241 TCPO 07÷11 - TCPV 16÷35 Pools Heat pump horizontal and vertical expulsion TCPO 07 - 09 -11 horizontal expulsion TCPV 16 - 20 - 24 - 35 vertical expulsion Model TCPO 07 with horizontal expulsion TCPO 09 with horizontal expulsion TCPO 11 with horizontal expulsion TCPV 16 with vertical expulsion TCPV 20 with vertical expulsion TCPV 24 with vertical expulsion TCPV 35 with vertical expulsion Code 39000000 39000001 39000002 39000003 39000004 39000005 39000006 Power Thermal kW 6,95 8,98 10,99 16,51 19,81 24,21 35,26 Pool volume* m 3 < 40 < 50 < 60 < 95 < 115 < 140 < 200 3.770,00 4.380,00 4.780,00 7.780,00 8.500,00 9.680,00 14.180,00 * Volumes expressed as an indication. For the actual estimate, it is appropriate to consider the specific characteristics of each pool (according to the thermal study).

Transcript of TCPO 07÷11 - TCPV 16÷35 - accorroni.it · 242 TCPO 07÷11 - TCPV 16÷35 Pools Heat pump...

241

TCPO 07÷11 - TCPV 16÷35Pools Heat pump horizontal and vertical expulsion

TCPO 07 - 09 -11horizontal expulsion

TCPV 16 - 20 - 24 - 35vertical expulsion

Model

TCPO 07 with horizontal expulsionTCPO 09 with horizontal expulsionTCPO 11 with horizontal expulsionTCPV 16 with vertical expulsionTCPV 20 with vertical expulsionTCPV 24 with vertical expulsionTCPV 35 with vertical expulsion

Code

39000000390000013900000239000003390000043900000539000006

PowerThermal kW

6,958,98

10,9916,5119,8124,2135,26

Pool volume*m3

< 40< 50< 60< 95< 115< 140< 200

3.770,004.380,004.780,007.780,008.500,009.680,00

14.180,00* Volumes expressed as an indication. For the actual estimate, it is appropriate to consider the specific characteristics of each pool (according to the thermal study).

242

TCPO 07÷11 - TCPV 16÷35Pools Heat pump horizontal and vertical expulsion

4 good reasons to choose heaters for heat pumps for swimming pools

1) Titanium heat exchanger: safety guaranteeand reliability All heat pump heaters A2B Accorroni E.G. are equipped with a titanium exchanger able to heat any type of water, regardless of the origin and treatment used (chlorine treatment, salt, bromine, ozone sterilization, etc.) and all plants with extensive disinfection requirements . The titanium alloy ensures maximum protection, guaranteed over time, against corrosion caused by chlorine.

2) EvaporatorThe evaporator of the TPCV units from 16 to 35 kW is made of hydrophilic aluminum fins and internally grooved copper tube to increase its heat exchange capacity, efficiency and corrosion resistance.All heat pump heaters A2B Accorroni E.G. work with R410A refrigerant fluid.

3) Resistant materials: ABS pump bodyAll units are covered by an external shell in thermoformed ABS that is not subject to corrosion. This coating makes it possible to install all the products in the open air, without the risk of deterioration caused by atmospheric agents or the need for special maintenance.

4) Heat in silenceHeat pump heaters A2B Accorroni E.G. boast the best noise levels on the market today: up to a minimum of 32 dB(A)

All heat pump heaters A2B Accorroni E.G. they can be installed in an easy and immediate way: by simply connecting the swimming pool and the system, the hot water produced will be directly inserted between the inlet and outlet pipes of the unit.

Diagram of heat pump system for swimming pools TCPO 07 ÷ 11 - TCPV 16 ÷ 35

Light Light

Water jet

Main exhaust

Filter

exhaust

Heat pump

Pump

Entrance

243

Dimensions TCPV 16 ÷ 35 vertical expulsion

TCPO 07÷11 - TCPV 16÷35Pools Heat pump horizontal and vertical expulsion

Dimensions TCPO 07÷11 horizontal expulsion

L

P

A

666,

51.074,7

400

TCPVLPA

16702700

842,5

19751750

892,5

24751750

892,5

35901920

1056Values expressed in mm

244

DESCRIPTIONPerformance at the following conditions: outside air temperature 15 °C / water temperature inlet 13 °CThermal powerAbsorbed powerCurrent consumptionCOPPerformance at the following conditions: outside air temperature 15 °C / inlet water temperature 26 °CThermal powerAbsorbed powerCurrent consumptionCOPPerformance at the following conditions: outside air temperature 20 °C / inlet water temperature 24 °CThermal powerAbsorbed powerCurrent consumptionCOPCompressorR410A Refrigerant GasWater flow

Adjustable water temperature range Heating

Cooling downAir temperature rangePower supplySound levelDegree of protectionNet weight

TCPO 07÷11 - TCPV 16÷35Pools Heat pump horizontal and vertical expulsion

DESCRIPTIONPerformance at the following conditions: outside air temperature 15 °C / water temperature inlet 13 °CThermal powerAbsorbed powerCurrent consumptionCOPPerformance at the following conditions: outside air temperature 15 °C / inlet water temperature 26 °CThermal powerAbsorbed powerCurrent consumptionCOPPerformance at the following conditions: outside air temperature 20 °C / inlet water temperature 24 °CThermal powerAbsorbed powerCurrent consumptionCOPCompressorR410A Refrigerant GasWater flow

Adjustable water temperature range Heating

Cooling downAir temperature rangePower supplySound levelDegree of protectionNet weight

TPCO 07

6,951,115,126,26

6,291,285,854,91

6,981,205,485,82

0,953,10

15÷408÷28

-10÷43

32

49

TPCO 09

8,981,446,606,24

8,281,697,694,90

9,041,556,965,83

Rotary1,303,95

15÷408÷28

-10÷43230V/1/50Hz

33IPX454

TPCO 11

10,991,809,106,11

10,182,089,924,89

11,201,949,335,77

1,504,80

15÷408÷28

-10÷43

34

61

U.M.

kWkWA

kWkWA

kWkWA

kWkg

m3/h°C°C°C

dB(A)

kg

Technical data table TCPO 07÷11 horizontal expulsion

TPCV 16

16,512,68

13,686,16

15,022,95

15,065,10

16,983,00515,155,65

2,504,2÷8,615÷408÷28

-10÷43230V/1/50Hz

32

103

TPCV 20

19,813,235,516,13

18,013,555,995,07

20,353,626,105,62Scoll2,70

5,1÷10,415÷408÷28

-10÷43

33

110IPX4

TPCV 24

24,213,936,326,16

22,014,316,945,11

24,904,406,935,66

3,406,3÷12,615÷408÷28

-10÷43400V/3+N/50Hz

34

116

TPCV 35

35,265,789,306,10

32,056,41

10,325,00

36,306,47

10,195,61

4,609,2÷18,015÷408÷28

-10÷43

35

166

U.M.

kWkWA

kWkWA

kWkWA

kWkg

m3/h°C°C°C

dB(A)

kg

Technical data table TCPV 16 ÷ 35 vertical expulsion