Sub-Octa Abutment System Sub Octa Abutment
description
Transcript of Sub-Octa Abutment System Sub Octa Abutment
59Ⅳ. Components of Dentis Products |
Part 1
Abutment Diameter Code No.DIOHCØ4.8
Abutment Diameter Code No.DSOA480DSOA481DSOA482DSOA483DSOA484DSOA485
Ø4.8
Sub Octa Abutment
Impression Coping
Octa Healing Cap
TypeAbutment Diameter Code No.DIOIODIOIN
DIOTI
Pick-Up
Pick-Up
Transfer
Transfer
Ø4.8
Cuff1 m m1 . 5 m m2 . 5 m m3 . 5 m m4 . 5 m m5 . 5 m m
Sub-Octa Abutment System
60
Abutment Diameter Code No.DIOLAØ4.8
Lab Analog
Gold Cylinder TypeAbutment Diameter Code No.DIOGCODIOGCN
OctaN-Octa
Ø4.8
O c t a
N - O c t a
61Ⅳ. Components of Dentis Products |
Part 1
Plastic Cylinder TypeAbutment Diameter Code No.DIOPODIOPN
OctaN-Octa
Ø4.8
N - O c t a
O c t a
Sub-Octa Abutment System
62
O-Ring AbutmentO-Ring Abutment Driver
O-Ring Lab Analog
Healing Abutment
Submerged Fixture
Cover Screw
O - R i n g O-Ring Retainer
1.25 Hex Driver
4) O-Ring Abutment System
63Ⅳ. Components of Dentis Products |
Part 1
O-Ring Abutment System
O-Ring Abutment
Cuff: 0.5, 2, 4mm
Code No.DOLA
Code No.DOR
O-Ring Retainer
O-Ring Lab Analog
Code No.ORING
O - R i n g
CuffAbutment Diameter Code No.DSORA00DSORA20DSORA40
0.5mm2mm4mm
Ø3.4Ø4.5Ø4.5
3. Dentis External Implant System Flow
External Fixture
64
Fixture Mount can be used for Imperssion Coping and Free Abutment.
Fixture mount is economical and makes it simple for dental prosthetics.
Mount could be used as transfer type of impression coping and final
abutment after inserted fixture.
Tapered design
Root Form Design achieved superb initial fixation strength also in places
where condition of the bone is not good, makes an easy and stable
surgery possible and reduces surgery time.
Micro-Thread for Bone Loss Prevention
It prevents water absorption of the cortex due to bacterial infection and
minimizes bone loss, breaking due to internal stress and stimulus of the
cortical bone with stable initial fixation strength and wedges in thin cor-
tex as well.
Safe cutting edge
It minimizes resistance of the bone during insertion of the implant and
functions to provide safe and smooth insertion.
RBM Surface Treatment (1.5-1.8um)
It maximizes osseointegration.
×5 , 0 0 0
×5 0
65Ⅳ. Components of Dentis Products |
Part 1
W i d e
P l a t f o r mD i a m e t e r
L e n g t h C o d e
ø5 . 1
8 . 0 m m
1 0 . 0 m m
1 2 . 0 m m
1 4 . 0 m m
D E F W 5 1 0 8
D E F W 5 1 1 0
D E F W 5 1 1 2
D E F W 5 1 1 4
I m p l a n tD i a m e t e r
ø5 . 1
R e g u l a r
P l a t f o r mD i a m e t e r
L e n g t h C o d e
ø4 . 1
8 . 0 m m
1 0 . 0 m m
1 2 . 0 m m
1 4 . 0 m m
D E F R 4 1 0 8
D E F R 4 1 1 0
D E F R 4 1 1 2
D E F R 4 1 1 4
I m p l a n tD i a m e t e r
ø4 . 1
M i n i
P l a t f o r mD i a m e t e r
L e n g t h C o d e
ø3 . 5
8 . 0 m m
1 0 . 0 m m
1 2 . 0 m m
1 4 . 0 m m
D E F M 3 5 0 8
D E F M 3 5 1 0
D E F M 3 5 1 2
D E F M 3 5 1 4
I m p l a n tD i a m e t e r
ø3 . 5
ø3.5
0.7㎜
ø2.8
ø2.4
L
ø4.1
0.7㎜
ø3.4
ø2.7
L
ø5.1
0.7㎜
ø4.4
ø3.4
L
External Implant System Products
66
Healing Abutment 1.2 Hex Driver
External Fixture
Cover Screw
Impression Coping(Transfer)Impression Coping(Pick-up)
Angled Abut. Gold UCLACemented Abut. Plastic UCLA
1 5。 2 5。N - H e xH e x N - H e x
N - H e x
H e x
H e x
N - H e xH e x
M o u n t
Prosthetic Flow Diagrams for External Type Implant
1) Cemented Abutment System
Lab Analog
67Ⅳ. Components of Dentis Products |
Part 1
Cemented Abutment System
Cuff: 2, 3, 4, 5.5, 7mm
6.5mm
Healing Abutment
M o u n t Platform Diameter Code No.DEFMM
DEFMR
DEFMW
Mini
Regular
Wide
Short Mount Platform Diameter Code No.DEFMSM
DEFMSR
DEFMSW
Mini
Regular
Wide
Cover Screw Platform Diameter Code No.DECSM
DECSR
DECSW
Mini
Regular
Wide
CuffPlatform Diameter Code No.DEHM420DEHM430DEHM440DEHM455DEHM470
DEHR520DEHR530DEHR540DEHR555DEHR570
DEHR620DEHR630DEHR640DEHR655DEHR670
DEHW620DEHW630DEHW640DEHW655DEHW670
2mm3mm4mm
5.5mm7mm
2mm3mm4mm
5.5mm7mm
2mm3mm4mm
5.5mm7mm
2mm3mm4mm
5.5mm7mm
Mini
Regular
Wide
68
Impression Coping
Lab Analog
Cemented Abutment LengthCuffWide
DECAW616HDECAW626HDECAW636HDECAW646H
DECAW618HDECAW628HDECAW638HDECAW648H
Code No.
DECAR516HDECAR526HDECAR536HDECAR546H
DECAR518HDECAR528HDECAR538HDECAR548H
Regular6mm
8mm
MiniDECAM416HDECAM426HDECAM436HDECAM446H
DECAM418HDECAM428HDECAM438HDECAM448H
Type
Hex 1mm2mm3mm4mm
1mm2mm3mm4mm
DECAW616NDECAW626NDECAW636NDECAW646N
DECAW618NDECAW628NDECAW638NDECAW648N
DECAR516NDECAR526NDECAR536NDECAR546N
DECAR518NDECAR528NDECAR538NDECAR548N
DECAR616HDECAR626HDECAR636HDECAR646H
DECAR618HDECAR628HDECAR638HDECAR648H
DECAR616NDECAR626NDECAR636NDECAR646N
DECAR618NDECAR628NDECAR638NDECAR648N
6mm
8mm
DECAM416NDECAM426NDECAM436NDECAM446N
DECAM418NDECAM428NDECAM438NDECAM448N
N-Hex 1mm2mm3mm4mm
1mm2mm3mm4mm
Platform Diameter Code No.DETIM40HDETIM40N
DETIR50HDETIR50NDETIR60HDETIR60N
DETIW60HDETIW60N
TransferMini
Regular
Wide
Platform Diameter Code No.DELAM
DELAR
DELAW
Mini
Regular
Wide
Cuff: 1, 2, 3, 4mm
L
H e x
H e x
N - H e x
N - H e x
Impression Coping Platform Diameter Code No.DEIM40HDEIM40N
DEIR50HDEIR50NDEIR60HDEIR60N
DEIW60HDEIW60N
Pick-Up
Pick-Up
Transfer
HexN-Hex
HexN-HexHex
N-Hex
HexN-Hex
Type
Type
HexN-Hex
HexN-HexHex
N-Hex
HexN-Hex
Mini
Regular
Wide
69Ⅳ. Components of Dentis Products |
Part 1
Cemented Abutment System
LengthCuffWide
DEAAW6215DEAAW6415
DEAAW6225DEAAW6425
Platform Diameter
DEAAR6215DEAAR6415
DEAAR6225DEAAR6425
DEAAR5215DEAAR5415
DEAAR5225DEAAR5425
Regular8mm
8mm
MiniDEAAM4215DEAAM4415
DEAAM4225DEAAM4425
Type
1 5。
2 5。
2mm4mm
2mm4mm
Angled Abutment
Plastic UCLA
Gold UCLA
Cuff: 2, 4mm
1 5。
2 5。
N - H e x
H e x
Platform DiameterTypeWide
DEGUWH
DEGUWN
RegularDEGURH
DEGURN
MiniDEGUMH
DEGUMN
Hex
N-Hex
Platform DiameterTypeWide
DEPWH
DEPWN
RegularDEPRH
DEPRN
MiniDEPMH
DEPMN
Hex
N-Hex
N - H e x
H e x
70
Healing Abutment 1.2 Hex Driver
External Fixture
Cover Screw
Healing CapEstheticone Abut.
Impression Coping(Transfer)Impression Coping(Pick-up)
Gold Cylinder Plastic Cylinder
N - H e xH e x N - H e xH e x
Lab Analog
Estheticone Driver
M o u n t
2) Estheticone Abutment System
71Ⅳ. Components of Dentis Products |
Part 1
Estheticone Abutment System
Estheticone Abutment
Platform Diameter Code No.DEEHC
DEWHC
Ø4.1
Ø5.1
Impression Coping
Healing Cap
CuffPlatform Diameter Code No.DEEA10DEEA20DEEA30DEEA40
DEWA10DEWA20DEWA30DEWA40
1mm2mm3mm4mm
1mm2mm3mm4mm
Ø4.1
Ø5.1
Type
Type
Platform Diameter Code No.DEESIHDEESIN
DEWSIHDEWSIN
HexN-Hex
HexN-Hex
Pick-Up
Pick-Up
Transfer
Transfer
Ø4.1
Ø5.1
Cuff:1, 2, 3, 4mm
Impression Coping Platform Diameter Code No.DEETI
DEWTI
Ø4.1
Ø5.1
Type
72
Gold Cylinder TypePlatform Diameter Code No.DEEGCHDEEGCN
DEWGCHDEWGCN
HexN-Hex
HexN-Hex
Ø4.1
Ø5.1
H e x
N - H e x
Lab Analog Platform Diameter Code No.DEELA
DEWLA
Ø4.1
Ø5.1
73Ⅳ. Components of Dentis Products |
Part 1
Estheticone Abutment System
Plastic Cylinder TypePlatform Diameter Code No.DEMPHDEMPN
DEWPHDEWPN
HexN-Hex
HexN-Hex
Ø4.1
Ø5.1
N - H e x
H e x
74
O-Ring AbutmentO-Ring Abutment Driver
O-Ring Lab Analog
Healing Abutment
External Fixture
Cover Screw
O - R i n g O-Ring Retainer
1.2 Hex Driver
M o u n t
3) O-Ring Abutment System
75Ⅳ. Components of Dentis Products |
Part 1
O-Ring Abutment System
O-Ring Abutment
Cuff:2, 4mm
Code No.DOLA
Code No.DOR
O-Ring Retainer
O-Ring Lab Analog
Code No.ORING
O - R i n g
CuffAbutment Diameter Code No.DEORRA20DEORRA40
DEORWA20DEORWA40
2mm4mm
2mm4mm
Ø4.1
Ø5.1
4. Dentis SAVE Submerged Implant System Flow
SAVE Submerged Fixture
76
Safe Cutting Edge / Taper Design
It has been designed for excellent osseointegration as well as excellent
initial fixation as it remarkably reduces excessive friction with the bone
due to uniform transmission of strength during insertion.
Optimum RBM Surface Treatment
Roughness measurement of the surface is Ra:
1.5-1.8um. This measurement is the most ideal
value for osseointegration.
Micro-thread for Bone Loss Prevention
Dentis Implant Micro-thread minimizes bone loss, breaking due to
internal stress and appropriate stimulus of the cortical bone together
with stable initial fixation.
Platform Switching System
Further loss of the alveolar bone is not allowed. It
reduces alveolar bone loss to the maximum in t h e
Fixture Should region using Platform Switching
P r o c e s s .
“C o n v e n i e n t”No Mount System
During surgery, existing Mount System obstructs the range of vision and
the distance between the upper and lower teeth, however Dentis No-
mount system can immediately ensure a path during surgery and
reduces operation time and attains accurate operation with no effects by
the surrounding teeth.
Convenient Compatibility of Superstructure
It is economical to use with Dentis’superstructure so there is no need
for additional SAVE Abutment System.
×5 , 0 0 0
77Ⅳ. Components of Dentis Products |
Part 1
ø5.5 SAVE Submerged Fixture Size
ø6.0 SAVE Submerged Fixture Size
C o d e
L e n g t h
ø5.5
12.0㎜
0.4㎜
ø4.8
ø5.5
10.0㎜
0.4㎜
ø4.8
ø5.5
8.0㎜
0.4㎜
ø4.8
ø5.5
7.0㎜
0.4㎜
ø4.8
ø6.0
12.0㎜
0.4㎜
ø5.3
ø6.0
10.0㎜
0.4㎜
ø5.3
ø6.0
8.0㎜
0.4㎜
ø5.3
ø6.0
7.0㎜
0.4㎜
ø5.3
DSFS5507
7mm
C o d e
L e n g t h
DSFS5508
8mm
C o d e
L e n g t h
DSFS5510
10mm
C o d e
L e n g t h
DSFS5512
12mm
C o d e
L e n g t h
DSFS6007
7mm
C o d e
L e n g t h
DSFS6008
8mm
C o d e
L e n g t h
DSFS6010
10mm
C o d e
L e n g t h
DSFS6012
12mm
SAVE Submerged Implant System Products
5. Dentis SAVE Internal Implant System Flow
SAVE Internal Fixture
78
Safe Cutting Edge / Taper Design
It has been designed for excellent osseointegration as well as excellent
initial fixation as it remarkably reduces excessive friction with the bone
due to uniform transmission of strength during insertion.
Optimum RBM Surface Treatment
Roughness measurement of the surface is
Ra: 1.5~1.8um. This measurement is the
most ideal value for osseointegration.
Micro-thread for Bone Loss Prevention
Dentis Implant Micro-thread minimizes
bone loss, breaking due to internal stress
and appropriate stimulus of the cortical
bone together with stable initial fixation.
“C o n v e n i e n t”No Mount System
During surgery, existing Mount System obstructs the range of vision and
the distance between the upper and lower teeth, however Dentis No-
mount system can immediately ensure a path during surgery and
reduces operation time and attains accurate operation with no effects by
the surrounding teeth.
×5 0
×5 , 0 0 0
79Ⅳ. Components of Dentis Products |
Part 1
ø5.5 SAVE Internal Fixture Size
ø6.0 SAVE Internal Fixture Size
ø6.0
12.0㎜
0.65㎜
ø5.3
2.0㎜
ø6.0
10.0㎜
0.65㎜
ø5.3
2.0㎜
ø6.0
8.0㎜
0.65㎜
ø5.3
2.0㎜
ø6.0
7.0㎜
0.65㎜
ø5.3
2.0㎜
C o d e
L e n g t h
DIFS5507
7mm
C o d e
L e n g t h
DIFS5508
8mm
C o d e
L e n g t h
DIFS5510
10mm
C o d e
L e n g t h
DIFS5512
12mm
C o d e
L e n g t h
DIFS6007
7mm
C o d e
L e n g t h
DIFS6008
8mm
C o d e
L e n g t h
DIFS6010
10mm
C o d e
L e n g t h
DIFS6012
12mm
ø6.0
7.0㎜
0.65㎜
2.0㎜
ø4.8
ø6.0
ø5.5ø5.5
12.0㎜
0.65㎜
2.0㎜
ø4.8
ø6.0
10.0㎜
0.65㎜
2.0㎜
ø4.8
ø6.0
8.0㎜
0.65㎜
2.0㎜
ø4.8
ø5.5
ø5.5
SAVE Internal Implant System Products
80
TypePlatform Diameter Code No.Impression Coping
Healing Abutment
Cover Screw
DIPIS60Pick-UpØ6.0(SAVE only)
CuffPlatform Diameter Code No.DIHS30DIHS40DIHS55
3mm4mm
5.5mm
Ø6.0(SAVE only)
CuffPlatform Diameter Code No.DISCS602mmØ6.0(SAVE only)
2m m
Cuff:3, 4, 5.5mm
Pick-Up
81Ⅳ. Components of Dentis Products |
Part 1
InOcta Abutment System
CuffTypePlatform Diameter Code No.DICOS10DICOS20DICOS30DICOS40
DICOS10NDICOS20NDICOS30NDICOS40N
1mm2mm3mm4mm
1mm2mm3mm4mm
Octa
N-Octa
Ø6.0(SAVE only)
InOcta Abutment
Platform Diameter Code No.DILASØ6.0(SAVE only)
Lab Analog
O c t a
6m m
Cuff:1, 2, 3, 4m m
N - O c t a
Dentis Surgical KitPart 1
Ⅴ
1. Characteristics of Surgical Tool2. Combined KIT3. SAVE KIT4. PRO KIT
84
1. Characteristics of Surgical Tool
Ⅴ. Dentis Surgical Kit
- D r i l l
3) Multi stopper drill
- Stopper Basically 2mm Rotary Stopper is fitted. Attaching and detaching is smooth and easy.When stopper makes contact with the bone, it stops rotating, hence does not damage theb o n e .
Basically Rotating Stopper is fitted. Short drill is 10mm and Long drill is 14mm. If a 4-mm stopper is fitted, the short drill can be adjustedto 8mm and the long drill to 12mm. It is convenient and possible to use without the stopper depending on the shape of the bone dur-ing surgery.
The Special Features of Safe Stopper Twist Drill 1. SAFE DRILL STOPPER
The Stopper of 3-Blade Safe Tapered Twist Drill is used to prevent nerves injury from excessive drilling.2. 3-BLADE SAFE TWIST DRILL
3-blade Safe Tapered Twist drill, produced only by DENTIS Company, has excellent cutting capability to prevent bone heating and drilling can operated at a low speed. It could easily extract bone chips and is stable for surgical operation.
3. T A P E R3-blade Safe Tapered Twist Drill, produced only by DENTIS Company, can be used at a low drilling speed to taper into the bone and gives accurate surgical operation.
1) DENTIS Multi Surgical Kit
2) Stopper drill
short Long
2㎜ 3㎜ 4㎜
Combined K I T S A V E K I T P R OK I T
8㎜
2㎜ s t o p p e r 3㎜ s t o p p e r 4㎜ s t o p p e r
7㎜6㎜
8㎜
7㎜6㎜
ø5.5-S Drill
7㎜6㎜
12㎜
2㎜ s t o p p e r 4㎜ s t o p p e r
10㎜
ø5.5-L Drill
12㎜
10㎜ 10㎜
ø2.2 12mm Twist Drill ø2.8 12mm Twist Drill ø3.5 12mm Twist Drill ø3.7 12mm Twist Drill ø4.1 12mm Twist Drill ø4.3 12mm Twist Drill ø4.8 12mm Twist Drill ø5.1 12mm Twist Drill
85Ⅴ. Dentis Surgical Kit |
Part 1
4) Excellent Enhancement of W/C Coating Treatment
Tungsten Carbide Coating is 4 times stronger and easier to drill than other drills and
minimizes bone heating during drilling.
5 )‘C o n v e n i e n t’Depth Gauge
It is easy to check the space between fixtures and the depth of Mesiodistal and the
location of buccolongual during initial drilling.
6 )‘C o n v e n i e n t’No-Mount Driver
Dentis No-mount Driver can immediately ensure a path during surgery and
reduces operation time and attains accurate operation with no effects by the sur-
rounding teeth.
7) Multiple Tap Drill
It is manufactured for Machine and Hand use, using an adaptor that can be
attached to 3 kinds of drivers(Rachet Long, Rachet Short for Machine use and
Ratchet for Hand use)
8) Torque Rachet
Convenient fittings and accurate torque value are measured in units 15NCm,
25NCm, and 35NCm. It is be managed efficiently by simply disassembling it and can
be easily cleaned inside after operation.
Comb i n ed K I TInternal / Submerged Kit
External Kit
86
87Ⅴ. Dentis Surgical Kit |
Part 1Ø3.7 Fixture Criterion
D4 Bone point drill →2.2drill →2.8drill →3.7 Fixture
D2-3 Bone point drill →2.2drill →2.8drill →3.7 Fixture drill →Ø3.7 Fixture
D1 Bone point drill →2.2drill →2.8drill →3.7 Fixture drill →3.7 Tap drill →Ø3.7 Fixture
Ø4.3 Fixture Criterion
D4 Bone point drill →2.2drill →2.8drill →3.7 Fixture drill→Ø4.3 Fixture
D2-3 Bone point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →Ø4.3 Fixture
D1 Bone point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →4.3 Tap drill →Ø4.3 Fixture
Ø4.8 Fixture Criterion
D4 Bone point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →Ø4.8 Fixture
D2-3 Bone point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →4.8 Fixture drill →Ø4.8 Fixture
D1 Bone point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →4.8 Fixture drill →4.8 Tap drill →Ø4.8 Fixture
Dentis Internal Fixture Surgical Drilling SequenceInsertion Method Depending on the Bone Condition (Drilling Sequence)
Dentis Internal Fixture Surgical Drilling SequenceInsertion Method Depending on the Bone Condition (Drilling Sequence)
Ø3.5 Fixture Criterion
D4 Bone point drill →2.2drill →2.8drill →Ø3.5 Fixture
D2-3 Bone point drill →2.2drill →2.8drill →3.5 Fixture drill →Ø3.5 Fixture
D1 Bone point drill →2.2drill →2.8drill →3.5 Fixture drill →3.5 Tap drill →Ø3.5 Fixture
Ø4.1 Fixture Criterion
D4 Bone point drill →2.2drill →2.8drill →3.5 Fixture drill →Ø4.1 Fixture
D2-3 Bone point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →Ø4.1 Fixture
D1 Bone point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →4.1 Tap drill →Ø4.1 Fixture
Ø5.1 Fixture Criterion
D4 Bone point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →Ø5.1 Fixture
D2-3 Bone point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →5.1 Fixture drill →Ø5.1 Fixture
D1 Bone point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →5.1 Fixture drill →5.1 Tap drill →Ø5.1 Fixture
I n t e r n a l / S u b m e r g e d F i x t u r e
External F i x t u r e
K I T5.5, 6.0 Fixture [Exclusive use] Surgical Kit Internal / Submerged [Multiple Use] Stopper Drill
88
D r i l l
Basically Rotating Stopper is fitted. Short drill is 8 mm and
Long drill is 12mm. If a 4-mm stopper is fitted, the short drill
can be adjusted to 6mm and the long drill to 10mm. It is con-
venient and possible to use without the stopper depending
on the shape of the bone during surgery.
S t o p p e r
Basically 2mm Rotary Stopper is fitted. Attaching and detach-
ing is smooth and easy. When stopper makes contact with the
bone, it stops rotating, hence reduce damage to the aveolar
b o n e .
No-Mount Driver
No-mount Driver can immediately ensure a path during
surgery and reduces operation time and attains accurate
operation with no effects by the surrounding teeth.
89Ⅴ. Dentis Surgical Kit |
Part 1
The Function of Path Guide during Insertion of Many FixturesDiagnosis of the Length and Size of Dental Prosthesis Simultaneously During Insertion
PROKIT, first in the world, developed for diagnosis or use in operation,
consists of a system that can be used for getting dental impression for
prosthesis during surgery, as it provides all kinds of abutments that can
be used in Internal Fixture and Internal Submerged Fixture.
It is easy to distinguish inside of the mouth or during operation due to
color coding surface treatment according to the shape and type. It is
made of titanium like the surgical superstructure which is not made of
plastic. It can also be used in all kind of dental autoclave just as other
operating tools.
Part 1
Ⅵ
1. Drilling Sequences : Internal and Submerged Type2. Drilling Sequences : External Type
S u rgical Kit and Too l
92
1. Drilling Sequences : Internal and Submerged Type
Ⅵ. Surgical Kit and Tool
93Ⅵ. Surgical Kit and Tool |
Part 1
94
95Ⅵ. Surgical Kit and Tool |
Part 1
2. Drilling Sequences : External Type
96
97Ⅵ. Surgical Kit and Tool |
Part 1
Abutment Prosthetic Pro t oc o lPart 1
Ⅶ
1. Abutment System Selection Guide2. Impression Taking : Internal Type3. Impression Taking : Submerged Type4. Impression Taking : External Type
100
1. Abutment System Selection Guide
Ⅶ. Abutment Prosthetic Protocol
● F i x t u r e ● A b u t m e n t ● Gold Cylinder
C e m e n t e d
Estheticone
Octa
InOcta
Internal Fixture
External Fixture
Cover Screw
Cover Screw
M o u n t
Healing Abutment
Octa Abutment O c t a N - O c t aGold Cylinder
O c t a N - O c t aGold UCLAAngled Abutment (15。. 25。) SynOcta Abut.InOcta Abut.Free Abutment
Healing A b u t m e n t
Angled Abutment (15。. 25。)Cemented Abutment
Estheticone Abutment
H e x N - H e xGold UCLA
H e x N - H e xGold Cylinder
Solid
Solid Abutment
4 m m 5 . 5 m m 7 m m 4 m m 5 . 5 m m 7 m m
Excellent Solid Abutment
Sub-Octa
Couple
Sole
Submerged Fixture
Cover Screw
Healing Abutment
O c t a N - O c t aGold Cylinder
Angled Abutment (15。. 25。)Couple Abutment H e x N - H e xGold UCLAFree Abutment
Sub-Octa Abutment
Sole Abutment 4 . 5 m m 5 . 5 m m 6 . 5 m m
101Ⅶ. Abutment Prosthetic Protocol |
Part 1
● Plastic Cylinde / Coping ● Impression Coping / Cap ● Lab Analog ● O - r i n g
O c t a N - O c t aPlastic Cylinder
H e x N - H e xPlastic UCLA
H e x N - H e xPlastic Cylinder
S i n g l e B r i d g ePlastic Coping
Lab Analog
Lab Analog
Lab AnalogA b u t m e n t
Lab Analog
A b u t m e n t
Lab Analog
Lab Analog
R e t a i n e r
O - R i n g
R e t a i n e r
P i c k - U p T r a n s f e rImpression Coping
P i c k - U p T r a n s f e rImpression Coping
P i c k - U p T r a n s f e rImpression Coping
P i c k - U p T r a n s f e rImpression Coping
Positioning CylinderImpression Cap Shoulder Analog & Pin Lab Analog
R e t a i n e r
A b u t m e n t
Lab Analog
O c t a N - O c t aPlastic Cylinder Lab Analog
P i c k - U p T r a n s f e rImpression Coping
P i c k - U p T r a n s f e rImpression Coping
H e x N - H e x
H e x N - H e x
H e x N - H e x Lab Analog
O c t a
N - O c t a
S i n g l e B r i d g ePlastic Coping Impression Cap Lab Analog
H e x N - H e x
H e x
N - H e x
O - R i n g
O - R i n g
102
2. Impression Taking : Internal Type
1. Removing a CoverScrew from thef i x t u r e .
2 .Combining a Solid abutment with fixture.
3 .Combining animpression cap.
4 .Equipping apositioning cylinder.
5 .Capping the trayfor impressiont a k i n g .
6 .Removing the tray( p a t t e r n ) .
7 .Equipping a Laba n a l o g .
8 .Building thesoft gingiva.
9 .Pouring stone inthe pattern.
11. Equipping a plasticcoping (or Plasticcoping work).
12. Cutting the copingfor a moderateh e i g h t .
13. Wax-up. 14. Final process forthe Crown (orB r i d g e ) . 15. Combining the Crown (or Bridge)
for the complete implant system.
10. Removing the pattern fromthe stone, and then makingthe complete working model.
Solid Abutment (indirect impression method)
- Solid (indirect impression method)Abutment level impression method of Int. - Type is applicable for every case of Cemented type prosthesis as Single unit and Multi unit.
103Ⅶ. Abutment Prosthetic Protocol |
Part 1
Solid Abutment (Direct impression method)
- Abutment level impression method of Int. - Type is applicable for every case of Cemented type prosthesis as Single unit and Multi unit.
Excellent solid Abutment (Direct impression method)
- Excellent solid required for expanding the size of abutment and crown around pre-molar and molar area's prosthesis in order to take stabilization of prosthesis.
1 . Removing a CoverScrew from thef i x t u r e .
5. Pouring stone inthe pattern.
1 . Removing a CoverScrew from thef i x t u r e .
5 .Pouring stone inthe pattern.
6 .Removing the pattern fromthe stone, and then makingthe complete working model.
7 .W a x - u p . 8 .Final process for theCrown (or Bridge). 9 .Combining the Crown (or Bridge)
for the complete implant system.
2. Combining the ExcellentSolid with implantedfixture directly.
3. Capping the tray fordirect impression.
4 .Removing the tray( p a t t e r n ) .
6. Removing the pattern fromthe stone, and then makingthe complete working model.
7. Wax-up. 8. Final process for theCrown (or Bridge).
9. Combining the Crown (or Bridge)for the complete implant system.
2 .Combining a Solidwith implantedfixture directly.
3 .Capping the tray fordirect impression.
4 .Removing the tray( p a t t e r n ) .
104
Free Abutment
- Free abutment may used as a standard abutment or an angled abutment through the milling workand adjustment of cuff height.
1 . Removing a Cover Screwfrom the fixture.
9 .Removing the pattern fromthe stone, and then makingthe complete working model.
11. Wax-up.
1 0 .M i l l i n g . 1 2 .Final process for theCrown (or Bridge).
1 3 .Combining the Crown (orBridge) for the completeimplant system.
2 .Equipping aFree Abutmentand Guide pin.
2 .E q u i p p i n ga FreeA b u t m e n t .
3 .Capping thetray for makinga pattern.
4 .Removing thetray (pattern).
5 .Combining Labanalog with FreeA b u t m e n t .
6 .Equipping thecombined Labanalog with FreeAbutment in thep a t t e r n .
7 .Building asoft gingiva.
8 .Pouring stonein the pattern.
3 .Capping theopen tray formaking ap a t t e r n .
4 .Removing theGuide pin.
5 .R e m o v i n gthe tray( p a t t e r n ) .
6 .Equipping theGuide pin on thesame position oftray (pattern).
7 .Equipping Labanalog andthen building asoft gingiva.
8 .P o u r i n gstone in thep a t t e r n .
Pick up (Open Tray)
Transfer (Close Tray)
105Ⅶ. Abutment Prosthetic Protocol |
Part 1
InOcta Abutment
- The impression work for InOcta Abutment would be done in the fixture stage and it's applicable for both- Single unit case and Multi unit case. All the prosthetic working would be processed in the Lab. - Thus, it brings reduction of the chair time. It's cemented type and it's also available for SCRP type prosthetics.
1 . Removing a Cover Screwfrom the fixture.
9. Removing the pattern fromthe stone, and then makingthe complete working model.
10. Equipping Abutmenton the working model.
11. Wax-up. 12. Final process for theCrown (or Bridge).
13. Combining the Crown (orBridge) for the completeimplant system.
2 .Equipping Pick-uptype impressionc o p i n g .
2. EquippingTransfer typei m p r e s s i o nc o p i n g .
3. Capping thetray for makinga pattern.
4. Removingthe tray( p a t t e r n ) .
5. CombiningLab analogwith Transfer.
6. Equipping Labanalog and thenbuilding a softg i n g i v a .
7. Pouringstone in thep a t t e r n .
8. Removing thepattern from thestone, and thenr e m o v i n gT r a n s f e r .
3 .Capping theopen tray formaking ap a t t e r n .
4 .Removing theGuide pin.
5 .R e m o v i n gthe tray( p a t t e r n ) .
6 .Equipping theGuide pin on thesame position oftray (pattern).
7 .Equipping Labanalog andthen building asoft gingiva.
8 .P o u r i n gstone in thep a t t e r n .
Pick up (Open Tray)
Transfer (Close Tray)
Angled Abutment
- Angled Abutment demanded for the case of bad insertion path to reward the angle, and Dentisprovides, inclined Angled Abutment.
106
1 . Removing cover screwfrom the fixture.
2 .E q u i p p i n gPick-up typeI m p r e s s i o nc o p i n g .
3. Capping the tray formaking a pattern.
4. Removing thetray (pattern).
5. CombiningLab analogwith Transfer.
6. Equipping Labanalog and thenbuilding a softg i n g i v a .
7. Pouringstone in thep a t t e r n .
8. Removing thepattern from thestone, and thenr e m o v i n gT r a n s f e r .
2. EquippingTransfer typeI m p r e s s i o nc o p i n g .
3 .Capping theopen tray formaking a pattern.
4 .Removing theguide pin.
5 .Removing thetray (pattern).
6 .Equipping theGuide pin onthe sameposition of tray( p a t t e r n ) .
7 .Equipping Labanalog andthen building asoft gingiva.
8 .P o u r i n gstone in thep a t t e r n .
9 .Combining Abutmenton the working model.
10. Wax-up.
11. Final process for theCrown (or Bridge).
12. Combining the Crown(or Bridge) for thecomplete implants y s t e m .
Pick up (Open Tray)
Transfer (Close Tray)
SynOcta Abutment
- The impression work for SynOcta Abutment would be done in the fixture stage and it's applicable for both Single unit case and Multi unit case. All the prosthetic working would be processed in the Lab.
- Thus, it brings reduction of the chair time. It's cemented type and it's also available for SCRP type prosthetics.
107Ⅶ. Abutment Prosthetic Protocol |
Part 1
1. Removing cover screwfrom the fixture.
9. Removing the pattern from thestone, and then making thecomplete working model.
10. Equipping Abutmenton the workingm o d e l .
12. Final process for theCrown (or Bridge).
11. Wax-up.
13. Combining the Crown (orBridge) for the completeimplant system.
Pick up (Open Tray)
Transfer (Close Tray)
2. EquippingPick-up typeI m p r e s s i o nc o p i n g .
3. Capping theopen tray formaking ap a t t e r n .
4. Removing theguide pin.
5. Removingthe tray( p a t t e r n ) .
6. Equipping theGuide pin on thesame position oftray (pattern).
7. Equipping Labanalog andthen building asoft gingiva.
8. Pouring stonein the pattern.
2. EquippingTransfer typeI m p r e s s i o nc o p i n g .
3. Capping the trayfor making ap a t t e r n .
4. Removingthe tray( p a t t e r n ) .
5. CombiningLab analogw i t hT r a n s f e r .
6. Equipping Labanalog and thenbuilding a softg i n g i v a .
7. Pouring stonein the pattern.
8. Removing thepattern from thestone, and thenr e m o v i n gT r a n s f e r .
Gold UCLA Abutment
- Gold UCLA Abutment is applicable for a very low occlusion case which requiresesthetics and for a screw type prosthetics.
108
1 . Removing cover screwfrom the fixture.
2. EquippingPick-up typeI m p r e s s i o nc o p i n g .
3. Capping the trayfor making ap a t t e r n .
4. Removing thetray (pattern).
5. CombiningLab analogwith Transfer.
6. Equipping Labanalog and thenbuilding a softg i n g i v a .
7. Pouringstone in thep a t t e r n .
8. Removing thepattern from thestone, and thenr e m o v i n gT r a n s f e r .
2. EquippingTransfer typeI m p r e s s i o nc o p i n g .
3. Capping the opentray for making ap a t t e r n .
4. Removingthe guidep i n .
5. Removingthe tray( p a t t e r n ) .
6. Equipping theGuide pin onthe sameposition of tray( p a t t e r n ) .
7. Equipping Labanalog andthen building asoft gingiva.
8. Pouringstone in thep a t t e r n .
9. Removing the pattern from thestone, and then making thecomplete working model.
10. Equipping GoldUCLA on theworking model.
11. Wax-up. 12. Final process for theCrown (or Bridge).
13. Combining the Crown (orBridge) for the completeimplant system.
Pick up (Open Tray)
Transfer (Close Tray)
Octa Abutment
- It's demanded to be used in Multi case of screw type with bad implant path.
109Ⅶ. Abutment Prosthetic Protocol |
Part 1
2 .Equipping OctaA b u t m e n t .
1 . Removing cover screwfrom the fixture.
3 .Equipping Pick-uptype Impressionc o p i n g .
4. Capping thetray for makinga pattern.
5. Removingthe tray( p a t t e r n ) .
6. CombiningLab analogwith Transfer.
7. Equipping Labanalog and thenbuilding a softg i n g i v a .
8. Pouringstone in thep a t t e r n .
9. Removing thepattern from thestone, and thenr e m o v i n gT r a n s f e r .
3. Equipping Transfertype Impressionc o p i n g .
4 .Capping thetray formaking ap a t t e r n .
5 .Removing theguide pin.
6 .Removing thetray (pattern).
7 .Equipping theGuide pin onthe sameposition of tray( p a t t e r n ) .
8 .Equipping Labanalog andthen building asoft gingiva.
9 .P o u r i n gstone in thep a t t e r n .
10. Removing the pattern from thestone, and then making thecomplete working model.
11. Equipping GoldC y l i n d e r .
12. Wax-up. 13. Final process for theCrown (or Bridge).
14. Combining the Crown (orBridge) for the completeimplant system.
Pick up (Open Tray)
Transfer (Close Tray)
O-ring Abutment
- O-ring Abutment is attachment-retained type prosthesis for the full denture case; the O-ringconnected with prosthesis as the connector.
110
1 . Removing cover screw from the fixture.
6 .Pouring stone in the pattern.
7 .Removing the pattern from the stone, and thenmaking the complete working model.
8 .Equipping retainer on the balls.
9 .Denture work.
10. Combining the Denture for thecomplete implant system.
2 .Equipping Ball Abutment.
3 .Capping the tray for making a pattern.
4 .Removing the tray (pattern).
5 .Equipping Lab Analog in the position.
111Ⅶ. Abutment Prosthetic Protocol |
Part 1
3. Impression Taking : Submerged Type
Sole Abutment
- Abutment level impression method of Sub - Type is applicable for every case of Cemented typeprosthesis as Single unit and Multi unit.
1 . Removing HealingA b u t m e n t .
2 .Equipping SoleA b u t m e n t .
3 .E q u i p p i n gImpression cap.
4 .Capping the tray formaking a pattern.
5 .Removing the tray( p a t t e r n ) .
6 .Equipping Lab Analogin the position.
7 .Building a soft gingiva. 8 .Pouring stone inthe pattern.
9 .Removing the pattern from thestone, and then making thecomplete working model.
10. Plastic coping work. 11. Cutting the coping fora moderate height.
12. Wax-up. 13. Final process for theCrown (or Bridge).
14. Combining the Crown (orBridge) for the completeimplant system.
Free Abutment
- Free abutment may used as a standard abutment or an angled abutment through the milling workand adjustment of cuff height.
112
1 . Removing HealingA b u t m e n t .
2 .Equipping aFree Abutmentand Guide pin.
3 .Capping theopen tray formaking a pattern.
4 .R e m o v i n gthe Guidep i n .
5 .R e m o v i n gthe tray( p a t t e r n ) .
6 .Equipping theGuide pin on thesame position oftray (pattern).
7 .Equipping Labanalog and thenbuilding a softg i n g i v a .
8 .P o u r i n gstone in thep a t t e r n .
8 .P o u r i n gstone in thep a t t e r n .
7 .Building asoft gingiva.
6 .Equipping thecombined Lab analogwith Free Abutment inthe pattern.
5 .Combining Labanalog withFree Abutment.
4 .Removing thetray (pattern).
3 .Capping thetray for makinga pattern.
2 .Equipping aF r e eA b u t m e n t .
9 .Removing the pattern from thestone, and then making thecomplete working model.
10. Milling.
12. Final process for theCrown (or Bridge).
11. Wax-up.
13. Combining the Crown (orBridge) for the completeimplant system.
Pick up (Open Tray)
Transfer (Close Tray)
Couple Abutment
- The impression work for Couple Abutment would be done in the fixture stage and it's applicablefor both Single unit case and Multi unit case. All the prosthetic working would be processed in theLab. Thus, it brings reduction of the chair time. It's cemented type and it's also available for SCRPtype prosthetics.
113Ⅶ. Abutment Prosthetic Protocol |
Part 1
1 . Removing HealingA b u t m e n t .
2. EquippingPick-up typeI m p r e s s i o nc o p i n g .
3. Capping theopen tray formaking ap a t t e r n .
4. Removing theguide pin.
5. Removingthe tray( p a t t e r n ) .
6. Equipping theGuide pin on thesame position oftray (pattern).
7. Equipping Labanalog and thenbuilding a softg i n g i v a .
8. Pouringstone in thep a t t e r n .
8. Removing thepattern from thestone, and thenremoving Transfer.
7. Pouringstone in thep a t t e r n .
6. Equipping Labanalog and thenbuilding a softg i n g i v a .
5. CombiningLab analogw i t hT r a n s f e r .
4. Removing thetray (pattern).
3. Capping thetray for makinga pattern.
2. EquippingTransfer typeI m p r e s s i o nc o p i n g .
9. Removing the pattern from thestone, and then making thecomplete working model.
10. EquippingAbutment on theworking model.
12. Final process for theCrown (or Bridge).
11. Wax-up.
13. Combining the Crown (orBridge) for the completeimplant system.
Pick up (Open Tray)
Transfer (Close Tray)
Gold UCLA Abutment
- Gold UCLA Abutment is applicable for a very low occlusion case which requires esthetics and fora screw type prosthetics.
114
1 . Removing HealingA b u t m e n t .
2. EquippingPick-up typeI m p r e s s i o nc o p i n g .
3. Capping theopen tray formaking ap a t t e r n .
4. Removing theguide pin.
5. Removingthe tray( p a t t e r n ) .
6. Equipping theGuide pin on thesame position oftray (pattern).
7. Equipping Labanalog in thepattern and thenbuilding a softg i n g i v a .
8. Pouringstone in thep a t t e r n .
8. Removing thepattern from thestone, and thenremoving Transfer.
7. Pouringstone in thep a t t e r n .
6. Equipping Labanalog and thenbuilding a softg i n g i v a .
5. CombiningLab analogwith Transfer.
4. Removing thetray (pattern).
3. Capping the tray formaking a pattern.
2. EquippingTransfer typeI m p r e s s i o nc o p i n g .
9. Removing the pattern from thestone, and then making thecomplete working model.
10. Equipping GoldUCLA on theworking model.
12. Final process for theCrown (or Bridge).
11. Wax-up.
13. Combining the Crown (orBridge) for the completeimplant system.
Pick up (Open Tray)
Transfer (Close Tray)