SICAM A8000 Engineering - assets.new.siemens.com · SICAM A8000 Engineering Reinhard Krug, Head of...

22
SICAM A8000 Engineering Reinhard Krug, Head of SICAM A8000 Product Lifecycle Management September 12-13, 2019 | VAR Partner Day 2019 | Bled, Slovenia siemens.at/var Unrestricted © Siemens AG 2019

Transcript of SICAM A8000 Engineering - assets.new.siemens.com · SICAM A8000 Engineering Reinhard Krug, Head of...

SICAM A8000 EngineeringReinhard Krug, Head of SICAM A8000 Product Lifecycle ManagementSeptember 12-13, 2019 | VAR Partner Day 2019 | Bled, Slovenia

siemens.at/varUnrestricted © Siemens AG 2019

Unrestricted © Siemens AG 201912-13 SEP 2019Page 2 Reinhard Krug / SI DG SA&P

SICAM WEB:Parameterization made easy – online tool for SICAM A8000

• Easy online configuration• Reliable and secure remote maintenance

via https• Cleartext diagnostics• Event and alarm lists• Supports simulation and testing

Convenient functions

• Plug & play functionality• Simple and intuitive user interface• Multi-lingual support• Universal use on tablets and desktop PCs• Operable on all standard browsers• Optimized for small bandwidth

Technical highlights• Access to all parameters 24/7• One-time assignment

of address• No limitation of applicability• Maximized user friendliness

Advantages

Unrestricted © Siemens AG 201912-13 SEP 2019Page 3 Reinhard Krug / SI DG SA&P

SICAM Device ManagerThe intuitive engineering tool for SICAM A8000

Duplication of devices

• Simple, clear management of projects and devices in folder structures

• Little time and effort needed for parameterization thanks to duplication of devices and automatic adjustment of specific parameters

• Full compatibility between SICAM WEB and Device Manager

• Look-and-feel correspond to SICAM WEB

• Up- and download of device configuration

Customer benefits

Online connection with devicevia SICAM WEB

Project and device management

Automatization functions via integrated CFC editor

• CP-8000• CP-8021• CP-8022• CP-8050

Offline parameterization

Unrestricted © Siemens AG 201912-13 SEP 2019Page 4 Reinhard Krug / SI DG SA&P

SICAM Device ManagerTrailer with new functions

(Link to Video)

Unrestricted © Siemens AG 201912-13 SEP 2019Page 5 Reinhard Krug / SI DG SA&P

SICAM Device ManagerProjekt and Device Management

Unrestricted © Siemens AG 201912-13 SEP 2019Page 6 Reinhard Krug / SI DG SA&P

SICAM Device ManagerCopy device

Unrestricted © Siemens AG 201912-13 SEP 2019Page 7 Reinhard Krug / SI DG SA&P

SICAM Device ManagerFirmware Loader (Multiple firmwares & devices)

Unrestricted © Siemens AG 201912-13 SEP 2019Page 8 Reinhard Krug / SI DG SA&P

SICAM Device ManagerV3.0: CP-8050 Dash Board

Unrestricted © Siemens AG 201912-13 SEP 2019Page 9 Reinhard Krug / SI DG SA&P

SICAM Device ManagerV3.0: CP-8050 configuration

Unrestricted © Siemens AG 201912-13 SEP 2019Page 10 Reinhard Krug / SI DG SA&P

SICAM Device ManagerV3.0: CP-8050 Hardware

Unrestricted © Siemens AG 201912-13 SEP 2019Page 13 Reinhard Krug / SI DG SA&P

SICAM Device ManagerLogic Editor CFC

Unrestricted © Siemens AG 201912-13 SEP 2019Page 14 Reinhard Krug / SI DG SA&P

SICAM Device Manager Logic Editor CFC

CFC offline test

CFC online monitoring

CFC user defined FBs

CFC user defined Structures

FBs acc. to IEC 61131

Usability: ANY-Module (ab v3.0), etc.

Unrestricted © Siemens AG 201912-13 SEP 2019Page 15 Reinhard Krug / SI DG SA&P

IEC 61850 System Configurator –ONE tool for all IED Configuration tools (ICTs)

ReyDisp

DIGSI 5DIGSI 4

SICAMDevice Manager

3rd PartyICTs

SICAMTOOLBOX II

Unrestricted © Siemens AG 201912-13 SEP 2019Page 16 Reinhard Krug / SI DG SA&P

IED communication engineeringdirectly up to Control Center

2 data flows to define Simplified SCL engineering up to Control Center with: (NEW) IEC 61850-80-1 for IEC 60870-5-104

addresses between RTU and Control Center (implicit dynamic) MMS Reporting from IED to RTU

Only 1 SCD Import in SICAM RTUs: via SICAM ToolBox II V6.x or SICAM Device Manager

IEC 61850

SICAM RTU(e.g., AK3 or A8000)

Control Center

Station bus

ProtectionIED

BayBCUIED

IEC 61850-80-1 / IEC 60870-5-104

Unrestricted © Siemens AG 201912-13 SEP 2019Page 19 Reinhard Krug / SI DG SA&P

SICAM Device ManagerIEC 61850 Client Engineering

Unrestricted © Siemens AG 201912-13 SEP 2019Page 29 Reinhard Krug / SI DG SA&P

SICAM Device ManagerOnline function available via SICAM WEB

Unrestricted © Siemens AG 201912-13 SEP 2019Page 30 Reinhard Krug / SI DG SA&P

SICAM WEB CP-8050

Unrestricted © Siemens AG 201912-13 SEP 2019Page 31 Reinhard Krug / SI DG SA&P

SICAM WEB Monitoring of I/O Signals

Unrestricted © Siemens AG 201912-13 SEP 2019Page 33 Reinhard Krug / SI DG SA&P

SICAM WEB Protocol-specific information - IEC 61850

Unrestricted © Siemens AG 201912-13 SEP 2019Page 34 Reinhard Krug / SI DG SA&P

SICAM Device ManagerV3.0: Summary

Engineering CP-8000 / 21 / 22 and CP-8050

CFC Function CP-8000 / 21 / 22 and CP-8050

IEC 61850 Client

SICAM A8000 Online access via SICAM WEB

SICAM A8000 configuration: RTU via IEC104 to SCADA SA-Gateway IEC61850 auf IEC104

V3.0 @ SIOS

Unrestricted © Siemens AG 201912-13 SEP 2019Page 36 Reinhard Krug / SI DG SA&P

SICAM Device ManagerLicense Concept

6MF7800-1FB00 - SICAM Device Manager BasicThe intuitive engineering tool for SICAM A8000

6MF7800-1FS00 - SICAM Device Manager StandardThe intuitive engineering tool for SICAM A8000 plus CFC

6MF7800-1GS00 - SICAM Device Manager Upgrade Basic to Standard

Unrestricted © Siemens AG 201912-13 SEP 2019Page 37 Reinhard Krug / SI DG SA&P

Contact

Reinhard KrugSiemens Smart Infrastructure / Digital GridHead of Product Lifecycle Management (SICAM A8000)

SI DG SA&P PR AT-PLM

Siemensstraße 901210 Wien, Austria

Mobile: +43 (0) 664 80117 31275

E-mail:[email protected]

siemens.com/energy-automation-products