5/1Siemens NS PS · 2001
5SENTRON SeriesCircuit-Breakers
Selection and ordering dataUL/NEMA SENTRON Series Circuit-Breakers 5/2CQD and QJ version, 1-, 2- and 3-pole, up to 225 A 5/23-pole, up to 2000 A 5/4Accessories3-pole, up to 2000 A 5/6Description 5/8Technical data 5/9Characteristic curves 5/10Dimensions 5/12
titel_05.fm Seite 1 Donnerstag, 15. Februar 2001 7:41 07
Selection and ordering data
Versiontype
Overloadrelease
Short-circuitrelease
1-pole 2-pole 3-pole Dimensionsmm
In = Ir
A
I i
A
Switching capacity65 kA at AC 120 VRelease calibration 40 °C
Order No. Price
Switching capacity 14 kA at AC 277/480 VRelease calibration 40 °C
Order No. Order No. Price
WeightApprox. (kg)
Circuit-breakers suitable for worksites and industry
with fixed-setting overload/short-circuit releases
CQD100 A
15 20 25
850 8501100
CQD115CQD120CQD125
CQD215CQD220CQD225
CQD315CQD320CQD325
2-poleL = 124W = 51D = 73
(0.45)
3-poleL = 124W = 76D = 73
(0.68)
30 35 40
110013001300
CQD130CQD135CQD140
CQD230CQD235CQD240
CQD330CQD335CQD340
45 50 60
130014001400
CQD145CQD150CQD160
CQD245CQD250CQD260
CQD345CQD350CQD360
70 80 90100
1400140014001400
CQD170CQD180CQD190CQD1100
CQD270CQD280CQD290CQD2100
CQD370CQD380CQD390CQD3100
Switching capacity 10 kA at AC 240 V
QJ2225 A
60 70 80 90
600 600 800 800
Not available QJ22 @ 060 QJ22 @ 070 QJ22 @ 080 QJ22 @ 090
QJ23 @ 060 QJ23 @ 070 QJ23 @ 080 QJ23 @ 090
2-poleL = 178W = 76D = 64(1.41)
3-poleL = 178W = 114D = 73(1.45)
100110125150
900 90015001800
QJ22 @ 100 QJ22 @ 110 QJ22 @ 125 QJ22 @ 150
QJ23 @ 100 QJ23 @ 110 QJ23 @ 125 QJ23 @ 150
175200225
265026502650
QJ22 @ 175 QJ22 @ 200 QJ22 @ 225
QJ23 @ 175 QJ23 @ 200 QJ23 @ 225
Switching capacity 22 kA at AC 240 V
QJH2225 A
60 70 80 90
600 600 800 800
Not available QJH22 @ 060 QJH22 @ 070 QJH22 @ 080 QJH22 @ 090
QJH23 @ 060 QJH23 @ 070 QJH23 @ 080 QJH23 @ 090
2-poleL = 178W = 76D = 64(1.41)
3-poleL = 178W = 114D = 64(1.45)
100110125150
900 90015001800
QJH22 @ 100 QJH22 @ 110 QJH22 @ 125 QJH22 @ 150
QJH23 @ 100 QJH23 @ 110 QJH23 @ 125 QJH23 @ 150
175200225
265026502650
QJH22 @ 175 QJH22 @ 200 QJH22 @ 225
QJH23 @ 175 QJH23 @ 200 QJH23 @ 225
Release calibration
z z
40 °C50 °C
BM
BM
/>>
CQD Version QJ Version
UL/NEMA Sentron Series Circuit-BreakersCQD and QJ Version, 1-, 2- and 3-pole, up to 225 A
S. 5/2 C S. 5/2 Y
5/2 Siemens NS PS ⋅ 2001
Accessories
For versions
CQD
External mounting on the left side
Order No.
QJ
Only factory-mounted
Order No.
Opening coil
CQDST120 CQDST240 CQDST277 CQDST480 CQDST600
CQDST12 CQDST24 CQDST48 CQDST125
S01QJ0R3 S01QJ0R3 Not availableNot availableNot available
Not availableS07QJ0R3 S09QJ0R3 S10QJ0R3
Minimum voltage coil
CQDUV120 CQDUV240 CQDUV277 CQDUV480 Not available
CQDUV24 CQDST48 Not available
Not available
Auxiliary co ntact1 inverter2 inverters
Not available CQDA2
A01QJ0R3A02QJ0R3
Alarm contact1 inverter
CQDBA Not available
AC V DC V
120240–480600
––––
–––––
12 24 48125
AC V DC V
120240277480600
–––
–––––
12 48125
S. 5/3 C S. 5/3 Y
UL/NEMA Sentron Series Circuit-BreakersCQD and QJ Version, 1-, 2- and 3-pole, up to 225 A
5
Siemens NS PS ⋅ 2001 5/3
Selection and ordering data
Versiontype
OverloadreleaseIn = Ir
Short-circuitreleaseI i
Dimensions mm
A A
Switching capacity18 kA at AC 480 V
Order No. Price
High switching capacity42 kA at AC 480 V
Order No. Price
Extra-high switching capacity65 kA at AC 480 V
Order No. Price
WeightApprox.
(kg)
with fixed-setting overload and short-circuit releases
ED125 A
15 20 25
600 600 600
ED43 @ 015 ED43 @ 020 ED43 @ 025
HED43 @ 015 HED43 @ 020 HED43 @ 025
HHED63 @ 015 HHED63 @ 020 HHED63 @ 025
ED4, HED6L = 161W = 76D = 102(1.8) 30
35 40
600 600 600
ED43 @ 030 ED43 @ 035 ED43 @ 040
HED43 @ 030 HED43 @ 035 HED43 @ 040
HHED63 @ 030 HHED63 @ 035 HHED63 @ 040
45 50 60
600 6001000
ED43 @ 045 ED43 @ 050 ED43 @ 060
HED43 @ 045 HED43 @ 050 HED43 @ 060
HHED63 @ 045 HHED63 @ 050 HHED63 @ 060
70 80 90100
1000100010001000
ED43 @ 070 ED43 @ 080 ED43 @ 090 ED43 @ 100
HED43 @ 070 HED43 @ 080 HED43 @ 090 HED43 @ 100
HHED63 @ 070 HHED63 @ 080 HHED63 @ 090 HHED63 @ 100
HHED6L = 166W = 76D = 102(1.8)
110125
10001000
ED43 @ 110 ED43 @ 125
HED43 @ 110 HED43 @ 125
HHED63 @ 110 HHED63 @ 125
with fixed-setting overload release and adjustable short-circuit release
Switching capacity35 kA
High switching capacity65 kA
Extra-high switching capacity100 kA
FD250 A
70 80 90100
600–900 600–900 600–900 700–1200
FXD63 @ 070 FXD63 @ 080 FXD63 @ 090 FXD63 @ 100
HFXD63 @ 070 HFXD63 @ 080 HFXD63 @ 090 HFXD63 @ 100
HHFXD63 @ 070 HHFXD63 @ 080 HHFXD63 @ 090 HHFXD63 @ 100
L = 241W = 114D = 102(4.5)
110125150
700–1200 800–1500 800–1500
FXD63 @ 110 FXD63 @ 125 FXD63 @ 150
HFXD63 @ 110 HFXD63 @ 125 HFXD63 @ 150
HHFXD63 @ 110 HHFXD63 @ 125 HHFXD63 @ 150
175200225
900–2000 900–20001100–2500
FXD63 @ 175 FXD63 @ 200 FXD63 @ 225
HFXD63 @ 175 HFXD63 @ 200 HFXD63 @ 225
HHFXD63 @ 175 HHFXD63 @ 200 HHFXD63 @ 225
250 1100–2500 FXD63 @ 250 HFXD63 @ 250 HHFXD63 @ 250
JD400 A
200225250
1250–25001250–25001250–2500
JXD63 @ 200 JXD63 @ 225 JXD63 @ 250
HJXD63 @ 200 HJXD63 @ 225 HJXD63 @ 250
HHJXD63 @ 200 HHJXD63 @ 225 HHJXD63 @ 250
L = 279W = 191D = 102(8.9)
300350400
1250–25002000–40002000–4000
JXD63 @ 300 JXD63 @ 350 JXD63 @ 400
HJXD63 @ 300 HJXD63 @ 350 HJXD63 @ 400
HHJXD63 @ 300 HHJXD63 @ 350 HHJXD63 @ 400
LD600 A
450500600
2000–40003000–60003000–6000
LXD63 @ 450 LXD63 @ 500 LXD63 @ 600
HLXD63 @ 450 HLXD63 @ 500 HLXD63 @ 600
HHLXD63 @ 450 HHLXD63 @ 500 HHLXD63 @ 600
L = 279W = 191D = 102(8.9)
Release calibrationz z z
40 °C50 °C
BM
BM
BM
Note:Higher switching capacities available on request.
LD VersionFD VersionED Version JD Version
/>>
S. 5/4 C S. 5/4 Y
UL/NEMA Sentron Series Circuit-Breakers3-pole, up to 2000 A
5/4 Siemens NS PS ⋅ 2001
Selection and ordering data
Versiontype
OverloadreleaseIn = Ir
Short-circuitreleaseI i
Dimensions mm
A A
Switching capacity50 kA at AC 480 V
Order No. Price
High switching capacity65 kA at AC 480 V
Order No. Price
Extra-high switching capacity100 kA at AC 480 V
Order No. Price
WeightApprox.
(kg)
with fixed-setting overload release and adjustable short-circuit release
LMD800 A
500 600 700 800
3000–60003000–60003200–80003200–8000
LMXD63 @ 500 LMXD63 @ 600 LMXD63 @ 700 LMXD63 @ 800
HLMXD63 @ 500 HLMXD63 @ 600 HLMXD63 @ 700 HLMXD63 @ 800
Not available L = 406W = 191D = 114(20)
ND1200 A
90010001200
5000–100005000–100005000–10000
NXD63 @ 900 NXD63 @ 100 NXD63 @ 120
HNXD63 @ 900 HNXD63 @ 100 HNXD63 @ 120
CND63 @ 900 CND63 @ 100 CND63 @ 120
L = 406W = 229D = 152(58.1)
PD1600 A
120014001600
5000–100005000–100005000–10000
PXD63 @ 120 PXD63 @ 140 PXD63 @ 160
HPXD63 @ 120 HPXD63 @ 140 HPXD63 @ 160
CPD63 @ 120 CPD63 @ 140 CPD63 @ 160
L = 406W = 229D = 152(58.1)
RD2000 A
160018002000
5000–100005000–100005000–10000
RXD63 @ 160 RXD63 @ 180 RXD63 @ 200
HRXD63 @ 160 HRXD63 @ 180 HRXD63 @ 200
Not available L = 406W = 229D = 152(78.3)
Release calibrationz z z
40 °C50 °C
BM
BM
BM
RD VersionND VersionLMD Version PD Version
/>>
S. 5/5 C S. 5/5 Y
UL/NEMA Sentron Series Circuit-Breakers3-pole, up to 2000 A
5
Siemens NS PS ⋅ 2001 5/5
Accessories
For versions
ED
Order No.
FD
Order No.
JD, LD, LMD
Order No.
ND, PD, RD
Order No.
Opening coil Mounting: for ED version, external on the left side.For all other versions: internal mounting on the right or left side.
S17ED60 S18ED60 S01ED60 S02ED60
S03ED60 S15ED60 S04ED60 S06ED60
S16ED60S07ED60 S09ED60 S11ED60 S13ED60
S17FD60 S18FD60 S01FD60 S02FD60
S03FD60 S15FD60 S04FD60 S06FD60
S16FD60S07FD60 S09FD60 S11FD60 S13FD60
S17JLD6 S18JLD6 S01JLD6 S02JLD6
S03JLD6 S15JLD6 S04JLD6 S06JLD6
S16JLD6S07JLD6 S09JLD6 S11JLD6 S13JLD6
Not available Not availableS01MN6 S02MN6
S03MN6 S15MN6 S04MN6 S06MN6
S16MN6 S07MN6 S09MN6 S11MN6 S13MN6
Combination of opening coil and auxiliary contact Mounting: for ED version, external on the left side.For all other versions: internal mounting on the right or left side.
Not available Not availableS01ED62A S02ED62A
S03ED62A S15ED62A S04ED62A Not available
Not availableS07ED62A S09ED62A S11ED62A S13ED62A
Not available Not available Not availableS01JLD62A S02JLD62A
S03JLD62A S15JLD62A S04JLD62A Not available
S16JLD62AS07JLD62A S09JLD62A S11JLD62A S13JLD62A
Not available Not availableS01MN64A S02MN64A
S03MN64A S15MN64A S04MN64A Not available
S16MN64A S07MN64A S09MN64A S11MN64A S13MN64A
Combination of opening coil, auxiliary contact and alarm co ntact Mounting: for ED version, external on the left side.For all other versions: internal mounting on the right or left side.
S01ED62AAS02ED62AAS03ED62AA
S07ED62AAS09ED62AAS11ED62AAS13ED62AA
Not available Not available Not available
1 accessory module can be mounted on the right pole, on the leftpole or on both – 1 Order No. is equivalent to 1 module.
AC V DC V
24 48120208
240277480600
–––––
––––
––––
12 24 48125250
AC V DC V
24 48120208
240277480600
–––––
––––
––––
12 24 48125250
AC V DC V
120208240
––––
–––
24 48125250
Accessories for ED version
Accessories for FD version
Accessories forJD, LD, LMD versions
Accessories for ND, PD, RD versions
S. 5/6 C S. 5/6 Y
UL/NEMA Sentron Series Circuit-Breakers3-pole, up to 2000 A
5/6 Siemens NS PS ⋅ 2001
Accessories
For versions
ED
Order No.
FD
Order No.
JD, LD, LMD
Order No.
ND, PD, RD
Order No.
Minimum voltage coil Mounting: for ED version, external on the left side.For all other versions: internal mounting on the right or left side.
U01ED60 U02ED60U03ED60
U16ED60 U06ED60 U08ED60
U13ED60U14ED60 U10ED60 U12ED60
U01FD60 U02FD60U03FD60
U16FD60 U06FD60 U08FD60
U13FD60U14FD60 U10FD60 U12FD60
U01JLD6 U02JLD6U03JLD6
U16JLD6 U06JLD6 U08JLD6
U13JLD6U14JLD6 U10JLD6 U12JLD6
U01MN6 U02MN6U03MN6
U16MN6 U06MN6 U08MN6
U13MN6U14MN6 U10MN6 U12MN6
Combination of minimum voltage coil and auxiliary contact Mounting: for ED version, external on the left side.For all other versions: internal mounting on the right or left side.
U01ED62A U02ED62AU03ED62A
U16ED62A U06ED62A Not available
U13ED62AU14ED62A U10ED62A U12ED62A
W01FD64 W02FD64W03FD64
W16FD64 W06FD64 W08FD64
W13FD64W14FD64 W10FD64 W12FD64
U01JLD62A U02JLD62AU03JLD62A
U16JLD62A U06JLD62A Not available
U13JLD62AU14JLD62A U10JLD62A U12JLD62A
U01MN64A U02MN64AU03MN64A
U15MN64A U04MN64A Not available
U07MN64AU09MN64A U11MN64A U13MN64A
Auxiliary contact Mounting: for ED version, external on the left side.For all other versions: internal mounting on the right or left side.
A01ED62A01ED64A01ED62
A01FD62A01FD64A01FD62
Not available A01JLD64A01JLD64
Not availableA01MN64A01MN64
Alarm co ntact Mounting: for ED version, external on the left side.For all other versions: internal mounting on the right or left side.
B00ED62B00ED64B00ED62
Not available B00FD64B00FD64
Not available B01JLD64B01JLD64
Not availableB00MN64B00MN64
Combination of minimum voltage, auxiliary contact and alarm co ntact Mounting: for ED version, external on the left side.For all other versions: internal mounting on the right or left side.
U01ED62AAU02ED62AAU03ED62AA
U13ED62AAU14ED62AAU10ED62AAU12ED62AA
Not available Not available Not available
1 accessory module can be mounted on the right pole, on the leftpole or on both – 1 Order No. is equivalent to 1 module.
AC V DC V
120208240
277480600
––––
––––––
24 48125250
AC V DC V
120208240
277480600
––––
–––
–––
24 48125250
AC V DC V
240480–
––250
AC V DC V
120208240
––––
–––
24 48125250
Accessories for ED version
Accessories for FD version
Accessories for JD, LD, LMD versions
Accessories for ND, PD, RD versions
S. 5/7 C S. 5/7 Y
UL/NEMA Sentron Series Circuit-Breakers3-pole, up to 2000 A
5
AC V DC V
240480–
––250
Siemens NS PS ⋅ 2001 5/7
UL/NEMA Sentron series circuit-breakers
All breakers have been tested and qualifiedto the requirements set out in UL/NEMAspecifications:
Ampere rating range: 15 A – 2000 ASymmetric Ampere Rating UL RMS (kA):10/65
UL Sentron series moulded-case circuit-breakers protect system components andloads from thermal overload and short-circuits.
These circuit-breakers are enhanced by anextended accessory line, for solving any installation requirement. For instance: ope-ning coil, minimum voltage coil, auxiliarycontacts, alarm contacts, mechanical con-nec-ting studs, handles to control from out-side a door, device for locking connection,etc., all these accessories are easy to in-stall, even by the user.
These circuit-breakers are available in thefollowing models:
Model ED up to 125 AModel FD up to 250 AModel JD up to 400 AModel LD up to 600 AModel LMD up to 800 AModel ND up to 1200 AModel PD up to 1600 AModel RD up to 2000 A
The breaking capacity is identified by a color code as follows:
Blue: standard breaking capacityBlack: high and extra-high breaking capacity
UL/NEMA Sentron series circuit-breakersuse the principle of “blow-apart” contact.Starting from the basic laws of physics, thisprinciple is based on the electromagnetic repulsion force between adjacent con-ductors which carry currents in opposite di-rections. In these circuit-breakers, contactsthat carry current are arranged so as to ge-nerate opposite magnetic fields. The con-tact arms, one fixed and one movable, arepositioned close to each other. As the faultcurrent rises, magnetic repulsion forces thecontacts to part. This forced separation immediately generates an arc. This arc actsas a major source of current impedance, restricting fault energy to lower levels forfast extinguishing in the arc chute.
•• QualitySentron series circuit-breakers are manu-factured to the highest quality standards within a ISO 9002 certified facility.
•• Moulded CaseCircuit-breaker housing is made of high impact, high dielectric strength polymer material.
•• Positive operation “ON” and “OFF” states are indicated by theposition of the operating handle. An inter-mediate position indicates that the circuit-breaker is in a tripped position.
•• Flexibility of application
Sentron series circuit-breakers may beused for individual enclosures, switchbo-ards, lighting and power panels as well asin motor control centers.
•• Minimum downtime Downtime is reduced and fuse replacementis eliminated in Sentron series circuit-breakers. In case of overload or short-circuit,the breaker trips, stopping current flow and protecting the conductors. After the normalconditions are restored, the breaker can beclosed (“ON”) again.
•• Space saving By virtue of their compact design, the Sentron series are space-saving, which is a major factor to equipment users. By offering high interruption ratings in smallcompact versions, the savings to userscan be substantial.
•• Trip-free mechanism By design, the Sentron series circuit-brea-kers use a trip-free mechanism, which is anintegral part of the quick-make, quick-breakmechanism that is independent of the hand-le toggle. It opens the circuit-breaker contacts under overload and short-circuitconditions, even if the breaker handle isheld in the “ON” position.
•• Three-pole disconnectionThese circuit-breakers solve the problem ofa failure on one phase. When a short-circuit or an overload occurs on a singleconductor, the three-polar disconnectionmechanism opens all contacts of the circuit-breakers at the same time. The same occurs when the circuit-breaker is driven byan accessory.
•• Thermal trip
This provides protection against sustainedoverloads. The thermal trip is common toall models.
•• Electromagnetic tripThis provides protection against short-circuits. For model ED the electromagnetictrip is fixed.For models FD to RD the electromagnetictrip is adjustable.
•• Test pushbuttonAll Sentron series circuit-breakers feature apushbutton which can be pressed to checkthe opening/closing operation of the circuit-breaker mechanism.
•• Contacts
All contacts are alloy materials designed to give above-normal endurance during service use.
•• Arc chutes Arc chutes are designed to confine, divideand extinguish an arc each time the breakercontacts interrupt a short-circuit. The arcchute, therefore, must dissipate the arcsthat are caused when the circuit-breaker interrupts current flow. It contains a stackof U-shaped steel plates held together byinsulating material. The steel plates dividethe arc and cool the gases generated bythe arc.
•• Further versionsFurther circuit-breaker versions are available as follows:With exchangeable release:enables change to a different rating. With electronic release:enables very fine adjustments for specificapplications.With magnetic release:to be used only for motor start up. Without magnetic or thermal release:to be used as switch disconnector.
UL/NEMA circuit-breakers for AC, CQD and QJ versions
The CQD and QJ versions of the circuit-breakers are compact and ideally suitablefor industry and work-sites.They feature a high breaking capacity, i.e. 10/22 kA at 240 V (QJ version) and 65 kA at 240 V and 14 kA at 480 V (CQD version).The CQD version is fixed by means ofscrews and/or rail according to DIN.The QJ version is screwed.QJ version circuit-breakers: 2-pole and 3-pole.CQD version circuit-breakers: 1-pole, 2-pole and 3-pole. Set of accessories available.
Current-limiting circuit-breakers for AC, compact design
S. 5/8 C S. 5/8 Y
UL/NEMA Sentron Series Circuit-Breakers3-pole, up to 2000 A
5/8 Siemens NS PS ⋅ 2001
Technical data
CQD/QJ Sentron series
Version CQD QJ E F J, L M, N P, R
Number of poles 1, 2, 3 2, 3 3 3 3 3 3
Rated current In A 100 225 125 250 400, 600 600, 1200 1600, 2000
Rated impulse withstand voltage UimpMain leads kV – – 8 8 8 8 –
Ambient temperature in operation °C –20 up to +70
Permissible loadfor different temperatures around the circuit-breaker, as a function of the circuit-breaker rated current– Circuit-breakers for– line protection
% for 40 °C % for 50 °C % for 55 °C % for 60 °C % for 70 °C
100 92 87 83 72
100 92 87 83–
100 92 87 83 72
100 94 90 87 80
100 92 87 84 75
100 94 87 84 76
100 94 87 84 76
Short-circuit breaking capacityUL 489/NEMA
AC for 240 VAC for 480 VAC for 600 V
65 – –141) – –– – –
10 22 –– – –– – –
65 100 10018 42 65– – 25
65 100 2036 65 1022 25 2
65 100 20035 65 10025 35 50
65 100 20060 65 10026 50 50
65 100 20050 65 10025 50 65
Endurance (UL/NEMA) Operating cyclesMaximum operation frequency. 1/h
10000 360
8000 300
10000 360
6000 240
6000 240
3500 50
2500 60
Cross-section and type of terminals for mainconductorsType of terminalsSolid or stranded conductors mm2
Boxterminals2.5–50.0
Boxterminals16.0–150
Boxterminals2.5–50.0
Boxterminals35.0–150
Boxterminals45.0–240.0
Boxterminals50.0–240.0
Boxterminals50.0–240.0
Circuit-breaker loss power forrated current Inwith symmetric load on the three phases– for line protection W 15.6 27 12.1 26.4 55/86.5 119/225 228/415
Permissible mounting position
1) Rated breaking capacity for 277/480 V AC.
NSK-7808
90° 90°
S. 5/9 C S. 5/9 Y
NSK-7809
90° 90°
Circuit-Breakers1- to 3-pole, up to 2000 A
5
Siemens NS PS ⋅ 2001 5/9
NSK-7559a
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
Current
Bre
ak-
time
A
Fig. 5/1 3VF2, CQD versions
IEC, UL/NEMA Circuit-Breakers1-, 2- and 3-pole, up to 2000 A
S. 5/10 C S. 5/10 Y
Characteristic curves (IEC, UL/NEMA Circuit-Breakers)
Characteristic curves (UL/NEMA Circuit-Breakers)
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
NSK-7561a
600V
480V240V
Current
Bre
ak-
time
A
Fig. 5/3 ED versionED4, HED4, HHED6 types
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
NSK-7563a
600V480V
240V
Current
Bre
ak-
time
A
Fig. 5/5 JD versionJXD6, HJXD6, HHJXD6 types
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
NSK-7564a
600V
480V
240V
Current
Bre
ak-
time
A
Fig. 5/6 LD versionLXD6, HLXD6, HHLXD6 types
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
NSK-7562a
600V
480V240V
Current
Bre
ak-
time
A
Fig. 5/4 FD versionFXD6, HFXD6, HHFXD6 types
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x In
NSK-7560a
Current
Bre
ak-
time
A
Fig. 5/2 QJ versionQJ2, QJH2 types
5/10 Siemens NS PS ⋅ 2001
Characteristic curves
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
NSK-7565a
Bre
ak-
time
Current
A
600V
480V
240V
Fig. 5/7 ND versionNXD6, HNXD6, CND6 types
600V
480V
240V
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
NSK-7566a
Current
Bre
ak-
time
A
Fig. 5/9 PD versionPXD6, HPXD6, CPD6 types
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
NSK-7567a
600V
480V
240V
Current
Bre
ak-
time
A
Fig. 5/10 RD versionRXD6, HRXD6 types
10-3
10-2
10-1
100
101
103
104
102
s
1 10 100 1000 6000x I n
NSK-7574a
Current
Bre
ak-
time
A
Fig. 5/8 LMD versionLMXD6, HLMXD6 types
S. 5/11 C S. 5/11 Y
UL/NEMA Circuit-Breakers3-pole, up to 2000 A
5
Siemens NS PS ⋅ 2001 5/11
S. 5/12 C S. 5/12 Y
5/12 Siemens NS PS ⋅ 2001
Circuit-Breakers
ED circuit-breakers
¿ 4.23 ∅ mounting hole9.63 ∅ × 3.30 counterbore depth
À Test button5.33 Sq.
On
101.5675.38
38.10
5.59 Ref.
3.30 Ref.10.412.295.59
45°
Tripped
Reset
12°50'±1°
6°50'±1°Off
9.14 Thick3° Taper
26.92
60.45
101.6011°10'-1°
21°45'-1°±0°
0.56
4.83
72.64 60°
9.53
0.78
1.59
10.16
127.39
48.39
10.19
6.32
R52.58
25.40
3.30
20.6112.76
2.29
2.29
9.65
14.28
5.68
19.05
12.71
16.51
34.80
55.88
73.15
25.40
50.80
76.20
Breaker
Typ.
6.35
20.83
127.00160.78
20.62
±0°
$
%
Front View
Side View
Top View
S. 5/13 C S. 5/13 Y
Siemens NS PS ⋅ 2001 5/13
Circuit-Breakers
5
FD circuit-breakers
¿ Test push-button7.87 sq.
À 6.86 ∅ mounting holes12.70 ∅ × 9.65 counterbore depth,4 holes
Á 3.18 ∅ × 8.64 depth3 blind holes
 Magnetic release adjustmentà Release moduleÄ Auxiliary cable outlet
(both sides)
A
A
BC
C
B
65.09
31.50
20.3236.07
99.61
17.53
47.96
42.98
20.32
4.83
12.7
17.53
29.41
8.64
2.29
101.61
82.55 R
7.87
115.02
101.59
76.34
17.27
15°
5° 30°Typ
17°50'
5°45'
21°30'
ResetOff
On
Tripped
12.7 Thick3° Taper
Handle
41.00
76.51
38.10
26.93
38.1011.43
25.40
32.26
29.74
37.85 38.10
113.80
241.31
190.51
7.37
38.1038.1018.80
20.07 Ref
52.38
33.22
.76 .76
5° Typ
130.56
23.11
26.67
5.085.08
8.13
18.8030.73
27.43
19.05
2.794.32
Front View Side View
Detail A Detail C
Top View Detail B
$
%
&
(
)
*
JD and LD circuit-breakers
5/14 Siemens NS PS ⋅ 2001
9.65
77.75
29.32
81.54
7.91
87.38 R
16.51
39.67Typ
12°15'Off18°50'
21°30'
101.60
17.15
2.29
29.32
19.81
50.43
30° Typ
16.51
11.94101.66
14°50'Tripped
19.84Typ
30°Typ
6.50Typ
Handle
Reset
On
12.7 Thick3.5° Taper
189.99
247.65279.37
66.07
36.07 63.50
21.59
46.47
76.50
63.50
16.0 Typ
7.87Sq.
63.23Typ
63.50Typ
32.96
38.61 38.105/16-18 Unc-2B
3/8-16 Unc-2B
22.35
45.21
31.77
12.506.60 Typ
19.56Ref
63.5063.50
28.58
73.0346.02
1.52 1.52
24.38Ref
137.87 Ref
5° Taper Typ
125.55
A
A
B
B
Front View Side View
Detail A
Top View
Detail B
$
%
&
(
$
)
S. 5/14 C S. 5/14 Y
Circuit-Breakers
¿ Removableconnector cover
À Test push-button
Á 7.14 ∅ mounting holes13.49 ∅ × 39.37 depth counterbore4 holes
 Magnetic releaseadjustment
à 12.7 × 7.87cableway
Siemens NS PS ⋅ 2001 5/15
LMD circuit-breakers
ON
188.98
101.60
87.38
7.87
145.03
17.27
33.32
36.58 41.15
36.58 41.15
63.25
17.27
11.94
2.29
33.32
114.30
16°50Reset
14°50Tripped
12°15Off
21°30
.50 Thick3.5° Taper
36.07 63.50 63.50
21.59
109.98
76.45
63.5063.25
406.40
129.54
79.50Typ
7.87 Sq.
247.65
187.96
24.38
63.50 63.50
45.97
73.15
1.52 1.52
5° Taper (Typ)
151.38
On
$
%
&
(
)
&
Front View Side View
Top View
S. 5/15 C S. 5/15 Y
5
Circuit-Breakers
¿ Removable coverÀ Test push-buttonÁ Removable terminal cover
 0.281 ∅ mounting holes0.531 ∅ × 1.55 counterbore depth4 holes
à Magnetic release adjustment
ND circuit-breakers
S. 11/16 C S. 11/16 Y
5/16 Siemens NS PS ⋅ 2001
Circuit-Breakers
¿ Removable terminal coverÀ 11.18 ∅ mounting holes
17.53 ∅ × 22.23 counterbore depth4 holes
Á Test push-button
 Magnetic releaseadjustment
à Connector coverÄ CablewayÅ Release unit
37.34
152.48
36.61
17.53
19.05
4.83
251.46 R
138.68
181.87
119.53
101.60
36.47
17.5213.72
52.02
116.71143.33
37.34Typ.
73.66 Typ.Max.
128.02 R
1.1081.79 553.72
8.64
16°30
17.02
18°
18°
16.0Thick
3° Taper
Tripped8°
Reset17.1 x 7.62
87.38
89.41
TypTyp63.512.7
38.1
22.35Typ
406.35 361.95
228.57
76.17 76.20
76.2 76.2
111.76
113.08
7.87 Sq.
76.0776.07
1.52 1.52
5° Taper Typ
91.45
54.22
209.55 Ref
38.02Ref 38.43
49.2853.34
54.89
3/8-16 Unc
32.55
15.49
14.73 Typ
14.72 Typ
A
A
B
B
O
OFF
Side viewFront view
Detail A Detail B
Top view
&
(
$
)
*
+
%
$
S. 11/17 C S. 11/17 Y
PD and RD circuit-breakers
138.68
251.46 R.
128.
02 R
.
181.86
119.63
8.64
17.02
19.05
17.53
16.0
11.18
13.72Typ.
37.34 Typ.
4.83
152.40
21.79
143.26
209.03
209.55
155.70
12.7038.10Ref.
116.71
11.05
18°
8°Tripped 18°On
Reset
16°30' Off
16.0 Thick3° Taper
17.02 x 7.62647.70
615.70
237.74
187.98
346.20
228.60
114.30 89.41
76.20 76.20
87.38111.76
113.03361.95
580.14
269.75
146.05
292.10
106.43
38.10
76.20
38.10
81.28
406.40
38.10
19.05
104.65
14.22 Dia.(Pls.)
27.22 — 32.66in. lbs.
7.87square
91.44
54.10
1.52 1.52
17.27
11.18
25.40
5°TaperTyp.
Side viewFront view
Top view Section A
$
%
&
(
)
) * +
,
Siemens NS PS ⋅ 2001 5/17
¿ 11.18 ∅ mounting holes17.53 ∅ counterboresee : Section A
À Tightening torque aÁ Magnetic release adjustment Special note: The connector TC5R600
is to be mounted on the sets of lower holes.It is necessary only with RD and HRD frames
à Removable terminal coverÄ Cable connectorÅ Mounting padÆ Cableway
Circuit-Breakers
5
CQD circuit-breakers
¿ For DIN standard mounting railÀ Mounting position “A”
for accessoriesÁ Connectors
5/18 Siemens NS PS ⋅ 2001
S. 11/18 C S. 11/18 Y
Circuit-Breakers
2x 15.75
22.10
35.81
85.09
21.34
16.76
11.439.40
R 38.61Reset
Off
2x R 1.5217 15
24 38.35
Tripped
On2 x 3Taper
6.60
4.8322.8666.80
73.15
Str
ipS
trip
2x .76
25
25.40
2x .76
40
50.80
2x .76
25.40
100
76.20
49.28 74.6811.94 37.34
415
4x R 2.29
56.3988.90
6x R 4.06
25.4025.40
$
%
&15 A - 40 A
&45 A - 100 A
QJ circuit-breakers
Circuit-Breakers
5
Siemens NS PS ⋅ 2001 5/19
¿ 3-poleÀ 2-poleÁ Fixing screws, 10-32 × 2.5
0.314 × 0.141R mounting hole∅ 532 counterbore
 Thread UNC 2B 9.65 × 16
à 55.58 (4 pcs.)Holes for fixing screws
92.08
64.26
34.93
13.11
3.1
25.40
20.32
15.7
15.7526.5
28.5
71.88
26.515.75
15.75
20.32
Tri
25
10
.79
Tri
114.30
76.20
38.10 38.10
15.05
40.13
4.78 x45
76.20
102.36
.66
36.82
20.96
17.48
34.93
19.84
146.05
177.80Max.
38.10
$
% &
(
)
S. 11/19 C S. 11/19 Y S. 11/19 M