Smartpack New
-
Upload
samadomidvar6292 -
Category
Documents
-
view
88 -
download
1
description
Transcript of Smartpack New
![Page 1: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/1.jpg)
June 2006
![Page 2: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/2.jpg)
2
Eltek
Scaleable and flexible control module for the entire Eltek product range
![Page 3: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/3.jpg)
3
Eltek
Small but powerfulSmall but powerful
44mm
109 mm
144 mm
< 300g
![Page 4: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/4.jpg)
4
Eltek
”Traffic Light”LEDs
Front PanelStandardFront PanelStandard
2x16 character display
3 button Keypad
USB Port
CAN Bus IDDIP switches
![Page 5: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/5.jpg)
5
Eltek
Rear PanelCAN BusRear PanelCAN Bus
CAN bus
Part No : 242100.110(RoHS compliant)
120 ohm term. required at each end
ID based serial bus communications
Max 8 Smartpack
Max 50 Rectifiers
![Page 6: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/6.jpg)
6
Eltek
Rear PanelBattery MonitoringRear PanelBattery Monitoring
Battery Monitoring
Part No : 242100.110(RoHS compliant)
Con 4 : StandardCon 3 : Extended
• Symmetry measurement
• 8 strings mid point or2 strings 12V block
• Temp sense
![Page 7: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/7.jpg)
7
Eltek
Rear PanelInternal SystemRear PanelInternal System
Internal System
Part No : 242100.110(RoHS compliant)
System measurements
Unit Power
2xLVD control (Latched)
Battery fuse fail
![Page 8: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/8.jpg)
8
Eltek
Rear PanelAlarm I/ORear PanelAlarm I/O
Alarm I/O
Part No : 242100.110(RoHS compliant)
Con 1 (standard):-
2 + 2 relay input / output
Con 2 (extended):-
4 + 4 relay input / output
![Page 9: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/9.jpg)
9
Eltek
RS-232 OptionRS-232 Option
RS-232 mounted
Part No : 242100.111(RoHS compliant)
•Enables connection of Standalone Webpower or modem
•Rear position : Replaces extended Battery symmetry card
Part No : 242100.112(RoHS compliant)
![Page 10: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/10.jpg)
10
Eltek
1. Remove 4 chassis screws2. Remove top D-Sub fixings (CON 2 & 3).3. Lift top cover from the front.(Re-assemble in reverse order)
Opening the SmartpackOpening the Smartpack
![Page 11: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/11.jpg)
11
Eltek
Rear PanelEmbedded WebpowerRear PanelEmbedded Webpower
Embedded
WebPower
Part No : 242100.113(RoHS compliant)
Ethernet interface of remote monitoring of SmartpackIs possible to “tunnel” Powersuite remotely also.
![Page 12: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/12.jpg)
12
Eltek
FunctionalityFunctionality
Battery monitoring and testing
Temperature compensated charging
Battery lifetime indication
Alarm/event log (1000) with time and date
And much more ….
![Page 13: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/13.jpg)
13
Eltek
ScalabilityScalability
Smartpack MasterSmartpack Slave n
System functionalityVoltage input 1
Symmetry inputs 8 (2x4x12V)
Current inputs 2
Temperature inputs 2
General purpose inputs 6
Load fuse input 1
Batt fuse input 2
Relay outputs 6
Contactor control 2+
System functionalityVoltage inputs 2
Symmetry inputs 16 (4x4x12V)
Current inputs 4
Temperature inputs 4
General purpose inputs 12
Load fuse input 2
Batt fuse input 4
Relay outputs 12
Contactor control 4+
System functionality with 8 modulesVoltage inputs 8
Symmetry inputs 64 (16x4x12V)
Current inputs 2x8
Temperature inputs 2x8
General purpose inputs 6x8
Load fuse input 1x8
Batt fuse input 2x8
Relay outputs 6x8
Contactor control 2+x8
Smartpack Slave 1
CAN/Power bus
![Page 14: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/14.jpg)
14
Eltek
ConnectivityBatteryConnectivityBattery
CON3 & CON4 – Battery Connections
Temp SenseCable
Pin Function
1 Symmetry I/P 1
2 Symmetry I/P 2
3 Symmetry I/P 3
4 Symmetry I/P 4
5 Symmetry I/P 5
6 Symmetry I/P 6
7 Symmetry I/P 7
8 Symmetry I/P 8
9-10 Con 3 : Temp sense 2Con 4 : Temp sense 1
11 - 14 Con 3 – 2nd batt current, batt fuseCon 4 : Not used
![Page 15: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/15.jpg)
15
Eltek
Symmetry measurement options
ConnectivitySymmetryConnectivitySymmetry
![Page 16: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/16.jpg)
16
Eltek
ConnectivitySystemConnectivitySystem
CON5 – System ConnectionsPin Function
1 Positive Input
2 Negative Input
3 Batt Current +ve
4 Batt Current -ve
5 Batt Fuse +ve
6 Batt Fuse -ve
7 Load Fuse Fail
8 LVD1 Active
9 LVD1 Common
10 LVD2 Active
11 LVD2 CommonSystem Connection Card. Art 200625
![Page 17: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/17.jpg)
17
Eltek
ConnectivitySystemConnectivitySystem
System card configuration
JP1-48v system = 1-2 +24v system = 2-3
JP2-48v system = ‘Neg’+24v system = ‘Pos’
![Page 18: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/18.jpg)
18
Eltek
Connectivity Latched ContactorsConnectivity Latched Contactors
A latching contactor changes state only when a reversed pulse voltage is applied to the coil.
Protection Diode
![Page 19: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/19.jpg)
19
Eltek
ConnectivityExternal Alarm I/OConnectivityExternal Alarm I/O
CON1 & CON2 – I/O Connections
Pin Function
1 - 2 Alarm input 1 ( + / -)
3 – 4 Alarm input 2 ( + / -)
5 - 7 Alarm output 1 ( NO /C / NC)
8 - 10 Alarm output 2 ( NO /C / NC)
1 - 2 Alarm input 3 ( + / -)
3 - 4 Alarm input 4 ( + / -)
5 - 6 Alarm input 5 ( + / -)
7 - 8 Alarm input 6 ( + / -)
9 - 11 Alarm output 3 ( NO /C / NC)
12 - 14 Alarm output 4 ( NO /C / NC)
15 - 17 Alarm output 5 ( NO /C / NC)
18 - 20 Alarm output 6 ( NO /C / NC)Alarm Output & Input Card
Art 105954
![Page 20: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/20.jpg)
20
Eltek
Smartpack Extended Master Smartnode
CAN/Power bus Customer equipment
Convert PCOMM to Customer specific Protocol
Part no: 242100.200
Communicating with Smartpack on CAN bus
RS232 and RS485 serial interface as standard
SmartnodeSmartnode
Customer bus (RS 485)
Smartpack has only PCOMM protocol
![Page 21: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/21.jpg)
21
Eltek
PowerSuitePowerSuite
Explorer oriented easy to use PC SW
USB gives simple access.
Wide functionality with clear graphic presentation.
![Page 22: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/22.jpg)
22
Eltek
PowerSuitePowerSuite
Live Demo
![Page 23: Smartpack New](https://reader035.fdocuments.net/reader035/viewer/2022081504/55cf9c78550346d033a9f2f2/html5/thumbnails/23.jpg)
29
Eltek
End of PresentationEnd of Presentation
Let’s us know if you found this presentation useful or would like more information.
Eltek values your feedback.
Thank you