Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler...

12
SPRINKLER VALVE SYSTEM INSTRUCTION MANUAL p 801 295 9820 f 801 951 5815 www.fluid-studio.net 1065 South 500 West Bountiful, Utah 84010 proof no: 3 date: 09.16.09 des: SM spck: XX job no: NA client: Orbit sku: 57250 upc:NA file name: 57250-24 rB.indd software: InDesign CS3 colors additional instructions: · Font sizes cannot be smaller than 7 pt. · Translation Approval code: LB410377 · color non printing PMS ???? PMS ???? color non printing PMS ???? Registration K Printers are responsible for meeting print production requirements. Any changes must be approved by the client and Fluid Studio. printed piece must meet designated specifications on this form. dimensions: flat: w: 12" h: 8.5" finished: w 6" d: " h 8.5" © 2007 Fluid Studio. This work is the property of Fluid Studio, and cannot be used, reproduced or distributed in any way without their express permission.

Transcript of Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler...

Page 1: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

Sprinkler ValVe SyStem inStruction manual

p 801 295 9820 f 801 951 5815

www.fluid-studio.net

1065 South 500 West Bountiful, Utah 84010

proof no: 3date: 09.16.09

des: SM spck: XX

job no: NA

client: Orbit

sku: 57250

upc:NA

file name: 57250-24 rB.indd

software: InDesign CS3

colors

additional instructions:· Font sizes cannot be smaller than 7 pt. · Translation Approval code: LB410377 ·

color non printing

PMS ????

PMS ????

color non printing

PMS ????

Registration

K

Printers are responsible for meeting print production requirements. Any changes must be approved by the client and Fluid Studio. printed piece must meet designated specifications on this form.

dimensions:

flat: w: 12" h: 8.5"

finished: w 6" d: " h 8.5"

© 2007 Fluid Studio. This work is the property of Fluid Studio, and cannot be used, reproduced or distributed in any way without their express permission.

Page 2: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

important Guidelines• Warning:DONOTusepipedopeonthreads,usethreadsealtape• Placethemanifoldsothatwaterdrainsawayfromthehouse• Ifnotusingculinarywater,installafilterupstreamofthemanifold

Valve placement1. SelectalocationfortheSprinklerValveSystem

withthefollowingcriteria:• Accessibletowatersupplyline• Accessibletosprinklerwirefromtimer• Elevatedground—avoidlowareaswherewaterwillaccumulate invalvebox

2. UseanOrbit®valvebox(notincluded)toprotectthesprinklervalvesystem3. Oncealocationisselected,digaholeinthegrounddeepenoughso

thetopofthevalveboxwillbeflatandlevelwiththesurface.Tip:Orbit®recommendsplacing1"to1½"ofgravelbelowthevalveboxfordrainage

installation1. Checkeachfittingconnectionto

makesureitishand-tight.Warning:DONOTusewrenches,channellocks,orothertoolstotightenfittings

2. Checktomakesurethattheflowdirectionarrow(locatedonthebodyofthevalve)ispointedawayfromthemanifold

3. ConnectthemanifoldtoPVCmainlineusingPVCcement• For¾"PVCpipe,connect directlytoSwivelAdapter(C) (Figure 1)• For1"PVCpipe,useaCoupler (H)betweenPVCSwivelAdapter andpipe(Figure 2)• Forlargersizemainline, purchaseandinstallreducer

4. ConnectyourSprinklerValveSystemtoyoursprinklerheaderlines(sprinklerlinesdirectlyafterthevalve)• For¾"PVCpipe,connect directlytoTransitionAdapter(F) (Figure 3)• For1"PVCpipe,useCoupler (H)betweenTransitionAdapter andpipe(Figure 4)• For¾"or1"PolyPipe,use PolyAdapter(includedin 91207/91206)andsecurewith tubingclamp(Figure 5)

End Cap

1, 2, or 3 Port Manifold

PVC Swivel Adapter (connects to sprinkler mainline)

1" Swivel Adapters

1" Female Thread Valve

PVC Transition Adapter

¾" or 1" Poly Adapter (not included)

Coupler

A

A

F

E

G

F

HD

G

H

B

B

C

C

E

D

D

Page 3: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

important Guidelines• Warning:DONOTusepipedopeonthreads,usethreadsealtape• Placethemanifoldsothatwaterdrainsawayfromthehouse• Ifnotusingculinarywater,installafilterupstreamofthemanifold

Valve placement1. SelectalocationfortheSprinklerValveSystem

withthefollowingcriteria:• Accessibletowatersupplyline• Accessibletosprinklerwirefromtimer• Elevatedground—avoidlowareaswherewaterwillaccumulate invalvebox

2. UseanOrbit®valvebox(notincluded)toprotectthesprinklervalvesystem3. Oncealocationisselected,digaholeinthegrounddeepenoughso

thetopofthevalveboxwillbeflatandlevelwiththesurface.Tip:Orbit®recommendsplacing1"to1½"ofgravelbelowthevalveboxfordrainage

installation1. Checkeachfittingconnectionto

makesureitishand-tight.Warning:DONOTusewrenches,channellocks,orothertoolstotightenfittings

2. Checktomakesurethattheflowdirectionarrow(locatedonthebodyofthevalve)ispointedawayfromthemanifold

3. ConnectthemanifoldtoPVCmainlineusingPVCcement• For¾"PVCpipe,connect directlytoSwivelAdapter(C) (Figure 1)• For1"PVCpipe,useaCoupler (H)betweenPVCSwivelAdapter andpipe(Figure 2)• Forlargersizemainline, purchaseandinstallreducer

4. ConnectyourSprinklerValveSystemtoyoursprinklerheaderlines(sprinklerlinesdirectlyafterthevalve)• For¾"PVCpipe,connect directlytoTransitionAdapter(F) (Figure 3)• For1"PVCpipe,useCoupler (H)betweenTransitionAdapter andpipe(Figure 4)• For¾"or1"PolyPipe,use PolyAdapter(includedin 91207/91206)andsecurewith tubingclamp(Figure 5)

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Page 4: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

“easy Wire” connectionNote:The“EasyWire”Systemshouldonlybeusedon24-VoltsprinklertimerswithClassIIcircuits.Allwiringmustconformtoapplicablelocalcodes.1. Disconnectpowertoyoursprinkler

timer2. Runsprinklerwire(use16ga–20ga

wire)fromyourtimertothemanifoldassembly

3. Remove4"–5"oftheouterinsulationofthesprinklerwireWarning:Avoidcuttingintothewiresinside

4. Remove7/8"–1"ofinsulationfromeachindividualwire(Figure 6)

5. Insertonewirefromthevalveandacoloredwirefromthetimerintothewirenutandtwisttolockthewiresinthewirenut.Onewireshouldbeusedforeachzonewithanadditionalwiretobeusedforacommon(foreaseofidentification,usethewhitewireasthecommon).Note:Thewireshouldholdfirmwhenlightlypulled.Ifthewiremovesfreely,removethewireandrepeatStep5.(Figure 7)

6. Takethesecondwirefromeachvalveandthewhitecommonwirefromthetimerandtwistthemintothewirenut(Figure 8)

7. Inserteachwirenutintothecorrespondingcavityinsidethe“EasyWire”Organizer(Figure 9)

8. Slidethe“EasyWire”Organizerontothemountingbracketandattachtothevalvemanifold(Figure 10)

testingWarning:Beforeproceeding,makesurecementedjointshavereachedtherecommendedcuringtime(variesaccordingtomanufacturer).1. EnsuretheManualBleedScrewsonthevalvesarefullyclosed(turn

clockwiseuntilhand-tight).2. Turnonsprinklersupplylineandcheckmanifoldandvalveforleaks.If

anyleakoccurs,LIGHTLYtightenconnectionswithchannellocksuntiltheleakstops.DONOTover-tightenswivels.

3. TurnManualBleedScrewcounterclockwiseuntilwaterflowsout—runfor20secondsandturnclockwisetoretighten.Repeatwithallvalves.

4. Checkthatthesprinklertimerispluggedinand/orthecircuitbreakerison.Runeachstationmanuallyfromthetimertoverifyelectricalconnectiontothevalve.

Figure 8

Figure 9

Figure 10

Figure 6

Figure 7

Page 5: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

“easy Wire” connectionNote:The“EasyWire”Systemshouldonlybeusedon24-VoltsprinklertimerswithClassIIcircuits.Allwiringmustconformtoapplicablelocalcodes.1. Disconnectpowertoyoursprinkler

timer2. Runsprinklerwire(use16ga–20ga

wire)fromyourtimertothemanifoldassembly

3. Remove4"–5"oftheouterinsulationofthesprinklerwireWarning:Avoidcuttingintothewiresinside

4. Remove7/8"–1"ofinsulationfromeachindividualwire(Figure 6)

5. Insertonewirefromthevalveandacoloredwirefromthetimerintothewirenutandtwisttolockthewiresinthewirenut.Onewireshouldbeusedforeachzonewithanadditionalwiretobeusedforacommon(foreaseofidentification,usethewhitewireasthecommon).Note:Thewireshouldholdfirmwhenlightlypulled.Ifthewiremovesfreely,removethewireandrepeatStep5.(Figure 7)

6. Takethesecondwirefromeachvalveandthewhitecommonwirefromthetimerandtwistthemintothewirenut(Figure 8)

7. Inserteachwirenutintothecorrespondingcavityinsidethe“EasyWire”Organizer(Figure 9)

8. Slidethe“EasyWire”Organizerontothemountingbracketandattachtothevalvemanifold(Figure 10)

testingWarning:Beforeproceeding,makesurecementedjointshavereachedtherecommendedcuringtime(variesaccordingtomanufacturer).1. EnsuretheManualBleedScrewsonthevalvesarefullyclosed(turn

clockwiseuntilhand-tight).2. Turnonsprinklersupplylineandcheckmanifoldandvalveforleaks.If

anyleakoccurs,LIGHTLYtightenconnectionswithchannellocksuntiltheleakstops.DONOTover-tightenswivels.

3. TurnManualBleedScrewcounterclockwiseuntilwaterflowsout—runfor20secondsandturnclockwisetoretighten.Repeatwithallvalves.

4. Checkthatthesprinklertimerispluggedinand/orthecircuitbreakerison.Runeachstationmanuallyfromthetimertoverifyelectricalconnectiontothevalve.

Figure 8

Figure 9

Figure 10

Figure 6

Figure 7

Page 6: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

Manifold System leaks at connections

Check Solution

Connectionsareloose Retightenconnections

O-ringisoutofplace,damaged,ormissing

Replaceo-ringinproperplace

Waterpressureexceeds80PSIInstallapressureregulatorupstreamofmanifold

The valve does not open electrically (but opens using the bleed screw) and sprinkler timer is functioning

Check Solution

Individualsprinklerwirepullsouteasily

UntwistwiresandfollowStep5in“EasyWire”Connection

Bareindividualsprinklerwireextendsbeyondprotectivemembrane

Removewireandensurethebarewireisnotshorterthan7/8"andnomorethan1"inlength.UntwistwiresandfollowStep5in“EasyWire”Connection

IndividualSprinklerwiresareheldfirmlyinplacebutarenotcontactingbarewire

Ensurethebaresprinklerwireisnotshorterthan7/8"andnomorethan1"inlength.

Orbit® Irrigation Products Inc.North Salt Lake, Utah 84054 USA www.orbitonline.com1-800-488-6156PN 57250-24 rB

Solución de problemas

El sistema del tubo colector tiene fugas en las conexiones

ReviseSolución

LasconexionesestánsueltasVuelvaaapretarlasconexiones

Lajuntatóricaestádañada,enposiciónincorrectaonoestá

Pongalajuntatóricaensulugarnuevamente

Lapresióndeaguasuperalos80PSI

Instaleunreguladordepresiónaguasarribadeltubocolector

La válvula no se abre eléctricamente (pero se abre utilizando el tornillo de purga) y el temporizador del regador está funcionando

ReviseSolución

Elconductordecadaregadorsesaleconfacilidad

Separelosconductoresyprocedaconelpaso5enConexión“EasyWire”.

Losconductorespeladosindividualesdelregadorseextiendenhastamásalládelamembranaprotectora

Retireelconductoryasegúresedequeelconductorpeladotengaunalongitudmínimade2,2cmymáximade2,5cm.Separelosconductoresyprocedaconelpaso5enConexión“EasyWire”.

Losconductoresdecadaregadorestánfirmesensulugarperonotienencontactoconlosconductorespelados

Asegúresedequeelconductorpeladodelregadortengaunalongitudmínimade2,2cmymáximade2,5cm

troubleshooting

CUSTOMER SERVICE1-800-488-6156www.orbitonline.com

CUSTOMER SERVICE1-800-488-6156www.orbitonline.com

Page 7: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

Manifold System leaks at connections

Check Solution

Connectionsareloose Retightenconnections

O-ringisoutofplace,damaged,ormissing

Replaceo-ringinproperplace

Waterpressureexceeds80PSIInstallapressureregulatorupstreamofmanifold

The valve does not open electrically (but opens using the bleed screw) and sprinkler timer is functioning

Check Solution

Individualsprinklerwirepullsouteasily

UntwistwiresandfollowStep5in“EasyWire”Connection

Bareindividualsprinklerwireextendsbeyondprotectivemembrane

Removewireandensurethebarewireisnotshorterthan7/8"andnomorethan1"inlength.UntwistwiresandfollowStep5in“EasyWire”Connection

IndividualSprinklerwiresareheldfirmlyinplacebutarenotcontactingbarewire

Ensurethebaresprinklerwireisnotshorterthan7/8"andnomorethan1"inlength.

Solución de problemas

El sistema del tubo colector tiene fugas en las conexiones

ReviseSolución

LasconexionesestánsueltasVuelvaaapretarlasconexiones

Lajuntatóricaestádañada,enposiciónincorrectaonoestá

Pongalajuntatóricaensulugarnuevamente

Lapresióndeaguasuperalos80PSI

Instaleunreguladordepresiónaguasarribadeltubocolector

La válvula no se abre eléctricamente (pero se abre utilizando el tornillo de purga) y el temporizador del regador está funcionando

ReviseSolución

Elconductordecadaregadorsesaleconfacilidad

Separelosconductoresyprocedaconelpaso5enConexión“EasyWire”.

Losconductorespeladosindividualesdelregadorseextiendenhastamásalládelamembranaprotectora

Retireelconductoryasegúresedequeelconductorpeladotengaunalongitudmínimade2,2cmymáximade2,5cm.Separelosconductoresyprocedaconelpaso5enConexión“EasyWire”.

Losconductoresdecadaregadorestánfirmesensulugarperonotienencontactoconlosconductorespelados

Asegúresedequeelconductorpeladodelregadortengaunalongitudmínimade2,2cmymáximade2,5cm

Orbit® Irrigation Products Inc.

North Salt Lake, Utah 84054 USA www.orbitonline.com1-800-488-6156

CUSTOMER SERVICE1-800-488-6156www.orbitonline.com

CUSTOMER SERVICE1-800-488-6156www.orbitonline.com

Page 8: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

conexión “easy Wire”Nota:elsistema“EasyWire”sólosedebeusarentemporizadoresderegadoresde24voltiosconcircuitosClaseII.Todoelcableadodebecumplirconlasregulacioneslocalesvigentes.1.Desconecteeltemporizadorde

regadoresdelaalimentacióneléctrica.2.Paseelconductordelregador(use

conductordecalibre16a20)desdeeltemporizadorhastaelconjuntodeltubocolector.

3.Retirede10,2a12,7cmdeaislanteexternodelcabledelregador.Advertencia:tengacuidadodenocortarlosconductoresenelinterior.

4.Retirede2,2a2,5cmdeaislantedecadaconductor(Figura 6).

5.Inserteunconductordelaválvulayunconductordecolordeltemporizadorenelempalmeplásticoydóblelosparaasegurarlosenél.Sedebeusarunconductorparacadazonayelconductoradicionalseusacomoconductorcomún(paraidentificarlomásfácilmente,utiliceelconductorblancocomoelcomún).Nota:elconductordebemantenersefirmealjalarlosuavemente.Sisemueve,retíreloyrepitaelpaso5(Figura 7).

6.Junteelsegundoconductordecadaválvulaconelconductorcomúnblancodeltemporizadorydóblelosdentrodelempalmeplástico(Figura 8).

7.Insertecadaempalmeplásticoenlacavidadcorrespondientedentrodelorganizador“EasyWire”(Figura 9).

8.Desliceelorganizador“EasyWire”hacialaabrazaderademontajeyfíjeloalaválvuladeltubocolector(Figura 10).

pruebaAdvertencia:antesdecontinuar,asegúresedequelasunionesdecementohayanalcanzadoeltiempodecuradorecomendado(varíadeacuerdoconelfabricante).1.Asegúresedequelostornillosdepurgamanualdelasválvulasestén

completamentecerrados(apriételosconlamanogirandoenelsentidodelasmanecillasdelreloj).

2.Abralatuberíadesuministrodelregadoryrevisesihayfugaseneltubocolectoroenlaválvula.Sihayfugas,utiliceunalicateparafiltrosparaapretarSUAVEMENTElasconexioneshastaquelafugasedetenga.NOaprietedemasiadolasconexiones.

3.GireelTornillodepurgamanualendireccióncontrariaalasmanecillasdelrelojhastaquesalgaagua;déjelacorrerpor20segundosygíreloendireccióndelasmanecillasdelrelojparavolveraapretarlo.Repitaelprocedimientocontodaslasválvulas.

4.Verifiquequeeltemporizadordelregadorestéconectadoyqueelinterruptordecircuitoestéencendido.Activemanualmentecadaestacióndesdeeltemporizadorparacomprobarlaconexióneléctricahacialaválvula.

Figura 8

Figura 9

Figura 10

Figura 6

Figura 7

Page 9: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

conexión “easy Wire”Nota:elsistema“EasyWire”sólosedebeusarentemporizadoresderegadoresde24voltiosconcircuitosClaseII.Todoelcableadodebecumplirconlasregulacioneslocalesvigentes.1.Desconecteeltemporizadorde

regadoresdelaalimentacióneléctrica.2.Paseelconductordelregador(use

conductordecalibre16a20)desdeeltemporizadorhastaelconjuntodeltubocolector.

3.Retirede10,2a12,7cmdeaislanteexternodelcabledelregador.Advertencia:tengacuidadodenocortarlosconductoresenelinterior.

4.Retirede2,2a2,5cmdeaislantedecadaconductor(Figura 6).

5.Inserteunconductordelaválvulayunconductordecolordeltemporizadorenelempalmeplásticoydóblelosparaasegurarlosenél.Sedebeusarunconductorparacadazonayelconductoradicionalseusacomoconductorcomún(paraidentificarlomásfácilmente,utiliceelconductorblancocomoelcomún).Nota:elconductordebemantenersefirmealjalarlosuavemente.Sisemueve,retíreloyrepitaelpaso5(Figura 7).

6.Junteelsegundoconductordecadaválvulaconelconductorcomúnblancodeltemporizadorydóblelosdentrodelempalmeplástico(Figura 8).

7.Insertecadaempalmeplásticoenlacavidadcorrespondientedentrodelorganizador“EasyWire”(Figura 9).

8.Desliceelorganizador“EasyWire”hacialaabrazaderademontajeyfíjeloalaválvuladeltubocolector(Figura 10).

pruebaAdvertencia:antesdecontinuar,asegúresedequelasunionesdecementohayanalcanzadoeltiempodecuradorecomendado(varíadeacuerdoconelfabricante).1.Asegúresedequelostornillosdepurgamanualdelasválvulasestén

completamentecerrados(apriételosconlamanogirandoenelsentidodelasmanecillasdelreloj).

2.Abralatuberíadesuministrodelregadoryrevisesihayfugaseneltubocolectoroenlaválvula.Sihayfugas,utiliceunalicateparafiltrosparaapretarSUAVEMENTElasconexioneshastaquelafugasedetenga.NOaprietedemasiadolasconexiones.

3.GireelTornillodepurgamanualendireccióncontrariaalasmanecillasdelrelojhastaquesalgaagua;déjelacorrerpor20segundosygíreloendireccióndelasmanecillasdelrelojparavolveraapretarlo.Repitaelprocedimientocontodaslasválvulas.

4.Verifiquequeeltemporizadordelregadorestéconectadoyqueelinterruptordecircuitoestéencendido.Activemanualmentecadaestacióndesdeeltemporizadorparacomprobarlaconexióneléctricahacialaválvula.

Figura 8

Figura 9

Figura 10

Figura 6

Figura 7

Page 10: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

pautas importantes•Advertencia:NOuseaditivosparatubosenlasroscas;usecintaaislante.•Coloqueeltubocolectordemodoqueelaguaescurralejosdelacasa.•Sinovaautilizaraguapotable,instaleunfiltroaguasarribadeltubocolector.

colocación de la válvula1.Seleccioneunaubicaciónparaelsistemadeválvulasderegadores

conlossiguientescriterios:•Accesoalatuberíadeagua.•Accesoalcableentreelregadoryeltemporizador.•Terrenoelevado:eviteáreasbajasdondeelaguasepuedaacumularenlacajadeválvulas.

2.UseunacajadeválvulasOrbit®(noseincluye)paraprotegerelsistemadeválvulasderegadores.

3.Cuandohayaseleccionadolaubicación,caveunagujeroenlatierradeunaprofundidadsuficienteparaquecajadeválvulasquedeniveladayalrasconelterreno.Consejo:Orbit®recomiendacolocarentre2,5y4cmdegravabajolacajadeválvulasparaeldrenajedelagua.

instalación1.Asegúresedeapretarconlamanotodos

losconectores.Advertencia:NOutilicellaves,alicatesparafiltrosniotrasherramientasparaapretarlosconectores.

2.Compruebequelaflechadedireccióndelflujo(ubicadaenelcuerpodelaválvula)apuntehaciaelladoopuestoaltubocolector.

3.ConecteeltubocolectoralatuberíaprincipaldePVCconcementoPVC.•SieltubodePVCesde¾",conéctelodirectamentealAdaptadorgiratorio(C)(Figura 1).•SieltubodePVCesde1",conécteloaladaptadorgiratoriodePVCmedianteunacoplador(H)(Figura 2).•Sieltuboesmásgrande,utilicereductores(noincluidos).

4.Conecteelsistemadeválvulasderegadoresalastuberíasprincipalesdelregador(lastuberíasdelregadorqueestándirectamentedespuésdelaválvula).•SieltubodePVCesde¾",conéctelodirectamentealAdaptadordetransición(F)(Figura 3).•SieltubodePVCesde1",conécteloaladaptadordetransiciónmedianteunacoplador(H)(Figura 4).•Siesuntubodepolietilenode¾"o1",utiliceunadaptadordepolietileno(incluidoenlosmodelos91207/91206)yasegúreloconunaabrazaderaparatubería(Figura 5).

Figura 1

Figura 2

Figura 3

Figura 4

Figura 5

Page 11: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

pautas importantes•Advertencia:NOuseaditivosparatubosenlasroscas;usecintaaislante.•Coloqueeltubocolectordemodoqueelaguaescurralejosdelacasa.•Sinovaautilizaraguapotable,instaleunfiltroaguasarribadeltubocolector.

colocación de la válvula1.Seleccioneunaubicaciónparaelsistemadeválvulasderegadores

conlossiguientescriterios:•Accesoalatuberíadeagua.•Accesoalcableentreelregadoryeltemporizador.•Terrenoelevado:eviteáreasbajasdondeelaguasepuedaacumularenlacajadeválvulas.

2.UseunacajadeválvulasOrbit®(noseincluye)paraprotegerelsistemadeválvulasderegadores.

3.Cuandohayaseleccionadolaubicación,caveunagujeroenlatierradeunaprofundidadsuficienteparaquecajadeválvulasquedeniveladayalrasconelterreno.Consejo:Orbit®recomiendacolocarentre2,5y4cmdegravabajolacajadeválvulasparaeldrenajedelagua.

instalación1.Asegúresedeapretarconlamanotodos

losconectores.Advertencia:NOutilicellaves,alicatesparafiltrosniotrasherramientasparaapretarlosconectores.

2.Compruebequelaflechadedireccióndelflujo(ubicadaenelcuerpodelaválvula)apuntehaciaelladoopuestoaltubocolector.

3.ConecteeltubocolectoralatuberíaprincipaldePVCconcementoPVC.•SieltubodePVCesde¾",conéctelodirectamentealAdaptadorgiratorio(C)(Figura 1).•SieltubodePVCesde1",conécteloaladaptadorgiratoriodePVCmedianteunacoplador(H)(Figura 2).•Sieltuboesmásgrande,utilicereductores(noincluidos).

4.Conecteelsistemadeválvulasderegadoresalastuberíasprincipalesdelregador(lastuberíasdelregadorqueestándirectamentedespuésdelaválvula).•SieltubodePVCesde¾",conéctelodirectamentealAdaptadordetransición(F)(Figura 3).•SieltubodePVCesde1",conécteloaladaptadordetransiciónmedianteunacoplador(H)(Figura 4).•Siesuntubodepolietilenode¾"o1",utiliceunadaptadordepolietileno(incluidoenlosmodelos91207/91206)yasegúreloconunaabrazaderaparatubería(Figura 5).

Tapa de extremo

1Tubo colector de 1, 2 ó 3 puertos

Adaptador giratorio de PVC (se conecta a la tubería principal del regador)

Adaptadores giratorios de 1"

Válvula roscada hembra de 1"

Adaptador de transición de PVC

Adaptador de polietileno de ¾" o 1" (no se incluye)

Acoplador

A

A

F

E

G

F

HD

G

H

B

B

C

C

E

D

D

Page 12: Sprinkler ValVe SyStem inStruction manualValve placement 1. Select a location for the Sprinkler Valve System with the following criteria: • Accessible to water supply line • Accessible

SiStema de VálVulaS de reGadoreS

manual de inStruccioneS