Simplicity is the real innovation -...
-
Upload
nguyencong -
Category
Documents
-
view
219 -
download
3
Transcript of Simplicity is the real innovation -...
Simplicity is the real innovation
EN_Mise en page 1 09.12.10 10:20 Page1
Have you ever been frustrated by the
complexity of certain things?
•
EN_Mise en page 1 09.12.10 10:20 Page2
• Only one NiTi instrument per root canal in most cases• Optimal cutting efficiency*• Decreases the global shaping time by up to 40%• Saves time and increases comfort• Simplicity, safety and efficiency
*Compared to leading brands
EN_Mise en page 1 09.12.10 10:20 Page3
Have you ever been worried by the fragility
of certain things?
•
EN_Mise en page 1 09.12.10 10:20 Page4
• Reduced risk of a screwing effect and file breakage*• Flexibility and greater resistance to cyclic fatigue, the leading cause of file separation• Respects the root canal anatomy
*Compared to leading brands
EN_Mise en page 1 09.12.10 10:20 Page5
Have you ever been horrifiedby the lack of cleanliness
of certain things?
EN_Mise en page 1 09.12.10 10:21 Page6
• Single use as new standard of care• No risk for cross contamination• No need for disinfecting, cleaning, sterilizing and organizing the wave•oneTM NiTi files
EN_Mise en page 1 09.12.10 10:21 Page7
Simplicity is the real innovation
EN_Mise en page 1 09.12.10 10:21 Page8
EN_Mise en page 1 09.12.10 10:21 Page9
EN_Mise en page 1 09.12.10 10:21 Page10
When endodontics becomes synonymous with simplicitywave•oneTM, from Dentsply Maillefer, sets new standards in endodontics according to
dentists, by bringing simplicity, safety and efficiency to the root canal shaping procedure,
using only one NiTi instrument per root canal in most cases.
The complexity of endodontic procedures may discourage many practitioners from
performing this type of treatment. However, wave•oneTM introduces the concept of
simplicity in endodontics, in order to save time and increase comfort, whilst still
offering a technique that provides premium quality root canal treatments.
Single file technique with reciprocating motion
The wave•oneTM motor works in reciprocating mode, which means that it continuously
changes its rotating direction during the shaping procedure. Using a large rotating
angle in the cutting direction provides high efficiency and using a smaller angle in the
reverse direction helps the wave•oneTM file to successively progress along the canal
path, whilst respecting the root canal anatomy. The optimized angles also reduce the
risk of a screwing effect and file breakage.* wave•oneTM reciprocation therefore
increases the practitioner’s confidence as well as the patient’s safety.
The advantages of the reciprocating technique are numerous. First of all, it makes it
possible to shape most root canals using only one single wave•oneTM Nickel-Titanium
file. This means that no time is wasted changing NiTi instruments during the root canal
shaping procedure. This brings optimal simplicity to the practitioner and decreases the
global shaping time by up to 40% versus a traditional rotary technique in continuous motion.
Reciprocating
wave•oneTM
70
60
50
40
30
20
10
0
Cutting efficiency shaping time (s)
Standard NiTicontinuous rotation
–40%
*Compared to leading brands
offering a tec
Single file
The wave•on
changes its
angle in the
reverse direc
Reciprocating
EN_Mise en page 1 09.12.10 10:21 Page11
M-WireTM
Dentsply utilizes an innovative thermal treatment process to create the M-Wire™ NiTi
material. Its resulting characteristics provide overall flexibility and greater resistance
to cyclic fatigue, the leading cause of file separation. In fact, the tougher the instru-
menting challenge, like shaping severely curved canals to the apex, the more appa-
rent the M-Wire™ NiTi’s advantages become.
EN_Mise en page 1 09.12.10 10:21 Page12
When endodontics becomes synonymous with comfort
The wave•oneTM fileThe wave•oneTM file has a geometry that was conceived specifically in order to bring
a maximum of user benefits from the reciprocating movement of the wave•oneTM
motor. This geometry, combined with the proprietary Dentsply M-Wire™ Nickel-Titanium
technology are the main reasons for the superior performance of the wave•oneTM file
compared to most NiTi files on the market today.
When endodonticsbecomes synonymous with single use
Dentsply Maillefer advocates a new standard of care, by proposing the wave•oneTM
reciprocating NiTi files exclusively in pre-sterilized blister packs and fitted with a non
autoclavable handle.
When single use becomes affordableMost dental practitioners are seeking ways to reduce operating costs in their practice.
Using one single wave•oneTM rotary file for each shaping procedure, instead of four to
five, finally makes it affordable to implement a single use policy for endodontic instru-
ments. The wave•oneTM files are supplied in a pre-sterilized blister pack and cannot
be sterilized for a second patient treatment.
Increased comfortThe wave•oneTM features potentially make the
dentist feel more at ease with the endodontic
procedure than before. The reciprocating tech-
nique therefore represents an important turning
point in the endodontic field.
wave•oneTM shaping techniqueThe primary wave•oneTM file is designed to fully shape the majority of all root canals.
However, if a K-File 10 is very resistant to movement then the appropriate size is small. If
a K-File 20 easily goes to length then the appropriate wave•oneTM file size is large.
Usually one single wave•oneTM file will be enough to fully shape the root canal.
Standard NiTicontinuous rotation
Fatigue resistance time until breakage (s)
200
180
160
140
120
100
80
60
40
20
0wave•oneTM
+130%
EN_Mise en page 1 09.12.10 10:21 Page13
Why single patient use of endodontic files makes sense
SimplicityThere is no need for disinfecting, cleaning, sterilizing and organizing the wave•oneTM
NiTi files.
No risk for cross contaminationNo matter how well an instrument is sterilized, research shows that certain bacteria and tissue remnants may remain on the instrument. Therefore, any re-use of these instruments increases the potential for cross-infection for the next patient.
Optimal cutting efficiency *Further research has shown that using endodontic files in multiple cases actually reduces their cutting efficiency. Ultimately, this reduces operating efficiency in a dental practice and affects the satisfaction of both the dentist and the patient. With wave•oneTM there is no reduction in cutting efficiency, as a new instrument is used for each patient.
These photographs clearly illustrate the differences in the condition of a Nickel Titanium rotary file before use, after one use and after three uses. The file was used according to manufacturer’s directions in extracted teeth: multi-rooted molars with moderate curvature. (SEMs – 200x magnification, 6/06)
Better control of file breakageEndodontic files exhibit signs of wear during normal use. They are also subject to cyclic fatigue, the main cause of file breakage. This will gradually alter the physical properties of the file, which potentially can lead to file breakage during patient treat-ment. Single use therefore gives better control of file breakage and thus increased patient safety.
Before use After one use After three uses
*Compared to leading brands
EN_Mise en page 1 09.12.10 10:21 Page14
Optimised settings in reciprocationThe wave•oneTM motor is pre-programmed with settings for the wave•oneTM reciproca-ting file system. The fixed speed and angle parameters have been minutely optimised and are the results of extensive testing by the most prominent endo specialists in the world.
Continuous rotationThe wave•oneTM motor is also pre-programmed with our continuous rotation file systems ProTaper® Universal, PathFileTM, ProFile®, GT® Series X as well as the Gates files. Additionally, there are 15 free programs for individual settings in continuous rotation.
ObturationOne file – one paper pointwave•oneTM paper points match the size of the canals prepared with a wave•oneTM file and are ideal for a safe and rapid drying process of the canals. Their sterile conditio-ning increases your chances for endodontic success.
• 3 sizes fit all canals prepared with wave•oneTM files• Easily recognizable: identical color coding for files and paper points• Packaged in individual sterile cell packs of 5 points• Their wider taper design allows you to use less paper points to dry your canals, when compared with ISO conventional points
One file – one gutta pointwave•oneTM gutta percha points match the size of the canals prepared with wave•oneTM files, letting you achieve rapid and precise master-cone obturation.
• 3 sizes fit all canals prepared with wave•oneTM files• Easily recognizable: identical color coding for files and gutta percha points
One file – one obturatorwave•oneTM obturators match perfectly the size of the canals prepared with wave•oneTM files, letting you achieve rapid and precise warm 3D filling.
• One file – one obturator - Easily recognizable: identical color coding for files and obturators - Optimal fit in wave•oneTM prepared canals
• Heated gutta percha combined with the central carrier ensures excellent filling of the apex and lateral canals - Also recommended for long, narrow, curved canals - Minimal risk of root fracture
thermaprep® 2 oven for wave•oneTM
• The obturator is ready in less than one minute
- The oven heats up the wave•oneTM obturators in 20 to 49 seconds depending on the size of the obturator - A built-in timer audibly signals when the filling material reaches its optimal temperature
• The obturator is kept at the right temperature for 90 seconds
wave•oneTM endo motor
EN_Mise en page 1 09.12.10 10:21 Page15
0459Tech
nica
l mod
ifica
tions
on
our
pro
duc
ts a
re n
ot s
ubje
ct t
o no
tific
atio
ns.
Pho
tos
of
our
inst
rum
ents
are
not
con
trac
tual
0459 Dentsply Mai l lefer • Chemin du Verger 3 • CH-1338 Bal la igues • Switzer land • www.dentsplymai l lefer.com
EN_Mise en page 1 09.12.10 10:21 Page16
wave•oneTM reciprocating files
wave•oneTM paper points
wave•oneTM obturators
wave•oneTM endo motor
•oneTM reciprocating files
wave•oneTM gutta percha points
bt t
thermaprep® 2 oven for wave•oneTM
aper poi t
wave•oneTM endo motor
thermaprep® 2 oven for wave•oneTM
print rabat_Mise en page 1 09.12.10 10:25 Page1
REF A 0700 2210 0 S01- 3x small (021 .06) - 21mm + DFU
REF A 0700 2250 0 S01- 3x small (021 .06) - 25mm + DFU
REF A 0700 2310 0 S01- 3x small (021 .06) - 31mm + DFU
wave•oneTM small reciprocating file
REF A 1700 000 10S 00 - 6x small obturatorsREF A 1700 000 11S 00 - 20x small obturators
wave•oneTM small obturators
REF A 1700 000 10P 00 - 6x primary obturatorsREF A 1700 000 11P 00 - 20x primary obturators
wave•oneTM primary obturators
REF A 1700 000 10L 00 - 6x large obturatorsREF A 1700 000 11L 00 - 20x large obturators
wave•oneTM large obturators
REF A 0700 2210 0 P01- 3x primary (025 .08) - 21mm + DFU
REF A 0700 2250 0 P01- 3x primary (025 .08) - 25mm + DFU
REF A 0700 2310 0 P01- 3x primary (025 .08) - 31mm + DFU
wave•oneTM primary reciprocating file
REF A 0700 2210 0 L01 - 3x large (040 .08) - 21mm + DFU
REF A 0700 2250 0 L01 - 3x large (040 .08) - 25mm + DFU
REF A 0700 2310 0 L01 - 3x large (040 .08) - 31mm + DFU
wave•oneTM large reciprocating file
REF A 0700 2219 0A01 assorted - 21mm1x small (021 .06) + 1x primary (025 .08) +1x large (040 .08)+DFU
REF A 0700 2259 0A01 assorted - 25mm1x small (021 .06) + 1x primary (025 .08) + 1x large (040 .08)+DFU
REF A 0700 2319 0A01 assorted - 31mm1x small (021 .06) + 1x primary (025 .08) + 1x large (040 .08)+DFU
wave•oneTM assortment reciprocating file
REF A 024W 000 00S 01 - 180x sterile paper points smallwave•oneTM paper points small
REF A 024W 000 00P 01 - 180x sterile paper points primarywave•oneTM paper points primary
REF A 024W 000 00L 01 - 180x sterile paper points largewave•oneTM paper points large
REF A 024W 000 900 01 - 60x sterile paper points small60x sterile paper points primary - 60x sterile paper points large
wave•oneTM paper points assortment
REF A 024X 000 00S 00 - 60x gutta percha small
REF A 024X 000 00P 00 - 60x gutta percha primarywave•oneTM gutta percha points primary
REF A 024X 000 00L 00 - 60x gutta percha largewave•oneTM gutta percha points large
REF A 024X 000 900 00 - 20x gutta percha small20x gutta percha primary - 20x gutta percha large
wave•oneTM gutta percha points assortment
Reciprocating files
Paper points
Gutta percha points
Obturators
wave•oneTM endo motorREF A 1018 including wave•oneTM contra-angle 6:1
REF A 1019 wave•oneTM contra-angle 6:1
Oven
wave•oneTM gutta percha points small
REF A 0176 2300 0200 - EU (230V)
REF A 0176 2300 0233 - UK (230V)
REF A 0176 1150 0200 - (115V)
Endo motor
wave•oneTM starter kit 1
REF A 1021 100 000 00
wave•oneTM starter kit 2
REF A 1021 200 000 00
Starter kits
thermaprep® 2 oven for wave•oneTM
wR
R
E
print rabat_Mise en page 1 09.12.10 10:25 Page2