Sysmex XE 5000

download Sysmex XE 5000

of 17

Transcript of Sysmex XE 5000

  • 5/24/2018 Sysmex XE 5000

    1/17

    INTRODUCING

    OUR NEW

    PRODUCT

    SYSMEX XE 5000

  • 5/24/2018 Sysmex XE 5000

    2/17

    A BRIEF INTRODUCTION

    The Sysmex XE-5000 Automated Hematology System utilizes thepower of fluorescent flow cytometry and hydrodynamic focusingtechnologies.

    Using a unique and advanced diode laser bench, Sysmex fluorescentflow cytometry provides the sensitivity needed for measuring anddifferentiating cell types in whole blood and body fluid samples.

    Fluorescent technology and hydrodynamic focusing enable the XE-5000 to consistently differentiate normal WBC, RBC and PLT

    populations from abnormal populations, thereby decreasing thenumber of manual interventions.

    The XE-5000 technology provides clinically relevant and reportableparameters.

  • 5/24/2018 Sysmex XE 5000

    3/17

    Reportable parameters

    43 parametersCBC (14 parameters)

    WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MPV, P-LCR, PDW, PCT

    DIFF (12 parameters)NEUT%, LYMPH%, MONO%, EO%, BASO%, IG%, NEUT#, LYMPH#,MONO#, EO#, BASO#, IG#

    NRBC (2 parameters)

    NRBC%, NRBC#,

    RET (8 Parameters)

    RET%, RET#, LFR, MFR, HFR, IRF, RET-He, IPF, (PLT-O)

    Body Fluid (6 parameters)

    WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#

    -HPC

  • 5/24/2018 Sysmex XE 5000

    4/17

    SPECIFICATIONS

    Principles & TechnologiesFluorescent Flow Cytometry:

    WBC-Diff, IG, NRBC, RET, IRF, PLT-ORF-DC method:HPCDC-Sheath-Flow:PLT, RBC, HCTSLS-Method:Hgb

    Linearity WBC: 0 440.00 x 103/LRBC: 0 8.00 x 106/LPLT: 0 5,000 x 103/L

    Body Fluid Linearity WBC-BF: 0.000 10.000 x 103/LTC-BF: 0.000 10.000 x 103/LRBC-BF: 0.000 5.000 x 106

    /L

  • 5/24/2018 Sysmex XE 5000

    5/17

    SPECIFICATIONS

    Throughput Whole Blood Mode:150 samples/hr (max.)Body Fluid Mode:38 samples/hr (max.)

    Sample Volumes 200L / 130L (manual closed

    mode/open mode)40L for capillary mode

    Data Storage(IPU: Information Processing Unit)

    10,000 samples (incl. graphics)

    Interfaces Sysmex WAM (HL7 & ASTM)

  • 5/24/2018 Sysmex XE 5000

    6/17

    SPECIFICATIONS

    Quality Control (Total QC Management) Levey-Jennings control chartX-bar M fileOnline QC

    Dimensions / Weightw x h x d [in] / [lbs]

    Main unit: 27.8" x 35.9" x 28" / 178 lbs.Sampler: 22.8" x 7.7" x 14.8" / 26 lbs.IPU: 18" x 17.6" x 5.3" / 24 lbs.

    Configurations Stand aloneSysmex HST-N, Sysmex XE-AlphaN

  • 5/24/2018 Sysmex XE 5000

    7/17

    TARGET CUSTOMER

    SUITABLE FOR LAB WHICH RECEIVESGREATER NUMBER OF SAMPLES PER DAY

    SUITABLE FOR LAB WITH LESS STAFFS ASOUR ANALYZER IS AUTOMATED ANDREQUIRES LESS MANPOWER.

  • 5/24/2018 Sysmex XE 5000

    8/17

    XE-5000 ANALYSIS PRINCIPLE

    Laser Flow Cytometry

    ShealthFlow/Hydrodynamic Focusing DC

    detection RF/DC Detection Method

    SLS Heamoglobin Method

  • 5/24/2018 Sysmex XE 5000

    9/17

    FLUOROSCENCE FLOW CYTOMETRY

  • 5/24/2018 Sysmex XE 5000

    10/17

    DC-HYDRODYNAMIC FOCUSING

  • 5/24/2018 Sysmex XE 5000

    11/17

    XE-5OO0 MULTICHANNEL ANALYZER

    CHANNEL PRINCIPLE PARAMETERSWBC/BASO Flow cytometry WBC,Baso #, BasoNRBC Flow cytometry NRBC #, NRBC %4 Diff Flow cytomtery Lymph# , Lymph%

    Mono#, Mono%Eo# , Eo%

    Neut# , Neut%IG# , IG%

    RET/PLT-O Flow cytometry RET#, RET%,PLT-O,HFR, MFR, LFR, IRF

    RET-He, IPFIMI

    RF/DC-detectionmethod HPC#

    HGB SLS-Method,photometry HGBMCH,MCHC,MCV

    RBC/PLT-Detector HDF DC-Detectionmethod RBC,HCT,PLT-I,RDW-SD, RDW-CV, PDW,

    MPV, P-LCR

  • 5/24/2018 Sysmex XE 5000

    12/17

    REAGENT SYSTEM

  • 5/24/2018 Sysmex XE 5000

    13/17

    OUTPUT

  • 5/24/2018 Sysmex XE 5000

    14/17

    WHY SYSMEX XE-5000??

    Integrated Sysmex SP-Series automatedslide maker/stainer.

    eMM software provides more specificflagging.

    Measure body fluids.

    Advanced parameters

  • 5/24/2018 Sysmex XE 5000

    15/17

    WHY SYSMEX XE-5000 ?

    HIGH THROUGHOUTPUT

    NO NEED OF SAMPLE PREPARATION

    SHORTENED TURN AROUND TIME

    REDUCED SAMPLE VOLUME LESS LIKEHOOD OF TRANSCRIPTIONAL ERRORS

    PROVIDES 7 SCATTERGRAMS AND 2HISTOGRAM FOR A BETTER ANALYSIS

    RANKED BY THIRD PARTY AS HIGHEST VENDORFOR RELIABILITY FOR 8 CONSECUTIVE YEARS INA ROW*

  • 5/24/2018 Sysmex XE 5000

    16/17

    CUSTOMER SERVICE

    In-time deliveries of reagents andconsumable

    Instrument repair and maintenance including

    hot-line support Consultancy and management of complex

    laboratory installation projects

    Continuous post-market surveillance andfeedback of market requirements as designinput for new product development

    Management of customer events

  • 5/24/2018 Sysmex XE 5000

    17/17