SmartSeis ST ES-3000QuickStartManual Rev L

19
SmartSeis ST and ES-3000 Seismograph Quick Start Manual P/N 28519-03QSM Rev. L SCS Version 9.30 January 22, 2010 Geometrics, Inc. 2190 Fortune Drive San Jose, CA 95131 Tel 408-954-0522 • Fax 408-954-0902 Email: [email protected] Web: www.geometrics.com Refer to the seismograph software CD for the complete operations and reference manual and refer to the website at www.geometrics.com for the latest documentation and software releases.

Transcript of SmartSeis ST ES-3000QuickStartManual Rev L

  • SmartSeis ST and ES-3000 Seismograph Quick Start Manual

    P/N 28519-03QSM Rev. L

    SCS Version 9.30

    January 22, 2010

    Geometrics, Inc. 2190 Fortune Drive

    San Jose, CA 95131 Tel 408-954-0522 Fax 408-954-0902

    Email: [email protected] Web: www.geometrics.com

    Refer to the seismograph software CD for the complete operations and reference manual and refer to the website at www.geometrics.com for the latest documentation and software releases.

  • 10

    EC DECLARATION OF CONFORMITY January 15, 2010 We, Geometrics, Inc. and Geometrics Europe 2190 Fortune Drive San Jose, CA 95131 USA Tel: 408-954-0522 Fax: 408-954-0902 declare under our sole responsibility that our seismograph StrataVisor models NZC, NZXP 0 through NZXP 64, ES-3000, Smartseis ST, and Geode Exploration Seismograph models, to which this declaration relates, are in conformity with the following standards as these units operate from batteries under 15VDC: EN 55011: 2009, EN61000-6-2: 2005, ENV 50140: 1994, ENV 50141: 1994, EN 61000-4-2: 2009, EN 61000-4-4: 2004 per the provisions of the Electromagnetic Compatibility Directive 2004/108/EEC. The authorized representative located within the European Community is:

    Christopher Leech Geometrics Europe

    20 Eden Way Pages Industrial Park Leighton Buzzard Beds LU7 4TZ UK

    Tel: +44 (0) 1525 383438 Fax: +44 (0) 1525 382200

    __________________________ Mark Prouty, President Geometrics, Inc.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 2 of 19

  • Warning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 3 of 19

  • Copyright 2010 Geometrics, Inc.

    dhu

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 4 of 19

  • 1 Overview The SmartSeis ST and ES-3000 exploration seismographs combine simplicity of use with remarkable improvements in capability. They provide exceptional dynamic range, ruggedness, and the convenience and cost-effectiveness of PC-based control devices. The SmartSeis ST and ES-3000 are designed for refraction, borehole, and surface wave surveys, as well as for monitoring applications. They are available with a maximum of 24 channels per unit, they do not connect to other seismodules to build larger systems, and have no correlator or internal test oscillator option. Please contact us if you require other system configurations or options.

    The SmartSeis ST has the form factor of a conventional seismic recorder with integrated industrial-grade PC components, including a daylight-visible color LCD, keypad, and printer. It is internally fitted with the same seismograph components as the ES-3000.

    The ES-3000 is a highly portable (~9 lbs), stand-alone module containing only the seismograph components. It uses a fraction of the battery power of conventional

    seismographs. The ES-3000 is controlled by a PC-based computer (typically a laptop) with a 10/100 NIC, and running the appropriate version of the Windows operating system.

    The SmartSeis ST and ES-3000 are software-controlled devices which receive periodic upgrades. It is likely that the menus and operating instructions in this manual may differ in minor respects from those on your instrument. As a general rule, the menus are self-explanatory and there should be no confusion. Please refer to the website at www.geometrics.com for the latest software releases. We welcome feedback and suggestions for improvements on the instruments; please contact us at [email protected].

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 5 of 19

  • 2 SmartSeis ST and ES-3000 Quick Start Guide

    2.1 Introduction This section is for the impatient user that simply wants to plug the new seismograph system together and start experimenting. We know your type you are experienced with computers, the earth sciences, and have a busy day ahead of you. We empathize but beware. Use the Quick Start Manual only for an overview and to check out the system. Refer to the complete manual, Operation and Reference Manual for Geometrics Seismograph Models, on the enclosed CD or download a copy from the website at http://www.geometrics.com/geometrics-products/seismographs/seismograph-information-and-case-studies/ before going to the field to ensure that there are no gaps in your knowledge. We encourage you to simulate a small survey before going out to the field on a real job. Set up the geometry and acquisition parameters, collect some records, and experiment with the display settings; input sample data and try first break picking and processing. You will be glad you did.

    2.2 SmartSeis ST System Connections

    Connecting the System Together

    Connect the geophone spread cable to the 61-pin SIGNAL connector on the right-hand side. Note that you will need an adapter cable if you have a spread cable(s) with a 27-socket connector(s).

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 6 of 19

  • Connect 12V power to the 3-pin 12VDC battery connector on the back side. Make sure the battery is charged and securely connected.

    Connect the trigger cable to the 3-socket START connector on the back side.

    .Make sure that the EXT. VIDEO switch under the panel on the back side is in the OFF position. This switch allows for an external monitor to be used. If the SmartSeis ST is turned on with the switch in the ON position, the internal LCD will appear dark. To view the display on both the seismograph LCD and an external monitor, turn the seismograph on with the switch in the OFF position, then once powered-up, toggle the switch to the ON position.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 7 of 19

  • Turn on the SmartSeis ST by toggling the POWER switch on the back side.

    Once the SmartSeis ST is powered on, the Seismodule Controller Software (SCS) will automatically launch, pre- registered at the factory for the SmartSeis ST software package. The Seismodule Controller icon will be present on the desktop.

    2.3 ES-3000 System Connections

    Installing the Seismodule Controller Software SCS will need to be installed on your PC if you did not purchase it from Geometrics. The SCS installation process is typical for Windows software. Please refer to the complete manual for the full instructions.

    Connecting the System Together

    Connect the geophone spread cable to the 61-pin connector with the geophone symbol. Note that you will need an adapter cable if you have a spread cable with a 27-socket connector(s).

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 8 of 19

  • Connect the trigger cable to the 3-socket connector with the hammer symbol.

    Connect the end of the digital interface cable with a 10-pad connector to the mating connector with a data output symbol.

    Connecting the digital interfac cable may be difficult the first few times until the connectors are worn in a bit. A ign the long tab on the connector collar with the top of the connector on the ES-30in, and twist clockwise until th

    Connect the other end of the d

    network card port on the PC. Connect 12V power to the 3-p

    sure the battery is charged and The ES-3000 does not have a to a sufficiently charged batte The blue power LED next to timmediately start flashing onchas powered on. The blue LEDflash once every 3 seconds, in

    SmartSeis ST and ES-3000 Seismograph Quel00, further align the teeth in the grooves, firmly push e connector locks into place.

    igital interface cable with the RJ-45 jack to the

    in battery connector with a battery symbol. Make securely connected.

    power switch. It powers on as soon as it is connected ry.

    he power connector on the ES-3000 should e every 3 seconds, indicating that the seismograph next to the ES-3000 digital output connector will

    dicating that there is a network connection.

    ick Start Manual Rev. L Page 9 of 19

  • Turn on the PC and start SCS by double-clicking on the Seismodule Controller icon. If the PC has an LED indicator of network status, is should be lit or flashing.

    2.4 System Start-up and Survey Parameter Set-up SCS on the SmartSeis ST will have been pre-registered at the factory prior to shipment, so there will be no prompts from SCS to register the software. For the ES-3000, as SCS starts up, you will see the blue LEDs blink quickly, indicating that SCS is making a connection with the seismograph over the network. Once the connection is verified, the LEDs will change their blink rate to once every 7 seconds to conserve power, but indicate that communication is enabled with the PC. Next, you will be presented with a registration screen.

    If the PC on which SCS is to be registered is connected to the Internet, an email request for a password can be sent directly from within the registration dialog box. Otherwise, save the User Code and registration information (including the seismograph serial number) in a separate file and attach it to an email request for password to be sent to [email protected] when you have access to the Internet. Email is the preferred method for registration as characters can be misinterpreted when spoken over the telephone.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 10 of 19

  • Once your User Code is received, we will send you a registration code. Paste the registration code into the dialog box and click on Validate Registration. Press Cancel to continue using the software in unregistered mode for up to 100 hours.

    SCS includes many optional acquisition modes and operating tools. The features available as options for the SmartSeis ST and ES-3000 include continuous recording and self-triggering. During the 100-hour unregistered grace period, you can try out all the features, even if you have not purchased them. To try all options, select Try Super Seis (All Features Enabled). When you validate your registration, only the standard SCS package and options that you purchased will be enabled.

    Once past the registration stage, for both the SmartSeis ST and the ES-3000, SCS will initialize the seismograph to get it ready for use. If the network connection is not working, you will receive a message that the seismograph was not found and there will be three options to Retry making a connection the seismograph, Run Controller Without Seismographs, or Exit the Controller. Check the network cable connections and then select Retry for the PC to make another attempt to initialize the seismograph, select Run Controller Without Seismographs to continue launching the software but operate in demonstration mode, or select Exit Controller to cancel the process and close the software. Selecting Exit Controller on the SmartSeis ST will also shut down Windows XP and power off the instrument.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 11 of 19

  • If Run Controller Without Seismographs is selected, you will be presented with a message that No Acquisition Boards Were Detected; click OK to proceed with limited functionality.

    SmartSeis ST and ES-3000 Parameter Settings SCS includes a wizard that automatically presents a series of key menus that allow you to set up your recording parameters. Each of the dialog boxes included in the wizard can be accessed manually through the menu bar after the wizard runs. The wizard can also be re-run by selecting the System menu, Test, Troubleshooting: Reset All Parameters to Defaults When Program Restarts. For the SmartSeis ST, since the wizard will have already been run at the factory prior to shipment, you will need to select this menu item, close SCS, and restart SCS to see the wizard run. To close SCS and work around complete instrument shutdown, click on the X in the upper right-hand corner of the window instead of selecting

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 12 of 19

  • the System menu, Close Controller and Shutdown Windows. Please refer to the complete manual for a full explanation of the menu bar. The below explanation of the wizard assumes you are setting up for a refraction survey. The first step is to assign a Survey Name and Initial Line Number as appropriate for your site.

    Next, select Auto Stack.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 13 of 19

  • With selection of Auto Stack, other options will appear. It is recommended to leave the default settings unless you know specifically that you want to change them. Auto Save is controlled in a subsequent dialog box.

    Next, select an appropriate Sample Interval and Record Length.

    Next, accept the default off setting of Filter Out for the acquisition filters.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 14 of 19

  • Next, enter your Geophone Interval with the appropriate units.

    Next, change the default preamp gain from All Low Gain to All High Gain for signal maximum amplification.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 15 of 19

  • Next, set the Shot and Geophone Coordinates as appropriate.

    If you have an 8-, 16-, or 24-channel seismograph, click OK once the geometry is set. If you have a 12-channel seismograph, it will be necessary to make channels 13 through 16 Inactive to have the software function properly. This is easily done by moving the cursor to the Use row, Trace 13, and pressing the 4 shortcut key to Ripple the Inactive setting up to Trace 16.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 16 of 19

  • Next, set up the Storage Parameters. It is recommended that Auto Save be unchecked to allow manual stacking. After stacking the desired number of shots, manually save your data by selecting the Do Survey menu, Save.

    Next, complete the Operator Log as desired.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 17 of 19

  • Lastly, accept the default trigger parameters.

    Upon completion of the wizard, the main program window appears. For the SmartSeis ST, the default display is the Noise Monitor in maximum view (hotkey 4) as shown below. Select the Window menu, Maximize Shot Window (hotkey 5), to view shot records.

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 18 of 19

  • For the ES-3000, the default display includes the Log, Noise Monitor, and Shot windows in a cascaded view, with the Geometry Toolbar at the bottom.

    Select the Do Survey menu, Tile All Windows Vertically, to rearrange the windows so they are all visible. If you have a 12-channel ES-3000, channels 13-16 will be colored grey in the Geometry Toolbar to reflect the Inactive setting assigned previously in the geometry dialog box.

    Your seismograph system should now be operational. If you have any difficulties, please refer to the troubleshooting section of the complete manual or contact us at [email protected].

    SmartSeis ST and ES-3000 Seismograph Quick Start Manual Rev. L Page 19 of 19

    1 Overview2 SmartSeis ST and ES-3000 Quick Start Guide2.1 Introduction2.2 SmartSeis ST System ConnectionsConnecting the System Together

    2.3 ES-3000 System ConnectionsInstalling the Seismodule Controller SoftwareConnecting the System Together

    2.4 System Start-up and Survey Parameter Set-upSmartSeis ST and ES-3000 Parameter Settings