Ministry of Environment, Energy and Climate ChangeMouzakis George, Dipl. Chem. Engineer
GR-147 Patission Str. 112 51 ATHENS - GREECE Tel: +30 210 8629928, Fax: +30 210 8662968
E mail: [email protected]
SEVESO REGISTRY IN GREECE
Establishments under the provisions of Seveso Dir. in Greece/1The current situation of the establishments
under the provisions of the Seveso Directive in Greece is the following:85 upper tier establishments (safety report,
internal and external emergency plans, information to the public, annual inspection)
132 lower tier establishments (notification study, major accident prevention policy, annual inspection)
Establishments under the provisions of Seveso Dir. in Greece/2
DANGEROUS SUBSTANCE LOWER TIER UPPER TIER
Liquid petroleum products 48 % 21 %
LPG, NLG 28 % 28 %
Oil refineries - 5 %
Fertilizers - 1 %
Explosives 7 % 20 %
Chemicals 16 % 7 %
Pesticides 1 % 18 %
TOTAL NUMBER 132 85
Web Site of the Hellenic Ministry of Environment
Access to Risk Management Issues focused mainly to the implementation of Seveso Directive in Greece through the web site of the Hellenic Ministry of Environment www.ypeka.gr Existing legislation in European Union and GreeceGuidelines for the application of dispensation rule of article 9 par. 6Guidance for the preparation of a Safety ReportGuidelines for the content of information to the publicGuidelines for the carriage of dangerous goodsLand use planning guidelinesGuidelines on a Major Accident Prevention Policy and Safety
Management SystemGuidance on InspectionsQuestionnaire – Check list useful for the inspectionsUseful links
www.e-per.grWeb Site of the National Center for the
Environmental Information.Data of the upper and lower tier Seveso
establishments in Greece on Geographical Information System.
Data of the upper and lower tier Seveso establishments in Greece on several applications (multiple sheets)
Front page of www.e-per.gr
Username and password of the site
Introduction to the system
Upper and Lower tier establishments/1
Upper and Lower tier establishments/2
Upper and Lower tier establishments/3
Database of the establishments
Database of the establishments/ identification/a
Database of the establishments/ identification/b
Database of the establishments / dangerous substances
Database of the establishments / Seveso compliance
Database of the establishments / external emergency plans
Database of the establishments / information to the public
Database of the establishments / inspections
Database of the establishments / evaluation of the Safety Report/a
Database of the establishments / evaluation of the Safety Report/b
External Emergency Plans – 3 zones for protection / 1
External Emergency Plans – 3 zones for protection / 2
Toxic substancesConcentration
(mg/m3)
Thermal dose units(TDU)
Blast overpressure
(mbar)
Zone 1Inner zone
LC501500
(15 kw/m2 exposure for 40
sec)
350
Zone 2Middle zone LC1
450
(6 kw/m2 exposure for 40
sec)
140
Zone 3Outer zone IDLH
170
(3 kw/m2 exposure for 40
sec)
50
Criteria for the Domino effectType of accident Criteria for
Domino
ThermalRadiation
BLEVE Fireball radius
Thermalradiation
JET FIRE The length of the jet for t>1000 s
Thermalradiation
POOLFIRE 37.5 kw/m2
Overpressure UVCE 700 mbar
External Emergency Plans – 3 zones for protection / case study
What should do the licensing authorities for the full implementation of Seveso Directive
Check of the completeness of the Safety Reports and the notification studies
Evaluate all the Safety Reports and the notification studiesRegistration of all the evaluated Safety ReportsDrawing up of the external emergency plans for all the
upper tier Seveso establishments (Civil Protection services)Public information for all the upper tier Seveso
establishments (Civil Protection services) At least one inspection per year of every upper and lower
tier Seveso establishmentCONTINUOUS UPDATE OF THE DATA BASE www.e-per.gr
What should do Seveso establishments for the full implementation of Seveso DirectiveThe operator is obliged to take all measures necessary
to prevent major accidents and to limit their consequences for man and the environment
The operator is required to prove to the Authorities at any time, that he has taken all the measures necessary as specified in this Directive.
Compile and submit to the Authorities notification or/and safety studies
Update all above mentioned StudiesSupports Authorities for the drawing up of the external
emergency plan of the establishmentCONTINUOUS UPDATE OF THE DATA BASE