SIS Software Install Instructions Cookbook

42
SIS Software Install Instructions Cookbook Multibeam Advisory Committee March 21, 2012 SIS 3.8.3 1 beam Advisory Committee – March 21, 2012

description

SIS Software Install Instructions Cookbook. Multibeam Advisory Committee March 21, 2012 SIS 3.8.3. 1. Multibeam Advisory Committee – March 21, 2012. Contents. How to install SIS software Configure the datagram distribution software. - PowerPoint PPT Presentation

Transcript of SIS Software Install Instructions Cookbook

Page 1: SIS Software Install Instructions Cookbook

SIS Software Install InstructionsCookbook

Multibeam Advisory CommitteeMarch 21, 2012

SIS 3.8.3

1Multibeam Advisory Committee – March 21, 2012

Page 2: SIS Software Install Instructions Cookbook

Contents

• How to install SIS software• Configure the datagram distribution software

NOTE: These are directions for installing the SIS software. If you are doing this to replace a corrupt database, please see the “SIS Configuration Backup” and “SIS Software Uninstall” cookbook.

2Multibeam Advisory Committee – March 21, 2012

Page 3: SIS Software Install Instructions Cookbook

SIS Software Install

Insert the SIS software DVD. If a window does not automatically open, browse to the DVD using a file explorer and double click on the start.html file. Click on the SIS SW Installation Link.

Click Here

3Multibeam Advisory Committee – March 21, 2012

Page 4: SIS Software Install Instructions Cookbook

SIS Software Install

Once this SIS Software Installation opens up, click on the “Press here to install Seafloor Information System”.

Click Here

4Multibeam Advisory Committee – March 21, 2012

Page 5: SIS Software Install Instructions Cookbook

SIS Software Install

If a security warning pops up click run to continue the installation.

5Multibeam Advisory Committee – March 21, 2012

Page 6: SIS Software Install Instructions Cookbook

SIS Software Install

Choose your install language.

6Multibeam Advisory Committee – March 21, 2012

Page 7: SIS Software Install Instructions Cookbook

SIS Software Install

Click on the “Next” button to continue installation.

7Multibeam Advisory Committee – March 21, 2012

Page 8: SIS Software Install Instructions Cookbook

SIS Software Install

Verify that this is the version and build of SIS you want to install.

8Multibeam Advisory Committee – March 21, 2012

Page 9: SIS Software Install Instructions Cookbook

SIS Software Install

Make sure that SIS is selected as an installable component.

9Multibeam Advisory Committee – March 21, 2012

Page 10: SIS Software Install Instructions Cookbook

SIS Software Install

Choose where you want to store you raw data and where you want to store your grid data files.

10Multibeam Advisory Committee – March 21, 2012

Page 11: SIS Software Install Instructions Cookbook

SIS Software Install

Define the IP number or hostname of the Database server. If the database is going to be on the same machine you are running SIS (the normal operation mode) enter localhost.

11Multibeam Advisory Committee – March 21, 2012

Page 12: SIS Software Install Instructions Cookbook

SIS Software Install

Choose the install location for the SIS software. The default value of C:\Program Files\Kongsberg Maritime\SIS\ is the normal install location.

12Multibeam Advisory Committee – March 21, 2012

Page 13: SIS Software Install Instructions Cookbook

SIS Software Install

If you want Shortcuts to be put under the Start menu in a SIS folder simply click “Install”. Otherwise define a different folder name or click “Do not create shortcuts”.

Multibeam Advisory Committee – March 21, 2012 13

Page 14: SIS Software Install Instructions Cookbook

SIS Software Install

During the install process a dialog box will appear asking about installing a MATLAB compiler runtime, click “OK”.

Multibeam Advisory Committee – March 21, 2012 14

Page 15: SIS Software Install Instructions Cookbook

SIS Software Install

After the install is done Reboot the machine to finish the process.

Multibeam Advisory Committee – March 21, 2012 15

Page 16: SIS Software Install Instructions Cookbook

SIS Software Install

Restart SIS and reconnect with the TRU through the pulldown menu. If the TRU does not appear, Rescan, and select it.

Multibeam Advisory Committee – March 21, 2012 16

Page 17: SIS Software Install Instructions Cookbook

SIS Software Install

It is now time to import your PU settings (offsets, device settings, etc). Under the “File” menu select “Import PU parameters….”

Multibeam Advisory Committee – March 21, 2012 17

Page 18: SIS Software Install Instructions Cookbook

SIS Software Install

A dialog box will appear. Browse to the location you saved you PU parameters (normally in the E:/sisdata/common/pu_param directory. Select your saved file and click “OK”.

Multibeam Advisory Committee – March 21, 2012 18

Page 19: SIS Software Install Instructions Cookbook

SIS Software Install

Don’t worry if you see plenty of blinking red fields after doing this. Go to the “File” menu and select quit….everything will be ok.

Multibeam Advisory Committee – March 21, 2012 19

Page 20: SIS Software Install Instructions Cookbook

SIS Software Install

Start up SIS again and connect to the TRU through the pulldown menu.

Multibeam Advisory Committee – March 21, 2012 20

Page 21: SIS Software Install Instructions Cookbook

SIS Software Install

It is now time to import all of you user settings such as screen layouts, datagram subscribtions, external sensors, etc. Go the the “File” menu and select “User settings”.

Multibeam Advisory Committee – March 21, 2012 21

Page 22: SIS Software Install Instructions Cookbook

SIS Software Install

You should only load user settings from a machine with the same number of hard drives. This is not normally a problem as the usual is to load settings from the same machine. Click “Ok”.

Multibeam Advisory Committee – March 21, 2012 22

Page 23: SIS Software Install Instructions Cookbook

SIS Software Install

The “Import User Settings” dialog box will appear. Click on the file selection box for User Parameters (circled in the figure above).

Multibeam Advisory Committee – March 21, 2012 23

Page 24: SIS Software Install Instructions Cookbook

SIS Software Install

Select the User Settings parameters file. This file will end in a .params suffix.

Multibeam Advisory Committee – March 21, 2012 24

Page 25: SIS Software Install Instructions Cookbook

SIS Software Install

Click on the file selection box for “Datagram subscriptions”.

Multibeam Advisory Committee – March 21, 2012 25

Page 26: SIS Software Install Instructions Cookbook

SIS Software Install

Select the Datagram subscriptions file. This file will end in a .dgmsubs suffix.

Multibeam Advisory Committee – March 21, 2012 26

Page 27: SIS Software Install Instructions Cookbook

SIS Software Install

Click on the file selection box for “Survey templates”.

Multibeam Advisory Committee – March 21, 2012 27

Page 28: SIS Software Install Instructions Cookbook

SIS Software Install

Select the Survey template file. This file will end in a .srvtpl suffix.

Multibeam Advisory Committee – March 21, 2012 28

Page 29: SIS Software Install Instructions Cookbook

SIS Software Install

Click on the file selection box for “Projections”.

Multibeam Advisory Committee – March 21, 2012 29

Page 30: SIS Software Install Instructions Cookbook

SIS Software Install

Select the Projections file. This file will end in a .proj suffix. Make sure you DO NOT select the file that ends with a .srvtpl.proj suffix.

Multibeam Advisory Committee – March 21, 2012 30

Page 31: SIS Software Install Instructions Cookbook

SIS Software Install

Click on the file selection box for “Frame settings”.

Multibeam Advisory Committee – March 21, 2012 31

Page 32: SIS Software Install Instructions Cookbook

SIS Software Install

Select the Frames file. This file will end in a .frames suffix.

Multibeam Advisory Committee – March 21, 2012 32

Page 33: SIS Software Install Instructions Cookbook

SIS Software Install

Click on the file selection box for “External sensor settings”.

Multibeam Advisory Committee – March 21, 2012 33

Page 34: SIS Software Install Instructions Cookbook

SIS Software Install

Select the External Sensors file. This file will end in a .extsens suffix.

Multibeam Advisory Committee – March 21, 2012 34

Page 35: SIS Software Install Instructions Cookbook

SIS Software Install

Click the “Accept” button now that you have filled out all of the fields.

Multibeam Advisory Committee – March 21, 2012 35

Page 36: SIS Software Install Instructions Cookbook

SIS Software Install

Click the “Accept” button. If you are importing these settings from another sounder make sure that you change the Sounder’s serial to match the sounder you are importing for.

Multibeam Advisory Committee – March 21, 2012 36

Page 37: SIS Software Install Instructions Cookbook

SIS Software Install

Click the “Ok” button, you are done importing settings.

Multibeam Advisory Committee – March 21, 2012 37

Page 38: SIS Software Install Instructions Cookbook

SIS Software Install

Quit SIS in order to finalize the loading of the User settings.

Multibeam Advisory Committee – March 21, 2012 38

Page 39: SIS Software Install Instructions Cookbook

SIS Software Install

Start up SIS again and connect to the TRU through the pulldown menu.

Multibeam Advisory Committee – March 21, 2012 39

Page 40: SIS Software Install Instructions Cookbook

SIS Software Install

The one parameter that the above method does not correctly set (apparently) is the grid engines cell size. To fix this select “View” -> “Tear Off” -> “New Survey”.

Multibeam Advisory Committee – March 21, 2012 40

Page 41: SIS Software Install Instructions Cookbook

SIS Software Install

Change the “Number of cells in processing grid:” to 128x128 and change the “Cell size (m) to 150 for the EM122 and 5 for the EM710. It might be necessary to change to EM710’s grid cell size to 10m depending upon the size of the survey area.

Multibeam Advisory Committee – March 21, 2012 41

Page 42: SIS Software Install Instructions Cookbook

Datagram Distribution Configuration

SIS as part of the install process wiped out the datagram distribution parameters. Open the software and add a source port of 4310 for Centerbeam Depth and a the desired IP and destination port (for the Kilo Moana’s EM120 you should enter 192.168.1.40:5634 and for the EM710 you should enter 192.168.50:5635).

Multibeam Advisory Committee – March 21, 2012 42

R/V Kilo Moana’s EM122 Data Distribution settings.

R/V Kilo Moana’s EM710 Data Distribution settings.