/17 J.M.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
0 1 2 3 4 5 6 7 8 9 N 0 1 2 3 4 5 6 7 8 9 N
L1
L2
L3
PE
T2
T3
SOFTSTARTER
DANFOSSMCD500
L1
L2
L3
T1
18
17
25
21
22
7
8
Qxx
L
L
L
C
C
C
R
W
B
E
K46
K57 RUNNING
xx A
LINE 53
DOOR MOUNTEDOPERATORINTERFACE
QnnN
100
E/STOP
B1
E
23
B2
S21
24
S22
S31
S32
S33
S34
KSRPILZ SAFETY
RELAY PNOZ 16S
Qnn4A
Qnn4A
13
14
FAULT
LINE 55
6
COMPARTMENTHEATER
5
PROFINET
NA
200
201
202
R01
W01
B01
R02
W02
B02
24VDC
xxx-400
xxx-401
xxx-402
xxx-403
0VDC
408
102
406
407
K57
K55
T1
220 299
100 QxxN
13
221
221
228
229
MOTOR ANTI-COND.HEATERS
HT1
SSFAULT
1 3 FAULT RELAY46, 61, 96
K53
RESET RELAY18,79
K57RESET
229
231
OFF AUTOMANUAL
RUN RELAY15, 44
K85
REMOTEFAULT RESET
58
K85
PLC DIGITAL OUTPUT
AFAULT
GK55MOTOR RUNNING
SSMOTOR RUNNING4 5 MOTOR RUNNING RELAY
36, 63, 98
K55230
K53
221
232
221
233
EMERGENCY STOPACTIVATED
MOTOR HEALTHYK53
OFF AUTOMANUAL
AUTO SELECTED
PLC DIGITAL INPUTS
xxxxxx xx
299
299
299
K46K53PLC OUTPUT RUN
221 227
START
LOCAL CONTROL STATIONSTOP
K46
xxx-224xxx-222
xxx-223
RESET
0V DC24V DC
0VDC24VDC
K55
xxx-yyy
MOTOR RUNNING
K70
LINES 92
xxx-224xxx-225
PLC OUTPUT FAULTxxx-231xxx-221
NOTE 6
Y1
Y2
404
405
K70
S12
S11
U
V
W
LOCALDECONTACTOR
SEE NOTE 4
ANALOG OUT
Qnn
100
xxx-103
HT2
QnnN103
xxx-203 xxx-204
K70226
LINE 61 LINE 61
LINE 61 LINE 61
xxx-300
xxx-301
K70299
14
100
101[34]
EMERGENCYSTOPRELAY 46, 77, 94
LINES 48
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
MCC MOTOR
STARTER TERMINAL
PLC PANEL TERMINAL
TERMINAL LEGEND
MOTOR TERMINAL
FIELD TERMINAL
EQUIPMENT TERMINAL
16
15
PROFINET PROFINET
HT1
DECONTACTOR
R03
W03
B03
EMERG STOP CONTACTOR3,
K34KSR101
K34
NOTES
1. THIS DRAWING IS TYPICAL ONLY.
CONTRACTOR SHALL MODIFY TO SUIT
THE EQUIPMENT OFFERED.
2. xxx DENOTES EQUIPMENT NUMBER.
yyy DENOTED WIRE NUMBER.
3. PTC MOTOR THERMISTORS SHALL BE
FITTED TO MOTORS RATED 5.0kW AND
UP TO 75kW WITH RTDs FITTED TO MOTORSGREATER THAN 75kW.
4. ALTERNATIVELY APPROVED PLUG SOCKETCOMBINATIONS .
5. INSTALL HEATERS WHERE APPLICABLE.
6. SAFETY RELAYS SHALL BE INSTALLED
BASED ON A MACHINE SAFETY
ASSESSMENT TO AS4024.
7. IF SAFETY RELAY NOT REQUIRED,
INSTALL LOCKOUT STOP. FOR GENERAL
ARRANGEMENT REFER DRAWING
E-SRP-STD-001.
8. SOFT STARTER SHOWN MOUNTED IN THE
MCC. LARGER UNITS MAYBE MOUNTED
SEPARATELY.
SEE NOTE 5
A4 A6100
A
B
C
D
E
F
G
A
B
C
D
E
F
G
9 10 11 1256
7 82 3 41
H
A1
REV
10 11 12
NUMERAL
DO NOT SCALE
DRAWING NUMBER
SCALE:
546
7 9
DRAWN
DESIGN CHECK DRAFT CHECK SE WATER
APPROVED
DESIGNED SEWRA
82 3
APP'DDATEREVISION
H
1
ZONEREV.
SOUTH EAST
C:\M
ichael B
ackup\17b. N
ew
B
oards 2020\S
TP
S
tandard D
raw
ings\E
_S
RP
_S
TD
_003 S
oft S
tarter S
chem
atic D
iagram
T
ypical.dw
g
SCALE BAR
E-SRP-STD-003 1
ELECTRICAL STANDARDS
MOTOR STARTER
SOFT STARTER
SCHEMATIC DIAGRAM (TYPICAL)
J.Myyrlainen
21/6/17
J.M.
21/6/17
J.M.
21/6/17
J.M.
21/6/17
J.M.
21/6/17
0 DRAWN FOR SEW TREATMENT PLANT STANDARDS 21/6/17 J.M.
1 REVISED TO PROFINET & ADDED S/S CONTROL VOLTAGE 27/11/19 M.LIM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
0 1 2 3 4 5 6 7 8 9 N 0 1 2 3 4 5 6 7 8 9 N
VSDUNIT
L1
L2
L3
PE
U
V
W
18
VSDUNIT
DANFOSSVLT AQUA
L1
L2
L3
U
V
W
PE
12
18
32
1
3
42
39
Qxx
L
L
L
C
C
C
R
W
B
E
K47
K57 RUNNING
xx A
LINE 53
DOOR MOUNTEDOPERATORINTERFACE
QnnN
100
E/STOP
B1
E
23
B2
S21
24
S22
S31
S32
S33
S34
KSRPILZ SAFETY
RELAY PNOZ 16S
Qnn4A
Qnn4A
27 4
5
FAULT
LINE 55
33
COMPARTMENTFAN
COMPARTMENTHEATER
19K48
NA
NA
TH2
54AUTO SPEEDREFERENCE
200
201
200
203
204
R01
W01
B01
R02
W02
B02
24VDC
xxx-400
xxx-401
xxx-402
xxx-403
0VDC
408
101
102
406
407
K57
xxx-206
xxx-207
K55
K55
TH1
T1
220 299
100 QxxN
13
221
221
228
229
MOTOR ANTI-COND.HEATERS
HT1
VSDFAULT
1 3 FAULT RELAY47, 61, 96
K53
RESET RELAY18,79
K57RESET
228
230
OFF AUTOMANUAL
RUN RELAY15
K85
REMOTEFAULT RESET
58
K85
PLC DIGITAL OUTPUT
VSDSETUP 217
K48
AFAULT
GK55MOTOR RUNNING
VSDMOTOR RUNNING4 5 MOTOR RUNNING RELAY
34, 37, 63, 98
K55229
K53
221
231
221
232
EMERGENCY STOPACTIVATED
MOTOR HEALTHYK53
OFF AUTOMANUAL
AUTO SELECTED
PLC DIGITAL INPUTS
xxxxxx xx
299
299
299
299
K47K53PLC OUTPUT RUN
221 227
START
LOCAL CONTROL STATIONSTOP
K47
xxx-224xxx-222
xxx-223
55
RESET
0V DC24V DC
0VDC24VDC
K55
xxx-yyy
MOTOR RUNNING
K70
LINES 92
xxx-224xxx-225
PLC OUTPUT FAULTxxx-231xxx-221
NOTE 2
Y1
Y2
404
405
K70
S12
S1153
208
209
500-5 K ohmMANUAL SPEED REFERENCE
SEE NOTE 5
37KSR 202
ANALOG OUT
Qnn
100
xxx-103
HT2
QnnN103
xxx-200 xxx-205
K70226
225
LINE 61 LINE 61
LINE 61 LINE 61
xxx-300
xxx-301
K70299
14
200
202
[72]
[16]
EMERGENCYSTOPRELAY 47, 77, 94
LINES 48
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
MCC MOTOR
STARTER TERMINAL
PLC PANEL TERMINAL
TERMINAL LEGEND
MOTOR TERMINAL
FIELD TERMINAL
EQUIPMENT TERMINAL
LOCALDECONTACTOR
U
V
W
SEE NOTE 5
xxx-200
xxx-205
NOTES
1. THIS DRAWING IS TYPICAL ONLY.
CONTRACTOR SHALL MODIFY TO SUIT
THE EQUIPMENT OFFERED.
2. xxx DENOTES EQUIPMENT NUMBER.
yyy DENOTED WIRE NUMBER.
3. PTC MOTOR THERMISTORS SHALL BE
FITTED TO MOTORS RATED 5.0kW AND
UP TO 75kW WITH RTDs FITTED TO MOTORSGREATER THAN 75kW.
4. ALTERNATIVELY APPROVED PLUG SOCKETCOMBINATIONS .
5. INSTALL HEATERS WHERE APPLICABLE.
6. SAFETY RELAYS OR DRIVES WITH
APPROVED SAFETY CIRCUITS SHALL BE
INSTALLED BASED ON A MACHINE
SAFETY ASSESSMENT TO AS4024.
7. IF SAFETY RELAY NOT REQUIRED,
INSTALL LOCKOUT STOP. FOR GENERAL
ARRANGEMENT REFER DRAWING
E-SRP-STD-001.
8. VSD SHOWN MOUNTED IN THE MCC.
LARGER UNITS MAYBE MOUNTED
SEPARATELY.
PROFINET
PROFINET PROFINET
A
B
C
D
E
F
G
A
B
C
D
E
F
G
9 10 11 1256
7 82 3 41
H
A1
REV
10 11 12
NUMERAL
DO NOT SCALE
DRAWING NUMBER
SCALE:
546
7 9
DRAWN
DESIGN CHECK DRAFT CHECK SE WATER
APPROVED
DESIGNED SEWRA
82 3
APP'DDATEREVISION
H
1
ZONEREV.
SOUTH EAST
C:\U
sers\m
lim
\D
ow
nloads\N
ew
_A
rchive_20191127T
103326\E
_S
RP
_S
TD
_004 V
SD
S
tarter S
chem
atic D
iagram
T
ypical.dw
g
SCALE BAR
E-SRP-STD-004 1
ELECTRICAL STANDARDS
MOTOR STARTER
VARIABLE SPEED DRIVE
SCHEMATIC DIAGRAM (TYPICAL)
J.Myyrlainen
21/6/17
J.M.
21/6/17
J.M.
21/6/17
J.M.
21/6/17
J.M.
21/6/17
0 DRAWN FOR SEW TREATMENT PLANT STANDARDS 21/6/17 J.M.
1 REVISED TO PROFINET 27/11/19 M.LIM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
0 1 2 3 4 5 6 7 8 9 N 0 1 2 3 4 5 6 7 8 9 N
QxxR
W
B
E
xxA
QnnN
T1
200 299
100 QnnN
Qnn4A
Qnn
R01
W01
B01
VALVE OPENSTATUS RELAY95
K35207
1
2
3
E
33
35
5
CONTROL VALVEACTUATOR
PLC ANALOG INPUTVALVE POSITION(4-20mA)
CLS
OPN
24V+
22
23
8 9
7
VALVEACTUATOR
ZSC
ZSOOPENED
CLOSED
VALVE OPENH37
W
VALVE CLOSEDSTATUS RELAY 97
K40208
VALVE CLOSEDH42
W
43
FAULT
FAULT RELAY93
K45209
ACTUATOR FAULTH47
A
42
xxx-301
ROTORK IQxxx-300
Qnn4A
CLOSE AUTOOPEN
201
LINES 89
PLC OUTPUT
PLC OUTPUT
xxx-203
xx-204
xxx-205
xxx-205
OPENRELAY10, 31
K29
CLOSERELAY11, 29
K31
K31
K29
6
K29
K31
VALVE SHOWN IN CLOSED POSTION
203
204
205
206
xxx-201 xxx-207
xxx-208
xxx-209
E/STOP
B1
E
23
B2
S21
24
S22
S31
S32
S33
S34
KSRPILZ SAFETY
RELAY PNOZ 16S
24VDC
xxx-400
xxx-401
xxx-402
xxx-403
0VDC
408
406
407
K82
13
RESET
0V DC24V DC
0VDC24VDC
NOTE 2
Y1
Y2
404
405
K57
S12
S11
K57299
14
220
223[16]
EMERGENCYSTOPRELAY 64, 91
25
31
4
ESD
24V-
KSR
SAFETY RELAY
xxx-223
xxx-222
xxx-221
xxx-220
EMERGENCY SHUTDOWN. CONFIGURE FOR EITHER VALVE CLOSE, OPEN OR
STAYPUT OPERATION
REMOTEFAULT RESET
66
K82
PLC DIGITAL OUTPUT
EMERGENCY STOPACTIVATED
ACTUATOR FAULTK45
CLOSE AUTOOPEN
AUTO SELECTED
PLC DIGITAL INPUTS
K40
xxx-yyy
VALVE OPEN
K57LINES 30
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
xxx-yyy
K35 xxx-yyy
VALVE CLOSED
MCC MOTOR
STARTER TERMINAL
PLC PANEL TERMINAL
TERMINAL LEGEND
MOTOR TERMINAL
FIELD TERMINAL
EQUIPMENT TERMINAL
NOTES
SEE NOTE 3
DECONTACTOR
LOCALDECONTACTOR
1. THIS DRAWING IS TYPICAL ONLY.
CONTRACTOR SHALL MODIFY TO SUIT
THE EQUIPMENT OFFERED.
2. xxx DENOTES EQUIPMENT NUMBER.
yyy DENOTED WIRE NUMBER.
3. ALTERNATIVELY APPROVED PLUG SOCKETCOMBINATIONS .
4. SAFETY RELAYS OR ACTUATORS WITH
APPROVED SAFETY CIRCUITS SHALL BE
INSTALLED BASED ON A MACHINE
SAFETY ASSESSMENT TO AS4024.
E-SRP-STD-005 0
ELECTRICAL STANDARDS
VALVE ACTUATOR
SCHEMATIC DIAGRAM (TYPICAL)
J.Myyrlainen
21/06/17
J.M.
21/06/17
J.M.
21/06/17
J.M.
21/06/17
J.M.
21/06/17
0 DRAWN FOR SEW TREATMENT PLANT STANDARDS 21/06/17 J.M.
A
B
C
D
E
F
G
A
B
C
D
E
F
G
9 10 11 1256
7 82 3 41
H
A1
REV
10 11 12
NUMERAL
DO NOT SCALE
DRAWING NUMBER
SCALE:
546
7 9
DRAWN
DESIGN CHECK DRAFT CHECK SE WATER
APPROVED
DESIGNED SEWRA
82 3
APP'DDATEREVISION
H
1
ZONEREV.
SOUTH EAST
M:\S
hared\M
&E
D
raw
ings In P
rogress\S
EW
M
D
rive\A
Standard D
raw
ings\D
raw
ings T
o C
orrect - K
EV
IN
\E
_S
RP
_S
TD
_005 V
alve A
ctuator S
chem
atic D
iagram
T
ypical.dw
g
SCALE BAR