SFC 065 R2 14SFRR - Zeva Creator1) symbol indicates a non-standard application. Inquire with...

10
3 Cooling Tower Drives SFC Series SFC Series Size Gear Stages Lubrication Shaft Arrangement Accessories Nominal Ratio Output Torque (kNm) R2 S P : Splash : Shaft Driven Pump RR 6.3 7.1 8 9 10 11.2 12.5 14 16 18 045 (10.0) 055 (18.0) 060 (21.7) 065 (27.5) 070 (35.5) 075 (44.0) SFC 065 R2 14 RR S F Right Angle Double Reduction F FB N NB : With Cooling Fan : With Cooling Fan & Backstop : No Additional Cooling : With Backstop (Standard) (Standard) SFC Series is designed to CTI standard specifications. Item Gear Bearing Shaft Housing Seal Gearbox External Conditions Lubrication Standard Specification Type : Roller Bearing Rated Life (L10) : Low Speed Shaft Bearing High Speed Shaft / Intermediate Shaft Bearings .......................... 100,000 Hours or Longer .... 50,000 Hours or Longer Material Spec : Alloy Steel Heat Treatment : Case Hardening Processing : Precision Finish Material Spec : Alloy Steel Material Spec : Cast Iron P4 Reference High Speed Shaft input speed : 450~1800r/min Housing and Cover Mating surfaces : Liquid Sealant Low Speed Shaft : Dust-lip Oil Seal and Seal Hood High Speed Shaft : Dust-lip Oil Seal Oil Splash Lubrication An oil splasher attached to the high speed shaft propels oil from the lower oil resevoir to the upper bearing oil resevoir. Paint Rotation Speed Outside Temperature Environment Altitude Not designed for corrosive or explosive gas environments. Designed for altitudes of 1000m or less. 0˚C~40˚C Temperatures outside the -15˚C~40˚C range requires the use of synthetic oil. Consideration of the ambient temperature and temperature near the gearbox must be taken.

Transcript of SFC 065 R2 14SFRR - Zeva Creator1) symbol indicates a non-standard application. Inquire with...

3 Cooling Tower Drives SFC Series

SFC

Series Size Gear Stages Lubrication Shaft

Arrangement Accessories NominalRatio

Output Torque(kNm)

R2 S

P

: Splash

: Shaft Driven Pump

RR

6.37.1 8 91011.212.5141618

045 (10.0)

055 (18.0)

060 (21.7)

065 (27.5)

070 (35.5)

075 (44.0)

SFC 065 R2 14RRS F

Right Angle

DoubleReduction

F

FB

N

NB

: With Cooling Fan

: With Cooling Fan & Backstop

: No Additional Cooling

: With Backstop

(Standard)

(Standard)

SFC Series is designed to CTI standard specifications.

Item

Gear

Bearing

Shaft

Housing

Seal

Gearbox

ExternalConditions

Lubrication

Standard Specification

Type : Roller BearingRated Life (L10) : Low Speed Shaft Bearing

High Speed Shaft / Intermediate Shaft Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . 100,000 Hours or Longer

. . . . 50,000 Hours or Longer

Material Spec : Alloy SteelHeat Treatment : Case Hardening Processing : Precision Finish

Material Spec : Alloy Steel

Material Spec : Cast Iron

P4 Reference

High Speed Shaft input speed : 450~1800r/min

Housing and Cover Mating surfaces : Liquid SealantLow Speed Shaft : Dust-lip Oil Seal and Seal HoodHigh Speed Shaft : Dust-lip Oil Seal

Oil Splash LubricationAn oil splasher attached to the high speed shaft propels oil from the lower oil resevoir to theupper bearing oil resevoir.

Paint

Rotation Speed

Outside Temperature

Environment

Altitude

Not designed for corrosive or explosive gas environments.

Designed for altitudes of 1000m or less.

0˚C~40˚CTemperatures outside the -15˚C~40˚C range requires the use of synthetic oil.Consideration of the ambient temperature and temperature near the gearbox must be taken.

Cooling Tower Drives SFC Series 4

Mineral Oil

Synthetic Oil

Brand ARAL BP CASTROL CHEVRON GULF SHELLOPTIMOL TEXACO TRIBOLTOTALFINA ELF

DEGOL ENERGOL ALPHA GEARCOMPOUNS

SPARTAN MOBIL- EP LUBRI- OMALA MEROPA CARTER TRIBOLISO VG320AGMA 6EP BG320 GR-XP-320 SP320 EP320 EP320 GEAR 632 CANT HD320 320

OPTIGEARBM 320 WM 320 EP320 1100/320

EXXONMOBIL

MOBIL GEARSHC XMP

320

MOBIL GEARSHC 320

ISO VG320AGMA 6S

EXXONMOBILBrand

* One layer of modified alkyd resin paint as the first primer

Denatured epoxy

UnderCoating

UnderCoating

FinishCoating

UnderCoating

FinishCoating

FinishCoating

Vinyl denatured epoxy paint

Vinyl denatured epoxy paint

Denatured alkyde resin

StandardPaint

StandardPaint

Polymide epoxy resin

Polymide epoxy resin

High build, modified aluminumexpoxy paint

High build, modified aluminumexpoxy paint

Heavy DutyCorrosion ResistantPaint 1(Option)

Heavy DutyCorrosion ResistantPaint 2(Option)

Thick film epoxy

InsidePaint

OutsidePaint *

20~40

30~60

WaterResis-tance

AcidResis-tance

AlkaliResis-tance

HeatResis-tance

Weather-bility offinished

coat

20~40

CorrosionResistance

HumidityResistance

OilResistance

HumidityResistance

&Weatherability

120~240

40~80

Kind of painting

Valuation basis : . . .Excellent, . . .Good

Classification

Polyurethane SecondCoating 120~240

40~80

20~40 Polyisocyanate type urethane resin paint

Thickness m

Paintingarea Classification

Paint of finish coat Type Quality

Paint Specification

5 Cooling Tower Drives SFC Series

Fan Speedr/min

✽✽

✽✽

✽ ✽ ✽ ✽

✽ ✽ ✽ ✽

Input Shaft Speed 1750r/min

Input Shaft Speed 1160r/min

Mot

or (k

W)

Mot

or (k

W)

Mot

or (k

W)

Mot

or (k

W)

ReductionRatio

Fan Speedr/min

ReductionRatio

Fan Speedr/min

ReductionRatio

Fan Speedr/min

ReductionRatio

1) ✽ symbol indicates a non-standard application. Inquire with Sumitomo for details2) For more specific details please use the following selection method.

Attention

Input Shaft Speed 1450r/min

Input Shaft Speed 970r/min

Determine theService Factor (SF)

Determine theReducer Size

Thrust Load

Determine Reduction Ratio

Item

Input ShaftRotating Speed

Ambient Temperature

Selection Order

1) Thrust load is the downward thrust load due to the weight and rotation of the cooling fan in the clockwise direction.2) Allowable thrust load is based on a bearing life of 100,000 hours. Please inquire about cases above the 100,000 hour limit.3) Please inquire about operating abient temperature that exceed the 0~40˚C range.4) Please inquire about input shaft operating speeds lower the 450 r/min or higher then 1800 r/min.

Attention

SF = 2.0

Actual Thrust Load < Allowable Thrust Load on Slow Speed ShaftConservatively calculated, Actual Thrust Load = Fan Thrust Load + Fan Weight

Motor Power < Mechanical Rating (Service Factor 2.0)

Selection Method

Standard Input Shaft operating range 450~1800r/min

Standard ambient temperature operating range 0~40˚C

Reduction Ratio = Motor Speed ÷ Fan Speed

=

=

Reference Page

P.6 Rating Table

P.6 Allowable Thrust Load on Slow Speed Shaft

Required SpecificationsCooling Tower132kW × 1500r/min107 r/min14.7kNClockwise rotation0~40˚CYes

Use :Motor Power :Cooling Fan Speed :Actual Thrust Load :Rotation Direction :Ambient Temperature :Backstop :

Selection ExampleSelection

1. Determine Reduction Ratio

2. Determine the Service Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . SF=2.03. Determine the Size

4. Check Thrust Load

5. Check Ambient Temperature

6. Check Input Shaft Operating Range

7. With Backstop

Motor Speed/Fan Speed = 14

Transfer Capacity (Motor Rating) < Mechanical [email protected] Rating Table SFC065R2S-14 Ratio 14132<160kW (Mechanical [email protected]) . . . . . . . . . . . . . . . . . . O K

Low Speed Shaft Allowable Thrust Load14.7kN<28kN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O K

Operating Ambient Temperature 0~40˚C. . . . . . . . . . . . . . . . . . . . O K

Based on the selection criteria above, SFC065R2S-RRFB-14 is selected

1500r/min Fixed Speed is within the 450~1800r/min operating limits . . . O K

=

55

75

90

110

132

160

250

280

200

16 18

055 060

110 97

10 11.2 12.5 14

045 045

045 045 045 055 055 055

045 055 055 055 055 055

055 055 055 055

055 055 055 060 065 065

175 155 140 125

055 060 060 065 070 070

060 065 065 070 075 075

065 070 070 075

070 075 075

075

8 9

045045

045 045

045 055

055 055

220 195

055 055

6.3 7.1

045

045

045

280 245

060

✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽

✽✽✽

16 18

070 070

73 64

8 9 10 11.2 12.5 14

055045 055 055055 055

055055045 055 055 055 055 060

055 055 055 055 060 060 065 070

055 055 055 060 065 065

060 060 060 065 065 070 075

075

075

145 130 115 105 93 83

060 065 065 065 070 070

070 075 075 075

075 075

6.3 7.1

045

045045045

060 060

185 165

060 060

075

065 065 065 065

065 070 070 075

55

75

90

110

132

160

200

250

280

16 18

91 81

8 9 10 11.2 12.5 14

55 045045 045

75

90

110

132

180 160 145 130 115 105

160

200

250

6.3 7.1

045

230 205

280

065 065

045045045 055 055 055 055 055

045 045 055 055 055 055 055 060

055 055 055 055 055 060

045

045

055 055 055 060 060 065 070 070

060 060 060 065 065 065 075 075

065 065 070 070 075 075

070 075 075 075

070 075 075

060 065

065 065

070

16 18

075 075

61 54

8 9 10 11.2 12.5 14

55 055045 055 055055 055

75 055055055 055 055 060 065 065

90 055 055 055 060 060 065 070 070

110 060 060 060 065 065 070

132 060 065 065 065 070 075 075

120 110 97 87 78 69

160 065 065 070 070 075 075

200 075 075 075

250

6.3 7.1

045045045

060 060

060 060

155 135

065 065

280

065 065 070 075

Cooling Tower Drives SFC Series 6

Attention1) When the desired input speed is not shown, use interpolation to determine the appropriate values.2) When input speed (N) is below 970 r/min, use the following formula to determine the mechanical power rating (PN)3) Please inquire with us when input shaft speed exceeds 1800r/min.4) ※Please inquire with us about these categories.5) – No information available.

PN = P970 × N970

Unit : kW

NominalRatio

Input Speed Output Speed

Exact Ratio

Exact Ratio

Exact Ratio

Exact Ratio

Exact Ratio

Exact Ratio

Exact Ratio

Exact Ratio

Exact Ratio

Exact Ratio

Size

r/min r/min 045 055 060 065 070 075

6.3

6.188 6.426 6.188 –––––––––––––––

1750 2801450 2301160 185 191 241 260970 155 155 201 225

7.1

7.320 7.210 6.927 6.9331750 245 1151450 205 991160 165 77 189 241 260970 135 64 154 201 225

8

8.338 7.955 7.875 8.118 8.0821750 220 115 1671450 180 99 136 227 2641160 145 77 112 188 213 286970 120 64 91 152 178 231

9

8.889 8.938 9.176 8.750 9.056 8.5971750 195 105 167 2231450 160 91 136 180 251 287 3241160 130 70 112 150 203 230 264970 110 59 91 122 164 193 221

10

10.125 10.125 9.995 10.028 10.125 10.0071750 175 95 171 211 2571450 145 79 144 176 223 2851160 115 64 115 140 179 229 280970 97 55 96 117 145 186 234

11.2

11.624 11.375 11.647 10.809 11.345 11.2291750 155 78 142 171 235 2841450 130 65 119 143 204 230 3041160 105 52 96 115 164 192 252970 87 43 80 96 133 160 205

12.5

13.240 12.462 12.469 12.756 12.797 12.5361750 140 75 138 161 202 257 3401450 115 61 115 135 163 208 2911160 93 49 94 105 135 167 234970 78 41 77 90 113 139 201

14

14.000 14.529 13.750 14.338 14.0671750 125 116 138 193 233 3011450 105 97 115 161 201 2521160 83 78 95 125 162 202970 69 66 77 105 131 164

16

15.188 15.392 15.889 15.750 15.8441750 110 113 131 151 188 2571450 91 94 106 122 151 2081160 73 75 85 97 122 167970 61 61 71 82 101 139

18

17.062 17.936 17.500 17.647 17.7791750 97 96 112 133 185 2321450 81 80 94 111 150 2011160 64 65 75 89 120 156970 54 55 63 77 101 131

kW

※※※※※

※※※

※※

※※

※※

※※

※※

※※

※ ※ ※

※ ※ ※

※ ※※

※※※※※※※

※※※※※※※※※※※※※※※

Unit : kN

Output Shaft Speed Size (r/min) 060055045 065 070 075<<<

300 16 25 22 28 29 50150 18 27 27 28 31 50100 21 29 30 34 39 50

===

7 Cooling Tower Drives SFC Series

Input Shaft Speed 1750r/min

Input Shaft Speed 1160r/min

Input Shaft Speed 1450r/min

Input Shaft Speed 970r/min

16 18

110 97

8 9 10 11.2 12.5 14

75

100

125

150

175

220 195 175 155 140 125

200

250

300

6.3 7.1

280 245

350

ReductionRatio

Mot

or (H

P)

r/minFan Speed

055 060

045 045

045045045 045 045 055 055 055

045 045 045 055 055 055 055 055

045 055 055 055 055 055

055 055 055 055 055 060 060 065

055 055 055 060 060 065 065 070

060 065 065 065 070 075

065 065 070 070

045

045

045

070 075 075

075

060

075

✽✽

✽✽

✽✽

✽✽✽✽✽

✽✽

✽✽

1) ✽ symbol indicates a non-standard application. Inquire with Sumitomo for details2) For more specific details please use the following selection method.

Attention

ReductionRatio

Mot

or (H

P)

r/minFan Speed

8

75

100 045

125 055

150 055

175 060

145

200 060

250

300

6.3 7.1

045

045045

060 060

185 165

060 060

350

060 060 065

065 070 070

070

9 10

045

055055

055 055

055 055

060 060

130 115

060 065

070

070

045

075

065

070

075

11.2 12.5 14

055 055 055

055 055 055

055 055 060

060 065 065

065 065 070

105 93 83

065 070 070

070 075 075

075 075

16 18

070 070

73 64

055 055

055 060

065 070

075

075

075

075

75

100

125

150

175

200

250

300

6.3 7.1

045

045

230 205

350

ReductionRatio

Mot

or (H

P)

r/minFan Speed

8 9 10 11.2

045045

045045045 055

045 055 055 055

055 055 055 055

055 055 055 060

180 160 145 130

060 060 060 065

065 065

070 070

045

070 075

060 065

060 065

065 070

16 18

065 070

91 81

12.5 14

045

055 055 055 055

055 055 055 060

055 060

060 065 070 070

115 105

065 065 070 070

070 070 075 075

075 075

075

✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽ ✽

✽ ✽

✽ ✽

✽ ✽

✽ ✽

✽ ✽

✽ ✽

✽ ✽

✽ ✽✽✽ ✽

✽ ✽

✽ ✽

✽ ✽

✽ ✽ ✽ ✽

16 18

61 54

8 9 10 11.2 12.5 14

75

100

125

150

175

120 110 97 87 78 69

200

250

300

6.3 7.1

155 135

350

ReductionRatio

Mot

or (H

P)

r/minFan Speed

055055

060 060

060 060

060 065

060 065

045045045

060 060

060 060

060 060

065 065 070 070

070 070 070

075 075

055055 055 055055 060

055 055 055 060 065 065

055 060 065 065 070 070

060 065 065 070

065 065 070 070 075

070 070 075 075

075 075 075

075

075

Selection Order

Selection Example

Use :Motor Power :Cooling Fan Speed :Actual Thrust Load :Rotation Direction :Ambient Temperature :Backstop :

SelectionRequired SpecificationsCooling Tower200HP × 1750r/min107 r/min14.7kNClockwise rotation0~40˚CYes

1. Determine Reduction Ratio

2. Determine the Service Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SF=2.0 3. Determine the Size

4. Check Thrust Load

5. Check Ambient Temperature

6. Check Input Shaft Operating Range

7. With Backstop

Motor Speed/Fan Speed = 16

Transfer Capacity (Motor Rating) < Mechanical [email protected] Rating Table SFC065R2S-16 Ratio 16200<202HP (Mechanical [email protected]) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OK

Low Speed Shaft Allowable Thrust Load14.7kN < 28kN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OK

Operating Ambient Temperature 0~40˚C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OK

Based on the selection criteria above, SFC065R2S-RRFB-16 is selected

1750r/min Fixed Speed is within the 450~1800r/min operating limits . . . . . OK

=

Selection Method

Determine theService Factor (SF)

Determine theReducer Size

Thrust Load

Determine Reduction Ratio

Item

Input ShaftRotating Speed

Ambient Temperature

Reference Page

P.8 Rating Table

P.8 Allowable Thrust Load on Slow Speed Shaft

SF = 2.0

Actual Thrust Load < Allowable Thrust Load on Slow Speed Shaft

Conservatively calculated, Actual Thrust Load = Fan Thrust Load + Fan Weight

Standard Input Shaft operating range 450~1800r/min

Standard ambient temperature operating range 0~40˚C

Reduction Ratio = Motor Speed ÷ Fan Speed

Motor Power < Mechanical Rating (Service Factor 2.0)=

=

1) Thrust load is the downward thrust load due to the weight and rotation of the cooling fan in the clockwise direction.2) Allowable thrust load is based on a bearing life of 100,000 hours. Please inquire about cases above the 100,000 hour limit.3) Please inquire about operating abient temperature that exceed the 0~40˚C range.4) Please inquire about input shaft operating speeds lower the 450 r/min or higher then 1800 r/min.

Attention

Cooling Tower Drives SFC Series 8

Attention1) When the desired input speed is not shown, use interpolation to determine the appropriate values.2) When input speed (N) is below 970 r/min, use the following formula to determine the mechanical power rating (PN)3) Please inquire with us when input shaft speed exceeds 1800r/min.4) ※ Please inquire with us about these categories.5) – No information available.

Unit : kN

PN = P970 × N970

HP

Size

45 55 060 065 07516 25 22 28 29 5018 27 27 28 31 5021 29 30 34 39 50

Output Shaft Speed (r/min)

NominalRatio

Input Speed Output Speedr/min r/min 060 065 070

Size

6.3

7.1

8

9

11.2

12.5

14

16

18

1750 2801450 2301160 185970 155

Exact Ratio

1750 2451450 2051160 165970 135

Exact Ratio

1750 2201450 1801160 145970 120

Exact Ratio

1750 1951450 1601160 130970 110

Exact Ratio

1750 1751450 1451160 115970 97

Exact Ratio

1750 1551450 1301160 105970 87

Exact Ratio

1750 1401450 1151160 93970 78

Exact Ratio

1750 1251450 1051160 83970 69

Exact Ratio

1750 1101450 911160 73970 61

Exact Ratio

1750 971450 811160 64970 54

Exact Ratio

152 176 202 252 345126 142 164 202 279101 114 130 164 22482 95 110 135 186

129 150 178 248 311107 126 149 201 27087 101 119 161 20974 84 103 135 176

17.062 17.936 17.500 17.647 17.779

15.188 15.392 15.889 15.750 15.844

156 185 259 312 404130 154 216 270 338105 127 168 217 27189 103 141 176 220

101 185 216 271 345 45682 154 181 219 279 39066 126 141 181 224 31455 103 121 152 186 270

13.240 12.462 12.469 12.756 12.797 12.536

105 190 229 315 38187 160 192 274 308 40870 129 154 220 257 33858 107 129 178 215 275

11.624 11.375 11.647 10.809 11.345 11.229

14.000 14.529 13.750 14.338 14.067

127 229 283 345106 193 236 299 38286 154 188 240 307 37574 129 157 194 249 314

10.125 10.125 9.995 10.028 10.125 10.007

141 224 299122 182 241 337 385 43494 150 201 272 308 35479 122 164 220 259 296

8.889 8.938 9.176 8.750 9.056 8.597

154 224133 182103 15086 122

304 354252 286 384204 239 310

8.338 7.955 7.875 8.118 8.082

154133103 25386 207

323 349270 302

256 323 349208 270 302

6.188 6.426 6.188

7.320 7.210 6.927 6.933

045 055 075–––––––––––––––

10

Unit : HP

300150100

0 0 070<=<=<=

※※※※※

※※※

※※

※※

※※

※※

※※

※※

※ ※ ※

※ ※ ※

※ ※※

※※※※※※※

※※※※※※※※※※※※※※※

Cooling Tower Drives SFC Series 10

Low Speed Shaft

W1

V1

X1

Z1

Y1

W2

High Speed Shaft

X2

Z2

Y2

S

Oil Level

4- J

(DP2)Oil Drain/Fill

(DP1)Oil Fill

Magnetic Plug

(DP1)Air Vent

Oil Gauge Cooling Fan

B A

L2

P

L1U

L

K2

H

N2

K1

OL

5

N1

MM

GG

E1

M M

E1

G D D G

DD

FCCK1

(1) Keys and keyways for both high speed and low speed shafts conform to ISO/R773-1969 close key. (JIS B 1301-1996 Parallel Key in Fastening Type)(2) The oil quantity shown is approximate. Fill to the appropriate level using the oil level gauge.(3) Air breather and air breather pipe are assembled by the customer and installed on site. A pipe extending from the gearbox to outside the fan stack should be prepared. Piping parts are not included.(4) The installation bolts should be rated JIS Class 8.8 .(5) To maintain coupling alignment, stop plates or knock pins should be installed to prevent gearbox twisting on its base due to fan operation.

Attention

Units : mm

Size A B DC E1 G H L P M Weight(kg)

Oil Q'ty(Liters)

OL

045 725 262 645 200 470 35 38 28 (M24) 725 290 95 365 24 260

055 794 301 714 225 530 40 40 35 (M30) 795 320 105 435 34 290

060 865 318 750 240 560 40 45 35 (M30) 900 370 105 660 52 335

065 946 338 831 260 600 40 45 35 (M30) 990 395 105 830 55 360

070 965 363 850 275 650 50 52 42 (M36) 1010 415 135 960 75 375

075 1018 383 903 295 690 50 52 42 (M36) 1045 450 135 1250 95 410

J (Installation Bolt)

V1 U1 L1 X1 Y1 Z1 W1/Depth W2/ DepthS FC L2 X2 Y2 Z2 DP1 K1 K2 DP2 N1 N2

045 100m6 210 190 28 10 16 M24/50 45k6 80 80 14 5.5 9 M16/36 R 1 190 393 R 1 1/4 235 80

055 110m6 210 190 28 10 16 M24/50 50k6 80 80 14 5.5 9 M16/36 R 1 210 445 R 1 1/4 265 100

060 120m6 210 185 32 11 18 M24/50 60m6 115 105 18 7 11 M20/42 R 1 1/4 260 505 R 1 1/4 280 105

065 130m6 250 225 32 11 18 M24/50 65m6 115 105 18 7 11 M20/42 R 1 1/4 280 555 R 1 1/4 300 105

070 140m6 250 225 36 12 20 M30/60 65m6 115 105 18 7 11 M20/42 R 1 1/4 290 575 R 1 1/4 325 105

075 150m6 250 225 36 12 20 M30/60 65m6 115 105 18 7 11 M20/42 R 1 1/4 310 610 R 1 1/4 345 105

Pipe ThreadHigh Speed ShaftLow Speed ShaftSize

10

12. Construction drawing

4101

41243602

4103 41104121

6004 7609

3604

65096009

462260103603600365026002

6001 25013601 41227404

4110 6010

6509 41246009

36036003 410360236002

3601 6001 2501

4101 6502 4121

6004 3602 7609

3604 4622

7404 4122

Option

Option

1 1/4

POS.NO Part Name2501 Slow speed shaft3601 Helical gear3602 Helical pinion shaft3603 Bevel gear3604 Bevel pinion shaft4101 Key4103 Key4110 Key4121 Key4122 Key4124 Key4622 Tolerance ring6001 Tapered roller bearing6002 Tapered roller bearing6003 Tapered roller bearing6004 Tapered roller bearing6009 Tapered roller bearing6010 Spherical roller bearing6502 Oil seal6509 Oil seal7404 Backstop7609 O-ring

Part NameSlow speed shaftHelical gearHelical pinion shaftBevel gearBevel pinion shaftKeyKeyKeyKeyKeyKeyTolerance ringTapered roller bearingTapered roller bearingSpherical roller bearingSpherical roller bearingTapered roller bearingSpherical roller bearing

Oil sealOil sealBackstopO-ring

POS.NO2501360136023603360441014103411041214122412446226001600260036004600960106023 Thrust cylindrical roller bearing6502650974047609

Fig.6 SFC045・SFC055

Fig.7 SFC060・SFC065・SFC070・SFC075

11

Drain plug

Oil gauge Cooling fan

Magnetic plug

Air vent

Oil filler

Lifting eye nut

Fig9. Locations of oil filler and drain plug

13. Locations of oil filler and drain plug